Pre-qualification testing in accordance with NORSOK M-501, Rev. 3/4, System 7, suitable for splash zone. Property Test/Standard Description

Similar documents
vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Property Test/Standard Description

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Property Test/Standard Description

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. high gloss (85+) Flash point ISO 3679 Method 1 30 C. US EPA method 24 (tested)

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description

Date of issue: 5 October 2017 Page: 1/6

Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. Flash point ISO 3679 Method C

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 22 g/l

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

Technical Data Jotamastic 80 MIO

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

two component high build amine adduct cured phenolic epoxy primer

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

The Application Guide offers product details and recommended practices for the use of the product.

^(ValidationDate) AE - BH - DZ - EG - KW - LY - MA - OM - QA - SA - TR Jotashield Tex Ultra

TECHNICAL DATA SHEET

TECHNICAL DATA SHEET

The Application Guide offers product details and recommended practices for the use of the product.

The Application Guide offers product details and recommended practices for the use of the product.

Technical Data Sheet EPOXY PRIMER 3:1 Anti-corrosion epoxy primer RELATED PRODUCTS. Epoxy primer hardener EPOXY PRIMER HARDENER PROPERTIES

Normadur 65 HS. Technical Data PROPERTIES AND RECOMMENDED USAGE TECHNICAL DATA

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Measured in accordance with ASTM D 2697.

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Epobond RS-T30 and RS-T35

Corlar 2.8 HG High Solids Epoxy

Refer to Substrates & Surface Preparation.

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

APPLICATION GUIDELINES EXTERIOR DECK SYSTEM

PRODUCT DATA SHEET Sika Unitherm Platinum

Refer to Substrates & Surface Preparation.

Aliphatic Acrylic-Polyester Polyurethane

10P20-14 High Solids Low IR Primer

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Aerodur CF Primer 37047

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

DULUX WEATHERGUARD FINE TEXTURED

SECTION 1045 PAINT FOR STRUCTURAL STEEL

1-part polyurethane pourable self levelling floor joint sealant

White, a range of ready-mixed colours, and colours from the Dulux Colour System

Technical Data Sheet. Humidur FP Brush Extreme Product Description. Manufacturer s Information

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

PercoTop Primer 010 CS310 / CS311 / CS312 / CS313 / CS315 / CS316 1K Primer

The Application Guide offers product details and recommended practices for the use of the product.

ASTEC ANTI-GRAFFITI CLEAR COATING POLYURETHANE SILICONE MODIFIED TYPE. Aliphatic 2 Pack Polyurethane Anti-graffiti coating. PRODUCT DESCRIPTION

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

EPOXY FLOORING SYSTEMS

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

Corlar LV PR 178 Series Epoxy Primer

Product Information D8120

Diescolith SOL-Silikat

HYDROJETTING INFORMATION. a six page issue October 1999

4970 PRIME COAT FZ Two components zinc phosphate epoxy product

SP-100 Equipment Wash SP-110 Tool Cleaner

Section COATING RESTORATION

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

DP4101 / DP4104 / DP4107 HS PRIMER

64C1-2-A High Temperature Resistant Insulative Coating

SikaCor 255 Epoxy-binder for mortars on concrete and steel. Protective Coatings

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

January 2007 Product Information ENVIROBASE HIGH PERFORMANCE

RUST TRAP TECHNICAL DATA SHEET

RUST TRAP TM TECHNICAL DATA SHEET

Construction. 2-part epoxy protective coating. Product Description. Product Data 1 1/5. Test. Form. Storage

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Data Sheet 1806 Englisch

Rust Bullet Home and Farm FAQ s

Crystoflex Max comprising of a liquid component of selected polymers and a powder component of selected cements, fillers and aggregates.

TECHNICAL DATA SHEET

Instruction Guide APPLICATION OF CIM TO CONCRETE

Colourthane C-Series. Marine Guide

TT-P-1757B Type I, Class C, Aerosol Zinc Chromate Primer. A one component, alkyd base, corrosion inhibiting zinc chromate primer.

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

One-part High Performance Sealant for Flooring

TECHNICAL DATA SHEET

International Fireproof Technology Inc.

Transcription:

Approved 390;21780;21840 1,2 390 unsaturated polyester ^(ValidationDate) 1 Product description This is a styrene free glass flake reinforced unsaturated polyester coating. It is an ultra high build, extremely abrasion resistant and fast curing barrier coating. Can be used as primer, mid coat or finish coat in atmospheric and immersed environments. Suitable for properly prepared carbon steel, stainless steel, aluminium and approved primers. It can be applied down to +5 C surface temperature. Typical use Recommended for areas subject to extreme mechanical wear and harsh exposure conditions. Recommended for offshore environments, including splash zones, jetties, piles, tidal zones, decks, battery rooms, power stations, exterior of buried tanks, concrete bunds, refineries, bridges, mining equipment and general structural steel where future maintenance is challenging. Other Approvals and certificates Prequalification testing in accordance with NORSOK M501, Rev. 3/4, System 7, suitable for splash zone. Additional certificates and approvals may be available on request. Colours selected range of colours Product data Property Test/Standard Description Solids by volume calculated 98 ± 2 % Gloss level (GU 60 ) ISO 2813 matt (035) Flash point ISO 3679 Method 1 53 C Density calculated 1.2 kg/l VOCEU IED (2010/75/EU) (theoretical) 5 g/l The provided data is typical for factory produced products, subject to slight variation depending on colour. Gloss description: According to Jotun Performance Coatings' definition. Film thickness per coat Typical recommended specification range Dry film thickness Wet film thickness Theoretical spreading rate 600 650 1.6 1500 1610 0.6 μm μm m²/l Date of issue: 3 April 2018 Page: 1/5

All vinyl ester and polyester resin systems are subject to some shrinkage during the curing process. This results in a practical spreading rate lower than the theoretically calculated. The shrinkage depends on actual dry film thickness applied and conditions during application. Surface preparation To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any contamination. Surface preparation summary table Surface preparation Substrate Minimum Recommended Carbon steel Stainless steel Aluminium Coated surfaces Sa 2½ (ISO 85011) with a surface profile Medium to Coarse G (ISO 85032) 2½ (ISO 85011), Fine G (ISO 85032) 2½ (ISO 85011), Medium to Coarse G (ISO 85032) Clean, dry and undamaged compatible coating (ISO 129444 6.1.4) Sa 2½ (ISO 85011) with a surface profile Medium to Coarse G (ISO 85032) 2½ (ISO 85011), Fine G (ISO 85032) 2½ (ISO 85011), Medium to Coarse G (ISO 85032) Clean, dry and undamaged compatible coating (ISO 129444 6.1.4) Application Application methods The product can be applied by Spray: Brush: Standard airless spray may be used. Dedicated two component airless spray is an option. Recommended for stripe coating and small areas. Care must be taken to achieve the specified dry film thickness. Mixing ratio table Additives The steel temperature shall not be lower than the paint temperature and not more than 20 C above the paint temperature. Additive volumes (ml) in 16 litres product. Paint temperature Additive 59 C 1014 C 1519 C 2024 C 2529 C 3034 C Jotun Peroxide 13, Andonox KPM or Trigonox 61 Jotun Inhibitor 53 400 15 30 40 50 60 Date of issue: 3 April 2018 Page: 2/5

With twocomponent airless spray equipment add Jotun Peroxide 13, Andonox KPM or Trigonox 61: 59 C: 2.5 vol% 1034 C: 1.25 vol% At paint temperatures above 15 C Jotun Peroxide 13 can be replaced by equal amounts of Jotun Peroxide 1. For other additive suppliers please consult Jotun. WARNING: Accelerators must never come in direct contact with peroxides. All peroxides must be stored in a dark and cool storage room (below 25 C), and kept away from all kind of combustible materials. Exposure to direct sunlight must be avoided. Use only original or approved containers. Empty containers should be washed with water and kept in separate storage/containers. The peroxide may catch fire if exposed to sparks or to hot metal dust from grinding or other mechanical work. The curing reaction develops heat. For leftovers of mixed paint it is recommended to fill the tin with water to avoid excessive heat development. Thinner/Cleaning solvent Thinner: Vinyltoluene Cleaning solvent: Jotun Thinner No. 17 / Jotun Thinner No. 27 Guiding data for airless spray Nozzle tip (inch/1000): 2735 Pressure at nozzle (minimum): 150 bar/2100 psi Drying and Curing time Substrate temperature 5 C 10 C 15 C 23 C 40 C Using two component airless spray Surface (touch) dry Walkondry Dried/cured for service 2.5 h 2.5 h 2 h 45 min 45 min 2.5 h 2.5 h 2 h 45 min 45 min Dry to over coat, minimum 2.5 h 2.5 h 2 h 45 min 45 min Using one component airless spray Surface (touch) dry Walkondry 3 d 2 d 2 d 12 h 4 h 3 h 2.5 h 2 h 2 h 3 h 2.5 h 2 h 2 h Dry to over coat, minimum 3 h 2.5 h 2 h 2 h Dried/cured for service 3 d 2 d 2 d 1 d For maximum overcoating intervals, refer to the Application Guide (AG) for this product. Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and at average of the DFT range for the product. Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal tackiness. Walkondry: Minimum time before the coating can tolerate normal foot traffic without permanent marks, imprints or other physical damage. Dry to over coat, minimum: The recommended shortest time before the next coat can be applied. Date of issue: 3 April 2018 Page: 3/5

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended environment/medium. Induction time and Pot life Paint temperature 23 C Pot life 1520 min Reduced at higher temperatures. After addition of inhibitor for one component ordinary airless spray: 35 min. Heat resistance Continuous Temperature Peak Dry, atmospheric Immersed, sea water 90 C 100 C 50 C 50 C Peak temperature duration max. 1 hour. The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these temperatures. Note that the coating will be resistant to various immersion temperatures depending on the specific chemical and whether immersion is constant or intermittent. Heat resistance is influenced by the total coating system. If used as part of a system, ensure all coatings in the system have similar heat resistance. Product compatibility Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product. Some examples are shown below. Contact Jotun for specific system recommendation. Previous coat: Subsequent coat: unsaturated polyester unsaturated polyester, polyurethane, polysiloxane Packaging (typical) Volume (litres) Size of containers (litres) 16 20 The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Storage Date of issue: 3 April 2018 Page: 4/5

The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care. Shelf life at 23 C 6 month(s) In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to reinspection. Caution This product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical documentation. Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing the work. Health and safety Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately. Colour variation When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering. Disclaimer The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and practical experience. Jotun's products are considered as semifinished goods and as such, products are often used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves the right to change the given data without further notice. Users should always consult Jotun for specific guidance on the general suitability of this product for their needs and specific application practices. If there is any inconsistency between different language issues of this document, the English (United Kingdom) version will prevail. Date of issue: 3 April 2018 Page: 5/5