Public Works Division Lighting District Supplemental Specifications For Solar School Flashing Beacon Installation March 2007

Similar documents
A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

Douglas County Traffic Signal Installation Guidelines (January 2013)

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

(Condensed from National Electric Code)

CONDUITS AND FITTINGS

CHAPTER 11 CONDUITS AND FITTINGS

Welcome to Douglas County PUD

SECTION GROUNDING AND BONDING

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

PATHWAYS FOR COMMUNICATIONS SYSTEMS

UNDERGROUND SERVICES - GENERAL SERVICE AND MULTI-UNIT RESIDENTIAL

WOOD POLE SPAN WIRE SIGNAL SYSTEMS

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

PRIMARY LINE EXTENSION

A. Product Data shall be provided for each type of product indicated.

Section 2: Underground

DIVISION 1100 TRAFFIC

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

INSTALLATION OF AIRFIELD LIGHTING UNDERGROUND ELECTRICAL DIRECTIONAL BORE DUCT

Installation of CSST Gas Piping Systems

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

UNDERGROUND SERVICES SECONDARY

The University of Texas at Austin September 30, 2011

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

St. Clair County Electrical Code Regulations

Permitting and Inspecting PV Systems. PV Codes and Standards 101. Photovoltaic System Basics

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Section 820. TRAFFIC SIGNALS

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

A T L A N T I C O C E A N

Product Specifications MRI Trench Duct

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES

Basic Service. This Section provides information regarding a. Introduction

TS 801 ELECTRICAL WORK - GENERAL TABLE OF CONTENTS

ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Underground Service Requirements and Instructions

WIRING RULES AND REGULATIONS OF TOMBIGBEE ELECTRIC POWER ASSOCIATION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POLES

1.1 Related Work.1 Electrical Pathway Lighting Design Spec.: Section 16010

For Silverback Solar

Standard of Practice - Campus Electrical Distribution System

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

Specification Lightning Protection Systems

Building Attachments and Services

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

The following is a summary of parameters for preparation of a traffic impact analysis when such analysis is required by the City of Highland:

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.

WIRING METHODS CHAPTER 38

ELECTRICAL SAFETY Information Bulletin

NEC 2014 Code Changes

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SPECIFICATIONS - DETAILED PROVISIONS Section Plastic (PVC) Pressure Water Pipe & Fittings C O N T E N T S

Specifications for Residential Underground Electric Service Installation

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION INSULATED WIRE AND CABLE

Division 11 - Equipment Section 11401

Electric Service Handbook

Service Entrance Cable Fittings

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

SECTION ALUMINUM WINDOWS

SECTION LIGHTING

SECTION SEISMIC CONTROL OSHPD

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

TECHNICAL PROCEDURE TABLE OF CONTENTS

Basic Requirements for Residential Electrical Installations

Specifications Electrical Metallic Tubing (EMT)

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy.

Design Standard Conduit for Electrical Systems

Electric Service Standards

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

TILE TILE

SECTION CHAIN-LINK FENCES AND GATES 02821/1

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

TEMPORARY METER POLE INSTALLATION

INSTALLATION OVERVIEW

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SWIMMING POOL PERMIT AND INSPECTION REQUIREMENTS

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp,

Transcription:

Public Works Division Lighting District Supplemental Specifications For Solar School Flashing Beacon Installation March 2007 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

CHARLOTTE COUNTY LIGHTING DISTRICT SUPPLEMENTAL SPECIFICATIONS FOR SOLAR SCHOOL FLASHING BEACON INSTALLATION MARCH 2007 PURPOSE: All work associated with the installation of a school flashing beacon shall conform to current Florida Department of Transportation (FDOT), National Electrical Codes (NEC), and this supplement. It is the intent of this supplement to detail these installation requirements, dictated by the County, which exceed standard FDOT and NEC requirements. It is the Contractor s responsibility to note these extended specifications and to adhere to the methods and requirements mandated in this document. Included within this document is a photo illustrating the intended appearance of the finished product. WORKMANSHIP: All work is to be performed in a workmanlike manner. It is the Contractor s responsibility to provide the labor, skilled in the appropriate areas, necessary to provide an acceptable and professional finished product. The Contractor and his personnel shall have, at all times, all the necessary paperwork needed to complete the job. It is expected that plumb surfaces shall be plumb. Spacing of multiple components, such as conduit stubs or straps, shall be in equal increments. All materials shall be in new or like-new condition. All school flashing beacon poles shall be leveled to the satisfaction of the Lighting District Inspector. During all working hours, the Contractor shall have a responsible, English-speaking superintendent on the project, with the capabilities and authority required by FDOT Specifications, Section 5-8. All cabinet-related work shall be performed by an International Municipal Signal Association (IMSA) Level II Technician, certified in traffic signals. This certification shall be presented at the pre-construction conference or upon request. The Charlotte County Lighting District Inspector assigned to the project shall have the authority to make final determinations on whether workmanship, materials, and/or final product(s) meet the specifications contained herein. The Contractor shall submit cut sheets on all materials proposed for the installation of a solar school flashing beacon. The material submittal will be reviewed by Charlotte County for conformance and returned to the Contractor within three business days. The Contractor shall be responsible for coordinating with all utilities having overhead or underground facilities in close proximity or possible conflict with the Contractor s

excavations and underground cable installation. The Contractor shall notify all utility companies and maintaining agencies 48 hours in advance of commencing work. Hand digging will be required in all areas where the utilities stake or locate a possible conflict, or where hand digging is specified on the plans. The exact location of utilities shall be determined by the Contractor, when necessary, during construction. CONCEALED WORK: All work which will not be readily visible upon completion shall not be concealed until a County Lighting Inspector gives approval. In the event the below items are concealed, it will be the Contractor s responsibility to expose the questioned item(s) for the Inspectors approval, at no additional cost to the County. This includes, but is not limited to: Buried or imbedded conduit Ground wire, rods, and array SURFACE TREATMENTS: The application of the following materials to various solar school flashing beacon components shall be performed during assembly: Threaded Hardware: All non-electrical threaded hardware (i.e., all Astro Brac hardware, pole hardware, or any threaded surface) shall be coated with Permatex Anti-Seize Lubricant or County-approved equivalent. No spray-on anti-seize compound will be accepted. The amount of anti-seize being applied shall be sufficient to be visibly seen. Gasketing Surfaces: All gasket surfaces shall be lightly coated with County-approved silicone grease. Electrical Connections: All mechanical/electrical connections shall have the various components of the splice or termination coated with a County-approved oxide inhibitor. Weatherproofing: Irregular mating surfaces shall be rendered weatherproof by applying an appropriate bead of clear silicone caulk, such as Silicone II or County-approved equivalent. The areas to be sealed are those which are typically prone to moisture infiltration. Cable Entry/Exit Wherever a cable enters or exits a field-drilled hole, the hole shall be protected by a permanently-installed rubber grommet. GROUNDING: Minimum size of all ground/bond wire will be stranded #6 AWG. Bare wire will not be accepted inside a conduit. Ground wire shall be attached to the ground rod by means of a

grounding acron with a hex bolt. Exothermic bonding of ground wire to ground rods will not be acceptable. Multiple conductors shall not be joined together with a grounding acron. One conductor shall be terminated under the acron, and all others shall be joined with a split bolt. The grounding wire shall be attached to the pole base by means of a solderless lug. All ground rods shall be 5/8" x 10', copper clad bonded to a steel core. BASE AND POLE: Solar school flashing beacons shall be mounted onto a square pedestal base using Pelco, part #PB 5335. The base assemblies shall be equipped with Pelco, part #PB 5325 pole and base collar assembly. All poles are to be aluminum and shall have a spun finish. The length of the pole shall be sufficient to mount the sign so that the bottom of the sign is 7 above the edge of pavement elevation. The pedestal base shall be mounted on a concrete base. Details of the concrete base shall follow the Florida Department of Transportation Design Standard Index 17764. SIGNAL EQUIPMENT: Each school flashing beacon shall have a three-section traffic signal display, with two displays facing forward and one facing rearward. Each of the three sections shall utilize a tunnel visor. Each signal indication shall have a 12 volt DC, 12 yellow LED module insert, as manufactured by Gelcore. The signal displays shall be mounted to the aluminum pole by means of a rigid signal mount, Pelco part #SE0567. The two forward facing signal indications shall flash alternately. Each solar beacon shall be equipped with a minimum of one 65 watt solar panel. The solar panel shall be mounted to the pole by means of an aluminum slip fitter collar. The antenna shall be mounted on the solar panel. A Beldon cable shall be installed between the solar panel and the flasher cabinet. The solar panel shall face in a southerly direction. CABINET: Each solar beacon shall be equipped with a solar flasher cabinet as manufactured by Transportation Control Systems, located at 1030 86 th Street, Tampa, Florida 33619, Phone (813)630-2800. The solar flasher cabinet to be used is part number TCSFLN202S. Each cabinet shall contain a 100 AH sealed, deep-cycle battery. The time clock shall be an RTC brand CPR2102 pager programmable time switch. SIGN: The sign shall be mounted to the pole by means of four ½ U bolt sign clamp as manufactured by Pelco, Part #SH0209.

The signs speed limit shall be 15 MPH and follow the specifications below:

Example: Solar school flashing beacon example.