HPCE-5 2. A Revolution in Capillary Electrophoresis. High Performance Capillary Electrophoresis

Similar documents
HPCE-5 2. Realising the potential of Capillary Electrophoresis. Why is the HPCE-512 so much better?

Automated and quantitative

LabChip GXII: Antibody Analysis

Explore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Comparison of Different Brands of Carrier Ampholytes for Monoclonal Antibody Charge Heterogeneity Analysis by Capillary Isoelectric Focusing

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

Capillary Electrophoresis of Proteins

LabChip 90 System with DataViewer Software

Peptide Mapping: A Quality by Design (QbD) Approach

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Application Note. Biopharm. Author. Abstract. Christian Wenz Agilent Technologies, Inc. Waldbronn, Germany

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Thermo Scientific GENESYS 10S Bio spectrophotometer

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

XactEdit Cas9 Nuclease with NLS User Manual

CRISPR/Cas9 Gene Editing

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Fusion Analytical Method Validation

Protein Quantitation using various Modes of High Performance Liquid Chromatography

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

BÜCHI Labortechnik AG

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Conjugated protein biotherapeutics

SCION GC Series. The Gas Chromatographers Choice for Separations

QUANLYNX APPLICATION MANAGER

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Innovations To Meet Your Needs

CSE Separation of Cancer Cell Lysate

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Guide. recombinant DNA proteins. for the elaboration of monographs on synthetic peptides and. European Pharmacopoeia

Maximizing the Performance of Capillary Electrophoresis Systems The Maximizing Data Quality Series Part 4

Capillary Electrophoresis in Quality Control PART II: CE-SDS: Method Development and Robustness

PERFORMANCE MADE EASY REAL-TIME PCR

YSI 2900 Series Biochemistry Analyzers BIOPROCESS FOOD & BEVERAGE BIOFUELS MEDICAL RESEARCH

PA 800 plus Catalog. Systems/Software

QImaging Camera Application Notes Multicolor Immunofluorescence Imaging

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Determination of Isoelectric Point (pi) By Whole-Column Detection cief

Instrument specifications Technology Software Host interfaces Printer interfaces Data Station Physical dimensions Weight Certifications

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Assay of IgG Purity and Heterogeneity using High-Resolution Sodium Dodecyl Sulfate Capillary Gel Electrophoresis

DNA Workflow. Marine Biological Laboratory. Mark Bratz Applications Scientist, Promega Corporation. August 2016

Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

Agilent solutions for contract research and manufacturing organizations

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Introducing Agilent s Next Generation Capillary Electrophoresis System

Formulation Development

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

A universal chromatography method for aggregate analysis of monoclonal antibodies

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

Proteomics PA 800 (Beckman) ProteomeLab System (Detect Instrument Picture to Jump to that section of SOP)

Capillary Electrophoresis: Principles and Practice

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

-PLEX. Immunogenicity Assay Application Note. Measuring anti-drug antibodies (ADAs) to two different drugs using a multiplex bridging assay

Explore the future of osmometry. Multi-Sample Micro-Osmometer

Flow Cytometry - The Essentials

APPLICATION NOTE. Application Note. Summary/Abstract:

Antibody Analysis by ESI-TOF LC/MS

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

electrophoresis tech Performance Comparison of the Experion Automated Electrophoresis System and SDS-PAGE for Protein Analysis

Qualification of High-Performance Liquid Chromatography Systems

SCION GC Series. The Gas Chromatographers Choice for Separations

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

QIAcube HT Your Purification Expert

Protein stability assessment after automated buffer exchange

Mass Spectrometry for Characterization of Monoclonal Antibodies: Regulatory Considerations

BioHPLC columns. Tim Rice Biocolumn Technical Specialist

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Surface Plasmon Resonance Systems

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform

Transcription:

A Revolution in Capillary Electrophoresis High Performance Capillary Electrophoresis

Revolutionary Performance Continuous Monitoring of Capillary and Buffer Conditions Sensitive Label-Free 512 Times Better The HPCE-512 combines innovative detector technology with sophisticated signal processing algorithms to provide demonstrably better data. Conventional CE systems are built around single point detectors. By integrating a 512 pixel detector into the design, the HPCE-512 is able to track particles moving through the capillary in real time. Particle tracking algorithms are then able to filter out background noise from thermal or electrical sources, or identify problems in the buffer or capillary condition. The result is sample analysis with an ultra-low background. And when the background is low, small perturbations in the signal are easy to identify, resulting in a technique with a sensitivity which outstrips other CE instruments on the market and, in many situations, beats other techniques such as liquid chromatography too. The schematic above shows the complex conditions in a typical Capillary Electrophoresis system. The surface chemistry of the fused silica capillary introduces charge layers to the buffers which can induce different movements of the buffer, preventing the efficient, repeatable separation of the analysis. The HPCE-512 is able to monitor these effects, giving rapid feedback to the analyst on the success of a separation, allowing a unique internal quality control procedure. This is vital tool in QA/QC and diagnostics. Repeatable Resolution arb 8m 7m 6m 5m 4m EVA Robust & Highly Repeatable The advanced algorithms used in the HPCE-512 constantly monitor the condition of the capillary, identifying deteriorating conditions and eliminating compromised data. As a result, repeated analyses have excellent precision and the days of collecting degraded, unusable data are over! Data to Exceed your Expectations 3m Label-Free Time & Cost Saving 2m 1m The improvement in sensitivity results in the ability to run many more samples without the costly and time-consuming task of adding fluorescent labels to samples. 0 5 6 7 8 9 10 11 Time (mins) Unrivalled Resolution Example - Ribonuclease B and its 5 glycoforms The image shows the Capillary Gel Electrophoresis of this glycoprotein with resolutions of <200Da. The glycoforms differ by 1 Mannose unit (162Da). The 5 runs show highly repeatable data quality that is comparable to some forms of Mass Spectrometry. 1 By carefully tracking molecules as they pass across the length of the 512 pixel detector, their paths can be re-constructed and extrapolated back to a single injection point, "the vertex", no matter their size. Noise (thermal, electrical etc.) does not intercept the Vertex and is discarded.

The Perfect Solution for a Wide Range of Applications The superior performance of HPCE technology makes it the perfect technique for a wide range of applications. From complex lysates and large proteins to peptides and viruses, HPCE can revolutionise your analysis. Here we describe a little more from just two of the many applications. Monoclonal Antibodies (mabs) Analysis To assess the bioactivity and safety of recombinant monoclonal antibodies (mabs) as biological drugs, it is important to fully characterise them. Not only is this information crucial for the assessment of the suitability of a potential biopharmaceutical product, it is also important for the optimisation and QA/QC of the manufacturing process, storage conditions and life-time assessment of the drug at the site of use. Capillary Zone Electrophoresis HPCE-5 2 Revolutionised Applications Post-translational modification analysis by charge heterogeneity a monoclonal antibody The differences in the profiles were assessed using a CZE protocol. Significant differences were observed between the control samples and the stressed samples at the temperature parameters tested. These changes could potentially lead to major differences in the efficacy of the drug product. Proteins & Antibodies In the analysis described below, HPCE analysis was successfully used on therapeutic monoclonal antibodies for the assessment of stability, fragmentation and charge heterogeneity. Quantifiable differences were observed in the samples before and after heat-stress. Excellent repeatability was also obtained with a peak area (non-reduced) Relative Standard Deviation (RSD) of 2.88% and a peak time RSD of 2.28%. Basic Main peak Acidic Amino Acids Simplified and Improved Workflows Capillary Gel Electrophoresis (CGE) mab samples from a stock supply were analysed on the HPCE-512 system. Under reducing conditions antibodies split into their main component parts of the two heavy and two light chains. For use in the patient the user has to be confident that the mab has a low level of degradation or fragmentation. Clear differences can be seen when the mab is forced degraded by elevated temperatures. The large number of extra peaks and the reduction of the light and heavy chain peaks can clearly be seen. The HPCE-512 software allows highly accurate quantification of each peak as it can resolve them due to the multipixel detection. Stored at 2-8 C Stored at 40 C Main peak DNA & RNA Peptides Capillary Electrophoresis Specifications HPCE-512 - The highest CE Specifications for: Resolution (CGE ~200Da, <10bp DNA) Viruses Light Heavy Light Heavy Sensitvity Repeatability (~1.0µg/ml protein - LoQ) (<4% RSD) Linear Dynamic Range (5 orders concentration, 4 in MW) Quantitation (<2% RSD for simple mixtures, 5% for complex Lysates) A monoclonal antibody analysed on the HPCE-512. Stock (left panel) and forced degraded (right panel) under reducing conditions. The software automatically finds each peak and calculates the area under it. This is tabulated so mab integrity and repeatability metrics can be easily seen. 4

Revolutionise your Laboratory Amino Acids Analysis for Growth Media Optimisation Software The formulation, optimisation and validation of media for bacterial and cell based expression systems need to have accurate, flexible and repeatable analytics. The uptake of specific amino acids is a major indicator of the efficiency of media in a range of applications. HPCE has excellent amino acid analysis capability that can be used to measure the uptake of amino acids in a cell culture allowing potential optimisation of the media to the expression system. As part of the bioprocess, optimisation and monitoring of the uptake of amino acids in bacterial and mammalian cell lines can potentially be used to increase productivity and quality of the expressed product. HPCE can be used to fully characterise relevant media and establish protocols to identify significant amino acids that will provide a fingerprint profile of the efficiency of the media and bioreactor conditions. This can then be used to optimise the efficiency of one particular protein production stream. It also allows analysis of carbohydrates and even vitamins. Potential contaminants can also be detected - either by indirect detection of lactate, or by use of other wavelengths. Improve Your Data Flexible Analysis As you would expect for an instrument designed to revolutionise laboratory practices and maximise sample throughput, the software has been constructed with the analyst in mind. Intuitive to use with a clear graphical interface, the HPCE-512 software can be picked up in no time. But the simplicity of the user interface of the HPCE-512 software belies the sophistication of the signal detection and subsequent data processing which power the HPCE-512 platform and enable it to produce superior analysis. The 512 pixel photodiode detector facilitates the collection of an unprecedented amount of data about molecules as they pass the detector and about the analytical and buffer conditions. Powerful signal processing algorithms then reconstruct the paths of the molecules and strip out unwanted noise maximising the signal-to-noise ratio, giving the analyst accurate and robust data in seconds. Simple reports and export options enable the analyst to process and store sample Information where he or she likes in a format to suit. Since the majority of amino acids have very little or no UV absorbance in the 200-300 nm spectral range, the HPCE-512 system utilises indirect UV measurements. This is achieved by deploying a background electrolyte (BGE) in the running buffer. The BGE typically used absorbs energy at 254nm thus, with the filter set at this wavelength, the capillary is totally opaque to the photodiode array. The separation of amino acids is achieved by capillary zone electrophoresis and the analytes displace the BGE allowing energy to be detected by the photodiode array. This method shows similar resolution and limit of detection to direct absorption techniques and can be used for a very wide variety of nonabsorbing analytes such as lactate, carbohydrates, acids, metals and other ionic species. Lactate Maltose Mannose Glucose 600 µg/ml Lactate 400 µg/ml Lactate 200 µg/ml Lactate Reduce Time and Costs Simplify Your Workflow The screen shot shows the P3EVA analysis software for the HPCE-512 system. Top left: Displays the carousel positions and vial content. Top central: Displays the workspace and method script. Top right : Displays the lift position indicator. Bottom right : Displays the lamp intensity across the 512-pixel photodiode array. Bottom central: Displays single pixel data of an antibody light and heavy chains from 4 different positions on the photodiode array. The time differences of the peaks at the different pixels show how the multipixel detection acquires data in both space (position) and time. Bottom left: Displays instrument status and experimental time. Service & Support HORIBA offers a range of flexible service packages to suit your needs. With experienced engineers around the country, and a focus on customer support, HORIBA is well-placed to deliver the level of service you would expect from a market-leading brand. Dedicated applications scientists at deltadot are also available to help where your needs are sample dependent. With wide experience of method development, sample handling and contract analysis, they re ideally suited to help you ensure that the HPCE-512 delivers its full potential in your laboratory! 5 6

Specifications Physical Characteristics Discover the Label-Free Platform from HORIBA Scientific Width Height Depth Weight 680 mm 398 mm 735 mm < 70 kg Sample Handling Electrical Requirements Maximum capillary voltage (bipolar) The system includes two carousels: - an input carousel and an output carousel. Analyses can be run either way. The number of tube positions is 24 per carousel. Sample injection can be electrokinetic or hydrodynamic. Temperature control is by Peltier cell cooling. 28 kv (-14 kv to +14 kv) Filter wavelength range Voltage requirements Power requirements 200 300 nm 85 to 264 VAC 50/60 Hz < 750 Watts total Operating Requirements Temperature Humidity Optional Extras Sample Cooling Sample Analysis & Application Support We are always willing to arrange for analysis of your samples to demonstrate the superior data produced by the HPCE-512. Please contact us for more information. HORIBA UK Limited 14 C to 30 C 0 to 90% Non-condensing Between 10 C and 40 C 2 Dalston Gardens, Stanmore, Middlesex, HA7 1BQ United Kingdom Tel 020 8204 8142 Fax 020 8204 6142 E-Mail info-sci.uk@horiba.com Follow Us www.horiba.com/uk/scientific This document is not contractually binding under any circumstances - Printed in England - HORIBA UK 2016