Operation and Performance of the Gas In-Vitro Exposure System (GIVES)

Similar documents
DEVELOPMENT OF AN ELECTROSTATIC AIR SAMPLER AS AN ALTERNATIVE METHOD FOR AEROSOL IN VITRO EXPOSURE STUDIES. Jose Zavala.

CHAPTER 6 : GAS SAMPLING SYSTEMS

Figure 1. Few examples of in-vitro models developed using our products

OPTIMIZED DESIGN FOR HEAVY MOUND VENTURI

Fine Dust Sensor FDS 15. OUT ma

Unit Treatment Processes in Water and Wastewater Engineering

Total Dissolved Solids

Sampling method for particle measurements of vehicle exhaust

Analysis of the corrosion test process for heat exchangers in corrosion test chambers by CFD simulation

Sanitary and Environmental Engineering I (4 th Year Civil)

Testing of Carbon Filters in Australian

Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

Product Bulletin 2K-3.2. stamixco. mix it up..

MATERIALS OF CONSTRUCTION

Verification and Validation of Preliminarily Result of CFD of Electrostatic Precipitator Mr.Dharmendra Dekate 1 Mr.K.M.Narkar 2

Sample Conditioning Instruments. Jonna Kannosto Technical Marketing Specialist, PhD

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

ASSESSMENT OF AIR CHANGE RATE AND CONTRIBUTION RATIO IN IDEALIZED URBAN CANOPY LAYERS BY TRACER GAS SIMULATIONS

1. Monitoring and controlling urban pollution.

Sampling for particulates

Ameren Seminar August 19 20, 2008 Effingham, IL

Quenching steels with gas jet arrays

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

DEKATI EJECTOR DILUTER IN EXHAUST MEASUREMENTS V2.11

COMSOL Multiphysics Simulation of Flow in a Radial Flow Fixed Bed Reactor (RFBR)

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

Sampling for particulates

Oil Conservation in Biscuit Industry

Topic: TSF: Thermal Systems and Fluid Mechanics

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

CONTROL VOLUME ANALYSIS USING ENERGY. By Ertanto Vetra

INTERPHEX USA 80-1 ROUTINE EVALUATION OF FILM COATING PROCESSES. M. Talei, Pharm.D., Ph.D. ALZA Corporation Palo Alto, CA INTRODUCTION

VOC-TD Application Manual

Static Mixing, Reaction, Heat Transfer & Fluid Dynamics Technology

Lecture 4 Air Pollution: Particulates METR113/ENVS113 SPRING 2011 MARCH 15, 2011

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

Characteristics of Ultrafine Particles released From Laser Printers

An overview of CFD applications in flow assurance From well head to the platform. Simon Lo

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

A Hands-On Guide to Ultrafiltration/ Diafiltration Optimization using Pellicon Cassettes

Modelling Urea Distributions in SCR Exhaust Aftertreatment Systems. A Simple Approach.

Chambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber

CO 2 Recycling via Reaction with Hydrogen

THE RTM-LIGHT MANUFACTURING PROCESS: EXPERIMENTATION AND MODELLING

Chapter 2.6: FBC Boilers

PRESENTATION OF CONDENSATE TREATMENT

Atomic Structure of Ultrathin Gold Nanowires

Module 1: CHAPTER FOUR PHYSICAL PROCESSES

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Abstract. Introduction FILTRATION CHARACTERISTICS OF CMP SLURRIES. Author: Rakesh K. Singh, Ph.D., P.E., M.B.A.

CHAPTER 1 INTRODUCTION

A Review of NIOSH Manual of Analytical Methods Chapter DL Monitoring Diesel Particulate Exhaust in the Workplace

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE

Design and distribution of air nozzles in the biomass boiler assembly

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

Workshop Industrial application of SOFC systems: the DEMOSOFC project

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

PORTAL FRAMES 1.0 INTRODUCTION

Secondary Systems: Steam System

What is Aero microbiology?

CTB3365x Introduction to Water Treatment

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Solar Flat Plate Thermal Collector

Effect of Rotation Speed of a Rotary Thermal Wheel on Ventilation Supply Rates of Wind Tower System

Contamination of Successive Samples in Portable Pumping Systems

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Application of CFD for Analyzing Quenching and Quench System Design. Andrew L. Banka

New Statistical Algorithms for Monitoring Gene Expression on GeneChip Probe Arrays

Air Pollution Control Measures

"Post-combustion CO 2 capture by Ca-looping"

EQUIPMENT AND SYSTEM FOR VACUUM COATING METALLIZING, SPUTTERING, PLASMA and PECVD. Hybrid system KOLZER DGK 36

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

THE INFLUENCE OF CARRIER SIZE AND SHAPE IN THE MOVING BED BIOFILM PROCESS

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

VENTILATION REQUIREMENTS TO PREVENT PIT AIR UP-DRAFTING IN

Low-mass PM analyzer MEXA-1370PM Improvement of the Performance for PM Composition Analysis

PLUME ANALYSIS AND CFD MODELING FOR EFFECTIVE EAF MELTSHOP ENVIRONMENT CONTROL

will denote mass of suspension before the filtration in an accumulation tank, m F mass of filtrate, m K mass of produced filtration cake, m S

MODULE I. Learning Objectives

On-line Parameter Estimation and Control for a Pilot Scale Distillation Column

Bioreactors in tissue engineering

A MODEL FOR RESIDUAL STRESS AND PART WARPAGE PREDICTION IN MATERIAL EXTRUSION WITH APPLICATION TO POLYPROPYLENE. Atlanta, GA 30332

2. TECHNICAL DESCRIPTION OF THE PROJECT

Performance Standards for Continuous Ambient Air Quality Monitoring Systems. Environment Agency Version 8 June 2012

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Flue Pipe Considerations

HEAT RECUPERATION IN VENTILATION SYSTEM OF BASEMENT LABORATORY

POROSITY, SPECIFIC YIELD & SPECIFIC RETENTION. Physical properties of

High Efficiency Liquid-Solid Separators

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

CE3502. ENVIRONMENTAL MONITORING, MEASUREMENTS & DATA ANALYSIS. Inflow. Outflo

Effects of Atmospheric Pressure Plasma on Adhesion

The effects of Fe/Al 2 O 3 preparation technique as a catalyst on synthesized CNTs in CVD method.

CFD analysis of coolant flow in the nuclear reactor VVER440

COOLING TOWER DESIGN FOR CENTRAL GENERATORS OF CUET, BANGLADESH. Mohammad Sharif Khan, Golam Mainuddin, Abu Sadat Mohammad Sayem, Nadeem Nafis

Transcription:

Operation and Performance of the Gas In-Vitro Exposure System (GIVES) Supplement to manuscript APC-2012-1: Gaseous VOCs Rapidly Modify Particulate Matter and Its Biological Effects: Part 1, Simple VOCs and Model PM GIVES Components The Gas In Vitro Exposure System (GIVES) uses commercially available components. The modular incubator chamber (MIC; Billups-Rothenberg, MIC-101, Del Mar, CA) is an air-tight, eight-litre, two-part, polycarbonate chamber (31 cm in diameter, and 11 cm high) with a removable top and a gas-tight clamping ring. Removing the top permits open access to the plastic lattice mid-floor over the bottom portion of the chamber. Cell culture plates are placed on this grid during exposure (Fig. S1a). This unit was adopted because it has been commonly used in gas-cell exposure studies (Billups-Rothenberg, 2012). The chamber is operated in a temperature controlled incubator, as shown in Fig. S1b (maintained at 37 C). Air flows out of the MIC at the same rate that it enters. Below the plastic lattice mid-floor is a 2-cm deep cavity for air mixing from the 0.6 cm inlet and outlet tubes that extend partially across the diameter of the chamber bottom and open into the cavity space below the mesh (Fig. S1a). Air then flows up though the lattice into the top part of the chamber and randomly circulates over the open cell culture plates. a) b) Figure S1. Billups-Rothenberg modular gas exposure chamber housed in a tissue culture incubator. For cellular exposure, one or two multi-well tissue culture plates are placed into the eight-litre chamber, on the mid-floor (Fig. S1). Due to the open design of the MIC, plates with any number of cell culture membranes can be used, thereby providing flexibility in meeting the needs of any experimental design. Typically in the GIVES, six- or twelve-well plates are used with Transwell (Costar, Cambridge, MA) cell culture membranes (similar in design to those shown in Fig. S2a). This allows cells to be exposed at air-liquid interface while the bottom volume of each cell culture well (below the membrane) is filled with

appropriate media for the cells. Each Transwell has cells plated on its porous membrane (Fig. S2b). The Transwells used in the work described in the manuscript associated with this supplement were 12 mm in diameter, with the membrane on which cells are grown 17 mm below the top of the well. The membrane area was 1.12 cm 2. a) b) Figure S2. a) Costar Transwell cell culture membranes (24 mm diameter, 6-well tissue culture plate); and b) Adding cells to 12 mm diameter membranes (in a 12-well tissue culture plate).

GIVES Flow Regime The inlet of the MIC is connected via Teflon tubing to a sampling manifold coupled directly to the roof-top smog chamber just above the laboratory (Fig. S3 and Fig. 1 of the associated manuscript). Figure S3. Multiple conditioned sample lines from the roof as they enter the laboratory immediately below the chamber. An idealized model of the interior of the MIC for our operating conditions is a Continuous Stirred Tank Reactor (CSTR; mass balance described below). In this model: a) gases and particles flow in the reactor volume and are mixed with previous gases and particles; b) gases undergo chemical reaction, surface loss, or uptake by cells; and c) well-mixed gases and particles flow out of the reactor. In an ideal reactor, the mixing is assumed to be instantaneous. In practice, a generally accepted approximation of this condition is the mixing is complete after flowing once around the reactor under turbulent conditions. In the MIC, the lattice mid-floor that separates the inlet/outlet area from the cell exposure area assures that sufficient turbulence or shear is introduced to give random mixing. As a result of the (near) ideal mixing, the composition of the gases and particles is the same everywhere in the reactor and in the exhaust.

A mass balance on the chamber is described by equation (2) and leads to a definition of a time constant, τ. For our system (with f = 1.0 L min -1 and V = 8.0 L) has a τ value of 8 min and, with steady concentrations in the inlet flow, leads to stead-state concentrations in the MIC for times greater than 56 min. Exposures in the MIC are 3 5 hours in duration with nearly constant chamber conditions during exposures. As stated in the Methods section of the manuscript associated with this supplement, exposures in this work lasted 4 hours.

GIVES Replicate Exposure Results for Clean Air and for Gas Mixtures To account for variability in each new cell passage, which might have a slightly different absolute response, for each exposure test there are paired 'incubator' and 'clean air' control exposures that are processed in parallel with the pollutant-exposed cells. Cytokine analyses produce quantitative measures of the cytokines expressed due to exposure, and always include results from the unexposed cells. Results are then reported as a ratio of the test exposure response to the clean air exposure response (pollutant exposures are normalized by their associated clean air exposure). This is often referred to as a "fold increase over controls" in the toxicological literature. In Figs. S4 and S5, this "fold increase" is plotted for inflammatory response (IL-8 expression) for each individual cell membrane exposed in plates for two different gas-phase exposures. Each time new cells are acquired from a cell culture supplier, they undergo standard exposure tests to clean air ( zero effect exposure) and to 400 ppb ozone ( positive response exposure) for 4 hours before being used in real exposure experiments. The white bars in Fig. S4a show IL-8 expression as fold increases for a 4-hour exposure to clean chamber air flowing through the GIVES (refer to Methods section of the associated manuscript for details on clean air preparation). The blue bars in Fig. S4b show IL-8 expression for fold increases for exposure to photochemically aged SynUrb54 VOC/NOx mixture with no PM (ozone, NO x, and secondary VOCs including aldehydes) flowing through the GIVES (see condition E in Table 2 of Ebersviller, et. al, 2012a). Figure S5 shows well-by-well results for a 12-well plate holder for one such an ozone test. The replicate numbering scheme in Figs. S4 and S5 follow the layout shown in Fig. S6. Another way to interpret the results shown in Figs. S4 and S5 is that these data illustrate a combination of the uniformity in cellular response and gas conditions over the exposure plate. In the tests included in Fig. S4, only half of the plate contained membranes (the remaining wells were left empty), while the test shown in Fig. S5 had membranes in all 12 wells. Results over these and many other tests with filled and partially filled 12-well plates show no discernible systematic differences in response associated with the location of a cell membrane on the tissue culture plate.

a) b) Figure S4. IL-8 (inflammation) individual well relative responses for 4-hour GIVES exposures to: a) clean chamber air exposure, Standard Error (S.E.) = 6.6%; and b): Aged SynUrb54 VOC/NOx mixture, S.E. = 12.3%. Figure S5. IL-8 (inflammation) individual well relative responses for 4-hour GIVES exposures to 400 ppb ozone in clean air, S.E. = 5.5% Figure S6. Physical location of replicates on a 12-well tissue culture plate (by ID number)

Exposure of cells in GIVES to PM As described in the associated manuscript, particles were present in the sample stream that went to both the GIVES and the EAVES. PM with diameters less than 1000 nm are hard to collect on cell-culture membranes without external forces being applied. The mineral oil aerosol (MOA) used in this study was typically at a mass concentration of 1.4 mg m -3 in the chamber, and the measured number-mode diameter was ca. 200 nm, which is similar to measured distributions of diesel exhaust particles in previously reported work (that range from 200-500 nm; de Bruijne, 2009). By employing particle charging and a high voltage electrostatic field, the EAVES sampler deposited ca. 1.5 μg of PM (per well) from the sample stream in 1 hour. The only significant forces acting in the GIVES, however, were gravity and the mixing of new and old air volumes caused by the 1 L/min sample flow. As was explained in the section above, there is no organized flow over the cell wells. The measured cellular responses imply that the conditions above each well were similar (on average). Moreover, gravitational settling velocity for the mass-mode-diameter particles in the test conditions (ca. 1000 nm, at 82 particles per cm 3 ) is 2.86 x 10-3 cm-s -1 (Hinds, 1999). Turbulent air mixing length exceeds this distance. Nevertheless, if we make the counterfactual assumption that air in the MIC was motionless, we could estimate the time required to achieve the same PM mass deposition in the GIVES that we obtained in the EAVES in 1 hour. If there were no flow and the air column were maintained above the cells, it would require ca. 150 days to obtain the same mass deposition in GIVES as was collected in the EAVES in 1 hour. At the other extreme, if we make a counterfactual assumption that every particle entering the GIVES were deposited uniformly over the entire sampler floor surface (including the cell wells), we would still need 12 hours to collect the same mass as was collected in the EAVES in 1 hour. Of course, there is no force or mechanism in the GIVES that would result in all or even a significant fraction of PM being deposited. Thus, cells in the GIVES do have some (likely very small) exposure to PM in the air stream, but the extent is so limited that it cannot be detected by biomarker changes. These conditions in the GIVES make this sampler virtually a gas-only sampler (when the PM present is smaller than 1000 nm).

References for Supplement Billups-Rothenberg: http://www.brincubator.com/faqs.htm, last access: 8 December 2012. de Bruijne, K., Ebersviller, S., Sexton, K. G., Lake, S., Leith, D., Goodman, R., Jetter, J., Walters, G., Doyle-Eisele, M., Woodside, R., Jeffries, H. J., and Jaspers, I.: Design and Testing of Electrostatic Aerosol In Vitro Exposure System (EAVES): An Alternative Exposure System for Particles, Inhal. Toxicol., 21, 91 101, 2009. Ebersviller, S.: Gaseous VOCs rapidly modify particulate matter and its biological effects Part 2: Complex urban VOCs and model PM, Atmos. Chem. Phys. Discuss., submitted, 2012a. Hinds, W.C.: Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles, John Wiley Sons, New York, NY, 2nd ed., 1999.