SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

Similar documents
7.1 Transmission of Prestress (Part I)

Special Reinforced Concrete Structural Walls

Seismic Detailing of RC Structures (IS: )

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Structural Behaviors of Deep RC Beams under Combined Axial and Bending Force

In-plane testing of precast concrete wall panels with grouted sleeve

Design for Shear for Prestressed Concrete Beam

Moment curvature analysis of concrete flexural members confined with CFRP grids

Pile to Slab Bridge Connections

ST7008 PRESTRESSED CONCRETE

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

> 0. 1 f, they are treated as beam-columns.

STRENGTHENING WITH WING WALLS FOR SEISMICALLY SUBSTANDARD R/C BEAM-COLUMN JOINTS

Chapter Five Torsion. Reinforced Concrete Structures 2 (CEng-3122)

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

Shear Behavior of R/C Beams with Web Openings Reinforced by Prestress Force

Effect of beam dimensions on structural performance of wide beam-column joints

Strength Design of Reinforced Concrete Structures

Experimental investigation on the shear capacity of RC dapped end beams and design recommendations

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

COMPERATIVE STUDIES OF REINFORCEMENT CONCRETE BEAM DESIGN USING BS 8110 AND ACI 318 AHMAD ADLI BIN JAMALUDIN AA07192

SHEAR BEHAVIOR OF DOUBLY REINFORCED CONCRETE BEAMS WITH AND WITHOUT STEEL FIBERS AFFECTED BY DISTRIBUTED CRACKS

5.4 Analysis for Torsion

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Design Example 2 Reinforced Concrete Wall with Coupling Beams

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Modelling of RC moment resisting frames with precast-prestressed flooring system

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Shear-friction truss model for reinforced concrete beams

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

3D analysis of solid reinforced concrete beams subjected to combined load of bending, torsion and shear

IMPROVEMENT OF THE DEFORMATION CAPACITY BY THE USE OF FIBERS

ANALYTICAL STUDY OF ECCENTRIC BEAM COLOUMN JOINT

CFT Column-to-Cap Beam Connections for. Accelerated Bridge Construction in Seismic Regions. Lisa Marie Berg. Master of Science in Civil Engineering

Seismic Performance of GFRP-RC Exterior Beam-Column Joints with Lateral Beams

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

Performance of Pretensioning Prestressed Concrete Beams with Ruptured Strands Flexurally Strengthened by CFRP Sheets

1. INTRODUCTION. Fig.1 Dimension of test specimen

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

ULTIMATE LOAD-CARRYING CAPACITY OF SELF-ANCHORED CONCRETE SUSPENSION BRIDGE

Chapter 2: Strain. Chapter 3: Torsion. Chapter 4: Shear and Moment Diagram

DUCTILITY REQUIREMENTS FOR BUILDINGS

SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE

Behaviour of FRP wrapped circular reinforced concrete columns

SHEAR STRENGTH OF BEAMS REINFORCED WITH SYNTHETIC MACRO-FIBERS AND STIRRUPS

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

Chapter. Masonry Design

Behavior and failure mode of reinforced concrete members damaged by pre-cracking

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Study of Shear Behavior of RC Beams: Non Linear Analysis

3. Bond, Anchorage and Shear This chapter will discuss the following topics:

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Development of a rational design methodology for precast concrete slender spandrel beams: Part 2, analysis and design guidelines

CHAPTER 11: PRESTRESSED CONCRETE

NONLINEAR FINITE ELEMENT ANALYSIS OF NON- SEISMICALLY DETAILED INTERIOR RC BEAM-COLUMN CONNECTION UNDER REVERSED CYCLIC LOAD

Design of Doubly Reinforced Rectangular Beam Limit State Method

APPENDIX B ABC STRUCTURES DESIGN GUIDE

DESIGN OF WALLS FOR SHEAR

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

USE OF HEADED BARS AS SHEAR REINFORCEMENT

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Compression Behavior, Strength, and Ductility of Confined Concrete after Inelastic Tensile Cyclic Loading

PRELOADING EFFECT ON LOAD CAPACITY AND DUCTILITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED CFRP STRIPS

Al-Ta'an : Nonlinear Finite Element Analysis of Fibrous Reinforced Concrete Beam- Received 14 Sep Accepted 19 Feb.

WATER RESEARCH COMMISSION. KSA 1: Water Resource Management. Thrust 2: Management of Natural and Human-induced Impacts on Water Resources

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

Hyperstatic (Secondary) Actions In Prestressing and Their Computation

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

Strength Study on Castellated Beam

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Sabah Shawkat Cabinet of Structural Engineering 2017

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

Section A A: Slab & Beam Elevation

Finite Element Analysis of Reinforced Concrete Corbels

Ensuring sufficient robustness to resist

EXPERIMENTAL STUDY ON REINFORCED CONCRETE COLUMN STRENGTHENED WITH FERROCEMENT JACKET

Anchorage Failure and Shear Failure of RC Exterior Beam-Column Joint

Council on Tall Buildings

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

New ICC/ACI Design Concept for Post-Installed Reinforcement Bars Kelly Chua, B.Eng (Civil and Structural)

KSK COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING CE 2505-DESIGN OF RC ELEMENTS QUESTION BANK

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

Pacific Earthquake Engineering Research Center

GFRP retrofitted RC frames with columns subjected to high axial stresses

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to published version (if available): /j.engstruct

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

Shear Assessment and Strengthening of Contiguous-Beam Concrete Bridges Using FRP Bars

Transcription:

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT Koji MATSUMOTO (Tokyo Institute of Technology) Moe YONEHANA (Kajima Corporation) Junichiro NIWA (Tokyo Institute of Technology) Linear reinforced concrete (RC) members such as piers and piles are often designed with a circular cross section. The shear span to effective depth ratio (a/d) of such members is sometimes less than 2.0 (short beams) or 1.0 (deep beams). Although the shear resistance mechanism of RC deep beams is different from that of slender beams, the applicability of existing design methods to RC deep beams with circular cross section has not been discussed. Besides, when pile members are subjected to seismic loads, an anti-symmetric moment develops in the range of a/d<2.0 as a result of dynamic earth pressure. However, there have been almost no studies on the shear behavior of RC deep beams with circular cross section subjected to an anti-symmetric moment. In this study, loading tests were carried out on RC deep beams with circular cross section. The experimental parameters were the support arrangement, number of longitudinal reinforcement bars and stirrup ratio. Table 1 lists the experimental cases and Fig. 1 outlines the specimens, respectively.

Table 1: Experimental cases Specimen Support arrangement (series) Number Longitudinal bars Reinforcement Spacing Arrangement ratio* (mm) (%) Stirrups Diameter (mm) Reinforcement ratio (%) S-5-0 5 1/4 in tension side 1.40 - - 0 S-16-0 Simply-supported 2.79 - - 0 S-16-0.48 (Series 1) 16 Entirely 2.79 10 0.48 114 S-16-0.84 2.79 13 0.84 A-10-0 1/4 in tension and 10 Anti-symmetric compression side 1.75 - - 0 A-16-0 moment 2.79 - - 0 A-16-0.48 (Series 2) 16 Entirely 2.79 10 0.48 114 A-16-0.84 2.79 13 0.84 Anchor plate LVDT Unit: mm Nut for inside anchorage Strain gauge Rubber sheet and Teflon sheet (a) Simply-supported arrangement (Series 1) Span (b) Anti-symmetric moment arrangement (Series 2) Unit: mm Fig. 1: Outline of specimens

Experimental values of applied shear force obtained in the tests are corrected by excluding the effect of concrete strength. Figure 2 shows the corrected shear force-mid span deflection relationships (Series 1) and corrected shear force-relative displacement relationships (Series 2) obtained in the experiment. With an increasing number of longitudinal bars and increasing stirrup ratio, the shear capacity increases in both the simply-supported condition and the anti-symmetric moment condition. The shear capacity of a specimen subjected to the anti-symmetric moment is much smaller than that of a simply-supported specimen with the same a/d. Corrected shear force (kn) 600 400 Corrected shear force (kn) 600 400 A-5-0 A-16-0 A-16-0.48 A-16-0.84 200 S-5-0 S-16-0 S-16-0.48 S-16-0.84 200 0 5 10 15 Mid span deflection (mm) 0 5 10 15 Relative displacement (mm) Fig. 2: Corrected shear force-mid span deflection and relative displacement relationships Strain distributions in the region where the compression strut formed were measured using acrylic bars embedded in the specimens, as shown in Fig. 3. Figure 4 shows the stress distributions in the struts as converted from the strain distributions using existing stress-strain models of concrete. In specimens S-16-0.48 and S-16-0.84, which had stirrups, no concave shape is observed as is shown near the loading point in specimens S-5-0 and S-16-0 because the ultimate strain of the concrete is enhanced by the confinement effect of the stirrups. The stress distributions when subjected to an anti-symmetric moment are relatively small compared to the cases under simply-supported condition, indicating that contribution of the compression strut to shear resistance is reduced.

Unit: mm : Strain measurement location 110 110 C L 178 178 4@17 4@17 (a) Simply-supported arrangement (Series 1) (b) Anti-symmetric moment arrangement (Series 2) Fig. 3: Locations of acrylic bars and strain measurement 35.6 39.6 43.5 LC C L C L C L 36.9 53.2 57.3 37.0 46.1 48.3 37.0 50.2 49.0 (a-1) S-5-0 (a-2) S-16-0 (a-3) S-16-0.48 (a-4) S-16-0.84 38.7 42.8 33.4 30.7 19.5 36.7 44.7 17.4 47.1 35.2 33.1 35.4 (b-1) A-10-0 (b-2) A-16-0 (b-3) A-16-0.48 (b-4) A-16-0.84 Fig. 4: Stress distribution in compression struts at 95% of the maximum load (unit: N/mm 2 ) The authors propose the mechanical model shown in Fig. 5 to explain the shear resistance mechanism of RC deep beams when subjected to an anti-symmetric moment. The state of forces is symmetrical with respect to point O and the flow of compression force due to the strut forms such that it encloses the diagonal crack. Since the bending moment is reversed at mid span, a section of concrete in compression forms at either end of the diagonal crack. From the force and moment equilibrium, the following equations can be obtained: 2T 2C cos C T 0 (Horizontal direction) (1) V 2C sin Vs 0 (Vertical direction) (2) Va C z 0 (Moment) (3)

Concrete in compression Centroid, O Diagonal crack Concrete in compression Lines of compression force Moment lever arm, z T C V Centroid, O C T Shear span, a V s : Angle of a compression strut to the member axis V: Applied shear force C and T : Sectional forces at the boundary section between a span and stub (C =T if axial force is zero) C T C: Diagonal compression force of a strut T: Tensile force of longitudinal bars (a) Diagram of compression force and bending moment (b) State of forces in portion marked by the dashed red line in the figure to the left Fig. 5: Shear resistance model of RC deep beams subjected to anti-symmetric moment By solving Eq. (2) for V, Eq. (2) becomes V 2 C sin (4) V s The first and second terms on the right side of Eq. (4) represent the shear resistance contributed by the compression strut and stirrups, respectively. That is, the mechanical model shown in Fig. 5 indicates that the total shear resistance is a summation of the resistance contributed by the compression strut and the stirrups. A-16-0.48 A-16-0.84 292 281 302 333 0 100 200 300 400 Shear resistance or applied shear force (kn) : Shear resistance contributed by a compression strut : V s obtained from the value of strain gauges : 95% of the maximum shear force Fig. 6: Comparison of experimental values with summation of shear resistance force by compression strut and stirrups In Fig. 6, the summed shear resistance contributed by the compression strut and the tensile resistance of the stirrups, V s, are compared with the shear force applied in the experiment. The shear force borne by the compression strut is the vertical component of the force calculated by integrating the stress distributions shown in Fig. 4. As mentioned before, in the case of RC deep beams subjected to

an anti-symmetric moment, the contribution of the compression strut to shear resistance is rather small compared to the total shear force. However, when summed with the tensile resistance of the stirrups, it approximates the experimental values. Consequently, in specimens A-16-0.48 and A-16-0.84, it is supposed that the stirrups contribute a significant shear strengthening effect because of the effect of the shear resistance mechanism illustrated in Fig. 5.