Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Similar documents
DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Composition Analysis of Animal Feed by HR ICP-OES

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

ICP Expert software. Technical Overview. Introduction

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

Avio 200 ICP-OES Flat Plate

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

DRPK-005

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

GB Translated English of Chinese Standard: GB

The image part with relationship ID rid4 was not found in the file. Welcome

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

National Food Safety Standard

US EPA Method using the XSERIES 2 ICP-MS

Method for Estimation of Na 2 O and K 2 O in Ores, Fluxes, Coal and Coke Ash by Inductively Coupled Plasma-Atomic Emission Spectroscopy

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

Kunikazu Ide and Yoshisuke Nakamura. 1. Introduction

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

Aluminium Determinations in Parenteral Solutions

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7600 ICP-OES Duo

Determination of Elemental Bad Actors (As, Hg and Si) in Petrochemical Samples Using ICP-AES and ICP-MS

SEMASPEC Test Method for Metallurgical Analysis for Gas Distribution System Components

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

Issue February 2017 Valid to December ISO 9001 Registered Quality Management

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

Analysis of Cast Iron Using Shimadzu PDA-7000

3 rd International Conference and Exhibition on Food Processing & Technology

Thermo Scientific icap Q ICP-MS

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

High-Purity Acids & Reagents

Monitoring and fractionation of

Certificate of Analysis BS 110B

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Assaying and Analysis Choices in Practice

Faster, easier, flexible proteomics solutions

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

ISO INTERNATIONAL STANDARD

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

Certificate of Analysis

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017

CORESTA RECOMMENDED METHOD N 61

CERTIFICATE OF ANALYSIS REVISED REPORT

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Multitype ICP Emission Spectrometer ICPE-9000 C113-E012J

The Many Facets and Complexities of 316L and the Effect on Properties

Thermo Scientific icap 7000 Series ICP-OES Accessories Guide

PinAAcle 900 Series. Atomic Absorption Spectrometers

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Thin-Layer Chromatography of Aluminium: Quantitative Densitometric Determination of Fe 2+, Ni 2+, Cu 2+, and Si 4+

METHOD 3031 ACID DIGESTION OF OILS FOR METALS ANALYSIS BY ATOMIC ABSORPTION OR ICP SPECTROMETRY

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

Effect of Chromium on Nitrogen Solubility in Liquid Fe Cr Alloys Containing 30 mass% Cr

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Hastelloy G-30 (UNS N06030) Chemical Composition

NORRIS. Drive Rods. Engineered performance. Designed tough.

Agilent 6430 Triple Quadrupole LC/MS System

The Release of Nickel from Stainless Steel into Cooked Foods

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Determination of Iron Content in Different Hemoglobin Samples from Some Patients by UV-Visible Spectrophotometer

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

Using low grade silicon carbide and leftover construction soil to fabricate green bricks

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

Transcription:

Analysis of steel and its alloys using the GB/T 20125-2006 standard and an Agilent 5100 ICP-OES in dual view mode Application note Metals analysis and production Authors John Cauduro Agilent Technologies Melbourne, Australia Introduction Steel manufacturers conduct quality control testing for a range of metals and trace elements to ensure the grade and performance of their final product. The Standardization Administration of China uses their GB/T 20125-2006 standard Low-alloy steel Determination of multi-element contents Inductively coupled plasma atomic emission spectrometric method to control the quality of manufactured steel products. Different grades of steel have different specifications for elemental content, with most steel and stainless steel grades required to have less than 0.05 % by weight of Sulfur and 0.04 % by weight of Phosphorus. With the Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) technique easily able to measure elements at this concentration within a sample, laboratories are looking beyond whether an instrument can do the job to whether a specific instrument can improve their sample throughput, lower their costs, simplify sample preparation and instrument operation, and deliver reliable results throughout the analysis of a large batch of samples.

This application note demonstrates the performance and benefits of Agilent s 5100 Vertical Dual View (VDV) ICP-OES instrument in the analysis of steel samples, using the GB/T 20125-2006 method. The instrument offers many advantages for this application, which involves the rapid analysis of a large number of challenging steel samples. Experimental Instrumentation Agilent s 5100 Vertical Dual View (VDV) ICP-OES was used for this analysis and has a range of features that deliver high sample throughput and reproducible, accurate results for challenging steel samples. The instrument uses the Vista Chip II detector with a 1 MHz processing speed, the fastest of any charge coupled device (CCD) detector used in ICP-OES. This delivers high throughput, high sensitivity, and the largest dynamic range. The instrument s Vertical Dual View (VDV) configuration allows measurements to be performed in axial and radial modes. The analyst can achieve sensitivity for elements in low concentrations such as phosphorus and sulfur by measuring them in axial view as well as measuring percent concentrations of nickel and chromium, without having to dilute the sample, by using radial view. Refer to Table 2 to determine which plasma view was used for each element. Agilent s 5100 VDV ICP-OES features a vertical torch, capable of handling the toughest matrices. Over the years, a vertical torch has been accepted as a standard configuration for running challenging matrices as it requires less cleaning and fewer replacements [1]. The combination of the vertical torch and a robust solid state radio frequency (SSRF) system operating at 27 MHz, provides a reliable, robust plasma, delivering excellent long term stability for challenging samples. This means accurate results even at the end of a whole day of measuring steel sample digests. The plug-andplay torch loader automatically aligns the vertical torch and connects the gases for fast start up, ensuring reproducible results, even with multiple operators. For the analysis, the RF power was increased to 1.5 kw and the nebulizer flow rate was set to 0.55 L/min to improve the detection limits for difficult elements such as S and P in the elevated Fe matrix. The plasma flow was left at a low setting of 12 L/min and did not need to be increased to handle the higher RF power and complex matrix. Instrument operating conditions are listed in Table 1. For this application, the 5100 VDV ICP-OES was fitted with a sample introduction system comprising a OneNeb nebulizer, double-pass glass cyclonic spray chamber and a 5100 Dual View torch (demountable, quartz, 1.8 mm injector). An SPS 4 autosampler was used to deliver sample to the instrument. Table 1. Instrument operating parameters. Parameter Setting Torch Demountable Dual View torch (1.8 mm ID injector) Nebulizer OneNeb Spray chamber Double-pass glass cyclonic Read time (s) 20 for axial, 5 for radial Replicates 3 Sample uptake delay (s) 15 Stabilization time (s) 10 Rinse time (s) 50 Fast pump (80 rpm) Yes Nebulizer gas flow (L/min) 0.55 RF power (kw) 1.5 Plasma gas flow (L/min) 12.0 Aux gas flow (L/min) 1.0 Sample preparation Two CRMs, GH 135 6934 and GSBH 40031-93 (China National Analysis Center for Iron and Steel), were analyzed to verify the method, with the certified concentrations of elements in the CRMs shown in Table 3. The sample was prepared by digesting 0.5 g of the CRM in a combination of nitric, hydrochloric, and perchloric acids on a hot plate, as described in the GB/T 20125-2006 method. The digest was made up in a 100 ml volumetric flask using 18 M Ω de-ionised water, giving a TDS of approximately 0.5 %. 2

Standard preparation Multi-element calibration standards were prepared from Agilent single element stock solutions. Blanks and standards were all matrix matched with a 5000 mg/kg Fe sample, which was made using the same digestion method as the samples, using a 6N high purity iron wire. Correction techniques Inter Element Correction (IEC) was required for S due to the presence of Mn, Mo and Ti interferences, and for As due to the presence of Cr interference. To simplify the analysis, the calibration standards were used as IEC analyte standards. Single element interferent standards were prepared in the same Fe matrix used in the calibration standards. IEC factors were simply setup using the ICP Expert 7 software and once the factors were determined, they were stored in a template and reused in subsequent analyses. No internal standard correction was required. A combination of Fitted Background Correction (FBC) and off-peak background correction techniques [2] were used to correct for any spectral interferences. The FBC technique simplifies method development and ensures fast, accurate background correction by eliminating the need to determine off-peak background correction points for each element. Table 2 lists which method was used for each element. Table 2. The background correction method and plasma view used for each element. Element & wavelength (nm) Background correction used Plasma view Al 396.152 Fitted Radial As 193.696 Off-Peak Right Axial Co 228.615 Fitted Axial Cr 267.716 Fitted Radial Cu 327.395 Fitted Axial Mn 257.610 Fitted Radial Mo 202.032 Fitted Radial Ni 231.604 Fitted Radial P 178.222 Off-Peak Left Axial S 181.972 Fitted Axial Si 251.611 Fitted Axial Ti 334.941 Fitted Radial V 309.310 Fitted Axial Results and discussion Calibration linearity Linear calibrations were obtained with a correlation coefficient greater than 0.99999 for all wavelengths over a wide concentration range. This high degree of linearity means the wide range of concentrations expected in steel samples can be determined without the need to perform additional dilutions. This improves sample throughput and removes potential dilution errors and sample contamination. Figures 1 3 show typical calibration curves for Cr, Ni and P for this application. Standards Conc % Error (ppm) Blank 0 N/A Standard 1 10 0.44 Standard 2 100 0.60 Standard 3 1000 2.82 Figure 1. Calibration curve and standard concentrations Cr 267.716 nm line. 3

Method Detection Limits and CRM recoveries For this application, MDLs were determined by analyzing the 5000 mg/kg Fe matrix blank solution 10 times. The MDL was calculated as 3 times the SD of the 10 measurements of the matrix blank. This analysis was performed on 3 independent runs. Standards Conc (ppm) % Error Blank 0 N/A Standard 1 20 0.08 Standard 2 200 2.32 Standard 3 2000 1.08 Figure 2. Calibration curve and standard concentrations Ni 231.604 nm line. The CRMs (GH 135 6934 and GSBH 40031-93) were analyzed in duplicate, with the results averaged over 3 separate analyzes. The results shown in Table 3 display excellent recoveries within ±10% of the certified value, demonstrating the accuracy of the instrument when analyzing samples with difficult matrices. Long term stability test The long term stability and precision of the method was tested by continuously analyzing a steel sample for 8 hours. The results (Figure 4 and Table 4) show the measurement precision for all elements over 8 hours was < 1.5% RSD. This demonstrates that the 5100 will reliably deliver accurate measurements over many hours of measuring challenging samples like the steel digests. Standards Conc (ppm) % Error Blank 0 N/A Standard 1 0.1 5.06 Standard 2 1.0 0.06 Standard 3 10.0 0.14 Figure 3. Calibration curve and standard concentrations P 178.222 nm line. Figure 4. Long term stability plot of a steel sample, analyzed continuously over 8 hours. 4

Table 3. MDLs in the solid sample and recoveries for 13 elements in two CRMs. MDLs were determined in a 5000 mg/kg Fe matrix. MDL Measured CRM GH 135 6934 CRM GSBH 40031-93 SD Certified conc. Recovery (%) Measured SD Certified conc. Al 396.152 3.8 30761 465 31500 97.7 183.5 1.7 170 107.9 As 193.696 2.0 38.9 1.7 NA 66.7 1.5 66 101.0 Co 228.615 1.4 71.1 0.9 NA 57.0 0.5 58 98.4 Cr 267.716 1.7 143030 1955 139400 102.6 370.1 3.1 350 105.7 Cu 327.395 0.23 216.3 3.7 NA 328.6 2.8 340 96.7 Mn 257.610 0.43 4719 65 4500 104.9 5940 46 5500 108.0 Mo 202.032 2.2 18526 232 18400 100.7 57.7 2.4 59 97.8 Ni 231.604 5.2 366424 4984 358500 102.2 270.0 2.7 260 103.9 P 178.222 2.6 40.6 1.6 40 101.5 167.6 2.1 170 98.6 S 181.972 3.4 39.7 10.9 37 107.3 170.3 2.8 170 100.2 Si 251.611 1.6 4391 36 4520 97.1 2342 15 2280 102.7 Ti 334.941 0.60 25809 310 24490 105.4 2.3 0.2 NA V 309.310 0.81 1007.4 7.9 NA 4.4 0.2 NA Table 4. Long term stability data (%RSD) of a steel sample. Elements Al 396.152 As 193.696 Co 228.615 Cr 267.716 Cu 327.395 Mn 257.610 Mo 202.032 Ni 231.604 P 178.222 S 181.972 Si 251.611 Ti 334.941 Recovery (%) %RSD 0.88 1.47 0.76 0.93 0.71 1.04 1.05 0.88 1.24 1.35 0.79 0.92 0.88 V 309.310 Conclusion Agilent s 5100 VDV ICP-OES with a vertical torch operating in dual view mode was used to measure two steel certified reference materials, using the GB/T 20125-2006 standard Low-alloy steel Determination of multi-element contents Inductively coupled plasma atomic emission spectrometric method. Despite the difficult samples, the dual viewing capability of the instrument, combined with the GB/T method, delivered accurate results, with recoveries within ±10% of the certified value. The vertical torch and robust SSRF system of the instrument delivered long term measurement stability, with the measured %RSD for all elements over 8 hours being less than 1.5%. The wide linear dynamic range of the instrument makes it ideal for the routine analysis of steel samples in a busy laboratory as it reduces the need for sample dilutions, which add to sample preparation time and introduce the risk of errors. The software supplied with the instrument includes a selection of background correction techniques. This allowed accurate results to be achieved by correcting for any spectral interferences present in the difficult sample matrix. The Agilent 5100 VDV ICP-OES was able to quickly, accurately and reliably measure the steel digest samples, despite the challenging matrix and wide range of analyte concentrations. References 1. Benefits of a vertically oriented torch fast, accurate results, even for your toughest samples, Agilent publication, (2014), 5991-4854EN 2. Fitted Background Correction (FBC) fast, accurate and fully automated background correction, Agilent publication (2014), 5991-4836EN 5

www.agilent.com Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2015 Published November 27, 2015 Publication number: 5991-6157EN