Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

Similar documents
J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS

J41 Reinforced bitumen membrane roof coverings

NBS SECTION J41 - SCOPE OF WORKS

J41 Reinforced bitumen membrane roof coverings

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to Felt (Waterproofing Only)

LIQUID APPLIED WATERPROOF ROOF COATINGS

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

J42 Specification. Suggested Sarnafil J42 Specification for: Example - Adhered PVC Specification (G410-ELF - Fleece Backed) Our Reference:

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

NBS SECTION J42 - SCOPE OF WORKS

roofing ROOFING Design of the base ROOFING DETAILS

Outline Specification. Protec System Warm Roof. (New Build 0.18 W/m 2 K) (PU Bonded)

LIQUID APPLIED WATERPROOF ROOF COATINGS

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

RUBBERGUARD LIQUID APPLIED WATERPROOFING

4422WT SEALCO ECOTUFF TPO SUPERROOF WATERPROOFING MEMBRANE

Sheetseal GR RIW. Sheetseal GR

Tecnatorch SBS Roof Waterproofing System

Euroroof +44 (0)

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

Euroroof +44 (0)

4422WT SEALCO ECOROOF ECOTUFF TPO GREEN ROOF WATERPROOFING MEMBRANE

Gas Protection System Components

NURAPLY 3PM ROOFING MEMBRANE INSTALLATION CHECKLISTS

4422WE SEALCO EPIROOF & EPISPAN EPDM MEMBRANES

Roofing System. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY AND COLD LIQUID APPLIED WATERPROOFING

Sarnavap 5000E SA Vapour Control Layer

tra-load Tanking Membranes Product and Systems Overview

A WARM ROOF CONCEPT INCORPORATING A ROOF GARDEN WITH A TWO LAYER DUO LANDSCAPE WATERPROOFING SYSTEM.

June Non - Residential Refurbishment 5.5 Basements

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

FUNCTIONAL REQUIREMENTS

SOPREMA JARDIN Double Layer Torch-on membrane For water proofing roof gardens and planters

Flat roofs. Flat roof design. 2.3 Flat Roofs

June Residential Refurbishment Basements

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Sheetseal 226 RIW. Sheetseal 226

Enviroflex Liquid-Applied Roof Waterproofing

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

TR26 LPC/FM / TR27 LPC/FM

GRP Flat Roofing Edge Trims

50948-RHN Putney. 06 January This document includes: F30. Accessories/ sundry items for brick/ block/ stone walling. Code Section Revision Dated

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

Outline Specification. Protec System to PVC Single-Ply Membrane (Waterproofing Only)

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

Garage Conversion - Between and Under Joist Applications

Enviroflex. The User Friendly. Liquid-Applied Roof Waterproofing. Solution. Sealoflex

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

TR26 LPC/FM / TR27 LPC/FM

Soffit Board. Insulation

Suspended timber upper floors

Polyfoam Floorboard For thermal insulation of floors

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Detail Sheet 1 / Ballytherm BTF Floor Insulation

Self Adhesive EPDM TRAINING MANUAL

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

tra-load Damp Proof Courses Product and Systems Overview

KINGSPAN THERMAROOF TR21

Outline Specification. Protec System to New OSB3 (TG4) Deck (Warm Roof)

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Balcony & Terrace System

RENOLIT ALKORPLAN L Loose laid & ballasted system

FLEXITHERM Double layer with Graphite Core Insulation

RECOMMENDED DESIGN SPECIFICATION

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

TR27 LPC/FM. Insulation

Dow Building Solutions Insulating lightweight inverted roofs with STYROFOAM Solutions

Pre-Installation Checklist / Warranty Guidelines

TR27 LPC/FM. Insulation

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

Light-Metal Roof Edge, Raised

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Flat Roofing. Product Guide. Traditional Felt. Pour & Roll Membranes. Torch Applied Membranes. Self-adhesive Membranes

Flat Roofing. Product Guide. Traditional Felt. Pour & Roll Membranes. Torch Applied Membranes. Self-adhesive Membranes

Certificate No: EWS526

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

CI/SfB Oct 12. (47) Ln. Uniclass L524. System HIGH PERFORMANCE, TORCH-ON ROOFING SYSTEM RESILIENT, FLEXIBLE, LONG LASTING

ITEM 458 WATERPROOFING FOR STRUCTURES

April Section 5. Basements

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen

TORCH-FREE BITUMEN MEMBRANE DETAILING

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

K11 Roofboard. I n s u l a t i o n. Low Energy Low Carbon Buildings

Transcription:

Project reference: 010050 Specification Written: by: Cathal Quinn Email: cathal@moymaterials.com Tel: 07788 934895 Project Name: Moy Materials Victoria House (4 th Floor) Victoria Road Chelmsford CM1 1JR

February 2013 Moy Materials Ltd J41 REINFORCED BITUMEN MEMBRANE ROOF COVERINGS To be read with Preliminaries/ General conditions. TYPES OF ROOF COVERING F.M. GLOBAL APPROVED SYSTEM 110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING CLASS 1 I-90 STANDARD. - Substrate: Joriside profiled galvanised steel deck laid to falls. Gauge min. 0.75. - Preparation: Clean surface & remove debris. - Vapour control layer: Permate Ultra F.M. foil laminate vapour barrier. - Insulation: Paratherm F.M. PIR rigid roof board by Moy Materials Ltd. - Overlay to insulation: Eraboard S 20mm F.M. Perlite coverboard. - Waterproof covering: - System manufacturer: Imper Italia. - First layer: 3mm Top/S modified bitumen F.M. reinforced base sheet. - Intermediate layer: N/A. Attachment: N/A. - Top layer/ Capsheet: 4mm Paralon Ard/S granular surfaced F.M. modified bitumen 4.5kg cap sheet. Colour: Anthracite. - Flashings and detail work: Install as per manufacturers typical details and architects drawing to F.M. Standard. 4470. - Surface protection: Paralon Ard/S granular walkway membrane where specified. - Accessories: Harmer cast aluminium roof outlets, Ital Profili pipe collars and cowls as per drawings. 130 BUILT-UP REINFORCED BITUMEN MEMBRANE COLD DECK ROOF COVERING AGRÉMENT CERTIFIED SYSTEM. - Substrate: Plywood concrete recover. - Preparation: Prime with Impertene Primer. - Waterproof covering: - System manufacturer: Imper Italia. - First layer: 3mm Top/S modified bitumen reinforced base sheet. - Intermediate layer: N/A. Attachment: N/A. - Top layer/ Capsheet: 4mm Paralon Ard/HS granular surfaced Agrément Certified modified bitumen 4.8kg cap sheet. Colour: Select. - Flashings and detail work: Install as per Moy Materials Ltd typrical details and architects drawings. - Surface protection: N/A. - Accessories: Harmer or Ital Profili roof outlets.

PERFORMANCE 210 ROOF PERFORMANCE - General: Secure, free draining and weathertight. 225 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS - Determine: Interstitial condensation risk of roof construction as recommended in BS 5250, annex D. - Vapour control layer: If necessary, provide a suitable membrane so that damage and nuisance from interstitial condensation do not occur. 230 INSULATION - Requirement: Determine type and thickness of insulation and integral or separate overlay to satisfy the following criteria: - Thermal transmittance of roof (maximum): To meet current regulations. - Compressive strength of insulation (minimum) at 10% compression: 32kg. - Finished surface: Suitably even, stable and robust to receive roof covering. - Insulation compliance: To relevant British Standard, or Agrément certified. 240 ATTACHMENT OF ROOF COVERING - Requirement: Determine methods of attachment to resist wind loads. Provide for relative movement of materials and effects of vapour pressure. Do not reduce performance of vapour control layer. - Wind loads: Calculate to BS 6399-2, Standard Method or Eurocode Standard or FM Global windstorm project classification PRODUCTS 322 PRIMER - Type: Bitumen. - Manufacturer: Imper Italia. - Product reference: Impertene. 335 ANGLE FILLETS - Material: Paratorch or Perlite. - Size (minimum): 50mm. - Restriction: Fillets under torch-on bitumen membranes to be non-combustible. 345 PERIMETER TRIMS - Type: GRP or aluminium. - Manufacturer: Areco. - Product reference: AF. - Colour: Select. - Size: Select. - Lengths (maximum): 3 m.

395 VAPOUR CONTROL LAYER - Type: Foil laminate or bitumen. - Manufacturer: Lexcor or Imper Italia. - Product reference:. - Thickness: 2 ply or 3kg. - Vapour resistance: Good to positive. 430 WARM DECK ROOF INSULATION - Type: Roofing grade. - Manufacturer: Kingspan / Moy Materials Ltd. - Product reference: Paratherm / Paratorch. - Grade: PIR. - Edges: Square. - Thickness: To meet current U-Value. - Facing: Tissue, foil or bitumen. 455 PERLITE OVERLAY TO WARM DECK ROOF INSULATION - Standard: To EN 13169 - Manufacturer: Sitek. - Product reference: Eraboard S. - Grade: Perlite. - Thickness: 20mm. 480 PIPE COLLARS & COWL - Manufacturer: Ital Profili. - Product reference: Dutral Article 114 or D57. - Size: Variable. 485 ROOF VENTILATORS - Manufacturer: Ital Profili. - Product reference: Dutral Article 49. - Size: 110. EXECUTION GENERALLY 515 ADVERSE WEATHER - General: Do not lay coverings in high winds, wet or damp conditions or in extremes of temperature unless effective temporary cover is provided over working area. - Unfinished areas of roof: Keep dry. Protect edges of laid membrane from wind action. 520 INCOMPLETE WORK - End of working day: Provide temporary seal to prevent water infiltration. - On resumption of work: Cut away tail of membrane from completed area and remove from roof. 530 APPLYING PRIMERS - Coverage per coat (minimum): 4m² / litre.

- Surface coverage: Even and full. - Coats: Fully bond. Allow volatiles to dry off thoroughly between coats. SUBSTRATES/ VAPOUR CONTROL LAYERS/ WARM DECK ROOF INSULATION 610 SUITABILITY OF SUBSTRATES - Substrates generally: Secure, clean, dry, smooth, free from frost, contaminants, voids and protrusions. - Preliminary work: Complete including: - Grading to correct falls. - Formation of upstands, kerbs, box gutters, sumps, grooves, chases and expansion joints. - Fixing of battens, fillets and anchoring plugs/ strips. - Moisture content and stability of substrate: Must not impair roof integrity. 670 LAYING VAPOUR CONTROL LAYER - Attachment: Securely bond or nail to substrate. - Side and end laps: 100mm min. - Joints in second layer (where applicable): Stagger by half a membrane. - Penetrations: Fully seal using bonding or taping methods recommended by manufacturer. - Edges of insulation at roof edges, abutments, upstands, kerbs, penetrations and the like: Enclosed with vapour control layer: - Dressed up sufficiently, providing 50 mm (minimum) seal when overlapped by the roof covering; or - Turned back 150 mm (minimum) over the insulation and sealed down. 680 LAYING WARM DECK ROOF INSULATION - Setting out: - Long edges: Fully support and run at right angles to parapets. - End edges: Adequately support. - Joints: Butt together. - End joints: Stagger. - Bedding: Full bed of bonding compound. - Mechanical fixing: To BS Std. or Eurocode Std. or FM Global windstorm classification. - Protection to exposed edges of insulation: Reduced thickness treated timber batten, outer edge chamfered at changes in level. - Completion: Boards must be in good condition, well fitting and stable. 690 LAYING OVERLAY TO WARM DECK ROOF INSULATION - Setting out: Stagger to break joint with insulation. - Joints: Butt together. - Bedding: Full bed of bonding compound. - Mechanical fixing: To F.M. Global or Eurocode Std. WATERPROOF MEMBRANES/ ACCESSORIES

740 TORCH-ON BONDING OF REINFORCED BITUMEN MEMBRANES - Bond: Full over whole surface, with no air pockets. - Excess compound at laps of top layer/ capsheet: Leave as continuous bead. 747 SELF-ADHESIVE BONDING OF REINFORCED BITUMEN MEMBRANES - Bond: Full over whole surface, with no air pockets. COMPLETION 910 INSPECTION - Interim and final roof inspections: Submit reports. 920 ELECTRONIC ROOF INTEGRITY TEST - Testing authority: As instructed by architect. - Timing of test: On completion of cap sheet. - Condition of roof prior to testing: - Complete to a stage where integrity can be tested. - Surface: Clean. - Test results and warranty: Submit on completion of testing. 940 COMPLETION - Roof areas: Clean. - Outlets: Clear. - Work necessary to provide a weathertight finish: Complete. - Storage of materials on finished surface: Not permitted. - Completed membrane: Do not damage. Protect from chemicals, traffic and adjacent or high level working.