Code Compliance: Greater weather performance B1 - Structure Acceptable solution: Cost effective solution Alternative solution: B2 -Durability

Similar documents
Metalcraft. Roofing ESPAN

Metalcraft. Roofing RAINWATER SYSTEMS

Metalcraft. Roofing METAL TILES

MULTIrib PROFILE TECHNICAL SUMMARY. Multirib lap. Multirib (Roofing and Wall Cladding) Dimensioned Drawing of Multirib

Metalcraft. Roofing OUR OFFER TO YOU. 1

Cyclonic Area. Design Manual. Using TOPSPAN profiles and LYSAGHT roofing and walling claddings in cyclonic areas

Stramit Patio Roofing Cyclonic Span Tables

Cyclonic Areas Roof & Wall Cladding

CUSTOM ORB CUSTOM BLUE ORB

B5 for garages, equestrian and other single storey buildings

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

THERMAKRAFT ALUBAND WINDOW FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 878 [2014]

CUSTOM ORB ACCENT 35 DESIGN AND INSTALLATION GUIDE

Corrugated sheet for single storey, sectional buildings and stables

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

ROOFING AND CLADDING SYSTEMS MANUAL

Eziform Ridge Vent Natural Roof Ventilators

FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 800 [2013] Appraisal No. 800 (2013) Amended 05 February 2016.

FARMBOSS. UV Resistant Fully Sealed Flexible Joint System Light Weight WE PIPE ( )

SUPERCOURSE 500 DAMP-PROOF COURSE AND CONCEALED FLASHING. Product. Scope. Building Regulations. Appraisal No. 329 [2016]

Sandwich panel SPA Product description

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials

REINFORCING PRODUCT CATALOGUE MESH PRODUCT CATALOGUE MESH JAN 2013 S&T025

NZS :2008. Glazing in buildings NZS :2008. Part 4: Wind, dead, snow, and live actions. New Zealand Standard

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

ROOF RENOVATION OVERSHEETING SYSTEM

Product Data Sheet. QuadCore Karrier. Applications

Insulated Panel Systems. 1, d0 IND E N 1350

June GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual

Core. Thickness. Biological

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

bull-nosed verandah Construction guide using custom blue orb

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

Global Roofing Solutions Zip-Tek 420 TM

RUUKKI FORMA DESIGN INSTRUCTION

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

LAKE BARRINGTON COMMUNITY HOMEOWNERS ASSOCIATION 64 Old Barn Road Lake Barrington, Illinois Phone: Fax:

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel

Western States 7/8 Corrugated

PROFILE S6 CORRUGATED SHEETS

Roof Systems. Span Tables & Thermal Ratings. Custom Roof Panel

INSULATED PANEL OVERVIEW

Flashings Materials Longitudinal flashings. 10 Ends of sheets

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Skellerup Pitched Roofing Systems. The Superior Shingle Look

BGC STRATUM AND STRATUM DUO CAVITY CLADDING SYSTEMS. Product. Scope. Appraisal No. 847 [2013] Appraisal No. 847 (2013) Amended 14 October 2015

ALLMET CONTINENTAL INSTALLATION GUIDE

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

ROOFING & WALLING INSTALLATION MANUAL FOR DESIGN AND INSTALLATION PROFESSIONALS 2017 EDITION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

A GUIDE TO WINDOW AND DOOR SELECTION

Box Culverts. Designers and manufacturers of engineered box culvert solutions

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

Building Regulations

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

60 years. of progressive development

Building Design Data

PALLISIDE CELLULAR upvc WEATHERBOARD DIRECT FIXED CLADDING SYSTEM. Product. Scope. Appraisal No. 490 [2015]

FIRMLOK FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL

PRIMA CERAMIC TILE UNDERLAY. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 636 [2008]

BENCHMARK Evolution Axis

At last! Construction bracing made easy...

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

PRE-ENGINEERED METAL BUILDING SYSTEM

GRP Flat Roofing Edge Trims

STRUCTURAL SYSTEMS MANUAL

BEARING METAL STUD FRAMING

Gold Bond BRAND Gypsum Sheathing

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

Onduline Oversheeting Benefits. Onduline Sheet Specification. Insulation. The Onduline colour range

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF

composition. Environmental Choice) as having lower environmental impact. Certification and further information is available at

POST FRAME BUILDING STANDARDS

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

BUILDING PRODUCTS LCP SPANLOCK. Metal Roof & Wall Cladding System

RS32 Multi-Section Skylight System under/over seam clip double diverter

TECHNICAL INFORMATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ROOF MOUNT KIT OWNERS MANUAL

(Project Location) (your firm's name)

INSTALLATION MANUAL Heritage Series

August Corus Colors. Colorcoat. Technical Paper. Creating an air-tight building envelope

Joint Evaluation Report ICC-ES (800) (562)

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA

Metro Roofing Products, a company

Flat roof for the loading-optimized elevation (adhesive system)

Transcription:

Elegantly Strong

Code Compliance: B1 - Structure Acceptable solution: Kāhu can be installed as per the loadspan, fixing requirements and expansion requirements as per E2/As1. Alternative solution: Kāhu has been load span tested to AS/NZS 1170.2 at the Metal Roll-formers Manufactures Associations testing facility in Huntly, New Zealand. Please refer to load span tables - AS/NZS 1170.2 and relevant guidance notes. Greater weather performance The double capillary overlap provides an extra capillary barrier to the standard capillary groove, giving you extra peace of mind. Cost effective solution The double capillary overlap requires only a one rib lap. This increases the cover sheet size and speeds up installation time. For wall cladding applications the exposed capillary groove on the overlap can be omitted providing for a smoother appearance. B2 -Durability Kāhu is manufactured from New Zealand steel, COLORSTEEL ENDURA or COLORSTEEL MAXX depending on environmental categories. New Zealand Steel s base material complies with AS/ NZS 2728:2013 - Prefinished / pre-painted sheet metal products for interior / exterior building applications. Double capillary overlap COLORSTEEL ENDURA prepainted steel is warranted by New Zealand Steel to meet the performance requirements of NZBC B2.3.1(b) for a 15 year durability when used for the manufacture of roof and wall claddings. COLORSTEEL MAXX prepainted steel is warranted by New Zealand Steel to meet the performance requirements of NZBC B2.3.1(b) for a 15 year durability when used for the manufacture of roof and wall claddings. E2 - External Moisture Acceptable solution: E2/As1 8.4.4 classifies Kāhu as a type b) trapezoidal profile. Kāhu is a symmetrical profile with crests widths at centers less than 210mm and crest heights are greater than 19mm. Minimum pitch for Kāhu is 4 degrees (As required by Metalcraft Roofing). Where the building is designed to comply with E2/As1, the spans and fixings must be accordance with those specified in E2/As1. Alternative solution: Compliance is supported by: Kāhu has been load span tested to AS/NZS 1170.2 at the Metal Roll-formers Manufactures Associations testing facility in Huntly, New Zealand. Please refer to load span tables - AS/NZS 1170.2 and relevant guidance notes. Supporting Evidence: In-service history of screw fixed trapezoidal profiles similar to Kāhu in New Zealand for at least 20 years and these have performed. The base material for Kāhu has been supplied for roofing and cladding applications for over 30 years. Refer to Metalcraft Roofing s installation details, specifications and loadspan and fixing tables. These can be downloaded from www.metalcraftgroup.co.nz. Metalcraft Roofing is a member of the New Zealand Metal Roofing Manufacturers Association Incorporated (NZMRM) and the NZMRM Code of Practice is additional evidence that can be used to support the above statements. The Code of Practice can be downloaded from: www.metalroofing.org.nz. Style and performance Kāhu has been designed for elegance, style and extra performance in mind and is Metalcraft Roofing s new roof profile. The ribs create strong defined shadow lines and combined with the double capillary barrier provides for greater weather performance. High strength steel G550 from New Zealand Steel is used to give the product extra strength and rigidity. Kāhu is a symmetrical profile and is available reverse run. A variety of colours and coating options from New Zealand Steel are available and are especially suitable for NZ conditions. Sheet Width / Cover Width Roof Pitch Cladding Sheet Lengths Options Manufactured 950mm / 875mm 4 minimum pitch. Pitch must increase to accommodate rainwater run off requirements. Refer to comments on reverse and the NZMRM code of practice section 4.8.2. Horizontal or vertical wall cladding Specify without the double capillary for a smoother appearance for wall cladding only. Dependant on chosen colour and freight / site limitations. Reverse run is possible for wall cladding options only Metalcraft Roofing - Christchurch branch. Available nationwide. Steel Options 0.4mm and 0.55mm BMT G550 Steel COLORSTEEL ENDURA and COLORSTEEL MAXX. For other metals please contact Metalcraft Roofing.

Cross Section All dimensions are nominal Sheet Width = 950mm Cover Width = 875mm 19 32 19 97.5 Loadspan tables - Alternative Solution: The following load span tables are to be used when the building falls outside the scope of E2/As1 and NZS 3604 or where the building is required to be specific designed. Loadspan tests have been carried out as per the parameters set out in the NZMRM Code of Practice - section 15 and in accordance with: AS/NZS 1170 - Minimum design loads on structures AS/NZS 1170.2 Part 2 - Wind Loads AS/NZS 1170.1 Part 1 - Dead and live load combinations Fixing patterns: - Alternative Solution: Hit 1, miss 2... Fixings: - Alternative Solution: Timber: 14G Length to suit -minimum embedment into structure to be 30mm and greater than 6 times the screw thread diameter. Use load spreading washers if required for expansion. Expansion - Alternative Solution: See page 5 DESIGN LOAD High strength 0.4mm BMT Kāhu Graph has been discounted by a 1.17 variability factor 5.0 Steel: 12G self-drilling fastener. Length to suit -minimum steel embedment should be 5-6mm beyond the drill point with a minimum of 3 threads beyond the drill point. Use load spreading washers if required for expansion. DESIGN LOAD High strength 0.55mm BMT Kāhu Graph has been discounted by a 1.17 variability factor 5.0 Load Kpa (Serviceability Limit State -SLS) 4.0 3.0 2.0 1.0 Load Kpa (Serviceability Limit State -SLS) 4.0 3.0 2.0 1.0 0 0 0.9 1.2 1.5 1.8 2.1 2.4 2.6 0.9 1.2 1.5 1.8 2.1 2.4 2.6 Intermediate span in meters Intermediate span in meters Note: The intermediate spans shown in the graphs above are based on G550 Steel as the base metal. To calculate end spans please multiply the intermediate span by 0.66. Spans are based on unrestricted access and allow for a concentrated load of 1.1kN. For alternative metals please contact your local Metalcraft Roofing branch.

Loadspan tables - E2/As1 Acceptable solution: Kāhu roofing and cladding profile complies with the New Zealand Building code and can be used in all wind zones as described in E2/ As1. If an architect, designer or engineer is designing a building in full accordance with E2/As1 then it is necessary for the design spans and fixings to comply with those of E2/AS1. The wind zones are given in NZS 3604 as: Low, Medium, High, Very high and Extra high. For full compliance the following spans and fixing patterns should be used. Please note E2/AS1 spacings are conservative and a specific design is permitted under E2/AS1 - for specific design reference should be made to the load span tables engineered to AUS/NZ 1170. PART 2. as indicated in Kāhu loadspan tables- Alternative solution. For low and Medium wind zones and with a fixing pattern of: Hit 1, miss 1... A maximum intermediate span of 1.2m and end span of 0.8 is required for 0.4mm BMT and for 0.55mm BMT maximum intermediate span is 1.8 m and end span 1.2m. For high and very high wind zones and with a fixing pattern of: Hit 1, miss 1...A maximum intermediate span is 0.6m and end span 0.4m is required for both 0.4mm and 0.55mm BMT. For high and very high wind zones and with a fixing pattern of : Fix every crest, a maximum intermediate span of 1.2 m and end span 0.8m is required for 0.4mm BMT and for 0.55mm Maximum intermediate span is 1.8 m and end span 1.2m. For extra high wind zones and with a fixing pattern of : Fix every crest, a maximum intermediate span is 1.2 m and end span 0.8m required for 0.4mm BMT and for 0.55mm Maximum intermediate span is 1.8 m and end span 0f 1.2m. For intermediate spans greater than 1.2m specific engineered design is required for 0.4mm BMT for all wind zones please use load span tables engineered to AUS/NZ 1170. PART 2. as indicated in Kāhu loadspan tables- Alternative solution. Fixing patterns - E2/As1 Acceptable solution: Fix every crest... Hit 1, miss 1... Fixings -E2/As1 Acceptable solution: If the architect, designer or engineer is designing a building in full accordance with E2/As1 then it is necessary for the design spans and fixings to comply with those of E2/AS1. Specific design is permitted under E2/AS1 - for specific design and where reference has been made to the load span tables engineered to AUS/NZ 1170. PART 2. as indicated in Kāhu loadspan tables- Alternative solution. Then the architect, designer and engineer should use Fixings as per indicated under: Fixings: - Alternative Solution. When the architect, designer and engineer chooses for spacings and fixing to both fully comply with E2/As1 then all fixings are required through the crest and must comply with Class 4 of AS 3566: Part 2. Timber: Screw fixings are recommended for metal roofing. Minimum of 12 gauge screw fixings with a 30mm minimum embedment into the timber purlins. Nail fixings are required to have a minimum of 40mm embedment into timber purlins. Sealing washers: Neoprene with a carbon black content of 15% or less by weight. Profiled washer and EPDM washers should be used where required for expansion of the profiled metal roof. Refer to expansion provisions. Every crest to: Ridge, Hip, Valley, Gutter and Periphery Areas must be fixed. Expansion provisions - E2/As1 Acceptable solution: No requirements for sheets upto 8m. For sheets between 8-18m use on top 50% of the sheet closest to the ridge, conventional fixings and neoprene washers, on remainder of the sheet use profiled washer and EPDM washer to allow for expansion. Sheets longer than 18m require specific design.

Product Application: The correct application of each grade of material is critical to product performance and life expectancy. Before commencing a project the user must refer to the environmental guide, the product data, the handling and storage guide and the installers guide as produced by New Zealand Steel. Minimum Pitches: The minimum pitch is determined by the ability of the roof cladding to discharge maximum rainfall without water penetration through the side laps, end laps or flashings. The minimum pitch for Kāhu is: 4 degrees for sheet lengths of 40m. 5 degrees for sheet lengths exceeding 40m but less than 60m. The above minimum pitch requirements have been calculated assuming peak rainfall to be less or equal to 100mm/hr. Please note the maximum sheet lengths for Kāhu are determined by the chosen colour and roof application. Expansion Provisions and Maximum Sheet Lengths - Alternative Solution: The NZMRM code of practice gives recommendations for roof cladding expansion provisions and these provisions are as follows: The expansion of roof cladding depends on the materials, the constraints imposed by the fixing, the heat paths in the building and of course the actual temperature. Favourable circumstances are; Flexible Light Gauge Steel purlins <3mm Light coloured roof cladding Purlin spacings greater than 1.5m Crest fixing Building not insulated Ventilated air space below roof cladding and underlay Low rib profile Handling and Storage: Detailed information is included in the New Zealand Steel Installers Guide. Important considerations are as follows: Site Storage which ensures that sheets are kept dry and ventilated. Reducing risk of surface damage to surface coatings during handling, installation and by other trades. Ensuring that spans and pitches used are not outside those recommended by Metalcraft Roofing. Ensuring that correct and sufficient fasteners are used. Installation in contact with incompatible Fasteners: The selection of the appropriate fastener is essential to performance of the roof. The durability of the fastener should be, as a minimum requirement, equal to that of the roofing or cladding. If in doubt, refer to your nearest Metalcraft Roofing branch. Environmental: The correct grade of material for use in various environments is given in the New Zealand Steel Environmental Guide. Disclaimer: As part of Metalcraft Roofing s policy of continued improvement, final specifications may vary from those contained in this publication. The company reserves the right at any time and without notice to change the design, materials or features and withdraw products from the market without incurring any liability whatsoever. This publication is issued as a general guide only and should not be treated as a substitute for technical advice. Contact with your nearest Metalcraft Roofing branch is recommended to confirm current specifications and availability. Quality Rest Assured Kāhu is manufactured from locally sourced NZ Steel COLORSTEEL so you can trust Kāhu to endure for many years to come. Light Steel upto 24m lengths and Dark Steel upto 18m lengths require no special requirements. Light Steel 24m -30m lengths and Dark Steel 18m - 24m lengths require 9mm oversized holes and load spreading washers. Light Steel over 30m lengths and Dark Steel over 24m lengths require a step Joint or other special provision. Unfavourable circumstances are; Purlins made of hot rolled steel or thicker than 3mm Laminated timber purlins Purlin spacing less than 1.5 m Pan fixing Dark coloured roof cladding Insulation close to the roof cladding Skillion roof Rigid profiles e.g. high rib Light Steel upto 18m lengths and Dark Steel upto 15m lengths require no special requirements. Light Steel 18m -25m lengths and Dark Steel 15m - 25m lengths require 9mm oversized holes and load spreading washers. Metalcraft Roofing are members of the Metal Rollformers Manufacturers Association Incorporated and the Roofing Association of New Zealand and this brochure should be read in conjunction with all technical information available from these associations and from the Metalcraft Roofing technical literature available on www.metalcraftgroup.co.nz Light Steel over 25m lengths and Dark Steel over 25m lengths require a step Joint or other special provision. These are guidelines only and refer to roof cladding only, special engineering of the roof, or fixing, or ventilation may allow for greater spans.

Metalcraft Roofing Branches: Whangarei 42-44 Rewa Rewa Road, Whangarei T: 09 470 0870 F: 09 470 0879 PO Box 5054 Whangarei E: sales.whangarei@metalcraftroofing.co.nz Auckland East Tamaki 26 Trugood Drive East Tamaki, Auckland T: 09 273 2820 F: 09 274 0251 PO Box 51286 Pakuranga, Auckland E: sales.aucklandmanufacturing@metalcraftroofing.co.nz Hamilton 25 Sheffield Street, Hamilton T: 07 849 3807 F: 07 849 6889 PO Box 10113 Te Rapa, Hamilton E: sales.hamilton@metalcraftroofing.co.nz Franchised Operations: Auckland North Shore 4 Silverfield, Wairau Park, Glenfield, Auckland T: 09 444 1813 F: 09 444 9799 PO Box 316043 Wairau Valley Post Centre, Glenfield, Auckland E: sales.auckland@metalline.co.nz Tauranga 42 Poturi St, Tauriko, Tauranga T: 07 575 7032 F: 07 575 7013 E: sales.tauranga@metalline.co.nz Rotorua 15 Monokia Street, Rotorua T: 07 350 1138 F: 07 350 1148 PO Box 388 Rotorua E: sales.rotorua@metalline.co.nz New Plymouth 218 De Havilland Drive, Bell Block, New Plymouth T: 06 755 2113 F: 06 755 0021 PO Box 3064 Fitzroy, New Plymouth E: sales.newplymouth@metalcraftroofing.co.nz Palmerston North 76 Malden Street, Palmerston North T: 06 358 9149 F: 06 358 7967 Freephone: 0508 589 145 Private Bag 11026 Manawatu Mail Centre, Palmerston North E: sales.palmerston@metalcraftroofing.co.nz Hastings 1454A Omahu Road, Hastings T: 06 873 9020 F: 06 879 8284 PO Box 2222 Stortford Lodge, Hastings E: sales.hastings@metalcraftroofing.co.nz Wellington 201 Gracefield Rd, Seaview, Lower Hutt T: 04 566 2253 F: 04 566 2256 PO Box 38509 Wellington Mail Centre, Lower Hutt E: sales.wellington@metalcraftroofing.co.nz Christchurch 85 Columbia Ave, Hornby, Christchurch T: 03 349 7350 F: 03 349 7365 Freephone 0800 333 056 PO Box 33056 Barrington, Christchurch E: sales.christchurch@metalcraftroofing.co.nz Satisfaction guaranteed Metalcraft Roofing has more than 50 years experience in the roofing industry which ensures your satisfaction is guaranteed. With 12 branches nationwide we pride ourselves on being New Zealand s largest and most established privately owned building product rollformer and installer with an extensive range of longrun roofing profiles, lightweight metal tiles. metal fencing, rainwater system solutions and a variety of solar generation solutions. We also have a structural steel and insulated panel division. For more information on Metalcraft Roofing visit: www.metalcraftgroup.co.nz Metalcraft Roofing is part of United Industries Ltd. For more information on United Industries visit: www.unitedindustries.co.nz Image of Kāhu on front cover Simon Larkin Design. Cromwell 20 McNulty Road, Cromwell T: 03 445 4180 F: 03 445 3581 PO Box 193 Cromwell E: sales.cromwell@metalcraftroofing.co.nz Brochure created January2016 version 1.