CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Similar documents
UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

UV400 ATEX. Online Water Analyser. Specialist Of UV Spectroscopy

UV400. Online Water Analyser. Specialist Of UV Spectroscopy

Fpollutant-free zero air for analytical

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

GAS 3050P NDIR FLUE GAS

OptiLIS 201 & 301. Online multi-parameter continuous water analyzers. OptiLIS 201 OptiLIS 301

Sensor unit MC2 for toxic gases and oxygen with analog output

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Cleaning Validation PRODUCT OVERVIEW

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Online Gas Analyzer / Monitor

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Compact flue gas analyser: testo 300 M-I

EuroFID Total Hydrocarbon Analyzer

Using the PPM2 Portable Trace Moisture Transmitter

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

8 stream capability with dual mode (H 2 S & total Sulphur)

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Fine particle measuring system

INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Multiphase Flow Measurement. Multiphase Flow Meter Wet Gas Meter Multiphase Wet Gas Flow Meter Well Testing Service

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

New Measurement Engineering For Monitoring Emissions In Industry

NovaWAVE. A new category of Automated Microwave Digestion

PRODUCT CONFORMITY CERTIFICATE

Carbon. Carbon. Carbon parameters: Carbon

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Highly efficient flue gas analyzer

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

TOC SYSTEMS INC. On-Line TOC Analyzer. Features -CHOICE OF PLATFORMS- Options. Combustion ON - LINE HIGH TEMPERATURE COMBUSTION

HOBO Plug Load Logger (UX ) Manual

PORTABLE FLUE GAS ANALYZER

Chloride/Sulfate Analyzer

GMS800 FIDOR Total hydrocarbon analyzer. Gas Analyzers

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

EUROλYZER STx. Flue Gas Analyzer. BlueLine

S700 Modular Gas Analyzer. Measures more than 60 different gases

testo 340 Speed, power & precision in industrial combustion analysis.

ACX Analyzer systems for emission monitoring, cement applications and process measurement

Heat Value Gas Chromatograph ISO standard version

ADI 7010 TOC Analyzer. Continuous monitoring of total organic carbon

FITOCLIMA WALK-IN STABILITY

The. universal 3D Inspection reference. advanced 3D measurement software & solutions

Process Analyzer. UV Oil in Water Analyzer Model W-800. Credible Solutions for the Oil and Gas Industry

Just a few clicks away from a heating system

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

3SP_CO_1000 Package

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

ON-LINE OIL TRACE MONITOR

ProFoss for in-line process analysis of dairy powder

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Process Analyzers. Continuously measure the chemicals in a liquid or gas process stream using the future of industrial process analytics: the OMA.

Technical System Catalogue Modular PDU (PSM)

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

Thermo Scientific GENESYS 10S Bio spectrophotometer

i-thermo Moisture Analyzer

REAL-TIME DUST MONITOR TEOM 1405-F

Online Wastewater Process Monitoring

COMBIMASS Thermal Gas Flow

testo 350 M testo 350 XL

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

testo 330 Flue gas analysis with increased convenience and safety

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Combustion Master CS Carbon and Sulphur Analyser

SpectraSensors SS500 Mid-Sensitivity Moisture Analyzer

GreenLine 6000 GreenLine 8000

RapID Raw Materials Verification System

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

Comp. Tag No. Component Title Options Installation Detail No.

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

PORTABLE HARDNESS TESTING

REFERENCE MEASURING INSTRUMENT

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

A Multi-Element Smart Gas Sensor

PRESENTS A RFID THE JANUS* GATE: RFID TERMINAL SYSTEM FOR CONTAINERS CCCCCONTAINERS CONTAINERS RFID NEPTUNESEAL * CONTAINER BOLT SEAL

Reliable, low-maintenance process heating

Carbon / Sulfur Analyzers

PRODUCT CONFORMITY CERTIFICATE

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

Oil on Water Monitor Model. FLUCOmat (FLU 103) Non Contact Detection of: Mineral oils Synthetic oils Oil- Emulsions Free Hydrocarbons

Agilent 4339B/4349B High Resistance Meters Technical Overview

COATING THICKNESS MEASURING

Transcription:

CEM500-L Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf

> CEM500-L Online Gas Analyser The CEM500 is an extractive online gas analyser dedicated to Continuous Emission Monitoring It is specifically dedicated to the new low level emission regulations known as 50/30/5/3 (50 mg/nm3 NOx, 30 mg/nm3 SO2, 5 mg/nm3 particles, 5 µg/nm3 mercury) and also to chemical processes requiring low values of H2S. This new model is based on a multi-path flow cell of 1200 mm coupled to a high resolution spectrograph (0.1 nm) using an ultra-sensitive 2048 pixels CCD (Charge-Coupled Device). It gives a high sensitivity and a longer lamp life time (3 years). The UV spectroscopy brings a higher sensitivity than infra-red spectroscopy and also gives the possibility to measure several gases simultaneously on the same spectrograph. A high selectivity is achieved by doing a fast Fourier transform (FFT) on the absorbance spectrum for the gases with periodic structure like NH3, SO2, CS2 and others. The internal gas circuit, including the optional sampling pump, is heated at 240 C to admit directly hot and humid combustion gases and also to avoid the deposits along the tubing and windows. 2

Main Method : UV Spectroscopy Several gases can be measured simultaneously thanks to the UV spectroscopy method by using different wavelengths and algorithms. For gases with a periodic absorption spectrum such as NH3, SO2, NO, CS2 or acetylene, an algorithm based on FFT (Fast Fourier Transform) guarantees a very good selectivity of measurement. The solid-state design due to the UV spectroscopy gives a high reliability of the measuring system with quite no maintenance. The UV lamp is a xenon flash lamp with a high lifetime and without thermal effect that may generate measurement drift. The gas flow cell has two quartz windows to transmit the UV light throught the measured gas. The standard path length of the flow cell is 1200 mm. The spectrograph is based on a concave grating to minimize the optical parts and the spectrum is read on a 2048 pixel CCD with a resolution of 0.1nm. A zero is done automatically on zero air or nitrogen with an adjustable period (if possible every 2 or 4 hours but once per day remains acceptable). The absorbance spectrum is calculated from the reference spectrum acquired during the zero step. The measuring principle is based on the UV light absorption according to the Beer-Lambert Law: [C] = K log Iref Igas [C] : Concentration of the sample K : Absorption coefficient at a specific wavelength for a specific gas Iref : Light intensity on the zero air Igas : Light intensity on the sample Heated Version The analyser is provided with an heating system for the gas circuit. The heating temperature can be adjusted up to 240 C. The high temperature evaporates any deposits on the windows. No Interference with CO, CO2 and CH4 The major emission gases like CO, CO2, and CH4 have no UV absorption,therefore they don t interfere with the measured gases. H2O has a weak absorption in the UV range but at different wavelengths than combustion gases like NH3, NO, NO2 or SO2. Consequently, H2O, with an usual concentration between 5% and 20%, is not disturbing the measurements. Multi-Gas Configuration NO NH3 NO2 SO2 Several gases can be measured in a same analyser if the sample gas composition is compatible with the selected algorithms and wavelengths. The analyser gives high measurement selectivity thanks to the recognition of the specific UV absorption spectrum of gases by using proprietary algorithms. 3

Low Maintenance and High Reliability The design has been specially oriented for low maintenance and high reliability on the measurements. The UV xenon lamp is specified for a lifetime of 10 9 flashes. Therefore, the lifetime is about 3 year with continuous measurements or 10 years with one measurement per minute. This reduces considerably the maintenance and the risk of wrong measurement due to aged lamps or its replacement. A colour touch screen display interface allows the user to easily navigate through a number of screens that are used to set and check all of the operating conditions of the instrument. User-Friendly Interface A protective film limits the risk to damage the surface of the touch screen, especially against solvent and corrosive liquid. Gas Circuit Analyser Heated Part Pressure Sensor Pump Three gas connections are available on the rear panel of the analyser : Inlet for the sample - Zero air or nitrogen - Outlet for sample or zero - NC NO Gas Flow-Cell Inlet and zero are connected on a 3 ways electric valve. When the automatic zero is activated, the solenoid valve switches the flow cell on zero air. A pressure sensor takes the pressure of measured gas to compensate it and to give a flow indication. All the gas circuit is in a heated compartment controlled within +/- 0.5 C at an adjustable temperature between 40 C and 240 C. An optional pump may be included before the gas flow cell in order to pump the sample as well as the zero gas that may be ambiant air for most of the applications. Inlet Zero Outlet Automatic Compensation An internal measurement of temperature and pressure of the sample is performed. A ratio related to the ideal gas law is applied on the measured value to compensate the effects of temperature and pressure. Recorded data and diagnostic files for each parameter can be downloaded to memory stick thanks to a USB port. Communication This allows to collect easily these files on site without using a computer. The files are in text format and can be directly imported to Excel for graphic charts. 4

> CEM500-L Parameters Specifications 430 mm 595 mm 424 mm 280 mm Parameter Range* (ppm) Range* (mg/m3) Typical Repeatability Detection Limit Typical Detection limit as 3x sigma on zero gas, 60 sec response time at 90%, NH3 Ammonia 0-10 ppm 0-7 mg/m3 0.1 ppm at 10 ppm 0.01 ppm NO Nitrogen Oxide 0-80 ppm 0-100 mg/m3 0.2 ppm at 40 ppm 0.5 ppm SO2 Sulfur Dioxide 0-30 ppm 0-100 mg/m3 0.2 ppm at 30 ppm 0.05 ppm H2S Hydrogen Sulfide 0-100 ppm 0-150 mg/m3 0.1 ppm at 20 ppm 0.1 ppm NO2 Nitrogen Dioxide 0-200 ppm 0-400 mg/m3 2 ppm CS2 Carbon Disulfide 0-20 ppm 0-60 mg/m3 C6H6 Benzene 0-20 ppm 0-60 mg/m3 C7H8 Toluene 0-5 ppm 0-20 mg/m3 C8H10 Xylene 0-5 ppm 0-1000 mg/m3 NCL3 Nitrogen Trichloride 0-20 ppm 0-100 mg/m3 *Higher range available on request 5

> CEM500-L General Specifications Data storage 5000 measurements for all parameters Interfaces Interface RS232 (MODBUS, AK) USB port (for memory stick) Internal WIFI interface IEEE 802.11 B (OPTION) Internal Ethernet 10 BASE-T interface IEEE 802.3 (option) Signals Display Power supply Operatings limits CE standards Enclosure Dimensions Weight Sampling gas Zero gas 1 to 8 analog outputs 4-20 ma opto-isolated (option) 1 to 4 relay contacts programmable (option) LCD colour screen (TFT) with LED backlight 640x480 pixels 110-240 VAC / 1000 VA / 50-60Hz 0 to 40 C, less than 90% as relative humidity Electromagnetic compatibility and safety EN 61010-1, IEC 61010-1 / EN 61326, IEC 61326 Stainless steel IP65 with coating 345 x 595 x 280 mm 33 kg Pressure : 0 2 bar absolute (0 2000 hpa absolute) Flow : 0.1 to 10 L/min Temperature : ambiant to 400 C Fittings : Swagelok, stainless steel 316 for tube OD ¼'' (6.4 mm) Pressure : 0 2 bar absolute (0 2000 hpa absolute) Flow : 0.1 to 10 L/min Fittings : Swagelok, stainless steel 316 for tube OD ¼'' (6.4 mm) The manufacturer reserves the right to modify and/or change any specifications, dimensions, design or drawing at any time without prior notice 6

> CEM500-L Parts references Basic unit CEM500-L Basic unit (one gas included) Recommended flow for sample and zero air: 0.5 to 10 litres/min Fittings: Swagelok stainless steel 316 for tube OD ¼ (6.35 mm) Color graphic display 640x480 pixels with touch screen Built-in data logger, memory 5000 measurements 12 sockets for input and output modules (not included, refer to options) RS232 included (Sub-D 9 ways female connector) with 2 meters cable for PC RS485 included for communication with MODBUS protocol USB Port for USB key (measurements and configuration download, software update) Power supply 110-240 VAC 47-63 Hz 1000 VA with power cord 2 meters Enclosure IP65/Nema4x stainless steel 316 (595x345x280 mm, 33 kg) Mounting lugs for wall Sampling pump not included Heated version at 240 C (adjustable) For use on wet combustion gas Internal pump PUMP500 Internal membrane pump with heated head Built-in inside the enclosure Flow about 6 l/min Heated version at 240 C Auto calibration AUTOCALG500 Auto-calibration for one gas For wall mounting outside the enclosure Additional gases (The measurement range is given for an optical path of 1200 mm) Additional gas 4-20 ma isolated output included NH3 H2S NO NO2 SO2 C6H6 C7H8 C8H10 CS2 C2H2 Ammonia Range: 0 10 ppm NH3 (or 0 7 mg/nm3 NH3) Measurement possible until 100 ppm NH3 (or 700 mg/nm3 NH3) Hydrogen sulphide Range: 0 100 ppm H2S (or 0 150 mg/nm3 H2S) Measurement possible until 200 ppm H2S (or 0 300 mg/nm3 H2S) Nitric oxide Range: 0 80 ppm NO (or 0 100 mg/nm3 NO) Measurement possible until 500 ppm NO (or 600 mg/nm3 NO) Nitrogen dioxide Range: 0 200 ppm NO2 (or 0 400 mg/nm3 NO2) Measurement possible until 500 ppm NO2 (or 1000 mg/nm3 NO2) Sulfur dioxide Range: 0 30 ppm SO2 (or 0 100 mg/nm3 SO2) Measurement possible until 1000 ppm SO2 (or 300 mg/nm3 SO2) Benzene Range: 0 20 ppm C6H6 (or 0 60 mg/nm3 C6H6) Measurement possible until 50 ppm C6H6 (or 150 mg/nm3 C6H6) Toluene Range: 0 5 ppm C7H8 (or 0 15 mg/nm3 C7H8) Measurement possible until 10 ppm C7H8 (or 30 mg/nm3 C7H8) Xylene Range: 0 5 ppm C8H10 (or 0 20 mg/nm3 C8H10) Measurement possible until 10 ppm C8H10 (or 40 mg/nm3 C8H10) Carbone disulfide Range: 0 20 ppm CS2 (or 0 60 mg/nm3 CS2) Measurement possible until 50 ppm CS2 (or 150 mg/nm3 CS2) Acetylene Range: 0 1000 ppm C2H2 (or 0 1000 mg/nm3 C2H2) Measurement possible until 2000 ppm C2H2 (or 2000 mg/nm3 C2H2) 7

> CEM500-L Parts references Input modules IN4-20 4-20 ma input module Isolated 4-20 ma input Impedance: 100 Ohm LOGIC500 Double logical inputs module Input no 1 : external pulse command for measurement Input no 2 : measurements inhibition Isolated 0 24 V DC inputs Impedance: >10 Kohm Output modules OUT4-20-500 RELAY500 4-20 ma output module Isolated 4-20 ma output Active output, Max load 500 Ohm Relay module Contact rating: 2A/220V Communications WIFI500 Wifi Interface Connection to wireless WIFI network Standard IEEE 802.11b Secured data transfer by WEP keys ETHER500 Ethernet interface Ethernet 10 base-t (IEEE 802.3) Recommanded consumables for 2 years : L-XEN-1: xenon lamp with trigger (x1) MKIT-SPL- G-1: Pump kit with membrane (x2) only if sampling pump The manufacturer reserves the right to modify and/or change any specifications, dimensions, design or drawing at any time without prior notice TETHYS Instruments 57, Chemin du vieux Chêne, 38240 MEYLAN -France- Tel : +33 4 76 41 86 39 - Fax : +33 4 76 41 92 27 Mail : sales@tethys-instruments.com Web : www.tethys-instruments.com IND#A - E.COM.09 8