Installation Instructions

Similar documents
FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

Simpson Dura-Vent Engineered Excellence

Simpson Dura-Vent Engineered Excellence

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.

How to choose the best furnace?

Z-Vent Model SVE Series III

Installation Instructions

SI T T FST

Installation and Maintenance Instructions

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

NFPA STANDARDS DEVELOPMENT SITE

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

Installation and Maintenance Instructions For. Installation and Maintenance Instructions For

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Tek Spec 4.0. Reference Guide

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

DuraFlex AL. Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

the heart of a warm home

PIPE

Questar ThermWise Duct Technical Specifications

RECONSTRUCTION AND REPLACEMENT OF EARTHQUAKE DAMAGED MASONRY CHIMNEYS

Modern Rumford. MR 48 fireplaces

Isokern MAGNUM Fireplace and DM Chimney System

O B R O U N D G R E A S E D U C T

Residential Building Inspections

Description/Application Maximum Temperature Continuous Firing Maximum Temperature Intermittent Firing Fuel Construction Diameters: Insulation

Administrative Changes

KAZAN: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 6 4. OPERATION TESTING 11. Keep for future use

OWNER`S MANUAL 1100 MODEL STOVE

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

Wood & Pellet ECONOMIZER BIOMASS PRODUCTS

Ecoteck Amalfi Freestanding. Wood Pellet Burning Heater

Installation Instructions. Air-Cooled Chimney for Isokern Fireplaces

ARGOS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

PHAROS: MODEL SPECIFICATIONS 1. TECHNICAL DATA 2. PRE-INSTALLATION 3. INSTALLATION 4. OPERATION 5. TESTING. Keep for future use

Installation instruction

STANDARD PLAN BULLETIN SP-2 (Structural)

Fireplace. Opening. Old. Opening up an old fireplace is like striking gold in your very own home.

Owner's Manual Residential Factory Built Fireplace. Operation Maintenance Installation FOCUS 250

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

Installation Manual Installation and Fireplace Setup

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues

A. Source Limitations: Obtain each type of building insulation through one source.

Installation instructions

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex

De Montfort Mark 7 Incinerator (Flatpack)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Masonry Firebox. Models MM33, MM39, MM44, MM49 and MM63

This wood burning fireplace complies with UL127 standard as a FACTORY BUILT APPLIANCE.

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

APPENDIX "B" November 5, 2002 Page 1 of 6 BOILERSMITH LTD. STACKS AND BREECHING

Building Codes and Ordinances ARC 227

Rediflow Concrete Gas Flue System

IMPERIAL. Matte Black Stove Pipe. ECCO is proud to be a member of: REV. W-4

MODEL IPIC SERIES 4G GREASE DUCT

Installation Manual Installation and Fireplace Setup

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

GCI60 Hampton Cast Iron Pellet Insert

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Tested to BS EN and BS EN 1443

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

CONSTRUCTION CODE PERMIT INFORMATION

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction

Nouveau BBQ Single Flue

Stove & Fireplace. Maintenance Products

This Listed Top Vented Gas Log Enclosure is designed for use with Decorative Natural Gas or Propane (LP) Gas Appliances, only.

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Fireplace Setup

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner. Installation Instructions. Models

IMPERIAL MATTE BLACK STOVE PIPE

SECTION PRE-ENGINEERED BUILDING INSULATION

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Concentric Vent/Air System Supplement

IMPERIAL MATTE BLACK STOVE PIPE

SECTION 07530CP EPDM MEMBRANE ROOFING

Chapter 2: Foundation

Hardin County Planning and Development Commission

Installation and Operation Instructions Stone Age Indoor Fireplace

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Kiva Fireplace GAS BURNING INSTALLATION MANUAL

SECTION HVAC INSULATION

SECTION HVAC DUCTS AND CASINGS

Design & Construction Standards, Revised January

Wood Burning Fireplace

Advanced Ventilation for Residential applications FBC Res 2010.

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

Transcription:

Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. SAFETY NOTICES When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building, fire officials, or authority having jurisdiction about restrictions, permit and installation inspection requirements in your area.. DO NOT INSTALL IN A MOBILE HOME;. DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS;. DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE;. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL;. HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITUTE AWAY. CONTACT MAY CAUSE SKIN BURNS. Tulikivi Group, FI-83900 JUUKA, Finland tel. +358 207 636 000 fax +358 207 636 120 1

INSTALLATION BEFORE INSTALLATION After unpacking, check that all parts are included. Complete list of parts can be found in construction drawings. One of the main necessary precautions when installing a room heater is to leave sufficient space between the heater (top, sides, back, front, and under chimney connector) and any other material that can catch fire. FLOOR PROTECTOR If the heater is to be installed on a combustible floor, it must be placed on a 3 (75mm) thick pad of foamglass + 1 /2 (12mm) cement board, see TTM 1.2 for details. A floor protector consisting of a layer on non-combustible material at least 3 /8 (9mm) thick is required to cover the area extending 16 (400mm) in USA / 18 (450mm) in Canada to the front and 8 (200mm) to the sides and back from the heater body. (See fig. 1) 8 200mm (USA)* (CAN)* (*)= If possible dependent on the clearance to combustibles. See TTM 1.2 for details 8 (USA)* 200mm (CAN)* room heater 8 (USA)* 200mm (CAN)* Min 3 / 8 (9mm) non combustible floor protector. 8 8 16 450mm (USA)* (CAN)* (fig. 1) In a rear vent installation the floor protection must also extend under the chimney connector a minimum of 2 (50mm) beyond either side of the pipe. 2

INSTALLATION CLEARANCES TO COMBUSTIBLES It is extremely important that you respect required installation distances and that you respect local installation regulations. This is for your safety! The manufacturer is not responsible for the product, if it is not installed following these recommendations. These clearances may only be reduced by means approved by the regulatory authority. See TTM 1.2 for instructions about using the heat shield. A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.) These surfaces are not limited to those that are visible and also include materials that are behind non-combustible materials. If you are not sure of the combustible nature of a material, consult your local fire officials. Backwall B Heat Shield Sidewall A C Installation clearances to combustibles Unit distance to sidewall (A) 14 / 350mm Unit distance to backwall (B) 20 / 500mm Unit distance to ceiling 10 / 250mm Unit distance to sidewall with heat shield (C) (see TTM 1.2 manual) 3 / 75mm Unit distance to backwall with heat shield (see TTM 1.2 manual) 3 / 75mm 3

CHIMNEY CONNECTOR The chimney connector is a single walled pipe used to connect the room heater to the chimney. For use with the appliance the chimney connector MUST be 6-8 in diameter, with a minimum thickness of 24 gauge black, blued or stainless steel. Aluminium and galvanized steel pipe is not acceptable for use with the appliance. These materials cannot withstand the extreme temperatures of a wood fire and can give off toxic fumes when heated. Do not use the connector pipe as a chimney. Each chimney connector section must be installed to the stove flue collar and to each other with the male (crimped) end toward the stove. See fig 2. Connector towards stove flue gas direction Fig. 2 This prevents any amount of condensed or liquid creosote from running down the outside of the pipe or the stovetop. All joints, including the flue collar connection must be secured with three sheet metal screws to ensure that the sections do not separate. For the best performance the chimney connector should be as short and direct as possible. See TTM 1.2 manual for details about Tulikivi chimney connector. No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a floor ceiling. All sections of the chimney connectors must be accessible for cleaning. Where passage through a wall or partition of combustible construction is desired, the installation must conform with NFPA 211 or CAN/CSAB365, (also addressed in this manual) or TTM 1.2 manual (Tulikivi chimney connectors). 4

CHIMNEY DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. This room heater must be connected to 1) A chimney complying with the requirements for Type HT chimneys in the standard for Factory-Built s for Residential Type and Building Heating Appliances, UL 103, (USA) (ULC S629 in Canada) or 2) A code-approved masonry chimney with a flue liner. The chimney diameter must be at least 6 (150mm) or egual, and the overall height of the chimney measured from the floor on which the heater is installed, must be at least 15ft (4,5m) ans 20ft (6,0m) for bakeoven models. FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the manufacturer s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and T section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. See page 8 for chimney termination requirements. Listed Cap Listed Storm Collar Maintain 2 Clearance Listed Flashing Attic Insulation Shield Combustible Ceiling Joists Specified Clearance Connector Ceiling Support Connector * * Refer to Clearances to Combustibles 5

MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. Refer to Combustible Wall Connector Pass- Throughs on page 8. See TTM 1.2 for use of foamglass Concrete Cap Fireclay Flue Liner with Airspace 1 Clearance with Fire Stop Flashing Combustible Wall 1 Clearance Thimble-12 inches of brick Sheathing * Airtight Cleanout Door * Refer to Clearances to Combustibles 6

MASONRY FIREPLACE There are listed kits available to connect a stove to a masonry fireplace. The kit is an adapter that is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation. Support Plate & Clamp Listed Rigid Stainless Liner Fireclay Liner 5/ 8 (16mm) Minimum or Equivalent. Carry Stovepipe Above the Liner Stainless Steel Flex Section Damper Plate is Removed or Fastened in Open Position Use Damper Adapter or Seal with Sheetmetal and Sealant Stainless Tee with Cleanout Stainless Connector Pipe Cleanout CHIMNEY HEIGHT A masonry chimney or a listed factory-build chimney must be the required height above the roof and any other nearby obstructions. The chimney must be at least 3 (90 cm) higher than the highest point where it passes through the roof and at least 2 (60 cm) higher than the highest part of the roof or structure that is within 10 (305 cm) of the chimney, measured horizontally. 3 90cm 2 60cm 10 305cm 7

Here are four methods of combustible wall chimney connector pass-throughs. This information was provided from NFPA 211. METHOD A. 12 (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5 (89 mm) brick and a 5/8 (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent. Keep a minimum of 12 (304.8 mm) of brick masonry between the clay liner and wall combustibles. The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney flue liner but not past the inner surface. Firmly grout or cement the clay liner in place to the chimney flue liner. A Minimum 12 (304.8mm) to combustibles Minimum chimney clearance to brick and combustibles 2 (50.8mm) Flue Masonry chimney Minimum clearance 12 (304.8mm) of brick connector Fire clay liner METHOD B. 9 (228.6 mm) Clearance to Combustible Wall Member: Using a 6 (152.4 mm) inside diameter, listed, factory-built Solid-Pak chimney section with insulation of 1 (25.4 mm) or more, build a wall passthrough with a minimum 9 (228.6 mm) air space between the outer wall of the chimney length and wall combustibles. Use sheet metal supports fastened securely to wall surfaces on all sides, to maintain the 9 (228.6 mm) air space. When fastening supports to chimney length, do not penetrate the chimney liner (the inside wall of the Solid-Pak chimney). The inner end of the Solid-Pak chimney section shall be flush with the inside of the masonry chimney flue, and sealed with a non-water soluble refractory cement. Use this cement to also seal to the brick masonry penetration. B Nonsoluble refractory cement length flush with inside of flue Factory-built chimney length Min. air space 9 (228.6mm) Flue Masonry chimney Minimum chimney clearance from masonry to sheet steel supports and combustibles 2 (50.8mm) Air space Sheet steel supports Minimum clearance 9 (228.6mm) connector Use chimney mfrs. parts to attach connector securely Solid-insulated listed factory-built chimney length METHOD C. 6 (152.4 mm) Clearance to Combustible Wall Member: Starting with a minimum 24 gage (.024 [.61 mm]) 6 (152.4 mm) metal chimney connector, and a minimum 24 gage ventilated wall thimble which has two air channels of 1 (25.4 mm) each, construct a wall pass-through. There shall be a minimum 6 (152.4) mm separation area containing fiberglass insulation, from the outer surface of the wall thimble to wall combustibles. Support the wall thimble, and cover its opening with a 24- gage minimum sheet metal support. Maintain the 6 (152.4 mm) space. There should also be a support sized to fit and hold the metal chimney connector. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner. C Two ventilated air channels each 1 (25.4mm). Construction of sheet steel. Flue Masonry chimney Minimum chimney clearance to sheet steel supports and combustibles 2 (50.8mm) Sheet steel supports Two air channels each 1 (25.4mm) connector Minimum 6 (152.4mm) glass fiber insulation METHOD D. 2 (50.8 mm) Clearance to Combustible Wall Member: Start with a solid-pak listed factory built chimney section at least 12 (304 mm) long, with insulation of 1 (25.4 mm) or more, and an inside diameter of 8 (2 inches [51 mm] larger than the 6 [152.4 mm] chimney connector). Use this as a pass-through for a minimum 24-gage single wall steel chimney connector. Keep solid-pak section concentric with and spaced 1 (25.4 mm) off the chimney connector by way of sheet metal support plates at both ends of chimney section. Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure chimney flue liner. D Sheet steel supports Air space 2 (50.8mm) section Masonry chimney Minimum chimney clearance to sheet steel supports and combustibles 2 (50.8mm) Minimum clearance 2 (50.8mm) 1 (25.4mm) air space to chimney length Sheet steel supports connector length NOTES: 1. Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through system and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. 8