Analysis O2, CO, CO2. Applications. Characteristics. System. Air monitoring. Measurands O 2, CO, CO 2. Measurement in liquids

Similar documents
Gas concentrations in the air

Differential pressure measuring instrument

Humidity/temperature measuring instrument

VAC measuring instrument

VAC measuring instrument

VAC measuring instrument

Flow - sight glass, flap, ball

VAC measuring instrument

Humidity/temperature measuring instrument

CO2 transmitters. Introduction 44. CO 2 transmitters 45. CO 2 and temperature transmitters 46. CO 2 transmitters for special applications 47-48

Highly efficient flue gas analyzer

Professional flue gas analyzer Testo AG LPG

Sensor Cartridge SC2 for toxic gases and oxygen

Humidity/temperature measuring instrument

Sensor Cartridge SC2 for toxic gases and oxygen

Professional flue gas analyzer

Sensor unit MC2 for toxic gases and oxygen with analog output

Just a few clicks away from a heating system

Just a few clicks away from a heating system diagnosis.

Just a few clicks away from a heating system diagnosis.

Highly efficient flue gas analyzer

Professional flue gas analyzer

Just a few clicks away from a heating system

Drinking Water Monitoring. Ready-to-use systems for monitoring of quality relevant parameters in

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

Pressure and temperature transmitters ATM/T

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

X-Change Gas Sensor Cartridges. PolyGard 2 SC2

Highly efficient flue gas analyzer

Just a few clicks away from a heating system diagnosis.

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Highly efficient flue gas analyser with Bluetooth

SmartTouch. Truly smart flue gas measurement. The new testo 300 flue gas analyser with smart-touch technology.

3. Analytical measurement and testing Oxygen measurement/devices

JUMO tecline Cl2 Sensor for free chlorine

Approved by TÜV according to VDI 2053 for OEM applications with CO monitoring systems for underground car parks

Online data sheet MCS100E HW-C CEMS SOLUTIONS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

testo 335 New measurement engineering for monitoring emissions

Reference thermometer Model CTP5000

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

testo 445 Additional information at Service instrument for ventilation/air conditioning systems

OXITEC Oxygen Analyser Systems. Maximum Efficiency and Supreme Quality for the World Market ENOTEC

System overview. Lambda Transmitter LT2 Lambda Probe LS2 (K) for measurement of oxygen (O 2 ) Sensors and Systems for Combustion Engineering

SEMI-CONTINUOUS EMISSION MONITORING SYSTEM

Highly efficient flue gas analyzer

The ideal service instrument for HVAC systems

TopLine. THE LOW-MAINTENANCE SENSOR SERIES IN PEEK SHAFT - FOR ph AND ORP

Compact flue gas analyser: testo 300 M-I

Flow - sight glass, flap, ball

Measure. Print. testo 310. Flue gas analysis the easy way.

Measure. Print. Done. testo 310. Flue gas analysis the easy way.

Reference flue gas analyzer

Fine particle measuring system

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

Continuous Flow Monitoring. In-situ, low maintenance devices for continuous measurement of hot gas flow

madur GA21p-EN-v portable gas analyser

Multi-function VAC measuring instrument

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

New Measurement Engineering For Monitoring Emissions In Industry

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

Fine particle measuring system

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

HND-F. Hand-held Humidity Precision Measuring Unit % weight moisture % relative humidity. starting with ± 0.1%

EuroFID Total Hydrocarbon Analyzer

EWIKON electric drive valve gate technology. Full process control with high precision

MRU FOR PROFESSIONAL MEASUREMENTS

PRODUCT CONFORMITY CERTIFICATE

Presented By. NicolScales.com Contact Us

Using the PPM2 Portable Trace Moisture Transmitter

Portable Infrared Flue Gas Analyzer Gasboard 3800P

testo 330 Flue gas analysis with increased convenience and safety

Load cell Pendeo Process and mounting kits

New Measurement Engineering For Monitoring Emissions In Industry

Cutting-edge technology for professional air conditioning engineers

PRODUCT CONFORMITY CERTIFICATE

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Online Gas Analyzer / Monitor

INSTALLATION INSTRUCTION IM 317 E

OXITEC O 2. InSitu analyser systems DEVELOPED AND MANUFACTURED IN GERMANY

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

SERIES 60 DETECTORS-TRANSMITTERS FOR FLAMMABLE, TOXIC GASES AND OXYGEN ATEX. Your environment, your safety, let s master them together

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Model Product Description and Specifications

PRODUCT CONFORMITY CERTIFICATE

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

Diaphragm pressure gauge

New Measurement Engineering for Heating Fitters and Technicians

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Flue gas analyzer for industry

madur portable gas analyser

Transcription:

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de Analysis System Analysis oxygen, carbon monoxide and carbon dioxide Measurands O 2, CO, CO 2 in air / gases O 2 (dissolved O 2) in liquids Applications Air monitoring Underground and parking garages Factory and office rooms Storage rooms Garages Green houses Measurement in liquids Aquaristics Fish farming measurement of spring and well water pi-gr-co-co2-o2_e V2.00-00 1

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de Function Oxygen (O 2), carbon monoxide (CO) and carbon dioxide (CO 2) measurements are mainly used for ambient air monitoring. CO 2 and O 2 are important indicators for ambient air quality and therefore important for modern climate control. The recommended CO 2 limit for indoor air is 1000 ppm. Concentrations considerable above this limit causes fatigue and poor concentration. At values considerably lower than that limit there is a high energy saving potential at the climate control with optimized air change rates. Advantages Robust ABS housing Suitable for wall mounting On-site display and operating buttons Electric connection via elbow-type plug Transmitter incl. electrode, sensor or measuring cell Extensive range of accessories and spare parts Air is composed of approximately 21% O 2 and 78% nitrogen, beyond that it contains approximately 0.04% CO 2 and other components. CO is a toxic gas that is produced by incomplete combustion of fossil fuels. This gar is normally measured in underground and parking garages and motor vehicle workshops. The oxygen measurement in liquids serves the monitoring of spring and well water quality as well as checking the water quality for fish farming. Device Overview Type Measurand Description Measuring range Page OXY 3690 MP O 2 Air oxygen transmitter incl. sensor OXY 3610 MP O 2 Transmitter incl. sensor for dissolved oxygen in liquids Oxygen concentration: 0.0..100.0 % O 2 3 Oxygen concentration: 0.00..25.00 mg/l (dissolved) GT1-CO CO CO-transmitter Carbon monoxide: 0..300 ppm CO GT10-CO2-1R CO 2 CO 2-transmitter Carbon dioxide: 0..2000 ppm CO 2 or 0..5000 ppm CO 2 6 Mistakes reserved, technical specifications subject to change without notice. 4 5 2 pi-gr-co-co2-o2_e V2.00-00

GHM GROUP - Standort Greisinger GHM Messtechnik GmbH Hans-Sachs-Straße 26 93128 Regenstauf GERMANY Phone +49 9402 9383-0 Fax +49 9402 9383-33 www.greisinger.de info@greisinger.de Air Oxygen Transmitter incl. Electrode OXY 3690 MP O 2-sensor element GOEL 370 Measuring range 0.0..100.0 % O 2 Response time T 90 Application < 10 s for air or pure oxygen or for air or air with high CO 2-concentration GOEL 380 Measuring range 0.0..25.0 % O 2 Response time T 90 < 5 s Application for air with little CO 2-concentration, response time shoots Temp. compensation : integrated in oxygen sensor Connection cable : 1.3 m with 5-pole screw-able diode plug Working pressure : 500..2000 hpa (static) for air or gas inflow option GOO (oxygen probe GOO / MU) is needed Dimensions O 2-sensor element exchangeable Appropriate to air with high CO 2-concentrations Input electrically isolated The OXY 3690 MP measures the oxygen concentration in air. Depending on the selected design type the device is appropriate to either pure oxygen (i.e. low CO 2 concentration) or to air with very high CO 2 concentration. Measuring probe Ordering code : Ø 40 x 103 mm (153 mm incl. bend protection) Technical data Measuring range Oxygen concentration : 0.0..100.0 % O 2 Temperature : -20.0..+50.0 C Accuracy (transmitter) at 20.9 % O 2, 1000 mbar abs. Oxygen : ±0.1 % ± 1 digit Temperature : ±0.1 C ±1 digit Output signal (only O 2) : 4..20 ma (2-wire) 0..10 V (3-wire) Electrical isolation : input electrically isolated Working temperature : 0..50 C Power supply : 12..30 V DC at 4..20 ma 18..30 V DC at 0..10 V Permissible impedance : R A [Ω] = (U V [V] - 12 V) / 0.02 ma Permissible load : R L > 3000 Ω Reverse voltage protect.: 50 V permanent Display : 10 mm high, 4-digit LCD display Electric connection : elbow-type plug (EN 175301-803/A), max. wire cross-section: 1.5 mm², wire diameter from 4.5..7.0 mm Sensor connection : 5-pole screw-able diode socket Calibration : 1-point-calibration at atmospheric air Air pressure compensat.: 500..2000 hpa abs., manual input Over- / under-pressure : max. 0.25 bar Housing : ABS 1. 2. 3. 4. OXY3690MP - - - - 1. O 2-sensor element 0 GOEL 370 for air and pure oxygen 1 GOEL 380 2. Sensor design GGO closed sensor design (suited for over- and under- pressure, used at gas-tight systems) GOO open sensor design (e.g. suitable for air or gas inflow, pressure cannot be built up) 3. Output signal A1 4..20 ma (2-wire) V2 0..10 V (3-wire) 4. Cable length L01 1.3 m cable L10 10 m cable Ordering example: OXY3690MP-0-GGO-A1-L01 Accessories / Spare parts GOEL 370 Spare sensor element pi-gr-co-co2-o2_e V2.00-00 3

GHM GROUP - Standort Greisinger GHM Messtechnik GmbH Hans-Sachs-Straße 26 93128 Regenstauf GERMANY Phone +49 9402 9383-0 Fax +49 9402 9383-33 www.greisinger.de info@greisinger.de Transmitter incl. Electrode for Dissolved Oxygen in Liquids OXY 3610 MP Sensor connection : 5-pole screw-able diode socket Calibration : 1-point-calibration at atmospheric air Housing : ABS O 2-electrode (GWO 3600 MU) Electrode : active diaphragm type with integrated NTC resistance Response time : 95 % in 10 s, depending on temperature Working pressure : max. 3 bar Inflow velocity : min. 30 cm/s Connection cable : 4 m with 5-pole screw-able diode plug Dimensions O 2-electrode exchangeable Electrode: active diaphragm type with integrated NTC resistance Input electrically isolated The OXY 3610 MP measures the oxygen concentration in liquids. The device can be used in aquaristics, fish farming as well as for the measurement of spring water and well water. Technical data Measuring range Oxygen concentration : 0.00..25.00 mg/l (solved) Temperature : 0.0..50.0 C Accuracy (transmitter) Oxygen : ±1.5 % of meas. value ±0.2 mg/l Temperature : ±0.1 C ±1 digit Output signal (only O 2) : 4..20 ma (2-wire) 0..10 V (3-wire) Electrical isolation : input electrically isolated Working temperature : 0..50 C Power supply : 12..30 V DC at 4..20 ma 18..30 V DC at 0..10 V Permissible impedance : R A [Ω] = (U V [V] - 12 V) / 0.02 ma Permissible load : R L > 3000 Ω Reverse voltage protect.: 50 V permanent Display : 10 mm high, 4-digit LCD-display Electric connection : elbow-type plug (EN 175301-803/A), max. wire cross-section: 1,5 mm², wire diameter from 4.5..7.0 mm Oxygen probe Ordering code 1. 2. OXY3610MP - - 1. Output signal A1 4..20 ma (2-wire) V2 0..10 V (3-wire) 2. Cable length L04 4 m cable L10 10 m cable L30 30 m cable Ordering example: OXY3610MP-A1-L04 Accessories / Spare parts GWO 3600 MU Spare electrode with 4 m cable GSKA 3600 : diameter Ø: 12.0 ±0.2 mm installation length: 110 mm overall length: 220 mm incl. bend protection Protection cab for measuring in great depths GWOK 01 Spare diaphragm head 4 pi-gr-co-co2-o2_e V2.00-00

GHM GROUP - Standort Greisinger GHM Messtechnik GmbH Hans-Sachs-Straße 26 93128 Regenstauf GERMANY Phone +49 9402 9383-0 Fax +49 9402 9383-33 www.greisinger.de info@greisinger.de CO Transmitter GT1-CO Dimensions Ordering code GT1-CO - 1. TÜV certification according to VDI 2053 Long-lasting electrochemical measuring cell Automatic zero calibration The GT1-CO is a high-quality and TÜV certified CO transmitter (incl. measuring cell) for detection of carbon monoxide in underground and parking garages, boiler plants, heating systems, garages as well as in ambient air. The GT1-CO has a very long-lasting electrochemical measuring cell. It can be easily integrated in existing CO surveillance systems (without loss of validity of existing TÜV certificates). Displays, controller and alarm devices can be connected via 2-wire system without difficulty. Technical data Measuring range : 0..300 ppm CO (carbon monoxide) Measuring principle : electrochemical, permanent measuring Reproducibility : < 3 ppm according to VDI 2053 Response time T 90 : < 60 s Cross sensitivity : 2 % of 300 ppm CO Linearity error : 2 % of 300 ppm CO Offset adjustment : automatic Output signal : 4..20 ma, 2-wire Working temperature : -10..+40 C Power supply : 12..28 V DC (at option VO: 16..26 V DC) Permissible burden : R A [Ω]=(U V [V] - 12 V or 16 V) / 0.02 A Electric connection : elbow-type plug (EN 175301-803/A), max. wire cross section: 1.5 mm², wire diameter from 4.5..7.0 mm Housing : ABS 1. Option 00 without option VO on-site display Ordering example: GT1-CO-00 Accessories GZ-01 Test gas cap GT (for controlled flow with test gas) GZ-02 Gas bottle with 12l test gas: 30 ppm CO GZ-03 Gas bottle with 12l test gas: 300 ppm CO GZ-04 Gas valve unit MiniFlo for 12l gas bottles pi-gr-co-co2-o2_e V2.00-00 5

GHM GROUP - Standort Greisinger GHM Messtechnik GmbH Hans-Sachs-Straße 26 93128 Regenstauf GERMANY Phone +49 9402 9383-0 Fax +49 9402 9383-33 www.greisinger.de info@greisinger.de CO 2 Transmitter GT10-CO2-1R Permissible burden Permissible load Display Electric connection Housing Dimensions : R A < 200 Ω : R L > 3000 Ω : 10 mm high, 4-digit LCD-display : elbow-type plug (EN 175301-803/A), max. wire cross section: 1.5 mm², wire diameter from 4.5..7.0 mm : ABS Ordering code Excellent long term stability Auto-calibration procedure Output signal freely scalable The high-quality and precise CO 2 transmitter works according to the infrared principle (NDIR). An auto-calibration procedure compensates aging effects. This ensures the the excellent long-term stability of this transmitter. Due to the fact that CO 2 is an important indicator for air quality in rooms, it is very important for modern climate control to measures the CO 2 content. 1. 2. GT10-CO2-1R - - 1. Measuring range MB1 MB1: 0..2000 ppm CO 2 MB2 MB2: 0..5000 ppm CO 2 2. Output signal A1 4..20 ma (3-wire) V1 0..1 V (3-wire) V2 0..10 V (3-wire) Ordering example: GT10-CO2-1R-MB1-A1 Due to the freely adjustable output signal the transmitter can be used for nearly each existing controller input. Additionally, there is an on-site display which shows beside the current CO 2 concentration the minimum and maximum values as well as an optical alarm. Technical data Measuring range MB1 : 0..2000 ppm CO 2 MB2 : 0..5000 ppm CO 2 Measuring principle : infrared principle (NDIR) Accuracy MB1 : ±50 ppm ± 2 % of meas. value MB2 : ±50 ppm ± 3 % of meas. value Output signal (only O 2) : 4..20 ma, 0..1 V, 0..10 V (3-wire) Working temperature Power supply : -10..+50 C : 12..30 V DC at 4..20 ma and 0..1 V 18..30 V DC at 0..10 V max. 600 ma 6 pi-gr-co-co2-o2_e V2.00-00

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de pi-gr-co-co2-o2_e V2.00-00 7

GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de Product Overview Laboratory Instrumentation Industrial Sensors and Instrumentation Industrial Electronics Displays / Controller Transmitter / Signal conditioning Isolating converters Safety and Monitoring Devices Power Electronics Calibration and Testing Process Instrumentation Hygienic Design GHMadapt Temperature Flow Level / Filling Height Analysis Measuring Data Acquisition Data Logging and Monitoring Test Bench Measurement Technology Renewable Energies 8 pi-gr-co-co2-o2_e V2.00-00