ARE YOU LOOKING FOR 1-D OR 2-D HIGH RESOLOTION GEL ELECTROPHORESIS SYSTEM, WE HAVE A SOLUTION

Similar documents
Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

Proteomics. Proteomics is the study of all proteins within organism. Challenges

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

Lecture 8: Affinity Chromatography-III

Proteomics and Cancer

Advances in analytical biochemistry and systems biology: Proteomics

Protein Techniques 1 APPENDIX TO CHAPTER 5

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Proteomics. Areas of Application for Proteomics. Most Commonly Used Proteomics Techniques: Limitations: Examples

Laboratory Water Quality Affects Protein Separation by 2D Gel Electrophoresis

Exam MOL3007 Functional Genomics

Code Description Molecular Weight Separation Range

Proteomics. Areas of Application for Proteomics Most Commonly Used Proteomics Techniques: Limitations: Examples

Wearing gloves is highly recommended when handling the kit contents.

MOSAIQUES DIAGNOSTICS

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open!

Increasing Sensitivity In LC-MS. Simplification and prefractionation of complex protein samples

Laboratory Reagents and Raw Materials for Production.

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Quantitative mass spec based proteomics

Manipulating DNA. Nucleic acids are chemically different from other macromolecules such as proteins and carbohydrates.

Protein Microarrays?

ENDEXT TM Technology. Wheat Germ Premium Expression Kit. Ver 1.7. CellFree Sciences Co., Ltd.

ExcelGel 2-D Homogeneous Instructions

Typical probes. Slides per pack Aminosilane. Long oligo- Slide AStar None D surface. nucleotides

Pre-Lab: Molecular Biology

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

Antibody Analysis by ESI-TOF LC/MS

Lecture 13: Analysis of 2D gels

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

NPTEL

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Kinetics Review. Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets)

Fluorescent Difference Gel Electrophoresis

Determination of Isoelectric Point (pi) By Whole-Column Detection cief

PureSpin DNA Clean Up Kit

GE Healthcare. 2-D Electrophoresis. Principles and Methods

CaptiveSpray nanobooster

Multiphor II Electrophoresis System

Proteomics. Manickam Sugumaran. Department of Biology University of Massachusetts Boston, MA 02125

Slibinskas et al. Slibinskas et al. Proteome Science 2013, 11:36

Application Note LCMS-87 Automated Acquisition and Analysis of Data for Monitoring Protein Conjugation by LC-MS Using BioPharma Compass

Peptide biomarkers as a way to determine meat authenticity

Technical Note Detection of post-immunoprecipitation proteins by Western blot using the Quick Western Kit IRDye 680RD

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Investigation of a Mammalian Cellular Model for Differential Protein Expression Analysis Using 1D PAGE and Cleavable ICAT Reagents

Molecular characterization, detection & quantitation of biological products Purin Charoensuksai, PhD

ReadyPrep Reduction-Alkylation Kit

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

LAB 6: Agarose Gel Electrophoresis of Restriction Digested Plasmid DNA

Microarray Industry Products

Understanding life WITH NEXT GENERATION PROTEOMICS SOLUTIONS

Electro refers to electron flow or current. Thus Electrophoresis is movement under electric current.

Strep-Tactin XT Spin Column

SDS PAGE. Reagents and Equipment. SERVA SDS PAGE Gels. Electrophoresis Buffers, Ready-to-Use. Reagents. Gel Media. SERVA Protein Standards

ARBRE-P4EU Consensus Protein Quality Guidelines for Biophysical and Biochemical Studies Minimal information to provide

Silencer Select Pre-designed sirna Silencer Select Validated sirna Silencer Select Custom Designed sirna Custom Select sirna

A Complete Mini-Vertical Electrophoresis System

Peptide libraries: applications, design options and considerations. Laura Geuss, PhD May 5, 2015, 2:00-3:00 pm EST

XactEdit Cas9 Nuclease with NLS User Manual

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

DNA-RNA EXTRACTION. Dr. Amira A. T. AL-Hosary Lecturer of infectious diseases, Faculty of Veterinary Medicine, Assiut University, Egypt

Spectrum Mill MS Proteomics Workbench. Comprehensive tools for MS proteomics

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

Urine DNA Isolation 96-Well Kit (Slurry Format) Product # 27100

electrophoresis tech Versatile Separation Capabilities of the PROTEAN i12 IEF System

mdi Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

HiPer Random Amplification of Polymorphic DNA (RAPD) Teaching Kit

TECHNICAL NOTE Phosphorylation Site Specific Aptamers for Cancer Biomarker Peptide Enrichment and Detection in Mass Spectrometry Based Proteomics

CUSTOM PEPTIDE SYNTHESIS AT BACHEM

PA 800 plus Catalog. Systems/Software

3M Purification Inc. Technical and Scientific Services Global Support for the Life Science Industry. Global Expertise delivered locally

Vetter Development Service

Surface Plasmon Resonance Systems

RNA Purification Kits

Vetter Development Service

4. The Second-dimensional SDS-PAGE (vertical) Protocol

Introduction to Protein Purification

The Peptide Mapping Games!

Criterion. Precast Gels. Advancing the art of precast gel electrophoresis

Protocol for DNA extraction from FFPE Samples

Speed Past the Twists and Turns in Protein Research

ENDEXT Technology. Instruction manual for protein synthesis. with wheat germ cell-free system

Nucleic Acid Electrophoresis APPLICATION GUIDE

EpiQuik Quantitative PCR Fast Kit Base Catalog # P-1029

Blot: a spot or stain, especially of ink on paper.

BIOTECHNOLOGY. Course Syllabus. Section A: Engineering Mathematics. Subject Code: BT. Course Structure. Engineering Mathematics. General Biotechnology

From Molecules To Medicine

BEST PRACTICES IN MOUSE TISSUE SAMPLE PREPARATION FOR RNA EXTRACTION WITH PRECELLYS EVOLUTION

SMART Digest Kit User Manual. Version 2

Plasma/Serum RNA/DNA Purification Mini Kit Product# 55200

Center for Mass Spectrometry and Proteomics Phone (612) (612)

Multidimensional LC MS for Proteomics Present and Future

Using Genetics for Species Identification

Metabolomics in Systems Biology

PCR Laboratory Exercise

Great Savings! FIRST SEMESTER SPECIALS SAVE ON: Africa s Genomics Company. New England BioLabs (NEB) DNA & Protein Ladders

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Transcription:

ARE YOU LOOKING FOR 1-D OR 2-D HIGH RESOLOTION GEL ELECTROPHORESIS SYSTEM, WE HAVE A SOLUTION We are pleased to inform that Unigenetics Instruments Pvt. Ltd. now is a distributors of WITA GmbH, Germany in India. The Wittman Institute of Technology and analysis of Biomolecules ( WITA ) is dedicated to Products and Services for the Protein analysis. WITA s customers are Universities, Top Level Research Institutes, Biotech and Pharmaceutical companies around the world. WITA s specialty is the High resolution two dimentioanal Gel electrophoresis using NEPHGE ( Non Eqilibrium PH Gradient Electrophoresis)technology. Following are the Products and services from WITA For more information please visit : www.wita.de 2-DE is the most potent methods of analyzing the complete proteome of cells, cell lines, organs and tissues in proteomic studies. The advances in Proteomics have been possible through the development of advanced high resolution WITA VISION 2-DE systems allowing resolution up to 10000 protein spots of entire cell lysates in combination with protein identification by new highly sensitive mass spectrometric techniques. The knowledge of the human genome and its polymorphisms is the basis for an understanding of the gene functions in cellular processes. However, the data of the genes describe only the static state of the inherited information. To understand the dynamic processes within the cells, e.g. during cell differentiation and regulation or during disease development, it is mandatory to study the proteins involved. Their presence, actual concentrations, and possible modifications must be known in order to gain clues about their functional activities. This means that entire protein extracts of cells or expression pattern of the proteins, among them stress, alterations in temperature, different growth conditions, and the effects of various treatments. The analysis of malfunctioning cellular processes would allow the identification of biomarkers useful for the design of drugs to targets under specific disease situations. Furthermore, the individual genotypic differences of proteins, such as enzymes, under drug application cause differences in the tolerance against certain drugs. As they may be of therapeutic

use for some of the patients and toxic or inefficient for others, individualized therapies can be evaluated through proteomics. WITA is a corporation, having their Head office in Germany Teltow. Wita has a following products and all are associated to the analysis of Proteins. 1. ) 1 D Gel Electrophoresis system 2. 2-D Gel Electrophoresis system 3.) Services in 2-DE and individual Protein Analysis.

WITA s 1-DE GEL ELECTROPHORESIS SYSTEM : Advantages of WITA VISION 1-DE chamber Processing of 10 simultaneous 1-D gels Security cover with electric protection Storage of processed and re-buffered 1-D gels on the gel transfer modules at 80 degree C 1st dimension:iso-electric Focusing (NEPHGE technique) using proprietary ampholines (WITAlyte) ph 2 11 Gel casting using WITA s Gel Casting stand is very simple In Other Systems 2000 to 3000 ml of electrode solution is required where as in WITA s system only 400 ml electrode solution is required. WITA system can be used with SGT ( 11 cms ) LGT ( 20-25 cms ) and GGT ( 45 cms ) tubing Gels to reach higher resolution and more areas of applications.

WITA VISION 2-DE GEL ELECTROPHORESIS SYSTEM 225 for 2 nd dimension LGT gels 24 x 30 cm in size : Advantages of WITA VISION 2-DE chamber modular construction: processing of up to 5, 2-D gels per Penta pack individually but simultaneously reduction of buffer consumption to less than 0.6 L per gel reduction of running time to 3.5 h per gel simple handling: gels are casted in the 2-D chamber and remain manually untouched up to the end of electrophoresis 2nd dimension: 15 % SDS PAGE large size (LGT) 24 x 30 cm, up to 5.000 spots The cooling system is integrated into the apparatus WITA 2-DE system is compatible with 1 st dimension IPG strip system

WITA VISION 2-DE GEL ELECTROPHORESIS SYSTEM 410 for 2 nd dimension GGT gels 41 x 30 cm in size : (note: the green ruler is appr. 31 cm in length) see GGT 2 nd dim. Gel of this chamber 3-10 pi 100 kda 10

Advantages of WITA VISION 2-DE chamber modular construction: processing of up to 5 2-D gels per Pentapack individually but simultaneously reduction of buffer consumption to less than 1.0 L per gel reduction of running time to 6 h per gel simple handling: gels are casted within the 2-D chamber and remain manually untouched up to the end of electrophoresis 2nd dimension: 15 % SDS PAGE giant size (GGT) 41 x 30 cm, up to 10.000 spots The cooling system is integrated into the apparatus WITA 2-DE system is compatible with 1 st dimension IPG strip system

COMPARISION OF WITA S NEPHGE TECHNOLOGY WITH IPG WITA uses a NEPHGE (Non Equilibrium PH Gradient Technology for the Gel Electrophoresis) which gives certain advantages over the IPG technology. WITA Separation based on NEPHGE Technology Separation by IPG Technology NEPHGE 1st dimension separation according to IP of proteins. Separation gradient within the gel is forming by soluble ampholyte during electrophoresis. IPG 1st dimension separation according to IP of proteins. Fixed ph-gradients on pre-casted paper strips. NEPHGE 1st dimension separation standard sizes 24 and 41 cm. Larger sizes are possible in principle. IPG In the 1st dimension due to physical limitations no separation above 24 cm in length is possible.

NEPHGE NO endpoint method. 1st dimension electrophoresis is terminated BEFORE proteins reach their IP and point of minimal solubility: Proteins stay in solution, ready to enter 2nd dimension gel. IPG Endpoint method. 1st dimension electrophoresis is terminated AFTER proteins reached their IP and point of minimal solubility: Many proteins precipitate; substantial losses of proteins from 1st to 2nd dimension of gel. NEPHGE No limitations for DIGE 2-DE IPG No limitations for DIGE 2-DE NEPHGE standardized gel sizes 24 x 30 cm and 41 X 30 cm IPG maximal gel size 24 x 18 cm commercially available In combination with the WITA VISION 2 nd dimension apparatus gel size of 24 x 30 cm possible NEPHGE up to 10.000 individual spots per gel, suitable for MS identification of selected proteins IPG No more than 2.000 spots per gel.

SERVICES AVAILABLE FROM WITA FOR A CUSTOMER PROJECT : WITA Customers satisfaction is our business High resolution NEPHGE 2-dimensional gel electrophoresis (acc. Prof. Klose) Giant gels up to 41 x 30 cm; up to 10.000 individual protein spots Service in proteomic projects of any size from sample preparation to identified proteins Peptide and Protein analytical Service Separation, Identification, Modifications, Purity etc. MALDI-TOF, ESI-MS/MS, Edman sequencing, HPLC, Amino Acid Analysis Peptide synthesis Tricky peptides: Unusual, long, hydrophobic peptides Unnatural amino acids, Seleno-aa, isotope labelling, dye labelling Cyclization, Modifications, -S-S-bridges a. s. o. DNA/RNA Analysis MS analytic of oligonucleotides De novo sequencing of short oligonucleotides (5 100 nts) Compound analysis analysis of complex natural compounds mixtures, like herb extracts and animal body fluids about proteins/peptides, nucleic acids and selected ingredients 2-DE, MS, de novo sequencing, HPLC, ultra filtration WITA S team of scientists and well trained technician take a special care in understanding the requirement of the project and assist in completion of the same in minimal cost.

We are looking for an opportunity to serve.please let us know if you have any requirement regarding the same. Our contacts are : DELHI : ( Registered & Head Office) Unigenetics Instruments Pvt. Ltd. 153, Pocket-5, Mayur Vihar, Phase-1 Delhi-110091, India Ph : 0091-11-22757221 Fax : 0091-11-22757226 CALCUTTA : Mr. Tanmoy Mitra Mob : 0-94330-85262 E Mail : tanmoy.mitra@unigenetics.net BANGALORE : Mr. N. Shankar Narayan Mob : 0-98451-25857 E Mail : kumba_123@hotmail.com