Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Scope of Accreditation For Retlif Testing Laboratories

Anecto Ltd. Ballybrit Business Park, Galway. Testing Laboratory Registration number: 175T

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CONTECH RESEARCH INC. 67 Mechanic Street Attleboro, MA Mark Gates MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CONTECH RESEARCH INC. 750 Narragansett Park Drive Rumford, RI Thomas Lamoureux

Transport of IGCT. The transportation of IGCT is classified according to IEC set IE22. Power and productivity for a better world

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EUROPEAN ETS TELECOMMUNICATION May 1994 STANDARD

Mark R. Chrusciel. Director of Sales. For a copy of the slides

SUMMARY OF INDEPENDENT ENVIRONMENTAL TESTING

MAR 17 Rev B1

QA Test Report VITA-350. (Product Reliability Test) Charles Chang Manager of QA Department. Knight Hu Test Engineer. Jeff Yang Approval

U7242A USB3.0 Test Fixture

EUROPEAN ETS TELECOMMUNICATION February 1992 STANDARD

AUGUST 14, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC.

SPEAKER SC-COBRA

High Current Thermal Fuse

EUROPEAN ETS TELECOMMUNICATION February 1992 STANDARD

Feb12 Rev D

CHOOSING THE RIGHT RFID TECH FOR MANUFACTURING

20 W Power Resistor, Thick Film Technology, TO-220

Seismic Qualification Test Protocols, Standards and Methodology

Agenda. About Designplan. Robust. Considerations for Robust Products. Applications. Characteristics

STS Directory Accreditation number: STS 0050

A Study of Environmental Test Sequences for Electrical Units Jung Ho Yang, Yong Soo Kim

Agilent 8490G Coaxial Attenuators

Mar11 Rev B

Military Attenuator Module

Product Specification JUL 14 Rev. A1

ETSI EN V2.1.2 ( )

DEPARTMENT OF DEFENSE

ETSI EN V2.2.1 ( )

Long-Range Reader/Writer

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

3820 en / c

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

SMPM Female Cabled Connectors

RF Transformer (Stabilized Matching Device) SMST18 series

Pendulum Impact Testers

MAY 22, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC.

OVERVIEW OF PROCEDURE 2A

20 A / 32 A / 63 A / 125 A / 200 A

Design Qualification Test Report SMS/TMS SMS L-D/TMS L-D

DC-DC Converters MI-J00

LSA 47.2 Low Voltage Alternators - 4 pole

Automotive Electronic Material Challenges. Anitha Sinkfield, Delphi

INTERFACE STANDARD ENVIRONMENTAL CONDITIONS FOR THE HEAVY BRIGADE COMBAT TEAM TRACKED VEHICLE SYSTEMS

LSA Rating Table Low Voltage Alternators - 4 pole

ProFoss for in-line process analysis of dairy powder

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

ISO INTERNATIONAL STANDARD. Optics and photonics Environmental requirements Part 6: Test requirements for medical optical instruments

Expanded Beam Optical Termini

Photo Resistive Flame Detectors

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

China Nuclear Power EQ Testing

RBK-ILS-125 SCOPE. This Quality Assurance Specification establishes the quality standard for RBK-ILS-125.

Bemis Laboratory Services

SOT-23 Reliability November 23, 1998

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

HAZADOUS LOCATION LED FLOOD LIGHT

LSA 42.3 Low Voltage Alternators - 4 pole

(1) SHAPES AND DIMENSIONS (2) ELECTRICAL SPECIFICATIONS SEE TABLE 1 (3) CHARACTERISTICS. Equivalent circuit. No Polarity

WLC60 Heavy Duty LED Light

Mar11 Rev D

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

High Pulse, Fusible, Non-Inductive, Flameproof, Metal Film Resistor

METSO MULTI-FLO MINING SCREENS METSO MF MINING SCREENS TECHNICAL SPECIFICATION

Mar11 Rev B

OVERVIEW OF PROCEDURE 2B

Series description Wilo-Drain STS 40

Bemis Laboratory Services Your Reliable Test Partner

Thermal Shock Test Chambers TS Series

ISA-WELD // Precision resistors. BRS // Size Features

SECTION 2: PROBES. Page 2-1

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Global Metal Solutions Oil & Gas Aerospace Naval & Marine Power Generation Motor Sport Metalworking Medical

Impact Tester. Ball Drop Easy operating falling dart instrument according ASTM D 1709 and ISO Instruments for mechanical testing.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Mar11 Rev C

DONGWOO E&C Tube & Pipe Division

DATA SHEET PART NO. : C-2570SR-A G/W REV : A / 0

General Purpose Chip Resistors MCMR Series

Reference Only. Chip Ferrite Bead BLM31 SZ1 Murata Standard Reference Specification [AEC-Q200]

Testing and Optimization

RUAG Space Testing Services

GOLAN INDUSTRIES Unclassified

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Sulfur tolerant chip resistors

PSE Technology Corporation

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

CERTIFICATE OF ACCREDITATION

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

2 of 13 pages Directory 1. Outline Drawing 3/13 2. Features 3/13 3. Typical Applications 3/13 4. Specifications 3/13 5. Capacitor series code informat

Transcription:

Product Assessment & Reliability Centre Ltd Unit 4 Alverdiscott Industrial Estate Bideford Devon EX39 4LQ Contact: Mr Richard Tabor Tel: +44 (0)1237 421255 E-Mail: info@parctest.co.uk Website: www.parctest.co.uk Testing performed at the above address only DETAIL OF ACCREDITATION General non-explosive stores and equipment including: Aerospace Structures, Materials and Equipment (non-explosive items) CLIMATIC Agricultural Equipment High Temperature - Low Humidity BS EN 60068-2-2:2007 Computers and Peripherals - Steady State and Cyclic Test B Domestic Appliances BS EN 60068-2-2:1993 Electrical/Electronic Components, Max temp: +60 C Tests Ba, Bb Connectors and Products Max chamber size: IEC 68-2-2:1974 Electro-Mechanical Devices 2 m x 1.6 m x 2.2 m Supp A:1976, Amd 1:1993 Loaded Containers DEF 00-35 (Part 3)/3 Marine Equipment Max temp: +100 C Test CL1 Mining Equipment Max chamber size: DEF STAN 00-35: Part 3:iss 4 Missile Sub-Assemblies and Components 1 m x 1.2 m x 1.9 m Test CL2 MIL-STD-810G, Method 501.5 MIL-STD-810G:CN1 Method 501.6 MIL-STD-810F, Method 501.4 Motor Vehicle Accessories and MIL-STD-810E, Method 501.3 Components Max temp: +150 C MIL-STD-810D, Method 501.2 Office Equipment Max chamber size: RTCA DO-160D, Sections 4 & 5 Radar Equipment 2 m x 2 m x 2 m RTCA DO-160E, Sections 4 & 5 Radio and Television Equipment RTCA DO-160F, Sections 4 & 5 Case Manager: NM1 Page 1 of 11

Safety Appliances and Equipment non-explosive items) (cont d) Max temp: +170 C Max chamber size: EURO CAE ED-14G, sections 4 & 5 TR2130B:May 1993: Satellites and Sub-Assemblies 1.0 m x 1.0 m x 1.0 m Section 3.1 TR2130C, Feb 2002, Section 3.2TR2130E:Aug 2014 Section 6 Security Devices and Alarms DEF STAN 08-123 (NES 1004) Telecommunications Equipment iss 1:April 2000, Iss 2:Nov 2012 Data Sheet 9 Weapons and Sub-Assemblies Max temp: +200 C Rail and Rolling stock equipment Max chamber size: BS EN 60068-2-14:2009 Test Nb And components 0.5 m x 0.6 m x 0.8 m BS EN 60945:2002, Test 8.2 Sub-sea equipment & components BS 7987:2001 Medical devices and components ISO 16750-4:2010 EN ISO 13628-6:2006 Case Manager: NM1 Page 2 of 11

non-explosive items) (cont d) CLIMATIC (cont d) Low Temperature BS 2011:Part 2.1A:1990 - Steady State and Cyclic MIL-STD-810G, Method 502.5 Min temp: -70 C MIL-STD-810G:CN1 Method 502.6 Max chamber size: MIL-STD-810F, Method 502.4 2.0 m x 2.0 m x 2.0 m MIL-STD-810E, Method 502.3 Min temp: -40 C MIL-STD-810D, Method 502.2 Max chamber size: RTCA DO-160D, Sections 4 & 5 1 m x 1.2 m x 1.9 m RTCA DO-160E, Sections 4 & 5 Min temp: -5 C RTCA DO-160F, Sections 4 & 5 Max chamber size: EURO CAE ED-14G, sections 4 & 5 2 m x 1.6 m x 2.2 m DEF STAN 00-35: Part 3: iss 4 Min temp: -65 C Test CL5 Max chamber size: TR2130C :Feb 2002, Section 3.3 2.0 m x 2.0 m x 2.0 m TR2130E:Aug 2014 Section 6 TR2130 iss B: May 1993: Section 3.2 DEF STAN 08-123 (NES 1004) Iss 1: April 2000, Iss 2:Nov 2012 Data Sheet 9 BS EN 60068-2-14:2000 Test Nb BS EN 60068-2-14 :2009 Test Nb BS EN 60068-2-1:2007 IEC 68-2-1:1990 DEF 00-35 (Part 3)/3 Tests CL4, CL5 BS EN 60945 :2002, Test 8.4 BS 7987:2001 ISO 16750-4:2010 EN ISO 13628-6:2006 Thermal Shock - Automated Transfer Max temp: +200 C BS EN 60068-2-14:2009 Test Na Min temp: -70 C IEC 68-2-14:1999 Test Na Max size: 0.46 m x 0.35 m x 0.6 m MIL-STD-810G, Method 503.5 MIL-STD-810F, Method 503.4 MIL-STD-810E, Method 503.3 MIL-STD-810D, Method 503.2 TR2130 iss B: May 1993: Section 3.3 TR2130C, Feb 2002, Section 3.4 ISO 16750-4 :2010 Case Manager: NM1 Page 3 of 11

non-explosive items) (cont d) CLIMATIC (cont d) Thermal Cycling RTCA DO-160 D, Section 5 RTCA DO-160 E, Section 5 RTCA DO-160 F, Section 5 EURO CAE ED-14G, section 5 BS EN 60068-2-14:2009 Test Nb IEC 68-2-14:1999 Test Nb ISO 16750-4 :2010 EN ISO 13628-6:2006 BS 2011:Ca:1977 High/Low Temperature & Humidity IEC 68-2-3:1969 - Steady State and Cyclic IEC 68-2-56:1988 Temp range: -70 C to +180 C BS EN 60068-2-78:Cab:2002,2013 Humidity range: 15-98% RH BS EN 60068-2-30:1999 Max chamber size: BS EN 60068-2-30:2005 0.58 m x 0.765 m x 0.780 m IEC 68-2-30:1980 (Amd 1, 1985) BS EN 60068-2-38:2009 Temp range: -70 C to +170 C IEC 68-2-38:1974 Humidity range: 15-95% RH MIL-STD-810G, Method 507.5 Max chamber size: MIL-STD-810G:CN1 Method 507.6 1.0 m x 1.0 m x 1.0 m MIL-STD-810F, Method 507.4 MIL-STD-810E, Method 507.3 Temp range: -65 C to +150 C MIL-STD-810D, Method 507.2 Humidity range: 15-98% RH DEF 00-35 (Part 3)/3 Max chamber size: Test CL7 2.0m x 2.0m x 2.0m RTCA DO-160D, Section 6 RTCA DO-160E, Section 6 RTCA DO-160F, Section 6 EURO CAE ED-14G, section 6 TR2130B: May 1993:Section 3.4 TR2130C : Feb 2002, Section 3.5 TR2130E:Aug 2014 Section 6 DEF STAN 08-123 (NES 1004) iss 1:April 2000:, Iss 2:Nov 2012Data Sheet 9 DEF STAN 00-35: Part 3:iss 4 Test CL6 BS EN 60945:2002, Test 8.3 BS 7987:2001 ISO 16750-4:2010 Case Manager: NM1 Page 4 of 11

non-explosive items) (cont d) CLIMATIC (cont d) Low Air Pressure (altitude) Max chamber size: BS EN 60068-2-13:M:1999 0.915 m x 0.915 m x 0.915 m RTCA/DO-160D, Section 4 Max altitude: 65 000 ft RTCA/DO-160E, Section 4 RTCA/DO-160F, Section 4 EURO CAE ED-14G, section 4 DEF STAN 00-35:Iss 4: Test CL21, Procs A, B & C MIL-STD 810F, Method 500.4 MIL-STD 810G, Method 500.5 MIL-STD-810G:CN1 Method 500.6 Dry Heat & Low Air Pressure (altitude) Low Temperature & Low Air Pressure (altitude) BS EN 60068-2-41:Z/BM:2000 RTCA DO-160D, Section 4 RTCA DO-160E, Section 4 RTCA DO-160F, Section 4 EURO CAE ED-14G, section 4 DEF STAN 00-35:Iss 4: Test CL11 Proc A RTCA DO-160D, Section 4 RTCA DO-160E, Section 4 RTCA DO-160F, Section 4 EURO CAE ED-14G, section 4 MIL-STD 810F, Method 500.4 MIL-STD 810G, Method 500.5 MIL-STD-810G:CN1 Method 500.6 BS EN 60068-2-40:2000:Z/AM DEF STAN 00-35:Iss 4:Test CL12 Ingress Protection Tests (Probes) IP1X Protected against solid objects greater than 50 mm dia IP2X Protected against solid objects greater than 12.5 mm dia IP3X Protected against solid objects greater than 2.5 mm dia IP4X Protected against solid objects greater than 1.0 mm dia BS EN 60529:1992+A2:2013 BS EN 60529:1992 (2000) EN 60529:1991 TR2130E:Aug 2014 Section 6 Case Manager: NM1 Page 5 of 11

CLIMATIC (cont d) Ingress Protection Tests (Dust) IP5X Dust Protected BS EN 60529:1992+A2:2013 IP6X Dust Tight BS EN 60529:1992 (2000) EN 60529:1991 EN 60598-1:2015 EN 60598-1:2008 TR2130E:Aug 2014 Section 6 ISO 20653:2006 BS 7987:2001 Ingress Protection Tests (Water) IPX2 Protected against dripping BS EN 60529:1992+A2:2013 water when tilted up to 15 BS EN 60529:1992 (2000) EN 60529:1991 IPX3 Protected against spraying EN 60598-1:2015 water EN 60598-1:2008 DIN 40050 Part 9:May 1993 IPX4 Protection against TR 2130B:1993 splashing water TR 2130C:2002 IPX5 Protected against water jets TR2130E:Aug 2014 Section 6 IPX6 Protected against powerful BS 7987:2001 water jets DEF STAN 00-35: Part 3,Iss 4, Test IPX7 Protected against the effects CL29, Procedures A and B of immersion ISO 20653:2006 IPX8 Protected against the effects BS EN 60068-2-18:2001 of submersion IPX9 and IPX9K Protection against Effects of high pressure and water pressure ISO 20653:2013 Section 6 BS EN 60529:1992+A2:2013 Rain & Spray Chamber size: BS EN 60945:2002, Test 8.8 0.94 m x 0.86 m x 0.9 m TR2130 iss B:May 1993: section 3.8 TR2130E:Aug 2014 Section 6 Driving Rain Condensing Water Drip Proof Test Spray Proof Test DEF STAN 00-35:Iss 4, Test CL27 RTCA DO-160G/EUROCAE ED14G Section 10.3.1 10.3.3 Case Manager: NM1 Page 6 of 11

CLIMATIC (cont d) Salt Spray MIL-STD 810D, Method 509.2 Chamber size: MIL-STD 810E, Method 509.3 W 1650 mm MIL-STD 810F, Method 509.4 D 540 mm MIL-STD 810G, Method 509.5 H 740 mm MIL-STD-810G:CN1 Method 509.6EN 60068-2-11:1999 Ka IEC 60068-2-11:1981 Ka BS EN 60068-2-52:1996 Kb IEC 60068-2-52:1996 Kb ASTM-B117-11 ASTM-B117-07a 12/02/2008 ASTM-B117-02 RTCA DO-160D, Section 14 RTCA DO-160E, Section 14 RTCA DO-160F, Section 14 EURO CAE ED-14G, section 14 DEF STAN 00-35:Part 3:iss 4 Test CN2 BS EN 60945:2002, Test 8.12 ISO 16750-4:2006 TR2130E:Aug 2014 Section 6 DYNAMIC Single Parameters VIBRATION - Sinusoidal DEF 00-35 (Part 3)/3:Test M1:1990 (ambient temperature) DEF STAN 00-35: Part 3:iss 4 Freq range: 3 to 2400 Hz Test M1 Max load: 1500 kg MIL-STD 810G, Method 514.6 Max pk-pk displacement: 50 mm MIL-STD-810G:CN1 Method 514.7 Max item height: 3.0 m MIL-STD 810F:Method 514:1998 MIL-STD 810E:Method 514:1989 MIL-STD 810D:Method 514:1991 BS 2011:Part 2.1:Fc:1973 (1983) BS EN 60068-2-6:2008 RTCA DO-160D, Section 8 RTCA DO-160E, Section 8 RTCA DO-160F, Section 8 EURO CAE ED-14G, section 8 DEF STAN 08-123 (NES 1004) iss 1:April 2000, Iss 2:Nov 2012 : Data Sheet 25 TR2130 iss B:May 1993: Section 3.12 TR2130E:Aug 2014 Section 5 Case Manager: NM1 Page 7 of 11

DYNAMIC Single Parameters (cont d) VIBRATION Random BS EN 60945:2002, Test 8.7 Sine on Random MIL-STD 167-1A:2005, Test 5.1, Random on Random Type 1 (ambient temperature) BS ISO 16750-3:2007 BS ISO 16750-3:2012 Freq range: 3 to 2400 Hz EN ISO 13628-6:2006 Max load: 1500 kg BS EN 60068-2-64:1995 Max pk-pk displacement: 50 mm BS EN 60068-2-64:2008 Max item height: 3.0 m BS EN 61373 :2010 DEF 00-35 (Part 3)/3:Test M1:1990 DEF STAN 00-35: Part 3:iss 4 Test M1 MIL-STD 810G, Method 514.6 MIL-STD-810G:CN1 Method 514.7 MIL-STD 810 F:Method 514:1998 MIL-STD 810 E:Method 514:1989 MIL-STD 810 D:Method 514:1991 BS 2011:Part 2.1:Fd:1973 (1983) BS 2011:Part 2.1:Fda:1973 (1983) BS 2011:Part 2.1:Fdb:1973 (1983) BS 2011:Part 2.1:Fdc:1973 (1983) RTCA DO-160D, Section 8 RTCA DO-160E, Section 8 RTCA DO-160F, Section 8 EURO CAE ED-14G, section 8 DEF STAN 08-123 (NES 1004) iss 1: April 2000:, Iss 2:Nov 2012: Data Sheet 25 TR2130 iss B:May 1993: Sections 3.11 & 3.14 TR2130C, Feb 2002, Section 5.2-5.4 TR2130E:Aug 2014 Section 5 BS EN 50155 :2007, Section 12.2.11 BS EN 50125-3:2003, Section 4.13.1 BS EN 61373:1999, Section 8 BS 7987:2001 Case Manager: NM1 Page 8 of 11

DYNAMIC (cont d) Single Parameters (cont d) MIL-STD 810G, Method 514.6 MIL-STD-810G:CN1 Method 514.7 MIL-STD 810F:2001 (High/Low Temperature) BS EN 60068-2-50 BS EN 60068-2-51 Freq range: 3 to 2000 Hz BS EN 60068-2-53 Max Load: BS 2011:Part 2.2, 2/AFC - Vertical: 600 kg and Z/BFC - Horizontal: 600 kg BS EN 60068-2-80 2005, Test Fi Max pk-pk displacement: 50 mm Max temperature: +170 C Min temperature: -70 C Max chamber size: 0.85 m x 0.85 m x 0.85 m BUMP DEF 00-35 (Part 3)/3: (ambient temperature) Test M12:1986 DEF STAN 00-35: Part 3:iss 4 Max item mass: 1500 kg Max item height: 3.0 m Test M12 BS 2011:Part 2.1:Eb:1987 BS EN 60068-2-29:1993 BS EN 60068-2-27:2009 Max severity: 100 g TR2130 iss B:May 1993: Pulse duration: 1-30 ms Section 3.10 TR2130C, Feb 2002, Section 5.7-5.9 TR2130E:Aug 2014 Section 5 BS ISO 16750-3:2007 BS ISO 16750-3:2012 SHOCK - All classical shock pulse DEF 00-35 (Part 3)/3:Test M3:1990 shapes, inc half sine, rectangular, DEF STAN 00-35: Part 3:iss 4 trapezoidal and sawtooth, plus Tests M3 & M6 MIL-STD 810G, Method 516.6 synthesized shock and bump MIL-STD-810G:CN1 Method 514.7 MIL-STD 810F:Method 516:1998 signatures duplicating measured MIL-STD 810E:Method 516:1989 conditions MIL-STD 810D:Method 516:1991 (ambient temperature) BS 2011:Part 2.1:Ea:1988 BS EN 60068-2-27:2009 Max item mass: 1500 kg BS EN 60068-2-27:1993 BS EN 61373:2010 Max severity: 100 g DEF 00-35 (Part 3)/3:Test M6:1999 Max item height: 3.0 m BS EN 60068-2-81:2003 Case Manager: NM1 Page 9 of 11

DYNAMIC (cont d) DEF STAN 08-123 (NES 1004 Single Parameters (cont d) iss 1:April 2000: Iss 2:Nov 2012 : Data Sheet 28 Max temperature: +170 C TR2130E:Aug 2014 Section 5 RTCA/DO-160D, Section 7 Min temperature: -70 C RTCA/DO-160E, Section 7 using in-house Procedure RTCA/DO-160F, Section 7 EURO CAE ED-14G, section 7 PARC Operating Procedure OP20, Rev 6, 01/09/2015 BS ISO 16750-3:2007 BS ISO 16750-3:2012 EN ISO 13628-6:2006 IMPACT 2 Joule Spring Hammer BS EN 60068-2-75:2014 Tests Ehb 5, 10, 20 joule and Ehc IK07-10 BS EN 62262:2002 Striking Elements TR2130E:Aug 2014 Section 5 DROP & TOPPLE BS EN 60068-2-31: Ec:2008 DEF STAN 00-35:Part 3:iss 4 Test M4 MIL-STD 810D:Method 516.3:1986 MIL-STD 810E:Method 516.4:1990 MIL-STD 810F:Method 516.5:2000 MIL-STD 810G, Method 516.6 MIL-STD-810G:CN1 Method 516.7 TR2130E:Aug 2014 Section 5 FREE FALL BS EN 60068-2-32:Ed:1993 Max drop ht: 2.5 m BS EN 60068-2-31:Ec:2008 Max item mass: 250 kg MIL-STD 810D:Method 516.3:1986 MIL-STD 810E:Method 516.4:1990 MIL-STD 810F:Method 516.5:2000 MIL-STD 810G, Method 516.6 MIL-STD-810G:CN1 Method 516.7 BS ISO 16750-3:2007 BS ISO 16750-3:2012 Case Manager: NM1 Page 10 of 11

Highly Accelerated Life Testing (HALT) (Using Screening Systems Incorporated QRS-410T CE HALT System) Analysed frequency range: 10 Hz to 2 khz Max item mass: 40 kg Max item size: 610 mm x 520 mm x 350 mm Temperature range: -60 C to +150 C Max rate of change: 60 C/min Documented In House Procedure: OP30:Rev 7: Oct 2015 (including all previously approved versions) END Case Manager: NM1 Page 11 of 11