NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

Similar documents
TITLE: SPECIFICATION NO. PE-MSE-VD-VP VOLUME:

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

Submersible Axial Flow Propeller Pumps

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

DIVISION 15- MECHANICAL Section Fire Pumps

Series Sump and Sewage Systems

SUGGESTED SPECIFICATIONS

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

CombiSump. Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610

SUGGESTED SPECIFICATIONS Pump Frames through 64132

VOGEL - Submersible Pumps in Stainless Steel Design TVS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

AUTOCLAVE AIR COMPRESSORS

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

10" Submersible Pump General Data

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

HPGR200 2 HP. Capacity-U.S. G.P.M.

Borehole Pumps Best Practises

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

C o l u m n S u m p P u m p s

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

SECTION PACKAGE BOOSTER PUMP STATIONS

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

WARRENDER, LTD. Services. Ammonia & CO² Circulation and Transfer Pumps

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

SD/SW/VS50 SD50 SW50 VS50

SPECIFICATION CUM COMPLIANCE CERTIFICATION FOR PRESSURE TESTING PUMP

Goulds API ISO / API 610 VS4 Vertical Sump Pump

B. Wiring Diagrams: For power, signal, and control wiring.

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

Talwandi Sabo Power Limited Tender document for Design & Engineering, Supply and Erection of Slurry pumping system from Plant to Ash Dyke

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Hannah Yan. Mobile/Skype/WhatsAPP: Wechat:yhr MSP HEAVY DUTY SUMP PUMPS

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

ANNEXURE C to Open tender ENQ. No. BAP/PUR/FGD/SLURRY PUMPS/ E dt

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

TM Series Induced Draft Cooling Tower Specifications

PREMIER Low Profile Induced Draft Cooling Tower Specifications

VSS S U B M E R S I B L E S E W A G E P U M P S

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Goulds Two Stage, Horizontally Split Case Pump

Goulds Multistage Process Pumps

Pump Division LNN. Between Bearing, Axially Split, Single Stage, Double Suction Pump. Bulletin PS-20-1f (E/A4)

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

TARRANT COUNTY PURCHASING DEPARTMENT

API 675 Evaluation. Section 1 General. 1.5 Referenced Publications. 1.1 Scope. 1.6 Unit Conversion. 1.2 Alternative Designs

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

MODEL 16ASX T/S - SPECIFICATION

B. Pumps are to be manufactured by Flygt Pumps. No substitutes will be considered.

All product images are indicative only General characteristics

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

SECTION HVAC PUMPS. A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation.

FLOWSERVE CORPORATION Guardian Pumps. Centrifugal ANSI Pumps Product Training Program

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

VOLUME -IIB TECHNICAL SPECIFICATION FOR MISCELLANEOUS PUMPS

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB

SUMMARY OF PRICES FOR FOR FIRE FIGHTING WORKS FOR Phase-1,(Block-G&H) Type-B

Bid Opening Date: January 25, 2018

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

SECTION SLUDGE HOLDING TANK DECANTER PUMP

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

Vertical Turbine Pumps

SMP. Single-channel closed impeller. submersible pumps PRODUCT CATALOGUE General characteristics

Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale , Kolhapur Dist. TENDER NO D5

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

MS/MSN Marine Single Suction Pump

TECHNICAL SPECIFICATION OF HORIZONTAL MILLING MACHINE

SEWAGE PUMPS CUTTER PUMPS NON-CLOG PUMPS DRAINAGE PUMPS GRINDER PUMPS SINGLE CHANNEL PUMPS VORTEX SEWAGE PUMPS VORTEX & AGITATOR PUMPS

VSX TECHNICAL BROCHURE

SUGGESTED SPECIFICATIONS

TECHNICAL BID T 3506

SECTION 2110 PRODUCT INFORMATION TYPE HBB SOLIDS-HANDLING WASTEWATER PUMPS COMPLETE HBB PUMP INCLUDES:

Material Description Quantity UOM. (a) The bidder to confirm that the submersible pump shall conform to IS 8034:2002 specifications.

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

CombiSump. Vertical long shaft sump pump, according to ISO 2858, EN 733, API 610 (VS4)

VIBRATION ANALYSIS OF VERTICAL PUMPS

Peerless Pump Company Handbook of Engineering Data

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

Self-Priming pumps, when it really matters

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

PARTICULAR SPECIFICATION M18: MECHANICAL CENTRIFUGAL PUMPS

BUREAU OF INDIAN STANDARDS (Western Region Office, Mumbai) DRAFT PRODUCT CERTIFICATION MANUAL FOR COMMENTS. Our Ref: DDGW Sectt(PCO/RD) 23 Jan 2014

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

Weir Specialty Pumps. WEMCO Torque-Flow

HWX. API OH3 Pump Bearing Frame. API OH4 Rigidly Coupled. API OH5 Close Coupled. API 610 Vertical In-Line Process Pumps.

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

Transcription:

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 DATA SHEET A ANNEXURE - A Sr. Item Description Sr. Item Description A. GENERAL DATA B. PUMP DUTY PARAMETERS 1. System Name 1. Rated capacity, m 3 /h Total Developed Head 2. Tag Nos. 2. at rated capacity (excluding pump internal losses), mwc 3. Project Name 3. Range of Operation 4. Type of Suction 4. Duty 5. Pump shut-off head (Maximum), mwc Maximum 5. Location 6. Synchronous speed at 50 Hz, rpm 6. No of Pumps H-Q characteristics Required 7. requirement (For two units) 7. Max. Ambient Temp. C 8. Dewatering Capability Seismic Permissible tolerance 8. Qualification 9. in rated capacity at requirement rated head 9. Whether Pumps Acceptable Tolerance Working in 10. in head Parallel 10. Sump Bottom LIQUID DATA Enclosed as Level Elevation, C. Annexure m HWL 1. Pumping Liquid Sump Water 11. Maximum Liquid Level, m 2. LWL Temp. 12. Applicable Specification 3. Sp. Gr. a. Pump 4. TDS, ppm b. Motor 5. ph 13. Sump 6. Dimensions Maximum Particle/ Debris Size, mm

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 2 OF 4 Sr. Item Description Sr. Item Description D. PUMPS CONSTRUCTION E. ACCESSORIES AND SERVICES FEATURES REQD. (CONTD.) 1. Type Of Pump Cooling/ Sealing/ 2. Type Of Casing/ Lubrication system with Bowl all accessories 4. 3. Type of Impeller completely piped, 4. Number Of Stages valved & with instruments. 5. Type Of Mounting 5. Discharge Pipe Required 6. 6. Earthing Cleats Submergence 7. Discharge Flange 7. Suction Strainer Drilling Standard 8. Type of Pump- 8. Discharge Pressure Motor Assembly Gauge 9. Impeller Diameter 9. Clamps, Lifting Lugs & Offered Eye Bolts Max. Impeller 10. Diameter that can Pump-Motor coupling/ 10. be accommodated guard in casing 11. Shaft Sealing Arrangement 12. Bearing Lubrication Type 11. Level Switch ON-OFF Pump Foundation 13. base plant MATERIAL OF CONSTRUCTION dimension F. (Material test certificates shall be 14. 15. Discharge Nozzle submitted by pump vendor) orientation Discharge Nozzle, 1. Bowl/Casing mm 2. Suction Bell 3. Impeller E. ACCESSORIES AND SERVICES REQD. 4. Bowl Wearing Ring 5. Impeller Shaft 1. Base Plate & Sole 6. Shaft Sleeves Plate 2. Foundation Bolts, Nuts, Sleeves, etc. 7. Companion 3. Flanges with Nuts, 8. Bolts & Gaskets Seating Plate & Motor Stool Strainer (5 mm opening size)

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 3 OF 4 Sr. Item Description F. MATERIAL OF CONSTRUCTION (Contd.) 9. Base Plate 10. Drive Shaft 11. Shaft Bearing 12. Diffuser 13. Mechanical Seal Nuts 14. Fasteners Bolts G. MOTOR DATA- Refer NPCIL Motor Datasheet PC-E-501 1. Drive motor type 2. Designed for Reverse Rotation H. INSPECTION & TESTING - GENERAL Stage Inspection 1. Yes by Purchaser Material Testing & 2. Yes Identification Dismantling 3. Yes Inspection Sr. Item Description 2 D.P Test a b c Parts to be Checked (100%) Testing Standard Acceptance Standard 3. Ultrasonic Examination a. Parts to be tested (100%) b. Testing Standard c. Acceptance Criteria 4. M.P. Test a. Parts to be tested b. Testing Standard c. Acceptance Standard 5 I.G.C. Test Parts to be tested (100%) I. INSPECTION & TESTING Non Destructive Examination 1. Radiography a. Parts to be tested b. Testing Standard c. Acceptance Standard

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 4 OF 4 Sr. Item Description Sr. Item Description INSPECTION & TESTING J. Performance & Other Tests Required (CHP) Hydrostatic test.- 1. Parts to be tested (100%) Hydrostatic test 2. pressure, kg/cm 2 (g) 3. Impeller Balancing (100%) 4. Shop Performance Tests (100%) 5. Test / Acceptance Standard 6. Strip down Test NOTE: 1. Driver Rating to be selected based on maximum kw required in range upto 120% of rated capacity under 51.5 Hz power supply frequency 2. CHP Customer Hold Point

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 1.0 General a Manufacturer s Name b Model No & Type c Tag No d No of pumps offered e of stages DATA SHEET B (To be filled by Vendor along with the tender) ANNEXURE - B 2.0 Guaranted Performance Data a Design capacity (m 3 /hr) b Total dynamic head at design capacity in mwc c Shut off head in mwc d Pump efficiency e Motor efficiency f Combined pump & motor efficiency g KW requirement at 50 Hz and 51.5 Hz power supply frequency as following format h i j i At rated capacity (specify also tolerance) ii At pump shut off iii At 120% capacity iv Maximum KW requirement v Guaranteed Power Consumption at Motor input terminals at pump duty point, KW Range of operation in terms of flow Range and TDH range Speed in RPM i Synchronous speed of motor ii Specific speed of impellers iii Full load speed for operating condition iv First critical speed Solid handling capacity 50 Hz 51.5 hz 3.0 Construction Features 3.1 Manufacturer a Pump b Motor c Coupling & Type 3.2 Motor details and type Details to be filled in Motor Data Sheet (Data Sheet B of PC-E-501) 3.3 Cable Gland Sealing type 3.4 Number of mechanical seals provided 3.5 Impeller a Type of Impeller

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 2 OF 4 b Diameter of impeller, mm c Direction of rotation viewed from driver end d Method of fastening impellers to shaft e Whether static and dynamic balancing of Impeller will be Yes / No carried out f Suction Strainer 3.6 Shaft and bearings a Shaft diameter, mm b Type of bearing and make, nos i Radial Thrust ii Axial Thrust 3.7 Nozzle Connection a Suction size, mm b Discharge i Size, mm ii Rating iii Facing & Drilling Standard iv Orientation (Top/Side) v Discharge Pipe Size 4.0 Instruments & Accessories 4.1 Method of vertical adjustment of rotor (Details to be enclosed with proposal) 5.0 Weights a Complete pump and drive assembly including cables (Kg) b Motor, Kg (with oil filled and empty) c Total shipping weight (kg) d Moment of inertia with entrained liquid (kg/m 2 ) 6.0 Dimensions a Overall length from top of discharge flange to bottom of pump, mm 7.0 Materials Of Construction a Impeller b Impeller wearing ring c Casing wearing ring d Casing e Column f Shaft g Sleeve h Glands i Stuffing Box j Counter flange k Gland Bolts and Nuts l Bolts and Nuts for discharge connections m Couplings

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 3 OF 4 n o p Sealing arrangement Type of lubrication oil Type of motor cooling oil 8.0 Probabilistic Safety Analysis Input Data : Following data to be submitted a Mean time between failures (MTBF) : b Test Frequency : c Impact of ageing on performance : d of cycles of operation in life time: e Calibration Frequency 9.0 Drawings, Curves and Information Required with Proposal The following information shall be submitted with the proposal. 9.1 Preliminary outline drawings for the complete pump and drive assembly, showing principal dimensions and location of the various connections, supports etc. 9.2 Cross-sectional drawing indicating various components with their materials of construction. 9.3 Performance Curves Performance curves showing the total pump head, efficiency, and power consumption for the range zero to 120% of design capacity. 9.4 Description of the standard shop inspection and quality control procedures of the manufacture separately for pump and motor. Description of the pump performance testing at the shop. 9.5 Speed torque characteristics for pump and motor superimposed on each other. 9.6 Thermal withstand characteristics of the motor. 9.7 Motor data sheets as per Annexure B to specification PC-E-501 applicable. 9.8 Experience list about the supply of similar equipment for similar application. 10.0 DRAWINGS, DATA, INSTRUCTION MANUAL, TEST REPORTS ETC., SCHEDULE OF SUBMISSION The supplier shall submit various certified drawings and data for review of the Purchaser and afterwards for final distribution in quantities and in accordance with the procedure set up in Tendering and Contract conditions, according to the following schedule in respect of each project.

TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 4 OF 4 Description Submission of for Approval after the date of issue of Purchase Order (a) General arrangement drawings of all equipments indicating principal dimensions weeks and locations of the various connections, supports (b) Detailed cross sectional drawing showing all weeks the parts of the equipment (c) Instruction manuals. weeks (d) Reports of various shop and material test, weeks performance (e) Drawing as mentioned in Clause No: 8.0 weeks (f) Inspection history document weeks 11.0 Time Required by the Supplier The contractor shall state the period required for the preparation of his drawings and the time he has allowed for approval of the drawings by the Purchaser in the delivery period specified. 12.0 Proof of Ability The tenderer shall submit a brief list of work executed by him to standards and tolerances as specified in Tender Document. 13.0 Schedule of Deviations If the proposal has got any deviation from the technical specification, the tendering conditions and the general condition of contract, tenderers shall tabulate those deviations as per section D. More sheets should be attached if required. In absence of this it will be presumed that the offer is strictly in accordance with this specification. 14.0 Manufacturing and Delivery Schedule 14.1 Submission of drawings and documents for approval. 14.2 Start manufacture. 14.3 Complete manufacture. 14.4 Testing at manufacturer s works 14.5 Complete shipment. 14.6 Arrival at site. Time in weeks from the Date of Issue of Purchase Order 15.0 Guarantee period offered Months