Beta Attenuation Mass Monitor

Similar documents
Version Certificate: /

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

BX-895 REAL TIME MODULE OPERATION MANUAL

Met One Instruments BAM-1020 PM 2.5 FEM

PM 2.5 Monitoring in the U.S.

SOP OPERATION OF PARTICULATE MATTER INSTRUMENTS CLARK COUNTY DEPARTMENT OF AIR QUALITY. Monitoring Division PROCEDURE NUMBER 400

WBEA Standard Operating Procedure

DustCheck DPM-16. Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5. Sequential sampler

Particulate Matter Seminar

Method No.: 8.06/2.0/M Effective Date: January 4, 2012 Location: ###

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC)

Indoor Air Quality Solutions

Fpollutant-free zero air for analytical

Title: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry

Ambient Air Quality Monitoring

Met One Instruments, Inc UK Report on the Equivalence of the Smart Heated PM 10 BAM-1020

Aeroqual AQY 1. micro air quality monitoring system

Emerging Continuous PM Measurement Technologies

BetaGuard PM Measuring Particulate Continuously

ANALYSIS OF PARTICULATE POLLUTANT (PM 2.5 ) AND GASEOUS POLLUTANT (CO) AT JABALPUR, MP

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

Particulate Monitors and Samplers

BREATHE A LITTLE EASIER WITH TSI

BGI, INC. WALTHAM, MA 02451

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

The Next-Generation Aethalometer Model AE33

Portable Ozone Systems for Survey Monitoring (POMS)

DESCRIPTION OF INTENDED SINGLE SOURCE PURCHASE (PUR 7776)

STATE OF CALIFORNIA AIR RESOURCES BOARD AIR MONITORING QUALITY ASSURANCE VOLUME V AUDIT PROCEDURES FOR AIR QUALITY MONITORING APPENDIX V

Audit Report of SIMAT Particle Monitoring Network

Thirty-Third Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

Ambient Air Monitoring Systems

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Dekati Solutions. Emission Measurements

GRIMM Aerosol Technik Grimm Instrumentation The future of particle measurement Ing. Wolfgang Brunnhuber Environmental Division Manager

Checklist for testing electronic digital indicators with simulated pulses 2/6/08

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

The procurement, qualification and calibration of lab instruments: An Overview

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Title: Standard Operating Procedure for Measurement of Particulate Matter in Ambient Air Using the Partisol 2000H

PIA Technical Standard

Ambient Dust Sampling

LifeTrack technology: detecting all breaks in the cold chain. Introduction:

QUICK START GUIDE. EVM Series Environmental Monitor

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Air Monitoring Plan for Ground Intrusive Activities at the Various PPG Hexavalent Chromium Sites in New Jersey

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Tank Scale Service Checklist

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

SECTION Inline ULTRASONIC FLOW METERS

NYSDEC In-House Discussion: The Implications of Approved Continuous PM 2.5 FEM III Instruments

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

Agilent CSA Spectrum Analyzer N1996A

Yes No N/A. Yes No N/A. Yes No N/A. Yes No N/A

Title: Operation of ACCU System Particulate Matter sampler in Ambient Air in conjunction with the Tapered Element Oscillating Microbalance (TEOM)

Advance PID technology gives resistance to humidity effects

Capital Projects Group Air Terminal Units Specification

THERMAL FLOW MONITOR DESIGN AND PERFORMANCE IN ACID RAIN STACK

Meteorological Information Needs For An Early Site Permit Application

Air Monitoring Directive Chapter 8: Ambient Audit

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

GENERAL TESTING AND REPORTING REQUIREMENTS

ABSTRACT INTRODUCTION

APPENDIX B. Second Quarter 2010 IML Quality Assurance Audit Report

PERFORMANCE OF VAISALA OZONE INTERFACE BOARD OIF411

APPENDIX F. Fourth Quarter 2009 IML Quality Assurance Audit Report

Field and Laboratory Evaluation of an Ozone Sensor

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Installation Qualification/Operational Qualification Protocols and Instructions

Section Belt-Conveyor Scale Systems

testo 320. Combustion analysis in HD High Def & Heavy Duty For Residential & Commercial Applications 1

Greschbachstrasse 3b, Kahlsruhe Germany

Monitoring the world around us since Real Time Dust Monitors

Results and Lessons Learned from Using Low-Cost PM Sensors to Detect Ambient PM 2.5 and PM 10

Variable Speed Drives: Reducing energy costs in dairy parlours

Strain Gauge Technology

Thirtieth Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

Thirty-Sixth Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

DEVELOPMENT OF A MICRO MONITORING STATION FOR HOT SPOT NARROW STREET MEASUREMENTS

Date June 2, 2006 Page 1 of 5. Approved By

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

AerosolInstruments. Micro Technologies, Big Ideas. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300

REAL-TIME DUST MONITOR TEOM 1405-F

Thirty-Fourth Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

8 stream capability with dual mode (H 2 S & total Sulphur)

Indoor Air Pollution Monitoring

Transcription:

BAM-1020 Beta Attenuation Mass Monitor PM 2.5 FEM Configuration The New Evolution of BAM Technology Dennis Hart Met One Instruments, Inc. Rev C July 2008 4/23/2009 1

Overview The Big Picture The success of any BAM-1020 monitoring program is directly proportional to how well the site operators and program administrators understand how and why the unit works. Basic knowledge of how and why (not just how) the various setups, checks, and calibrations are performed always leads to better end results. Met One is making a strong effort to provide this information through improved documentation, field training, and expanded technical service. 4/23/2009 2

Overview Topics of Discussion Brief History of the BAM-1020 PM2.5 Configuration What is the FEM PM2.5 Configuration? Basic Theory of Operation Three Basic Systems: Flow, Measurement, and Data Critical Checks and Maintenance Measurement Challenges 4/23/2009 3

Brief History of the PM2.5 FEM Configuration 1930s - Beta attenuation measurement technology first developed for industrial processes and paper manufacturing. 1970s - Beta attenuation technology adapted to measure airborne particulate levels. 1990s The Met One BAM-1020 was developed with reduced size and advanced microprocessor control. EPA PM10 FEM approval obtained in 1998. 2002 The Met One E-BAM E was developed as a sister product for rapid deployment and emergency response with variable data intervals. 2006 The FEM PM2.5 BAM-1020 Configuration was developed and FEM testing began. 2007 PM2.5 FEM Candidate Configuration released for sale. March, 2008 - EPA PM2.5 FEM designation obtained for the BAM-1020. 4/23/2009 4

What is the PM2.5 FEM Configuration? The classic BAM-1020 had appropriate accuracy and sensitivity for measuring PM10 levels, and was also often used for PM2.5 monitoring with the addition of a standard SCC cyclone or WINS impactor,, even without equivalency. Field results from these early PM2.5 systems showed that the BAM needed slight detection limit and Y-intercept Y (offset) improvements for accurate measurements below about 15 micrograms. The slopes were typically quite adequate. PM2.5 levels by nature are much more difficult to measure due to low concentrations and greater volatile content. Small measurement errors may cause large proportional errors. 4/23/2009 5

What is the PM2.5 FEM configuration? The transport assembly was redesigned for filter tape positioning accuracy of about 1/1000 of an inch. The beta source gap geometry was reduced 25%, resulting in higher signal-to to-noise levels and reduced air density effects. The beta count time was increased from 4 to 8 minutes, improving the statistical noise stability by about 40%. Known as the 2X effect. The firmware was extensively revised to provide flow statistics, new settings, and improved field calibrations. The field zero background test was implemented to fine-tune the slope offset characteristics in the field. The BX-596 Temp/Baro combination sensor was designed. 4/23/2009 6

What is the PM2.5 FEM configuration? The combined effect of these improvements resulted in the typical detection limit (2σ) ) of the unit improving from about 6ug to about 3ug for hourly measurements, and below 1ug for 24 hour averages. Met One began PM2.5 FEM testing immediately upon release of the final U.S. EPA specifications for candidate monitors. The units had to meet stringent requirements for both FRM correlation and inter-unit comparison during both winter and summer seasons at multiple sites around the country. 4/23/2009 7

Factory Calibration Example 4/23/2009 8

Data Example 1 PM10 and PM2.5 Levels 4/23/2009 9

Data Example 2 PM10 and PM2.5 Levels 4/23/2009 10

Data Example 3 PM2.5 Slope / Offset 4/23/2009 11

Data Example 4 PM10 Slope / Offset 4/23/2009 12

Typical older unimproved unit comparison to FRM for PM2.5, showing Y-intercept Y offset 4/23/2009 13

What is the PM2.5 FEM configuration? Met One filed the official FEM PM2.5 application with the EPA in late summer 2007. EPA review of the application took several months. The BAM-1020 was the first instrument to successfully complete PM2.5 FEM candidate testing, and is the first (and currently only) instrument to obtain EPA FEM status for PM2.5. All BAM-1020 units built after March 2007 are FEM compatible when equipped with the appropriate settings and accessories. The new BAM-1020 configuration maintains it s longstanding FEM status for PM10 monitoring. 4/23/2009 14

What is the PM2.5 FEM configuration? The unit must use the EPA-mandated VSCC-A cyclone from BGI Inc., and the standard EPA PM10 inlet. The unit must be equipped with revision 3.2.4 or later firmware, and must be operated per the revision F or later manual. The unit must use the BX-596 AT/BP sensor. The unit must be operated with 8 minute counts and 42 minute samples on standard glass fiber filter tape. The unit must use the inlet Smart Heater, with an RH control set- point of 35%. The unit must be set for Actual volumetric flow control. The BKGD value must be audited in the field with the BX-302 zero filter kit upon deployment. 4/23/2009 15

What is the PM2.5 FEM configuration? Many older units can be upgraded to the latest hardware and the FEM PM2.5 version. The upgrade involves a complete rebuild and calibration of the unit at the factory. Units built before March, 2007 will need mechanical upgrades to the hardware before they can be configured for PM2.5. All BAM-1020 units built after this have the latest hardware parts. Most units built after 2003 (serial prefix C) are upgradeable. Met One does not recommend upgrades for older units. Contact the Sales Dept for the current price of upgrades. Met One now offers substantial discounts for trade-ins of old units. This also results in much faster turn around time than an upgrade of an old unit. 4/23/2009 16

Theory of Operation At the beginning of the hour, a small Carbon 14 element emits a constant source of beta rays through a clean spot of filter tape to determine a zero reading. The unit advances this spot to the sample nozzle where air containing particulate is sampled and deposited on the filter tape. At the end of the hour, the dirty spot is placed back at the source where is it re- measured with beta rays. The difference between the two measurements is proportional to the mass concentration. 4/23/2009 17

Mass Calculation I = I e 0 μ x 1 I x = ln μ I0 Ax C = V 4/23/2009 18

Mass Calculation DEFINITIONS: I 0 beta measurement across clean filter I beta ray measurement across dirty filter μ calibration coefficient x mass density on filter tape (mg/cm 2 ) A dust spot deposition area on filter tape (cm 2 ) V sampled volume (m 3 ) C particulate matter concentration (mg/m 3 ) 4/23/2009 19

General Beta Gauge Advantages Seasonal and geographical correction factors are not needed. It is not necessary to ever calibrate the beta measurement system in the field. BAMs are calibrated to provide excellent agreement with FRM gravimetric standards when properly maintained and operated. Beta technology is virtually unaffected by the chemical composition of the sampled particulate. 4/23/2009 20

Beta Gauge Safety The BAM-1020 contains a small amount of 14 C (Carbon 14), a naturally occurring radioactive isotope of carbon, in the form of barium carbonate. Activity level of the 60 µci 14 C source is similar to several commercial smoke detectors, and is licensed with the NRC under the same provisions. Sources with activity under 100 µci require no special government licensing to own. Met One Instruments has an Exempt Distribution License from the US-NRC to distribute the beta sources. 4/23/2009 21

Beta Gauge Safety Users are not required to take any specific precautions when handling the BAM-1020 unit. USA customers do not require any licenses to own a Met One beta gauge. The end user will never need to remove, replace, or handle the beta source. The unit may be returned to the factory for disposal at the end if its service life, although this is not required. 4/23/2009 22

BAM-1020 Tape Transport 4/23/2009 23

Simplicity Flow System The BAM-1020 airflow system consists of a few simple components: Inlet/Nozzle Filter Temp/RH/BP sensors Debris filter Honeywell mass flow sensor Flow controller Pump (external) 4/23/2009 24

Simplicity Measurement System The BAM-1020 measurement system consists of a few components: Carbon 14 Beta source Filter tape control system Photomultiplier detector Preamp circuitry Automatic hourly span check 4/23/2009 25

Simplicity Data System The BAM-1020 data system consists of the CPU, data reports, user interface, error handling system, and telemetry. All units are equipped with a six channel external data logger for external sensors. The BAM-1020 may also function as a sensor in a larger data collection system using an external datalogger. 4/23/2009 26

Critical Checks Leak Check, Flow Check, Nozzle Cleaning! The flow system should be calibrated or verified on a regular basis. Flow errors affect the concentration. A leak check is performed with every flow check. Leaks cause measurement errors, and the unit cannot automatically detect a leak. The nozzle and support vane must be cleaned to prevent leaks and tape damage. The nozzle and vane may need to be cleaned more frequently in humid environments. 4/23/2009 27

Critical Checks The nozzle seal against the filter tape is important for proper airflow regulation. The nozzle and support vane need to be cleaned at least as often as the filter tape is changed. 4/23/2009 28

BAM-1020 Span Check The BAM-1020 makes an automatic span check each hour by measuring a Mylar calibration foil with a constant and known mass density. No calibration changes are made based on the span check however. If the span check falls outside of an acceptance band, an error is generated. The span check may be manually audited. 4/23/2009 29

Measurement Challenges Environmental conditions can play a role in the accuracy of beta attenuation measurements. The main factors are: Enclosure internal air temperature stability. Relative humidity and sample moisture. Electromagnetic and radio interference sources. 4/23/2009 30

Measurement Challenges Enclosure Temperature Stability: The BAM-1020 should be in a stable temperature environment, to the extent possible. The exact temperature is not critical as long as it is fairly stable during the hour. Changes in air density between the source and detector may be measured as mass noise. 4/23/2009 31

Measurement Challenges Humidity: The filter tape is semi-hydrophobic, but particulate on the tape is not. Moisture accumulation on the sample spot may be measured as mass noise. BAM-1020 uses smart heater technology to lower the RH of incoming air to about 35%. Mild heat and hourly spot changes limit the effects on VOCs. Humid conditions can increase nozzle fouling. 4/23/2009 32

Electromagnetic Interference Sources of high RF energy may cause noise in the BAM-1020 if in close proximity. Examples: Radio towers or cell antennas in very close proximity. Sources of high EMI fields may cause noise in the system. Examples: Large AC motors, Medical imaging equipment. Static electricity (ESD) may cause measurement errors. Lightning strike on the inlet will damage the unit. Solutions: Proper site selection and grounding. 4/23/2009 33

Conclusion Met One Instruments, Inc. is constantly testing and experimenting to improve the beta gauge product lines and documentation. We welcome suggestions for future improvements. 4/23/2009 34

Supplemental Materials BAM-1020 Manual: Completely reorganized and rewritten for more value to the operator and administrator. Available in electronic format for SOPs. Current Revision G. BAM-1020 data sheet and specifications: Dependable and defensible. www.metone.com BAM users area: Login: metone Password: oregon 4/23/2009 35

Contacts Sales: Science: Engineering: Service: David Gobeli,, Ph.D. Jo Ann Pottberg Peter Pomponi Herbert Schloesser,, Ph.D. Dennis Hart Mike Putnam, Service Mgr. Phone: (541) 471-7111 7111 4/23/2009 36