SunWave Prismatic Skylights

Similar documents
SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

RS24-10 Single-Section Skylight System

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

Commercial Dynamic Dome Unit Skylight - Guide Specification

ATI Evaluation Service A Division of Architectural Testing Certification Services

Kingspan Day-Lite Kapture Data Sheet

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

HIGH-PERFORMANCE PRISMATIC DAYLIGHTING

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

RS32 Multi-Section Skylight System under/over seam clip double diverter

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION SPECIAL FUNCTION GLAZING

WESTECK WINDOWS and DOORS

CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

SECTION 07530CP EPDM MEMBRANE ROOFING

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

SECTION ROOF SPECIALTIES

Corium Brick Rainscreen System Specifications

Custom Daylighting Structures

VINYL SINGLE HUNG WINDOW

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Alply CLASSIC WALL Architectural Insulated Panel Wall System

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

Series 510-I Thermal Heavy Commercial Projected Window

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

YEARS SINCE Firestone UltraPly TM TPO Membranes EXPERIENCE THE ULTIMATE IN COOL ROOFING TECHNOLOGY.

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Picture/Radius Windows Montecito New Construction Window

STORAGE AND TRANSPORTION

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

SuperWallTM. Curtainwall - Window Wall

SECTION METAL ROOF PANELS

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

The Alternative to Storefront. Gerkin Model 58F

Quality. Care. Commitment. series 8000 doors supreme quality

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION Solar Control Film WINDOW FILM. Copyright ARCAT, Inc. - All rights reserved

Firestone Polyiso Boards

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

SWING DOOR SPECIFICATION

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Casement Windows Montecito New Construction Window

ICD High Performance Coatings. Contractor Manual

Series Heavy Commercial Projected Window

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

CS-100 Guide Specifications

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

SECTION IMPACT RESISTANT WALL PROTECTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

CODE COMPLIANT or NOT CODE COMPLIANT. that is the question

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION TUBULAR DAYLIGHTING DEVICE. Display hidden notes to specifier. (Don't know how? Click Here)

HIGH PERFORMANCE PRISMATIC SKYLIGHTS. Nucor Daylighting

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

Specifications for FL-100 Soffit Panel

Awning Windows Montecito New Construction Window

LP SmartSide Perfection Shingle

Veka Evolutions Commercial Window Program

HomeMaker3 Windows and Doors

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

7520 Casement Windows

Model 8000 Double Hung H-C x 2311 (56 x 91 )

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

6110 Horizontal Sliding Windows

TOPCOAT System Specifications Corrugated Transite Panels

GUIDE SPECIFICATION: DUCT LINER

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

MikronWood Thermal Advantage Composite Window System Ideal for new construction and replacement applications in colder temperature climates

OPTIWIN MOTURA. Technical Description. Synopsis:

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

TMS 114 XT TECHNICAL MANUAL

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

Transcription:

Item Description Fixed Skylights Product Information SunWave Prismatic Skylight Options: Class 1 Units offers Acrylic outer lens options in a single*, double, and triple* glazed configuration. 100% Impact Modified 0.165" Acrylic outer lens for single glazed units; and subsequent 50% Impact Modified 0.120" interior lenses for double and triple glazed units. Single glazed units are intended for unconditioned space Class 1 domes are hail rated up to 1.25". Class 3 Units offers Acrylic outer lens options in a single*, double, and triple* glazed configuration 100% Impact Modified 0.181" Acrylic outer lens for single glazed units; and subsequent 50% Impact Modified 0.120" interior lenses for double and triple glazed units. Single glazed units are intended for unconditioned space Class 3 domes are hail rated up to 1.75". Factory Mutual (FM) Approved Units offer Polycarbonate outer lens options in a single* and double glazed. 0.165" Polycarbonate outer lens for single glazed units; 0.125" inside lens for double glazed units; and subsequent interior lenses for triple glazed units that are non-fm rated Polycarbonate units. Single glazed units are intended for unconditioned space FM Approved (Class 4) units are hail rated up to 2". High Velocity Hurricane Zone (HVHZ) units offer a Polycarbonate outer lens option in a double-glazed configuration. 0.230" Polycarbonate outer lens and a 50% Impact Modified 0.120" Acrylic inside lens. HVHZ Prismatic Series (Class 4) units are hail rated up to 2". *Single and Triple glazed units may not be available in all styles or sizes. Please consult with your Firestone Sales Representative for more information on this products availability. Selection Information**: The following information is provided to determine the appropriate SunWave Skylights to be used. * Class 1 & Class 3: Rated Design Pressure: 35 psf Factory Mutual (FM) and High Velocity Hurricane Zone (HVHZ) series: Rated Design Pressure: 60 psf Upon review of Pre-Installation Notice (PIN), additional wind speed coverage may be available. The use of FM and HVHZ SunWave Units may be required. Contact your regional Building Systems Advisor for more information. *It is the responsibility of the designer/building owner to determine the appropriate product(s) to be used for the specific project and related conditions. **Improper use of product may void warranty coverage. Page 1 of 9

Method of Application: Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, and grease. Install in accordance with current Firestone specifications, details, and workmanship requirements. Fasten the SunWave Prismatic Skylights with the included #12 x 1½" (38 mm) 300 series stainless steel screws with neoprene/stainless steel bonded washers. Storage: Store products in manufacturer s unopened packaging until ready for installation. Store materials in a dry area, protected from freezing, staining, contamination or damage. Precautions: To provide fall protection, a Safety-Security Guard (SSG) Screen is integrated into all SunWave curbs; see SunWave Roof Curb TIS #1802. Installer shall be responsible for fall protection when SunWave curbs are not used. SunWave Prismatic Skylight Systems not for use in harsh, corrosive, marine and high-humidity environmental conditions such as marina, greenhouses, petrochemical facilities or other chemicals where Skylights may be exposed to such conditions. Skylights should not be installed in locations with operating temperatures in excess of -75 F (-59 C) or 180 F (82 C). Cleaning Acrylic Lenses: Frequency of cleaning is determined by site conditions. When cleaning acrylic lenses, use only water or water with a mild soap. Use a soft rag to minimize scratching the acrylic. A pressure washer is acceptable to use as well. Never use ammonia, aromatic or petroleum based products to clean acrylic lenses. This will cause deterioration and cracking of the lens and will void the warranty. LEED Information: Post Consumer Recycled Content: 50% Pre-Consumer Recycled Content: 25% Manufacturing Location: Conyers, GA; Sacramento, CA *NOTE: LEED is a registered trademark of the U.S. Green Building Council. Compliance Information: High Velocity Hurricane Zone Approved FBP-1650 National Fenestration Rating Council (NFRC) Florida Building Code: FL #14199 Tested in accordance to AAMA/WDMA/CSA101/I.S.2/A440-08: North American Fenestration Standard/Specification for windows, doors, and skylights. FM Approved Skylights shall be glazed using CLEAR ARMOR Clear Polycarbonate Prismatic over CLEAR ARMOUR High White Polycarbonate Prismatic lens, Class A Rated, FM Approved. FM Approved Skylights shall be tested and approved under Factory Mutual #4431 testing method for fixed skylights. Class A flame rating. Page 2 of 9

AAMA Tested Standard size units up to 5080 are tested and certified to AAMA/WDMA/CSA101/I.S.2/A440 to comply with 800MD frame section 2405.5 of the International Building Code. Florida Building Code Test Protocols for HVHZ protocol TAS 201, TAS 202 and TAS 203 applies to High Velocity Hurricane Zone skylights. The samples tested met the performance requirements set forth in the protocols for a ±60.0 psf design pressure rating. Size units up to 5080 with 800 MD frame are tested and listed for HVHZ. OSHA Regulation Section 1926.502(i)(2) applies to skylight covers being placed in the openings in a roof at the time of installation. This regulation states All [other] covers shall be capable of supporting, without failure, at least twice the weight of employees, equipment, and materials that may be imposed on the cover at any one time. An independent thirdparty testing laboratory performed a 400 pound drop test on a SunWave unit which resulted in no damage after impact and five minutes of continued exposure. Therefore, when properly installed on a building architecturally designed for, and supportive of skylights, SunWave Prismatic Skylights are considered compliant with this OSHA requirement. NOTE: No plastic skylight of any kind is immune to degradation over time and any skylight would be unlikely to continue to meet the OSHA 1926.502 requirements after having been exposed to 10 to 20 years of UV radiation. It is imperative building owners, contractors, designers, and architects comply with OSHA section 1910.23(a)(4) and install an appropriate guard or screen to prevent injuries to third parties. Compliance Information Continued: OSHA Section 1910.23(a)(4) establishes the requirements for all skylight roof openings. This regulation states, "Every skylight floor opening and hole shall be guarded by a standard skylight screen or a fixed standard railing on all exposed sides. To ensure that our products comply with this OSHA regulation, all Firestone SunWave Curbs include standard integrated fall protection screens. These screens come factory-installed in our curbs, ensuring that all our curb installations meet the regulation. Therefore, when properly installed to a building architecturally designed for, and supportive of skylights, SunWave Prismatic Skylights are considered compliant with this OSHA requirement. However, please note that Firestone Building Products Company, LLC is not responsible for the installation or architectural designs required for proper use of Firestone SunWave products. Use of a certified installer and consultation with an architect before using Firestone SunWave products is advised. Distribution of Hail Sizes 1990-2010 Range Size (Inches) Number of Events Percentage Total Percentage Cumulative 0.75" 316 0.14% 0.14% 0.75 1" 110,104 49.50% 49.64% 1" 2" 101,048 45.43% 95.06% 2" 3" 9,185 4.13% 99.19% 3" 4" 841 0.38% 99.57% 4" to 8" 952 0.43% 100% Source: CDS business Mapping, LLC Daniel Munson and Gloria Molina Page 3 of 9

Average Severe Hail Days Per Year Page 4 of 9

Design Specification: CLEAR PRISMATIC OVER HIGH WHITE PRISMATIC CONTINUOUS SEAL ALL SIDES, APPLIED WET DURING MFG. #12 X 1 1/2 (38 mm) 300 SERIES STAINLESS STEEL SCREWS WITH RUBBER WASHER WEEP SLOT (ONE PER SIDE) INSULATED THERM BREAK FRAME (CLOSED CELL FOAM INSULATION) EXTERIOR GRADE VINYL (WHITE) NO EXPOSED METAL TO THE INTERIOR #12 X 1 1/2 (38 mm) 300 SERIES STAINLESS STEEL SCREWS WITH RUBBER WASHER 1/2" (13 mm) VINYL WEATHER SWEEP 1 7/8" X 1/4" (48 X 6 mm) FOAM CURB SEAL (SUPPLIED BY FIRESTONE PRE-INSTALLED ON FRAME) (NO CAULKING REQUIRED) FIRESTONE 18" CURB FLASHING OR MEMBRANE FIRESTONE CURBS PER PROJECT SPECIFICATIONS Design Specification Notes: Skylights shall be fabricated from 6063 T6 aluminum, finish to be natural mill. Frames shall have integral condensation and weepage gutters which drain interior moisture to the outside. Corners shall be mitered and welded. Acrylic and polycarbonate glazing shall be separated from the skylight frame with a continuous seal. Skylight frames shall be glazed using 100% or 50%, impact modified prismatic acrylic or prismatic polycarbonate in a Prismatic Series Dome configuration. Multi-glazed units default to include Insulated Thermal Break, Curb Seal Tape, Weather Sweep, and screws. Single-glazed units default to not include Thermal Break, Curb Seal Tape, Weather Sweep, or screws. Page 5 of 9

Typical Properties SunWave Component Specification Description Class 1 Single Double Triple Dome Material Acrylic Acrylic Acrylic Acrylic Acrylic Acrylic Thickness 0.165" 0.165" 0.120" 0.165" 0.120".120" Impact Modification % 100% 100% 50% 100% 50% 50% Hail Rated (Class 1) 1.25" 1.25" 1.25" SHGC (Solar Heat Gain Coefficient).68.48.39 U-Value N/A.72.60 VLT (Visible Light Transmittance).74.68.62 Class 3 Single Double Triple Dome Material Acrylic Acrylic Acrylic Acrylic Acrylic Acrylic Thickness 0.181" 0.181" 0.120" 0.181" 0.120" 0.120" Impact Modification % 100% 100% 50% 100% 50% 50% Hail Rated (Class 3) 1.75" 1.75" 1.75" SHGC (Solar Heat Gain Coefficient).68.48.39 U-Value N/A.72.60 VLT (Visible Light Transmittance).74.68.63 Factory Mutual (FM) Approved (FM #4431) Single Double Triple Dome Material Polycarbonate Polycarbonate Polycarbonate N/A Thickness 0.165" 0.165" 0.125" N/A Impact Modification % N/A N/A N/A Hail Resistance (Class 4) 2.0" 2.0" N/A SHGC (Solar Heat Gain Coefficient).68.48 N/A U-Value N/A.72 N/A VLT (Visible Light Transmittance).70.64 N/A High Velocity Hurricane Zone (HVHZ) Single Double Triple Dome Material N/A Polycarbonate Acrylic N/A Thickness N/A 0.230 0.120 N/A Impact Modification (%) N/A N/A 50% N/A Hail Resistance (Class 4) N/A 2.0" N/A SHGC (Solar Heat Gain Coefficient) N/A.48 N/A U-Value N/A.72 N/A VLT (Visible Light Transmittance) N/A.65 N/A Page 6 of 9

Class 1 Prismatic Skylights: ID Frame Call-Out Model Width Length Single Double Triple 2020 27.25" 27.25" W56RACC122 2040 27.25" W56RACDL05 2080 27.25" 99.25" W56RACC128 20100 27.25" 123.25" W56RACC120 3030 39.25" 39.25" W56RACC133 3050 39.25" 63.25" W56RACDL88 3060 39.25" 75.25" Single and Triple glazed W56RACC136 3080 39.25" 99.25" units may not be available W56RACC138 30100 4040 4050 4060 4070 4080 39.25" 52.25" 123.25" 63.25" 75.25" 87.25" 100.25" in all styles or sizes. Please consult with your Firestone Sales Representative for more information on this products availability W56RACC130 W56RACDL06 W56RACC145 W56RACC146 W56RACC147 W56RACDL43 40100 52.25" 123.25" W56RACC140 5050 63.25" 63.25" W56RACDL07 5060 63.625" 75.625" W56RACDL08 5070 63.25" 87.25" W56RACC157 5080 63.25" 99.25" W56RACDL65 50100 63.25" 123.25" W56RACC150 Class 3 Prismatic Skylights: Single and Triple glazed units may not be available in all styles or sizes. Please consult with your Firestone Sales Representative for more information on this products availability ID Frame Call-Out Model Width Length Single Double Triple 2020 27.25" 27.25" W56RACC322 2040 27.25" W56RACDL44 2080 27.25" 99.25" W56RACC328 20100 27.25" 123.25" W56RACC320 3030 39.25" 39.25" W56RACC333 3050 39.25" 63.25" W56RACDL89 3060 3080 39.25" 39.25" 75.25" 99.25" Single and Triple glazed units may not be available W56RACC336 W56RACC338 30100 39.25" 123.25" W56RACC330 in all styles or sizes. Please 4040 W56RACDL45 consult with your Firestone 4050 63.25" W56RACC345 Sales Representative for 4060 75.25" W56RACC346 4070 87.25" more information on this W56RACC347 4080 52.25" 100.25" products availability W56RACDL46 40100 52.25" 123.25" W56RACC340 5050 63.25" 63.25" W56RACDL52 5060 63.625" 75.625" W56RACDL53 5070 63.25" 87.25" W56RACC357 5080 63.25" 99.25" W56RACDL64 50100 63.25" 123.25" W56RACC350 Single and Triple glazed units may not be available in all styles or sizes. Please consult with your Firestone Sales Representative for more information on this products availability Page 7 of 9

FM (Factory Mutual) Prismatic Skylights: ID Frame Call-Out Model Width Length Single Double Triple 2020 27.25" 27.25" Consult your Sales Representative for W56RACFM22 N/A 2040 27.25" more information on this products W56RACDL81 N/A 2080 27.25" 99.25" availability. W56RACFM28 N/A 20100 27.25" 123.25" N/A N/A N/A 3030 39.25" 39.25" Consult your Sales W56RACFM33 N/A 3050 39.25" 63.25" Representative for more W56RACFM35 N/A 3060 39.25" 75.25" information on this products W56RACFM36 N/A 3080 39.25" 99.25" availability. W56RACFM38 N/A 30100 39.25" 123.25" N/A N/A N/A 4040 W56RACDL82 N/A 4050 63.25" Consult your Sales W56RACFM45 N/A Representative for more 4060 75.25" W56RACFM46 N/A information on this products 4070 87.25" availability. W56RACFM47 N/A 4080 52.25" 100.25" W56RACDL83 N/A 40100 52.25" 123.25" N/A N/A N/A 5050 63.25" 63.25" Consult your Sales W56RACDL84 N/A 5060 63.625" 75.625" Representative for more W56RACDL85 N/A 5070 63.25" 87.25" information on this products W56RACFM57 N/A 5080 63.25" 99.25" availability. W56RACDL86 N/A 50100 63.25" 123.25" N/A N/A N/A HVHZ (High Velocity Hurricane Zone) Prismatic Skylights: ID Frame Call-Out Model Width Length Single Double Triple 2020 27.25" 27.25" N/A W56RACPC22 N/A 2040 27.25" N/A W56RACDL49 N/A 2080 27.25" 99.25" N/A W56RACPC28 N/A 20100 27.25" 123.25" N/A N/A N/A 3030 39.25" 39.25" N/A W56RACPC33 N/A 3050 39.25" 63.25" N/A W56RACDL90 N/A 3060 39.25" 75.25 N/A W56RACPC36 N/A 3080 39.25" 99.25" N/A W56RACPC38 N/A 30100 39.25" 123.25" N/A N/A N/A 4040 N/A W56RACDL50 N/A 4050 63.25" N/A W56RACPC45 N/A 4060 75.25" N/A W56RACPC46 N/A 4070 87.25" N/A W56RACPC47 N/A 4080 100.25" N/A W56RACDL51 N/A 40100 52.25" 123.25" N/A N/A N/A 5050 63.25" 63.25" N/A W56RACDL47 N/A 5060 63.625" 75.625" N/A W56RACDL48 N/A 5070 63.25" 87.25" N/A W56RACDL57 N/A 5080 63.25" 99.25" N/A W56RACDL66 N/A 50100 63.25" 123.25" N/A N/A N/A Page 8 of 9

Custom Ordering* Quantity Outside Curb Dimensions** Width: Length: Height: Class (Hail Rating) Options (Hail Rating) Class 1 (1.25") Class 3 (1.75") FM (2.0") HVHZ (2.0") Poly (2.0") Single Double Triple *Custom mold fee applies to Prismatic Skylights domes. **Custom Dome will be determined by curb dimensions. Please contact your Quality Building Services Technical Department at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. Page 9 of 9