Comparison of static and high strain dynamic tests on driven steel piles at several industrial sites in Alberta

Similar documents
Driven pile capacity for wind farms in western Ontario, Canada

Formation of soil plugs within H-Piles driven in stiff clayey Port Stanley till near London, Ontario

Torque correlation for solid steel square shaft helical piles

Torque correlation for solid steel square shaft helical piles

In-situ loading tests of small-diameter helical piles and evaluation of design methods

Experimental study on axial and lateral bearing capacities of nonwelded composite piles based on pile load test results

Pile load tests for helical piles in oil sands site near Fort McMurray, Alberta

NPTEL Course GROUND IMPROVEMENT USING MICROPILES

353. Fellenius, B.H., The response of a "plug" in an open-toe pipe pile Geotechnical Engineering Journal of the SEAGS & AGSSEA 46(2)

Helical piles - An effective foundation system for solar plants

In-situ Axial Load Tests of Drilled Displacement Steel Piles

Thus, the author s third conclusion, to be clear, should refer to downdrag and not to negative skin friction.

Observed Performance of Long Steel H-Piles Jacked into Sandy Soils

Comparative Study between Design Methods and Pile Load Tests for Bearing Capacity of Auger-drilled PHC Piles

Foundation Innovations Ensure Successful Bridge Replacement

Estimation of in-situ water content, void ratio, dry unit weight and porosity using CPT for saturated sands

Evolution of Pile Shaft Capacity over Time in Soft Clays Case Study: Leda Clay

Evaluation of negative skin friction on sheet pile walls at the Rio Grande dry dock, Brazil

The Bearing Capacity of Soils. Dr Omar Al Hattamleh

339. Massarsch, K.R and Fellenius, B.H., Ground vibrations from pile and sheet pile driving. Part 1 Building Damage. Proceedings of the DFI-

Deflection of Helical Piles: A Load Test Database Review

The effect of subsurface volume loss on the bearing capacity of reinforced granular material

PILED RAFT DESIGN PROCESS FOR A HIGH-RISE BUILDING ON THE GOLD COAST, AUSTRALIA

Typical set up for Plate Load test assembly

A Case History of Pile Freeze Effects in Dense Florida Sands

STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN

Evaluation of PDA Data to Identify Pile Issues Presented at Annual KC Specialty Seminar January 9, 2015

Conference: IFCEE International Foundations Congress and Equipment Exposition

Subsoil Bearing Capacity from Load Test Results In Two Locations in Rivers State, Nigeria

STATIC AND HIGH STRAIN DYNAMIC TEST CO-RELATION STUDIES ON CAST-IN-SITU CONCRETE BORED PILES

A Case Study: Foundation Design in Liquefiable Site

THE EFFECT OF STRESS STATE ON THE SOIL-WATER CHARACTERISTIC BEHAVIOR OF A COMPACTED SANDY- CLAY TILL

Proceedings of the ASME nd International Conference on Ocean, Offshore and Arctic Engineering OMAE2013 June 9-14, 2013, Nantes, France

USE OF DIPP PILES FOR A NEW SUP BRIDGE IN WEST MELBOURNE

Offshore pile acceptance using dynamic pile monitoring

MURPHY'S LAW AND THE PILE PREDICTION EVENT AT THE 2002 ASCE GEOINSTITUTE'S DEEP FOUNDATIONS CONFERENCE

Dynamic Pile Load Testing. James A. Baigés, PE September 3, 2015

foundations Dr Trevor Orr Trinity College Dublin Convenor TC250/SC7/EG3 Eurocodes: Background & Applications June 2013, Dublin

Analysis of Four Load Tests on Augered Cast-in-Place Piles in the Texas Gulf Coast Soils Raghu Dass, PE, Woodward Vogt, PE, and Frank Ong, PE

Pile foundations Introduction

DESIGN OF PILE FOUNDATIONS FOR THE SAND CREEK BYWAY, SANDPOINT, IDAHO

A design approach for piles in langley clay based on pda testing

SEISMIC SOIL-PILE GROUP INTERACTION ANALYSIS OF A BATTERED PILE GROUP

Bridge pier movements induced by micropile installations

LADOTD DRIVEN PILE DESIGN & VERIFICATION. Jesse G Rauser, PE USING LRFD

Application of Vibro Techniques for Infrastructure Projects in India

On-site determination of pile capacity Distribution of pile load between the shaft and tip, and Detection of possible pile.

Bi-Directional Static Load Testing of Driven Piles

BORED MICROPILES. I.S.M 2009 London (10 th to 13 th may) 9 th International worksop on micropiles - by A. Jaubertou -

STATNAMIC LOAD TESTING OF HIGH CAPACITY MARINE FOUNDATIONS

Innovative Deep Foundation Support using Ductile Iron Piles

The Compression Bearing Capacity of Helical Piles in Black Cotton Soil

Behaviour of jacked and driven piles in sandy soil

CHAPTER 11 SUMMARY AND CONCLUSIONS

SAVINGS FROM TESTING THE DRIVEN-PILE FOUNDATION FOR A HIGH-RISE BUILDING

Settlement study of a Singapore 43-storey tower comparing equivalent block model with embedded piles model in 3D finite element analyses

A residual is generally a quantity left over at the end of a process. Geol: that remaining after soluble elements have been dissolved and removed

Experimental study on axial and lateral bearing capacities of nonwelded composite piles based on pile load test results

Pile Setup. Muhannad T. Suleiman, Kam Ng and Sri Sritharan

DEPTH EFFECTS AND VIBRATIONS ASSOCIATED WITH DYNAMIC COMPACTION CASE STUDY

Earth Mechanics, Inc. Geotechnical & Earthquake Engineering

VARIATION OF CAPWAP RESULTS AS A FUNCTION OF THE OPERATOR

Effect of various treatments on consolidation of oil sands fluid fine tailings

Overburden Effect on the Axial Resistance of Instrumented CFA Piles. Knoxville, TN 37922, ph ,

Comparison of modeling methods of drilled shaft foundation for seismic design

Pile Setup, Dynamic Construction Control, and Load and Resistance Factor Design of Vertically- Loaded Steel H-Piles

RECENT ADVANCES IN THE DESIGN OF PILES FOR AXIAL LOADS, DRAGLOADS, DOWNDRAG, AND SETTLEMENT. ASCE and Port of NY & NJ Seminar, April 22 and 23, 1998

An Experimental Study on Vertically Loaded Driven and Cast- In-Situ Piles

Performance of high capacity jack-in pile for high-rise building with preboring in weathered sedimentary rock formation

Modeling and Observations of Pile Installation using Vibro Hammers in Fraser River Delta Soils

Overview of The Role of Testing and Monitoring in the Verification of Driven Pile Foundations

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

Steel screw settlement reduction piles for a raft foundation on soft soil

twenty six concrete construction: foundation design ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013

Axially Loaded Behavior of Driven PC Piles

Downloaded from Downloaded from /1

THEORETICAL AND ACTUAL BEARING CAPACITY OF DRIVEN PILES USING MODEL PILES IN SAND

3.1 Scope of the work-capacity Estimation of Drilled Shaft Bearing on Rock

Performance of Bituminous Coats for Dragload Reduction in Precast Piles

INTERPRETATIONS OF INSTRUMENTED BORED PILES IN KENNY HILL FORMATION

Mechanical analysis of soil arching under dynamic loads

Chapter 16 DEEP FOUNDATIONS

CASE HISTORY OF A FIVE-STORY PRINTING PRESS FOUNDATION WITH ZERO MOVEMENT CRITERION

PRE-CAST CONCRETE SEGMENTAL ARCH DESIGN ON PILED FOUNDATIONS

Pile Acceptance A System View

Deep Foundation Testing, Analysis and Consulting Services

Pile Setup in Cohesive Soil. I: Experimental Investigation

Estimation of vertical subgrade reaction coefficient from CPT investigations: applications in Christchurch

JACK-IN PILE DESIGN MALAYSIAN EXPERIENCE AND DESIGN APPROACH TO EC7

Sabah Shawkat Cabinet of Structural Engineering 2017

Canadian Geotechnical Journal. Large Diameter Helical Pile Capacity - Torque Correlations

CASE STUDY: LOAD TRANSFER ANALYSIS ON AN INSTRUMENTED AUGERCAST PILE USING EDC STRAIN GAUGES AND GEOKON REBAR STRAINMETERS

Symposium: 10 th Int. Conf. on Stress Wave Theory and Testing of Deep Foundations, San Diego, 2018

EFFICIENCY OF MICROPILE FOR SEISMIC RETROFIT OF FOUNDATION SYSTEM

Global Journal of Engineering Science and Research Management

PILE LOAD TEST FOR W.R. BENNETT BRIDGE

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to publication record in Explore Bristol Research PDF-document

Ravi Sundaram. Cengrs Geotechnica Pvt. Ltd. Noida A-100 Sector 63, Noida Ph: (O): (M):

Transcription:

Comparison of static and high strain dynamic tests on driven steel piles at several industrial sites in Alberta Robin Tweedie Thurber Engineering Ltd., Edmonton, Alberta, Canada Renato Clementino & Donald Law Thurber Engineering Ltd., Edmonton, Alberta, Canada ABSTRACT This paper describes three case histories where static load tests (SLT) and high strain dynamic tests (HSDT) were conducted on driven steel piles at industrial plant sites in Northern Alberta. The sites involved H-section and pipe piles up to 61 mm diameter driven to depths ranging from 1 m to 4 m, with design loads up to 22 kn. A combination of SLT and HSDT provided information on capacity, distribution of shaft and end bearing resistance, and set-up. HSDT were an economical method of providing quality assurance and confirmation of pile capacities during construction. RÉSUMÉ Cet article décrit trois études de cas, où des essais de chargement statiques (SLT) et des essais de grande déformations dynamiques (HSDT) ont été entrepis sur des pieux battus en acier, sur des sites industriels situés dans le nord de l Alberta. Des pieux de types H, et à section tubulaires ayant des diamtères allant jusqu à 6 mm, ont été battus à des profondeurs variant de 1 m à 4 m, avec des charges de conception allant jusqu à 22 kn. La combinaison des méthodes SLT et HSDT a permit de recuelllir des données sur la capacité, la distribution de la résistance le long du fût et à la pointe ainsi qu au niveau de la mise en place des pieux. De plus, l utilisation de la méthode HSDT s est averé une méthode économique afin de vérifier l assurance de qualité au niveau des installations tout en confirmant les capacities des pieux lors du battage 1 INTRODUCTION Driven steel piles are commonly used for support of industrial plant foundations in Northern Alberta and offer relatively high capacities with ease of installation. Common pile sizes include 25 mm to 36 mm H-section piles and steel pipe piles ranging from 219 mm to 61 mm diameter supporting working loads up to about kn. The piles are frequently installed through thick glacial clay and sand deposits where set-up due to excess pore pressure dissipation following driving results in significant strength gain with time (e.g. Yang and Liang, 29). Economical pile design requires consideration of the set-up in determining long-term capacity. Pile load test programs are an integral part of design and construction and may include Static Load Tests SLT (ASTM 1994) and High Strain Dynamic Tests HSDT (ASTM 2), also frequently referred to as PDA (Pile Driving Analysis) tests. By careful combination of static and dynamic tests, including HSDT tests at End of Initial Drive (EOID) and restrike (RST) valuable information can be obtained on the distribution of shaft friction and end bearing resistance, and also pile set-up with time. HSDT also provides an efficient and economical method of confirming capacities of representative piles during construction. With the introduction of Limit States Design in the National Building Code of Canada (25) the geotechnical resistance factor also increases with the application of representative pile load tests, from.4 to a maximum of.6, thereby providing an increase in factored ULS pile capacity of 25% based on dynamic tests to 5% for static load tests. The pile load tests should be carried out during the design phase to gain most benefit in terms of optimizing pile designs and applying the higher geotechnical resistance factors. This paper describes three case histories where a combination of SLT and HSDT were performed on driven steel piles at industrial plant sites in Northern Alberta. 2 SITE CONDITIONS Table 1 presents a summary of the soil conditions and typical pile sizes used at the three sites. Typical ranges of Standard Penetration Test N values (uncorrected) and Cone Penetration Test tip resistance is provided for the main soil units. Piles included 31 mm H-section piles and pipe piles ranging from 219 to 61 mm, driven to embedment depths ranging from 1 m to 4 m. 3 SITE 1 SAGD OILSAND PLANT SITE Site 1 involved a SAGD (Steam Assisted Gravity Drainage) Central Processing Facility used for bitumen production from oilsand. The plant will be built in several phases ultimately requiring about 1, piles having design loads ranging from about 4 kn to 1 kn. 214

Table 1. Typical site conditions and pile designs. Site General Stratigraphy 1 Glacial Clay Till with Sand and Gravel Layers Typical Soil Properties* SPT N (CPT Q t -Bars) 1-6 (2-6) 2-1 (1-35) Pile Sizes 219 mm to 61 mm pipe Typical Pile Embedment Depths Typical Pile Design Loads (kn) 1 m to 2 m 4-1 2 m - 5 m Fine Sand; 5 m - 15 m Stiff Clay; 15 m - 22 m Clay Till; 22 m - 4 m Sand and Gravel 5-15 (4-8) 5-2 (1-3) 15-5 (4-3) 5-1 (>4) HP31 x 79, 31 x 94 & 31 x 11 273 mm to 61 mm dia. pipe 14 m to 24 m 2-9 3 m - 2 m Clay and Silt; 2 m - 4 m Silt and Sand; 4 m - 6 m Clay Till; 8-2 (1-2) 1-3 (2-15) 1-5 (2-1) *SPT N (Uncorrected) Blows per 3 mm; CPT Cone Penetration Test HP31 x 79 HP31 x 11 61 mm pipe 3 m to 4 m 12-22 Three Static Load Tests (SLT) were conducted on 324 mm dia. pipe piles (P3, P6 and C&E 1) at three different sites. In addition, HSDT were performed on a companion 324 mm pipe pile (P2), and also on two HP 31 x 1 piles and one 61 mm pipe pile. The HSDT were conducted at end of initial drive (EOID) and also at RST after 25 days. All piles were driven to embedment depths of 16 m. The pipe piles were driven open ended and the soil plugs were left inside the piles after driving. The piles were founded in a heterogeneous deposit of very stiff sandy clay till interbedded with compact to very dense sand with occasional very dense gravel layers. The groundwater table is typically about 2 m to 4 m below ground surface. Details and results of the pile load tests are summarized in Table 2. Average mobilized skin friction and end bearing resistance during restrike as interpreted from the HSDT results are presented in Table 3. Following are the main conclusions of the SLT and HSDT results: 1. The capacities of 324 mm dia. pipe piles, as determined by SLT using the Davisson (1972) method, ranged from 262 kn to 39 kn (Figure1). Piles P3 and P6 had comparable capacities of 39 kn and 297 kn, however P6 had a softer response than P3. 2. As a comparison, pile P3 yielded a SLT capacity of 39 kn whereas the companion (adjacent) pile P2 pile yielded a lower capacity of kn by the HSDT method. 3. The capacities of the HP 31 x 11 piles (P1 and P4) as determined by HSDT were about 65% of the equivalent 324 mm dia. pipe pile capacities. The average mobilized shaft friction of the H-section piles was about 5% of the average mobilized shaft friction for the 324 mm pipe pile (P2). The higher shaft friction of the pipe piles is attributed to the greater soil displacement during pile driving resulting in higher normal effective stresses on the pipe (Meyerhof 1976). 4. The HSDT capacity of the 61 mm x 9.5 mm pipe pile (P5) was 32 kn at restrike after 25 days. The average mobilized shaft friction of 74 kpa was lower than that of the adjacent 324 mm pipe pile (P2) and the end bearing resistance was also about one third of the 324 mm pipe pile. This suggests that the soil plug in the larger 61 mm dia. pile was not as effective as that in the smaller 324 mm pipe pile. 5. All piles indicated a significant increase in capacity between EOID and RST after 25 days. The greatest increase of about 78% was noted for the 324 mm pipe pile (P2). The H-section pile capacities (P1 and P4) increased by about 15% to 2%, and the 61 mm pipe pile capacity increased by 14%. Based on the results of the pile load test program, the 324 mm pipe piles were selected as the main pile type. A maximum allowable (working stress) load of 87 kn was specified for a 16 m deep pipe pile, based on a maximum permissible pile top settlement of 6 mm at design load (Figure 1). This provided a factor of safety of greater than 3 based on the SLT results. During construction, HSDT were conducted on about 1 pipe piles to confirm the pile capacities and determine the relationship between End of Initial Drive (EOID) capacity and Long Term Capacity after set-up. Figure 2 presents a summary of the capacities versus time after initial drive for the 324 mm dia. x 16 m long pipe piles. It is noted that the pile capacities derived from SLT were significantly higher than the majority of the HSDT interpreted capacities. Furthermore, the trend of increase in capacity with time is also noted. Comparison of HSDT results on three 324 mm pipe piles at the adjacent well pad site indicated increases in capacity ranging from 44% to 11% between EOID and RST after a set-up period of 9 to 12 days (Figure 2). Figure 3 shows a summary of the pile capacities at RST for pile embedment lengths ranging from 1 m to 17 m. The 215

Table 2. Site 1 Summary of SLT and HSDT results. Pile 1 P1 - HP31 x 11 P2 324 mm dia x 9.5 mm pipe Test Method 2 HSDT HSDT Testing Mobilized Static Resistance Condition 3 Shaft (kn) Toe (kn) Total (kn) EOID 7 6 1,3 RST 9 65 1,55 EOID 9 5 1,4 RST 1,6 9 2,5 P3 324 mm dia. x 9.5 mm pipe HSDT EOID 95 9 1,85 RST - - - SLT 4 - - 3,9 P4 - HP31 x 11 P5 61 mm dia. x 9.5 mm pipe HSDT HSDT EOID 6 8 1,4 RST 75 85 1,6 EOID 1,9 9 2,8 RST 2,26 94 3,2 P6 324 mm dia. x 9.5mm pipe HSDT EOID 9 1,2 2,1 RST - - - SLT - - 2,97 C&E 324 mm diax 9.5mm pipe SLT - - 2,62 1 All Pile Embedment Lengths 16 m / 2 SLT Static Load Test; HSDT High Strain Dynamic Test 3 Restrike taken 25 days after Initial Drive, 4 SLT Interpretation by Davisson (1972) Method Table 3. Site 1 Mobilized skin friction and end bearing resistance at restrike after 25 days. Average Mobilized Skin Friction Mobilized End Bearing Resistance Pile No. Type (kpa) (kpa) P1 HP 31 x 11 47 6,75 P2 324 mm pipe 98 1,9 P4 HP 31 x11 39 8,85 P5 61 mm pipe 74 3,2 set up period at the time of RST of these piles was not constant but ranged from about 2 to 1 days. Also shown for comparison is the specified pile design envelope based on a minimum factor of safety of 2. Several of the HSDT capacities fell below the design envelope with a FOS of 2; however, these HSDT tests were typically taken at about 2 to 3 days after initial drive, and the capacities are expected to increase further with time. Furthermore, the capacities derived from the SLT were consistently higher than those derived from the HSDT. Based on the results of the HSDT, the capacity for 324 mm pipe piles at EOID was conservatively estimated to be about 67% of the Long Term Capacity (i.e. an increase of 5% of the EOID capacity was considered appropriate for Long Term Design) to establish set criteria at EOID and RST. 4 SITE 2 PETROCHEMICAL PLANT Site 2 involved the installation of approximately 18, H-section and pipe piles with typical design (working stress) loads ranging from about 2 kn to 9 kn. The majority of the heavier loaded piles were HP31 x 11 sections driven to practical refusal in very dense sand or hard till at depths ranging from about 2 m to 25 m. A pile load test program was completed at the start of construction to confirm the pile design capacities, and included five SLT s on HP31 x 11 piles and over 1 HSDT tests conducted on HP 31 piles and 58 mm diameter pipe piles. The maximum applied load during SLT ranged from kn to 45 kn on the 31 HP piles driven to practical 216

LOAD (kn) 5 1 2 DISPLACEMENT (mm) 1 2 3 4 5 Qult = 262 kn Qult = 297 kn Qult = 39 kn 6 7 8 SITE 1 Pile P3 Pile P6 C&E 1 Figure 1. Static Load Test Results for 324 mm dia x 16 m long pipe piles SITE 1 STATIC LOAD TESTS 2 1 5 INDIVIDUAL PILE SET-UP CURVES AT EOID AND RST FROM PDA ENVELOPE OF PDA TEST RESULTS ON 324 MM DIA X 16 M LONG PIPE PILES 2 4 6 8 1 12 DAYS AFTER INITIAL DRIVE Figure 2. Capacity versus days after initial drive for 324 mm x 16 m long pipe piles SITE 1 PILE LOAD TESTS STATIC PILE LOAD TESTS 2 1 5 ENVELOPE OF PDA RESULTS DESIGN ENVELOPE BASED ON FOS =2. 1 12 14 16 18 EMBEDMENT LENGTH (m) Figure 3. Capacity versus Length for 324 mm pipe piles 217

refusal at depths of 2 m to 24 m, and kn on the 58 mm diameter pipe pile driven open ended to refusal at a depth of 16 m, as shown on Figure 4. However, the maximum applied loads from the SLT were limited by the load test frame capacity and also the structural pile capacity and none of the piles experienced plunging failure. The maximum applied loads are therefore considered as lower bound values, whereas pile capacities of greater than 5 kn were estimated based on load test interpretation methods in most cases. The allowable pile loads were also dictated by serviceability criteria. Allowable static loads on the H-section piles corresponding to a limiting vertical displacement of 6 mm varied from about 11 kn to 13 kn, and 165 kn for the pipe pile (Figure 4). This provided a factor of safety ranging from about 2.8 to 3.6 for the H-section piles and 2.1 for the pipe pile. The pile designs had already been completed based on theoretical analysis prior to the load testing and were in the order of 84 kn to 9 kn; hence the piles had even higher factors of safety at the working design loads. This emphasizes the value of undertaking the pile load tests during the design phase, when the potential benefits of obtaining higher capacities can be effectively applied to the pile designs. The interpreted pile capacities based on HSDT are plotted versus pile embedment depth in Figure 5 and show an increasing trend of pile capacity with depth. The data set was limited to piles tested at least 2 days after the initial drive. A trend of increasing capacity with time due to set-up is also evident in Figure 6. The SLT results are also plotted on these figures for comparison, and are in all cases higher than the HSDT capacities. The HSDT results confirm a pile capacity of at least for piles tested at RST after 4 days. Part of the reason for the significant range in capacities determined by PDA is that the pile lengths are not constant and hence the basing conditions may vary. A comparison of pile capacities determined by SLT and HSDT on the HP31 and 58 mm diameter pipe piles is provided in Table 4. The pipe piles were driven open ended to practical refusal at depths ranging from 16 m to 24 m. The average mobilized skin friction and end bearing resistance calculated using the results of the HSDT and SLT are also shown in Table 4. The end bearing resistance of the SLT was calculated by subtraction of the shaft resistance obtained from static tension load testing (ASTM 199) undertaken on the same piles. It is noted that the average mobilized skin friction of the pipe piles was higher than the H-section piles, which is similar to the observations at Site 1, and was attributed to greater soil displacement of the pipe section during driving. The difference in capacities obtained between the HP31 x 94 and HP31 x 11 piles is due to the significant increase in the strength of the founding clay till below 18 m, in which the latter piles were founded. The difference between the skin friction mobilized during the SLT on the pipe pile and that calculated from results of the HSDT on the pipe piles is also likely attributable to higher soil strengths with depth. The end bearing resistance determined from SLT is significantly greater than obtained from HSDT, which is believed to be a result of the larger magnitude of displacement, generated during SLT. However, the end bearing resistance developed for the pipe pile is only about one half of that determined for the H-piles using both HSDT and SLT methods. It is suspected that the open ended pile provided a lower resistance than would be the case for a closed end pipe pile. 5 SITE 3 POWER PLANT Site 3 involved a coal fired power plant housing heavy boilers and turbine generators. The boilers and turbines were founded on large mats supported by groups of 61 mm pipe piles driven to depths of up to 4 m, while the building structure was supported on smaller groups of H-section piles driven to depths of up to 35 m. Typical soil strata and properties are shown in Table 1 and consisted of thick clay overlying sand and silt deposits. HSDT were performed on two H-section piles (one 31 x 79 and one 31 x 11) and two pipe piles (61 mm dia. x 12.5 mm pipe) prior to construction (Table 5). Results of the HSDT indicated increases in capacity of 85% for the H-section pile (P3) and 14% for the pipe piles (P2 and P4) between initial drive and RST after 19 days. Results of HSDT on H-section piles during construction are presented in Figure 7. The results indicate a considerable range of capacities, but generally follow a trend of increasing capacity with time similar to the previous two sites and also reported by others (Stevens 24 and Fellenus 22). The average trend line provides a capacity of about 22 kn after 6 days. The trend line was skewed downwards due to a series of lower HSDT results performed on piles located in the Boilerhouse area. Two SLT s were subsequently carried out on production piles in the Boilerhouse area and confirmed a lower pile capacity ( kn and 2 kn for piles P76 and P328, respectively) in this area. The results of the two SLT are included in Figure 7 for comparison. As a result of the SLT, it was decided to downgrade the capacity of the H-section piles in the Boilerhouse and piles were added to achieve a FOS of at least 2. It is believed that the low capacities obtained for both the HSDT and the SLT were affected by the magnitude of pore pressure generation caused by the driving in the large groups of piles, such that the piles had not fully set-up at the time of the SLT. Nevertheless, it was considered prudent to downgrade these piles, as it was not feasible to wait longer and check if additional set up would occur. 6 CONCLUSIONS The case histories demonstrate the importance of combining SLT and HSDT to optimize pile designs. It is most beneficial to undertake the pile load tests during the design phase, 218

LOAD (kn) 5 1 2 4 45 5 58 mm dia.x 16 m lg PIPE PILE REMAINDER ARE HP31x11, 2-24 m LG DISPLACEMENT (mm) 1 15 2 25 3 SITE 2 35 Figure 4. Summary of static load tests for Site 2 5 SITE 2 45 4 TREND OF INCREASING PDA CAPACITY WITH EMBEDMENT DEPTH 2 PDA AND SLT ON SAME PILE PDA HP31 SLT HP31 PDA LESS THAN 2 DAYS AFTER INITIAL DRIVE NOT SHOWN 1 17 18 19 2 21 22 23 24 25 EMBEDMENT DEPTH (m) Figure 5. Capacity versus embedment depth 5 45 TREND OF INCREASING CAPACITY WITH TIME AFTER INITIAL DRIVE 4 PDA AND SLT ON SAME PILE 2 SITE 2 PDA HP31 SLT HP31 1 2 4 6 8 1 12 14 DAYS AFTER INITIAL DRIVE Figure 6. Capacity versus days after initial drive 219

Table 4. Site 2 Summary of HSDT and SLT Results Pile Type (tip depth, m) Test Method 1 Number of Tests Shaft (kn) Average Mobilized Static Resistance Skin End Toe Total Friction Bearing (kn ) (kn) (kpa) (MPa) HP31 x 11 HSDT 2 73 255 935 299 73 9.7 (2 to 25) SLT 3,4 5 195 2 395 69 2.6 HP31 x 94 (18 to 19) HSDT 14 955 134 2295 59 9.9 58 mm dia. x 9.5 mm HSDT 9 2795 95 3745 87 4.7 (16 to 24) SLT 3,5 1 1325 2175 52 1.9 1 SLT Static Load Test; HSDT High Strain Dynamic Test 2 Restrike at least 2 days after Initial Drive. 3 SLT taken as maximum load applied (see text) 4 Estimated from SLT in tension undertaken on two of the piles and pro-rated to the average total load for the five tests 5 Estimated from SLT in tension undertaken on the pile (16 m depth) Table 5. Site 3 Results of HSDT tests at end of initial drive and restrike. Pile No. Test Condition* Embedment Length (m) Mobilized Capacity (kn) Shaft Resistance (kn) P1 - HP 31 x 79 RST (19) 35. 24 215 25 P3 - HP 31 x 11 EOID 35.2 RST (1) 35.2 21 RST (19) 35.2 28 3 P2-61 mm dia. x 12.5 mm pipe EOID 4. 18 3 RST (18) 4.1 43 38 5 P4-61 mm dia. x 12.5 mm pipe EOID 4. 185 145 4 RST (1) 4. 31 28 3 RST (19) 4.1 44 39 5 *EOID End of Initial Drive; RST Restrike (19) 19 days after Initial Drive Toe Resistance (kn) 4 TEST PILE P3 31 X 11 UPPER BOUND TREND LINE AVERAGE TREND LINE 2 1 LOWER BOUND TREND LINE STATICLOAD TESTS 5 SITE 3 1 2 3 4 5 6 7 8 DAYS AFTER INITIAL DRIVE TEST PILE P3 31 X 11 (35m) STATIC LOAD TEST (31x79) Boiler House HSDT HSDT BOILER HOUSE Figure 7. Capacity versus days after end of initial drive (HP31 x 79 and HP31 x 11) 22

when the potential benefits of obtaining higher capacities can be effectively applied to the pile designs. Pile design based on Limit States Design (LSD) in accordance with NBC 25 must satisfy the Ultimate Limit States (ULS) to prevent plunging failure and also Serviceability Limit States (SLS) to maintain tolerable settlement. In the first two case histories, the SLS criteria of limiting individual pile settlements to 6 mm was the governing criteria, and these results were obtained primarily from the Static Load Tests. In fact, no information was obtained on settlement criteria from the Case 3 prior to construction. Pile set-up resulted in significant gain in capacity for all the three cases and was relied upon to achieve the design capacities. Using End of Initial Drive capacities would have been overly conservative and would have required significantly longer piles with commensurate increases in costs. Fellenius (22) and others have stressed the importance of set-up and this needs to be taken into account when organizing and conducting pile load test programs. It is important, when comparing results, that the SLT and HSDT are in temporal agreement and that the pile dimensions, basing conditions, etc, are consistent between the different piles analysed. Furthermore, when the SLT and HSDT are conducted on the same pile, it is preferable to undertake the SLT first as this generally results in less disturbance (and loss of set-up ) to the pile, than would be the case if the HSDT were conducted first. Sufficient wait time is required between tests to allow for adequate set-up and resulting strength gain. Methods are presented in the literature for evaluating the required set-up time (e.g. Skov and Denver 1988) Comparison of pipe pile and H-section pile capacities at the first two sites indicated higher capacities were obtained on the pipe piles for similar sized pipe piles. This is considered to be a result of the greater soil displacement caused from plugging of pipe piles, thereby resulting in higher confining stresses and friction on the sides of the pile (Meyerhof 1976). ASTM 2. D4945 Standard Test Method for High Strain Dynamic Testing of Piles. Annual Book of ASTM Standards, vol. 4.8, pp.981-987 Davisson, M. T. 1972. High capacity piles. Proceeding, Lecture Series, Innovations in Foundation Construction, ASCE, Illinois Section, 52 pp. Fellenius, B.H. 22. Basics of Foundation Design. Production of elib, geoforum.com. Meyerhof, G.G. 1976. Bearing Capacity and Settlement of Pile Foundation. JGED, ASCE, vol. 12, GT3, March, pp. 195-228 (Terzaghi Lecture). National Building Code of Canada 25. National Research Council Canada, Canada Commission of Building and Fire Codes. Skov, R., and Denver, H. 1988. Time dependence of bearing capacity of piles. In Proceedings of the 3 rd International Conference on the Application of Stress-Wave Theory to Piles, Ottawa BiTech Publishers Ltd. Stevens, R. F. 24. The use of dynamic pile testing to interpret soil set-up. Current Practices and Future Trends in Deep Foundations. ASCE Geo. Spec. Pub. No. 125, pp 96-19. Yang, L., and Liang, R. 29. Incorporating setup into load and resistance factor design in sand. Canadian Geotechnical Journal 46; pp 296-35. 7 ACKNOWLEDGEMENTS The authors wish to acknowledge the assistance provided by the staff of Thurber Engineering Ltd during the SLT and HSDT tests. The SLT were conducted by Agra Foundations Ltd, and the HSDT were conducted by Urkkada Technology Ltd. REFERENCES ASTM 1981. D1143 Standard Test Method for Pile Under Static Axial Compressive Load. Annual Book of ASTM Standards, vol. 4.8, pp.93-13 ASTM 199. D3689 Standard Test Method for Individual Piles Under Static Axial Tensile Load. Annual Book of ASTM Standards, vol. 4.8, pp.413-423 221