Dairy Environmental Systems Program Anaerobic Digester at Lamb Farms: Case Study

Similar documents
Manure Management Program

Manure Management Program

Manure Management Program

Manure Management Program

Manure Management Program

Manure Management Program

Dairy Manure Management: Treatment, Handling, and Community Relations. AD Performance Goals:

Manure Management at Table Rock Farm, Inc. Case Study

Small Scale Digester Case Study: Peters/USEMCO Anaerobic Digester

Basic digester types include plug-flow, horizontal and vertical mixed, fixed-film, and covered lagoon; each is discussed in brief detail below.

Reinfold Farm Agricultural Engineering Building, University Park, PA (814)

Digester Systems in the NE: Successful Case Studies

Regenis Construction Management and Operations Services Edaleen Dairy, Lynden, WA

Digester Systems in the NE: Successful Case Studies

Small Farm Manure-Based Anaerobic Digestion Systems and Barriers to Increasing their Implementation in New York State

Preliminary Comparison of Five Anaerobic Digestion Systems on Dairy Farms in New York State

Anaerobic Digestion Treatment Case Study: An Odor Control System for Dairy Farms

Livestock and Poultry Environmental Learning Center Monthly Webcast Series Nutrient Capture from Manure

THE CHARACTERIZATION OF SULFUR FLOWS IN FARM DIGESTERS at EIGHT FARMS

Anaerobic Digestion and Nutrient Recovery

Observed Temperature Change Northeast U.S.

Manure-based Anaerobic Digestion In New York State: Where we were, Where we are, and Where we can be

Economic Feasibility of Anaerobic Digestion To Produce Electricity on Florida Dairy Farms 1

Small-Scale Anaerobic Digestion and Manure Management

Small Digester Feasibility in the Upper Midwest

Profitability of Digesters

ORGANICS RECOVERY ALTERNATIVES

Nutrient Recovery after Anaerobic Digestion

Anaerobic Digestion at Morrisville State College: Internal Combustion Engine Teardown and Evaluation

MEASUREMENT AND VERIFICATION (M&V) PLAN

Brent Gloy, April


DRINKING WATER REQUIREMENTS FOR LACTATING DAIRY COWS. M. J. Brouk, J. F. Smith, J. P. Harner 1, and S. R. DeFrain

Practical Considerations and Implementation of Anaerobic Digester Systems

Lagoon And Wetland Treatment Of Dairy Manure

How Carbon Credits are Generated from Livestock Projects

CA Dairy Anaerobic Digester Case study: Fiscalini Farms

Key Elements of Biogas Energy Systems Anaerobic Digesters

Anaerobic Digestion Basics

Microturbine Operation with Biogas from a Covered Dairy Manure Lagoon

4/19/2013 PROFIT FROM POOP? Bob Nagel, MS DVM Holsum Dairies LLC

ANAEROBIC DIGESTION OF FLUSHED DAIRY MANURE

What s New in Manure Equipment and Management

Pine Island Farm Digester Facility Sheffield, MA 01257

Utilizing Anaerobic Digester Capacity to Process Source Separated Organics: Two Case Studies

Figure 1. Basic principle of ventilation: fresh air mixes with shelter air contaminants and is discharged. CONTAMINATED AIR OUT MOISTURE MIXING GASES

Integrated Manure Management System

The AgSTAR Program. Managing Manure with Biogas Recovery Systems. Improved Performance at Competitive Costs 1EPA

North Country New York Dairy Farmer Views on Alternative Energy Production

Digester Case Study: New Horizons Dairy, LLC. by: Terry Feldmann, P.E. Agricultural Engineer Maurer Stutz, Inc. Peoria, IL

Dairy Environmental Systems Program

Anaerobic Digestion at Morrisville State College: A Case Study

Large Scale Vermicomposting of Agricultural Byproducts

A Small Scale Anaerobic Digester Operating in Ontario - Klaesi Brothers Farm

Economic Analysis of Mechanical Sand-Manure Separation of Flushed Sand-Laden Dairy Manure

Generating Carbon Credits from Livestock Projects Perspectives of a Project Developer

Anaerobic: without oxygen Anaerobic organisms or anaerobes: organisms that do not require oxygen for growth

Why consider AD? Definitions: What can be digested? 8/8/2016

Who Should Be Raising Your Heifers?

Bioenergy Projects for Agribusiness Bioenergy Australia Biogas Workshop - Gold Coast

Keys Keys to to Successful Successful Operation Farm Based Digesters g

QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PLAN

Innovation Center for U.S. Dairy; Dairy Power Project. Briefing Paper. The Dairy Power Project Summit October 29 and 30, 2009

Biogas Solutions for America s Dairy Industry

A Dozen Successful Swine Waste Digesters

Overview of Biogas Technology

Anaerobic Digester at Craven Farms. A Case Study

Anaerobic Digestion at Morrisville State College: A Case Study

SAND SOLUTIONS. A Better Environment Clean Sand, Comfortable Cows & Maximum Sand Recovery AGRICULTURAL SYSTEMS

Vermont Tech Community Anaerobic Digester! Harvesting renewable energy & recycling nutrients for a more sustainable community

Energy-demand analysis for a dairy-farm with a biogas plant operating in either self-sufficient or spot-market mode

Contaminant Removal Considerations for Anaerobic Digestion. National Composting Conference Halifax 2014

Reimagining Reusable Resources TM.

Manure Management Milk Shake Dairy Ken Johnson Cache County, Utah

Agenda and Goals for Today

Milking Center Wastewater: Planning, Design, Construction, Documentation

Minnesota s Potential for Electricity Production Using Manure Biogas Resources

Summary of Manure Handling Systems in the Context of Hullcar

Manure Management Panel Adapting our Dairies. Ripp s Dairy Valley

The Uilenkraal Bio-gas Power Generation Plant

Manure biogas developer ready for round two as green power trend

Where excellence and opportunity meet.

CH4 Biogas: Napoleon Biogas Case Study April 4, 2017 Odor Management Workshop

DUBLIN LAKES PIVOT RANCH

SW CERT Biogas Digester Meeting. May 12, 2011

Economic Feasibility of Anaerobic Digestion To Produce Electricity on Florida Dairy_F_a_r_m_s_1 _

Small Digester Case Study Keewaydin Farm, Stowe, Vermont

CH Four Biogas.

Economics of Tunnel Ventilation for Freestall Barns

Handling Sand-laden Manure

Ultrafiltration Testing Report

Using Compact Combined Constructed Wetland as Post Treatment for Biogas Wastewater

Advancing Energy Independence with Environmental Benefit: Livestock Manure Digesters. Chris Voell, National Program Manager AgSTAR Washington, DC

Waste to Energy Untapped Opportunity?

EXECUTIVE SUMMARY PROCESS AND SITE SELECTION

AEM Tier 2 Worksheet Greenhouse Gas Mitigation Opportunities. Glossary

Draft. Feasibility Study of Anaerobic Digestion Options for Perry, NY

FACTORS AFFECTING DRY MATTER INTAKE BY LACTATING DAIRY COWS. M. J. Brouk and J. F. Smith

Quality, Care, Comfort

Manure Application Cost Study New York State Spring 2012

Transcription:

1 Dairy Environmental Systems Program www.manuremanagement.cornell.edu Anaerobic Digester at Lamb Farms: Case Study Michael Boerman, Jenny Pronto, Curt Gooch, P.E. Dept. of Biological and Environmental Engineering, Cornell University Contents: AD overview Farm overview o Why the digester? Digester System o System diagram o System and process description o Liquids and solids process description o Heat and electricity generation Economics o Initial capital costs Benefits & Considerations Lessons learned Contact information Anaerobic digestion overview Digester type Plug Flow Digester designer DVO (Formerly GHD) Date Commissioned 2010 Influent Raw manure, whey permeate Stall bedding material Post-digested separated manure solids Number of cows 2,300 lactating cows Rumensin usage Yes Dimensions (width, length, height) 72-ft X 150-ft X 16-ft Cover material Pre-cast concrete Design temperature 96-100 degrees F Estimated total loading rate 40,000 gallons per day Estimated hydraulic retention time 24 days Solid-liquid separator Two EYS; screw press solid separators Biogas utilization 476-kW Guascor Engine Generator Carbon credits sold/accumulated No Monitoring results to date N/A

2 Farm overview Lamb Farms milks about 2,300 Holstein dairy cows (Figure 1) The farm is located outside the town of Oakfield, NY The onsite digester was commissioned in the beginning of 2010 Lambs milk on a Westfalia Surge 60-cow rotary parlor 3 times a day Why the digester: Lamb Farms chose to build a digester as a way to mitigate the rising cost of both electricity and bedding. The anaerobic process has the potential to greatly reduce the odor emitted from manure storages, which in the case of Lamb farms, is located near a local school. Being so close to a town center, Lambs must be proactive in dealing with odor issues. Digester System: Figure 1. Freestall barn at Lamb Farms Figure 2. Lamb Farms digester flow diagram System and Process Description The process flow diagram for the Lamb Farm digester is shown in Figure 2. Of the 2,300 dairy animals milked on-site at Lamb Farms, only about 1,050 of them provide manure that is utilized by the digester. The farm decided to only send manure from one of the freestall barns so that they could continue to use sand bedding in the other barns. The

3 farm has two different manure systems; the anaerobic digester, which serves one barn, and a sand separation system, which serves the barns that, are bedded with sand. The sand-laden manure from the portion of the farm that houses cows bedded with sand, is sent to a Mc Lanahan sand-manure separator. The farm not only processes the manure from the dairy cows but also takes in other substrates including 8,000 gallons a day of whey Permeate. The substrates are unloaded into two 5,000-gallon fiberglass tanks. The manure and substrates are first pumped into a mixing pit, and then transferred into the digester. The digester is made from cast-in-place concrete with a pre-cast top, which is covered in spray foam insulation. A portion of the biogas taken from the headspace of the digester is then recirculated back into the digester acting as a form of mixing. After about 24 days in the digester the influent then gets pumped up to two solid-liquid separators. From the separators the liquid effluent gets pumped to a long-term earthen storage. A CHP unit that produces electricity and heat for the farm utilizes the biogas that is harvested from the process. Liquids and Solids Process The manure is collected from the barn by alley scrapers. The scrapers collect the manure into a central pit, where it is then pumped into the mixing pit. After effluent exits the digester it gets pumped to two solid liquid separators (Figure 3). The material is then separated as it drops down into a commodity shed where it is stored for later use. The solids that are produced are used to make bedding, which is only used in the barn that provides manure for the digester. Additionally, the separated solids bedding is applied three and a half times per a week. Currently more solids are produced than is needed for bedding purposes. Figure 3. Solid-liquid separator Heat and Electricity Generation The biogas is collected from the 24-inch headspace at the top of the digester. A portion of the biogas is then recirculated back through the influent by way of pipes near the heating racks on the center wall within the digester. This facilitates the mixing of the influent. The biogas is utilized by a Guascor SFGLD 360 CHP; a 12-cylinder engine that powers a 476-kW generator. Heat from the energy conversion process is then used to heat and maintain the temperature of the digester. Excess heat is also used to heat some barns, the

4 milking parlor, and milking center wash water. The CHP unit runs at about 350-kW consistently. The farm uses the majority of the electricity generated but does sell the excess power under the NYS Net Metering law to National Grid. The farm preforms oil changes on the engine every 600 to 700 hours of run time and the engine heads must be rebuilt every 14,000 hours. Economics: The entire project, from engineering costs to equipment and construction costs, was roughly $1.6 million. The farm received several grants including one from NYSERDA. All of the grants totaled about $1.4 million. The savings in bedding and electricity, as well as the tipping fees received, have proven to offset the initial capital costs at Lamb Farms. Benefits and Considerations: Benefits Odor control Potential revenue from: 1) Value-added products 2) Reduction of purchased energy 3) Sale of excess energy 4) Food waste tipping fees 5) Efficient use of biogas production 6) Carbon credit sales Nutrient conversion, allowing use by plants as a natural fertilizer, if effluent is spread at an appropriate time Pathogen reduction Considerations Possible high initial capital and/or high operating costs Long and tedious contracts with the local utility; may require special equipment for interconnection Dedicated management of the digestion system is required Careful attention to equipment maintenance and safety issues due to the characteristics of raw biogas Increased land base may be required to handle the imported food waste nutrients Specific permits may be required to import food waste Lessons Learned: H 2 S levels should not be ignored and a system to control the levels should be well thought out from the beginning of a digester process. Plug-flow style digesters are prone to build up of solids at the bottom and eventually need to be cleaned out, which can be costly and disruptive to typical farm duties. A company that provides full service anaerobic digester planning, including technical and business consulting, as well as other resources as related to anaerobic digesters, is in high demand for farms that have anaerobic digesters. Contact information: Mathew Lamb, owner and operator at Lamb Farms. Phone: (585) 704-4170, E-mail: Matthewalamb@yahoo.com Steve Kruppenbacher, Digester Operator, Phone: (585) 356-0784 Email: Krupp9@dishmail.net Curt Gooch, Dairy Housing and Waste Treatment Engineer, PRO-DAIRY Program, Cornell University. Phone: 607-255-2088, E-mail: cag26@cornell.edu

5 Acknowledgements The authors would like to thank the New York State Energy Research and Development Authority (NYSERDA) for funding in support of this work. Any opinions, findings, conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of NYSERDA or the State of New York, and reflect the best professional judgment of the authors based on information available as of the publication date. Reference to any specific product, service, process, or method does not constitute an implied or expressed recommendation or endorsement of it. Further, Cornell University, NYSERDA and the State of New York make no warranties or representations, expressed or implied, as to the fitness for particular purpose or merchantability of any product, apparatus, or service, or the usefulness, completeness, or accuracy of any processes, methods, or other information contained, described, disclosed, or referred to in this publication. Cornell University, NYSERDA and the State of New York make no representation that the use of any product, apparatus, process, method, or other information will not infringe privately owned rights and will assume no liability for any loss, injury, or damage resulting from, or occurring in connection with, the use of information contained, described, disclosed, or referred to in this publication.