Effect of Layout and Size Optimization Conditions in Architectural Design of Reinforced Concrete Flat Slab Buildings

Similar documents
Two-way slabs. Flat plate with or without drop panels / capitals

Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building

Flat Slabs. d 2. A typical flat slab (without drop and column head)

Types of Foundations

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

Structural Option April 7 th, 2010

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

Technical Report 3. Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R

Sabah Shawkat Cabinet of Structural Engineering 2017

Fundamentals of Post Tensioned Concrete Design for Buildings

POST-TENSIONING APPLICATION AND TECHNOLOGY. Moe Kyaw Aung

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

"Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures

Analysis of Various Steel Bracing Systems using Steel Sections for High Rise Structures

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

U.S. General Services Administration Progressive Collapse Design Guidelines Applied to Concrete Moment-Resisting Frame Buildings

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

Comparative Study of R.C.C and Steel Concrete Composite Structures

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

> 0. 1 f, they are treated as beam-columns.

POST TENSIONED SLABS. Imagineering the possibilities

AISC Steel & Timber Research for High-Rise Residential Buildings

Global Village Rochester Institute of Technology Rochester, New York

IJRET: International Journal of Research in Engineering and Technology eissn: pissn:

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

DUCTILITY REQUIREMENTS FOR BUILDINGS

111 MORGAN ST. Ryan Friis

DESIGN FOR PROGRESSIVE COLLAPSE 1

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Automated Clash Resolution of Steel Rebar in RC Beam Column Joints using BIM and GA

DIRECT DESIGN METHOD DDM

Council on Tall Buildings

EARTHQUAKE DESIGN CONSIDERATIONS OF BUILDINGS. By Ir. Heng Tang Hai

Concrete Framing systems. Design choices. Basic flavors

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

ARCH 614 Note Set 12.1 S2014abn

DESIGN OF GRAVITY-LOAD RESISTING FRAMES FOR SEISMIC DISPLACEMENT DEMANDS

Analysis of Shear Wall Transfer Beam Structure LEI KA HOU

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

Section A A: Slab & Beam Elevation

Design and Estimation of Reinforced Building: A Case Study

Recommendations for additional fire protection of structural elements

ST7008 PRESTRESSED CONCRETE

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Effect of Column Shortening on the Behavior of Tubular Structures

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Continuous Beam Design with Moment Redistribution (ACI )

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Lecture Retaining Wall Week 12

THE STUDY ON BEHAVIOUR OF OUTRIGGERS FOR TALL BUILDINGS SUBJECTED TO LATERAL LOAD

STUDY ON TALL BUILDING STRUCTURE ANALYSIS

Tips For Designing Constructable Concrete Buildings

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

HOLLOW CORE FLOORS SPEED AND STRENGTH

KSK COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING CE 2505-DESIGN OF RC ELEMENTS QUESTION BANK

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

MITRE 3 Building McLean VA

Hyperstatic (Secondary) Actions In Prestressing and Their Computation

ctbuh.org/papers A Study of Flat Plate Slab Column Connections with Shear Plate in Tall Concrete Building using Experimental and Numerical Analysis

Modelling of RC moment resisting frames with precast-prestressed flooring system

Assessment of P-Delta Effect on High Rise Buildings

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

REINFORCING TABLES INSTALLATION MANUAL

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

SEISMIC PERFORMANCE OF FLAT-SLAB SHEAR REINFORCEMENT

Hilton Baltimore Convention Center Hotel Western Podium

A Study on Multi Storied Building Manual Calculation Design in Guntur

Seismic Detailing of RC Structures (IS: )

ANALYSIS OF MULTISTORIED BUILDING WITH AND WITHOUT FLOATING COLUMN USING ETABS

Structural Redesign Gravity System

Distribution of Forces in Lateral Load Resisting Systems

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

LPI 56 Technical Guide

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

The Ultimate Structural Engineering Software Package!

CVEN 483. Structural System Overview

Structural Technical Report #2 By Robert Whitaker

Analysis and Design of 3 Storey Hospital Structure Subjected To Seismic Load Using STAAD PRO

Shear studs in slab-column connections with rectangular column

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Design Calculator for Quick Estimation of Concrete and Reinforcement in the Flat Plate Slab. Abstract

The designer shall also submit additional information required by the University as described and underlined below.

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

DESIGN CALCULATIONS INSTA-FOOTING LOAD BEARING CAPACITIES ON CONCRETE SLAB. January 14, 2017 Rev -

Ultimate and serviceability limit state optimization of cold-formed steel hat-shaped beams

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Applications of sustainable post-tensioned concrete slabs

COMPOSITE BEAM COMPOSED OF STEEL AND PRECAST CONCRETE (MODULARIZED HYBRID SYSTEM). PART III: APPLICATION FOR A 19-STOREY BUILDING

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

Evaluation of Progressive Collapse Resistance of Multi-Storey RC Building by Linear Static Analysis Method

USE OF FLAT SLABS IN MULTI-STOREY COMMERCIAL BUILDING SITUATED IN HIGH SEISMIC ZONE

Pyramid Structural Engineering Applications

Structural System Design

Transcription:

Bulletin of Environment, Pharmacology and Life Sciences Bull. Env. Pharmacol. Life Sci., Vol 2 (5) April 2013: 62-68 2013 Academy for Environment and Life Sciences, India Online ISSN 2277-1808 Original Article Effect of Layout and Size Optimization Conditions in Architectural Design of Reinforced Concrete Flat Slab Buildings 1 Yousef Zandi, 2 Roza Naziri,and 3 R Hamedani 1 Assist. Prof. Dr, Civil Engineering Department,Islamic Azad University, Tabriz Branch, Iran 2 Student. Architectural Engineering Department,Islamic Azad University, Tabriz Branch, Iran 3 Project Manager and Technical Adviser of Hormozgan Cement ABSTRACT Reinforced concrete was chosen as the structural system by the design team for several important reasons on this residential building. The floor to floor heights were minimized with the use of thin, post-tensioned concrete slabs, which allowed the Owner to cost effectively maximize the number of floors in the building. In addition, concrete provided the necessary stiffness for the Outrigger-Braced lateral system while providing the speed of construction necessary to meet the project schedule demands. Cost optimization of RC flat slab buildings using a multi-level optimization procedure was presented. The procedure includes finding the optimum column layout, cross-sectional dimensions and reinforcement of concrete elements. The design optimization of two RC flat slab buildings with different plan and number of storeys was illustrated. Genetic algorithm as a global search technique in conjunction with a local search technique can successfully be used in design optimization of RC structures. Cost of floor slabs is the major structural cost which can result in a significant cost saving in optimization of RC flat slab buildings. It was shown that column layout optimization of flat slab buildings can produce substantial savings in the total structural cost of the building. Keywords: Reinforced concrete, column layout optimization, genetic algorithm, hybrid optimization algorithm, flat slab building. Received 12.03.2013 Accepted 21.04.2013 2013 AELS, INDIA INTRODUCTION In flat slab buildings floors are directly supported by columns without the use of intermediary beams (Figure 1a). To increase punching shear resistance of flat slabs, columns may be flared to form a column head (column capital) or the slab may be thickened around columns as a drop panel or both (Figure 1b). Flat slab systems are popular for use in office and residential buildings, hospitals, schools and hotels. They are quick and easy to formwork and build. The architectural finish can be directly applied to the underside of the slab. Absence of beams allows lower story heights and as a result, cost saving in vertical cladding, partition walls, mechanical systems, plumbing ( a) Flat slab without drop b) Flat slab with drop panels ) Figure 1: Flat slab systems in building construction and a large number of other items of construction especially for medium and high-rise buildings. They provide flexibility for partition location and allow passing and fixing services easily. Windows can be extended up to the underside of ceiling. The absence of sharp corners gives greater fire BEPLS Vol 2 (5) April 2013 62 P a g e 2013 AELS, INDIA

resistance and less danger of concrete spelling and exposing the reinforcement. Moreover, where the total height of a building is restricted, the use of a flat slab will result in more stories accommodated within the set height [13]. Design optimization of isolated reinforced or prestressed concrete slabs has been widely studied [4-6]. This paper presents cost optimization of RC flat slab buildings according to the British code of practice for design and construction of reinforced concrete structures, BS 8110, [7]. Structural analysis of flat slab buildings Equivalent frame method (EFM), recommended by BS 8110 [7] and several codes of practice (e.g. the American, Canadian and Australian codes), is used for the analysis of a flat slab building. In this method, the flat slab building having a rectangular plan is modeled as a sequence of longitudinal and transversal plane frames. Each frame consists of a row of equivalent columns and beams which represent the columns and the strips of slabs bounded laterally by centerlines of the panels adjacent to the centerline of the row of columns. In this study, it is assumed that equivalent frames are loaded by uniform gravity dead and live loads and lateral loads are resisted by other structural systems such as shear walls. Since the bending moment over the width of slab strips (equivalent beams) in equivalent frames is variable, the width of equivalent beam is divided into two strips, namely, column and middle strips. The actual moments are averaged over the width of these strips. The average bending moment over each strip is obtained as a percentage of the total bending moment at each section of the equivalent beam according to the recommended values by the code of practice. Required reinforcement at each section of the slab is calculated according to the obtained design bending moment in each section of column and middle strips as shown in Figure 2. Statement of the problem Design variables Consider a flat slab building having nf storey s of arbitrary heights and nx and ny spans of equal lengths lx and ly in x and y directions, respectively (Figure 2). The number of spans in the longitudinal and transversal directions of the building is used as design variable. Also cross-sectional dimensions, and the number and size of steel bars in a given section of RC elements are considered as design variables. The number of spans in each direction describes column layout of the structure. Figure 2 illustrates design variables in a typical floor of a flat slab building. The thickness of the floor slab, ti, and the number and size of reinforcement in different positions over the floor slab are the design variables. Figure 3 shows design variables for a column. To simplify the problem, it is assumed that all columns have rectangular cross-section, all steel bars have the same diameter and they are symmetrically concentrated in four corners of the section. Since it has been assumed that lateral loads are resisted by shear walls or another systems capable of withstanding lateral forces, there is no considerable shear force in the column section. Therefore, the size and spacing of column links are calculated according to the code recommendations to prevent outward buckling of the longitudinal bars and provide ductility of columns. Four different typical columns are considered in each storey, which are corner column, two edge columns in the longitudinal and transversal sides of the building and one intermediate column. Figure 4 shows a typical layout of shear reinforcement around a column-slab connection. The size of bars, φ, and the number of reinforcement in each layer, N1, N2 etc. are considered as design variables in a typical connection. The number of required layers of shear reinforcement for each column-slab connection depends on the magnitude of punching shear stresses around column. The use of column head can also be considered as an optional feature for increasing punching strength of slabs (Figure 5). The cross-sectional dimensions of a column head in contact with the floor slab are the design variables for the column head. A typical reinforcement detailing is considered for column heads. Therefore, the number and size of column head steel reinforcement are not considered as design variables. Four types of column-slab connections have been considered in each floor. These are a corner connection, two edge connections for columns located in longitudinal and transversal sides of the building and an intermediate connection. Objective functions and design constraints The objective function is the cost of labor and material for concrete, reinforcement and formwork for, nf, floors, nc typical columns and foundations and the cost of the foundation excavation for a quarter of the building. nf nc C = C i (x f ) + C j (x c ) + C f (x) (1) BEPLS Vol 2 (5) April 2013 63 P a g e 2013 AELS, INDIA

i=1 j=1 subject to: G i (x f, x c ) 1 i = 1, 2,..., n g, (2) Zandi et al x l j x j x u j j = 1, 2,..., n s, (3) x = (x 1, x 2,..., x n ) = (x f, x c ). (4) The first term in equation (1) represents the sum of the cost of floors, the second term is the sum of the cost of all typical columns and Cf is the total cost of the foundation including excavation for a quarter of the building. The foundation cost is approximately calculated by assuming all foundations are identical pad footings. The cost of shear reinforcement around columns and column heads has been also included in the cost of floors. In expression (2), Gi is the i-th behavioral constraint function which is resulted from a design provision. Expression (3) gives side constraint on jth design variable. In these expressions, x l j and xu j are the lower and upper limits for jth design variable and ng and ns are the total number of behavioral and side constraints, respectively. Design constraints are introduced according to BS 8110 [7] code requirements. These design constraints includes strength, serviceability, stability and ductility requirements Also architectural and practical considerations are applied to the problem. For example a Figure 2: Typical layout of bending reinforcement in a flat slab. Figure 3:Layout of shear reinforcement. BEPLS Vol 2 (5) April 2013 64 P a g e 2013 AELS, INDIA

Design optimization procedure The design optimization procedure is handled in three levels. In the first level different column layouts for a building of a given number of storey s, length and width of rectangular plan are compared to find the optimum number of spans in longitudinal and transversal directions. For each column layout, a model is constructed for structural analysis. Design optimization of the structure is then carried out as explained below and the total cost of the optimum structure for the defined column layout is calculated. The minimum total cost among all the results obtained for different column layouts identifies the optimum column layout. In the second level the section dimensions of columns and the thickness of slabs for each assumed layout are found. In this level a hybrid optimization algorithm based on a genetic algorithm (GA) [8] is employed. The algorithm includes two stages. In the first stage a modified GA is initially used for a global search to find the optimum or a near-optimum solution for the cross-sectional dimensions of the elements. In the second stage this solution is considered as a base point for a local search using a discredited form of Hooke and Jives method [9]. In the third level, using an exhaustive search method [10], the optimum amount of reinforcement (the number and diameter of bars) for each group of members with given dimensions and the column capital dimensions are determined. EXAMPLES AND DISCUSSION Two design examples will be presented. Table 1 gives information used in these design examples. It is assumed that there are no straps between pad foundations. Example 1 To determine the unit prices, Spon s Architects and Builders Price Book 2001 [11] and Harris [12] have been used. Table 2 shows the floor thickness and columns cross-section dimensions for the optimum and conventional designs. For the conventional design, cross-sectional dimensions of RC elements were fixed at the values shown in Table 2 and the design optimization program, developed in this study, was used for structural analysis and calculation of the size and number of reinforcement bars of RC elements. Table 3 compares the results of cost components for different elements of the optimum design with those of a conventional design. It is important to mention that with the optimum thickness of 220 mm, the required area of reinforcement at the middle of the two spans is governed by the deflection constraint. It means that the area of reinforcement in these spans has been increased as compared with that obtained from strength requirements. In other words, the increase of the amount of reinforcement at the middle of few spans has been more economical than increasing the thickness of the slab to satisfy deflection requirements. As Table 2 shows, the slab thickness for the optimum design is 30 mm smaller than that for the conventional design. Therefore, to prevent punching shear failure in the optimum design the cross-sectional dimensions of the edge columns on the edge parallel to x direction have been increased as compared with those of the conventional design. For this reason, as Table 3 shows, the total cost of columns for the optimum design is 3.3% larger than that for the conventional design, however optimum design produced 2.8% cost saving in the total cost of the building as compared with the conventional design. Table 1.Specifications of design examples Specification Ex. 1 Ex. 2 Number of spans in x direction 4 5 Number of spans in y direction 3 5 Length of spans in x direction (m) 5 7.5 Length of spans in y direction (m) 6 7.5 Number of storeys 1 3 Storey height (m) 4 3.95 Live load (N/m2) 5000 5000 Dead load (N/m2) 2500 1500 Characteristic strength of concrete (N/mm2) 35 35 Characteristic strength of main steel bars (N/mm2) 460 460 BEPLS Vol 2 (5) April 2013 65 P a g e 2013 AELS, INDIA

Characteristic strength of shear steel bars (N/mm2) 250 250 Allowable bearing pressure of soil (kn/m2) 200 200 Top cover of steel bars in floor slab (mm) 20 25 Bottom cover of steel bars in floor slab (mm) 25 25 Cover of steel bars in columns 40 40 Maximum bar diameter of main reinforcement of slabs (mm) 25 25 Minimum bar diameter of main reinforcement of slabs (mm) 10 10 Maximum bar diameter of main reinforcement of columns (mm) 25 32 Minimum bar diameter of main reinforcement of columns (mm) 10 10 Maximum bar diameter of shear reinforcement (mm) 12 12 Minimum bar diameter of shear reinforcement (mm) 6 6 Unit cost of concrete ( /m3) 55 53.5 Unit cost of reinforcement( /kg) 0.5 0.4 Unit cost of formwork ( /m2) 20 18.5 Excavation, disposal and backfill cost of soil ( /m3) 20 20 Table 2. Comparison of cost components of the optimum and conventional designs Thickness of Column dimensions (Cx Cy) (mm) Design floor (mm) Corner Edge (x) Edge (y) Inter. Optimum 220 250 250 250 300 250 250 250 250 Conventional 250 250 250 250 250 250 250 250 250 Table 3.Comparison of cost components of the optimum and conventional designs Total cost of Total approximate Total cost of Total cost of Design columns cost of foundation building floors ( /m2) ( /m2) ( /m2) ( /m2) Optimum 38.411 5.944 5.2 49.556 Conventional 39.811 5.756 5.411 50.978 Cost saving % 3.5-3.3 3.9 2.8 5.2- Example 2 This design example has been chosen from a report on the comparative costs of concrete and steel framed office buildings [13]. In this study, the average of the unit prices for each material, presented in the aforementioned report, is used in the design optimization of the building. First it is assumed that the span lengths are fixed in both directions as lx and ly are 7.5 m, i.e. nx and ny are 5. Figure 6 shows the comparison of the total cost components of concrete, reinforcement and formwork of the superstructure of the building obtained from the conventional and optimum designs. The breakdown of costs of the floors and columns is also shown in this figure. The total cost of the superstructure according to the conventional design is 55.46 /m 2, and according to the optimum design is 42.57 /m 2. As a result, design optimization of the structure has led to 23.3% saving. According to this figure the cost of floors and columns is about 89% and 11% of the total cost for the conventional design and 91% and 9% of the total cost for the optimum design, respectively. Those results show that the cost of floors is the major part of the structural cost and emphasize the importance of the optimization of floors in the flat slab buildings, as concluded by other researchers [13, 14]. It can be observed that the largest component of the overall cost is the cost of formwork (39% and 51% for BEPLS Vol 2 (5) April 2013 66 P a g e 2013 AELS, INDIA

the conventional and optimum designs, respectively). The cost of concrete contributes 33% and 36% of the structural cost for the conventional and optimum designs, respectively. The smallest component is the cost of reinforcement being 28% and 13% for the conventional and optimum designs, respectively. The largest cost saving is achieved by reducing the cost of reinforcement (63% cost saving). Since the main part of the formwork cost relates to soffit of the floors, which is identical for both of the conventional and optimum designs, the smallest cost saving is achieved for formwork (0.5% cost saving). In addition to the optimum sizes of structural elements, the optimum number of spans is also determined in this example. As already discussed the optimum column layout is specified by comparison of the minimum structural cost of different column layouts of the building. Figure 7 shows the variation of the minimum structural cost of the building with respect to the span lengths. The most economical span lengths are lx = ly = 5.357 m (i.e. nx = ny = 7). The total cost of the optimum superstructure per unit area of the building for the optimum column layout, the optimum and conventional designs of the previously assumed column layout, mentioned above, are 40.62 /m 2, Zandi et al 46.89 /m 2 and 63.56 /m 2, respectively. Therefore, the optimum column layout can Figure 4. Comparisons of cost items Figure 5. Comparisons of cost items produce 36% and 13% cost saving as compared with the conventional and optimum designs with fixed spans equal to lx = ly = 7.5 m, respectively. CONCLUSIONS This paper presents column layout and size optimization of Reinforced concrete (RC) flat slab buildings to BS 8110 code of practice. The objective function is the total cost of the building including the cost of floors, columns and foundations. The total cost of the building includes the cost of material and labour for reinforcement, concrete and formwork of structural elements. Excavation cost is also considered for foundations. The optimization process is handled in three levels. In the first level the optimum layout of building is determined through an exhaustive search. In the second level the optimum cross-sectional dimensions of RC elements are found using a hybrid algorithm based on genetic algorithm (GA). In the third level an exhaustive search is applied to seek the optimum size and number of steel bars for each individual type of structural elements. Two practical examples are given to demonstrate the achieved cost savings. REFERENCES 1. Goodchild, C.H. (1997), Economic concrete frame elements, Reinforced Concrete Council, Crowthorne, UK. 2. Mosley, W.H., Bungey, J.H. and Hulse, R., (1999). Reinforced concrete design MacMillan Press Ltd., London. 3. Fanella, D.A., (2000). Concrete Floor Systems, Guide to Estimating and Economizing, 2 nd ed., Portland cement Association (Pca), Illinois, USA. 4. Rozvany, G.I.N., (1967). The behavior of optimized reinforced concrete slabs, Institute of Engineers, Australia, CE9 (2), pp. 283-294. 5. Dutta, T.K., Ratnalikar, N.V. (1973). Optimal design of reinforced concrete slabs. Journal of Institute of Engineers, India, 54(C12): 47-52. 6. Sahab, M.G., Ashour, A.F., Toropov, V.V., (2000). Cost optimization of reinforced concrete flat plates. In nd BEPLS Vol 2 (5) April 2013 67 P a g e 2013 AELS, INDIA

roceedings of the 2 nd ASMO UK/ISSMO Engineering Design Optimization Conference, July 2000, Swansea, UK, pp.197-203. 7. BS 8110, (1997). Structural use of concrete, Part 1, Code of practice for design and construction, British Standards Institution, London. 8. Goldberg, D.E., (1989). Genetic Algorithms in Search, Optimization and Machine Learning, Addison-Wesley Reading, Massachusetts, USA. 9. Hooke, R., Jeeves, T.A., (1961). Direct search solution of numerical and statistical problems, J. of Assoc. Computer Mach., 8: 212-229. 10. Rao, S.S., (1984). Optimization theory and application, 2 nd edition, Wiley Eastern Limited, New Delhi, India. 11. Spon s Architects and Builders Price Book,(2001), 126 th edition, Spon Press, London. 12. Harris, E.C., CESMM3 price data base 1999/2000, Thomas Telford Ltd., 1999, London. 13. Goodchild, C.H., (1993). Cost model study, Reinforced Concrete Council, Crowthorne, UK. 14. Matthew, P.W. and Bennett, D.F.H., (1990). Economic long-span concrete floors, Reinforced Concrete Council, Crowthorne, UK. How to Cite this Article Yousef Z., Naziri R. and Hamedani R.(2013). Effect of Layout and Size Optimization Conditions in Architectural Design of Reinforced Concrete Flat Slab Buildings. Bull. Env. Pharmacol. Life Sci., Vol 2 (5): 62-68 BEPLS Vol 2 (5) April 2013 68 P a g e 2013 AELS, INDIA