Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Similar documents
SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

HPL CSI 3-PART SPECIFICATION FORM

Specifications for FL-100 Soffit Panel

University Apartments on Brooklyn PROJECT MANUAL

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

Series 3000 Pocket Doors

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION STILE AND RAIL WOOD DOORS

1.3 REFERENCE STANDARDS

SECTION RESILIENT SHEET FLOORING

Section GYPSUM DRYWALL

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION DECORATIVE PLASTIC LAMINATE

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION IMPACT RESISTANT WALL PROTECTION


PRODUCT SPECIFICATIONS

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

ALL-ALUMINUM DOOR & WINDOW FRAMING

2000 POCKET DOOR TECHNICAL DATA

SECTION ACCORDION FOLDING PARTITIONS

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Section SoundPly LR M25 Acoustic Ceiling Panels

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Product Guide Specification

Architectural Specifications, Section Phenolic Lockers

RAY-CORE Structural Insulated Roof and Wall Panels

A. Access doors and frames are part of an access door and frame allowance.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION GYPSUM BOARD ASSEMBLIES

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric

SECTION GYPSUM BOARD

A. Product Data: For each type of product, including panel products, high-pressure decorative laminate, adhesive for bonding plastic laminate.

WOOD FLOORING WOOD FLOORING

Guideline Specifications

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

by Rollfab Metal Products

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

Corium Brick Rainscreen System Specifications

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Rev. 07 8/15 Please Read Disclaimers:

ACOUSTICAL WALL TREATMENT SECTION 09840

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

SECTION 07530CP EPDM MEMBRANE ROOFING

3000 SERIES POCKET DOOR

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

SECTION EXTERIOR GRILLS AND SCREENS

SECTION PLASTER TRIM AND ACCESSORIES

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION CRC575 UNITARY CLEANROOM WALL SYSTEM STUDLESS CLEANROOMWALL SYSTEM ME175 3-IN-1 CLEANROOM WALL SYSTEM

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

FORMICA SOLID SURFACING BY FORMICA GROUP / FABRICATIONS 3-PART TECHNICAL SPECIFICATION SECTION ( )

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION ACOUSTICAL PANEL CEILINGS

Product Guide Specification

SECTION PRE-ENGINEERED BUILDING INSULATION

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

TILE TILE

SECTION ALUMINUM STORM WINDOWS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION DECORATIVE STAINLESS STEEL DRAINS AND GRATES

(Project Location) (your firm's name)

Gold Bond BRAND Gypsum Sheathing

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

Section Wood Grille Ceiling Panels

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SPECIFICATION GUIDELINE

SECTION EXPANSION CONTROL

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

LUX Specifications. Section S - Preformed Steel Siding

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

Transcription:

SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware and trim systems for installation directly to studs or solid substrate. 1. Hardware: Steel Vertical Posts, Horizontal Rails, and fixing hardware 2. Panels: a. Real Wood Veneers AA Architectural Veneer laminated to wood fiber substrate with balancing sheet. b. High Pressure Laminate adhered to wood fiber substrate and having a balancing backer sheet. c. Real Wood Veneers Wood Glass d. Phenolic with brown core e. CompactWood real wood phenolic B. Products Not Furnished or Installed under This Section: 1. Wood Veneer casework. 2. Drywall or gypsum board. 3. Screws to attach frame to wall/substrate 1.2 RELATED SECTIONS A. Section [ ] - Wood [Metal] Stud Framing B. Section [ ] - Custom Cabinets C. Section [ ] - Solid Wood Paneling D. Section [ ] - Gypsum Wallboard. E. Section [ ] - Painting & Transparent Finishes. F. Section [ ] - Resilient Base. 1.3 REFERENCES A. American Society for Testing and Materials: Standard Specifications (ASTM) 1. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials. American Architectural Millwork (AAM) 09 7710-1

B. Architectural Woodwork Standards as published by the Architectural Woodwork Institute, the Architectural Woodwork Manufacturers Association of Canada, and the Woodwork Institute. 1. Architectural Woodwork Standards - Edition 1. 1.4 SUBMITTALS A. Product Data: Submit sufficient manufacturer's data to indicate compliance with these specifications, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. B. Shop Drawings: Submit elevations of each wall showing location of paneling and trim members with respect to all discontinuities in the wall elevation. C. Selection Samples: Submit manufacturer s standard color and pattern selection samples representing manufacturer's full range of available colors and patterns. D. Samples for Verification: Submit sample for each component and for each exposed finish required, prepared on samples of size indicated below complete with exposed molding and trim samples. Sample to indicate type, finish, and color specified. 1. Phenolic: Submit 6 (154mm) by 10 (254mm) section of panel for each panel selected indicating the color, texture, and pattern required.. 2. High Pressure Laminate: Submit 6 (154mm) by 10 (254mm) samples of each type and color. 3. Real Wood Veneers Wood Veneer: Submit sample sets of [each] wood veneer with stain color and finish required. Sample size approximately 6 (154mm) by 10 (254mm). Sample sets to show the full range of normal color and texture variations expected. 4. Glass: Submit sample 6 x 6 for each pattern selected. E. Manufacturers Material Safety Data Sheets (MSDS) for adhesives, sealants and other pertinent materials prior to their delivery to the site. F. Maintenance Instructions 1.5 QUALITY ASSURANCE A. Conform to building code requirements for interior finish for smoke and flame spread requirements as tested in accordance with: 1. ASTM E 84 (Method of test for surface burning characteristics of building Materials) 2. Required Rating Class [A.] [C.] 1.6 DELIVERY, STORAGE AND HANDLING A. Deliver panels and associated materials factory packaged on strong pallets and properly packaged or protected. 1. Upon delivery carefully inspect all cartons, packages, pallets and protective wrap for damage or material shortage. Only commence installation when all materials have been American Architectural Millwork (AAM) 09 7710-2

received in perfect condition. Do NOT commence installation if there is a short shipment or damaged component. 2. Open and inspect suspect packages, cartons or wrapped pallets for damage. 3. Contact shipper immediately to report any damaged or missing materials. 4. Contact AAM immediately to report any damaged or missing materials, but within 48 hours of receipt. 5. Contact AAM with any questions, problems or concerns. B. Store products in manufacturer's packaging until ready for installation. 1. Maintain plastic or other protective wrap in place during on site handling until ready for installation. 2. Keep panels clean and do not stack panels after removal of protection. C. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. 1.7 PROJECT CONDITIONS A. Wood composite panels are subject to the effects of humidity and temperature. Do not use in kitchens or other high humidity areas. B. Partition walls are to be finished and the building completely closed. Walls shall be thoroughly dry and concrete cured and dry before starting installation. C. HVAC system must be operable and installation area must be balanced to normal operating conditions. D. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. To ensure product performance, a temperature range of 60-80 F (16 C-27 C) and a humidity range of 35-55% must be maintained during storage, installation and product life cycle. Do not install products under environmental conditions outside manufacturer's absolute limits. 1.8 COORDINATION AND SEQUENCING A. Except as specified by the architect and approved shop drawings, it s recommended to locate trim members so that panel lines coordinate with doors, headers, jambs and other discontinuities in a wall. B. Vapor barrier shall be used on exterior walls behind backing to discourage warping. 1.9 WARRANTY A. Standard Warranty: All products shall be warranted to be free from defects for a period of 30 days after installation. American Architectural Millwork (AAM) 09 7710-3

PART 2 - PRODUCTS 2.1 ACCEPTABLE PRODUCT A. American Architectural Millwork; 2825 Commerce Parkway, North Port, FL 34289 TEL: 1.855.295.2206 Email: pwest@millworkusa.com www.millworkusa.com B. Product: Façade Architectural Wall Panel System 2.2 HARDWARE A. Vertical Main Rail and Horizontal Cross Rail framing. 1. VMR - Vertical Main Rail, to create detailed reveals. Furnished in full 10-0 (3.0m) lengths. 2. HCR - Horizontal Cross Rail, to create detailed reveals. Furnished in full 9-0 (2.750m) lengths. 3. PSB Panel Secure Bar, on which panels will be secured. B. Panel Fixings 1. PC1 Panel Clip which panels are attached will be secured. 2.3 PANELS Panel Configuration: 1. Face dimensions: [Nominal 24 (610mm) wide x 24 (610mm) high.] [As indicated on the drawings]. 2. Panel thickness ¾ / ½ (19mm/ 13mm) thick as indicated on drawings B. Wood Fiber Substrate: 1. Medium density wood fiberboard conforming to ANSI A208.2, industrial-grade MDF or other wood fiber substrates having not less than 75% recycled wood waste 2. Medium density wood fiberboard conforming to ANSI A208.2, industrial-grade MDF and having No-Added Formaldehyde. C. Phenolic Panels - Solid Phenolic panels with brown core as manufactured by [FORMICA/WILSONART/ARPA/ABET/NEVAMAR] 1. Color and Pattern: [As selected by D. Metal Panels thin gauge metal sheet, laminated to wood fiber substrate. 1. Edges - Square, and sealed, to provide a black edge. 2. Color and Pattern: [As selected by 3. Grain direction: [Vertical.] [Horizontal.] E. Stone Panels Genuine thin stone veneer laminated to honeycomb aluminum substrate, or wood fiber substrate (MDF) for Slate finishes. American Architectural Millwork (AAM) 09 7710-4

1. Edges Square cut. 2. Color and Pattern: [As selected by 3. Grain direction: Random. 4. Pattern match: Random. F. Wood Veneer Panels: Real Wood Veneers AA Architectural grade wood veneer laminated to wood fiber substrate, and coated with furniture grade catalyzed finish as protective topcoats. 1. Edges Square cut and sealed. 2. Balancing Backer: Gator Backer 3. Veneer Face: 0.010" (0.25mm) to 0.015" (0.38mm) with a catalyzed finish of approximately 0.003" (0.08mm). 4. Species and Cut - : [As selected by Architect from manufacturer's selection.] a. Grain direction: [Vertical] [Horizontal]. 5. [Wood veneer stained color to match submission.][natural finish with clear topcoat.] G. High Pressure Laminate: Vertical grade high pressure plastic laminate adhered to wood fiber substrate. 1. Edges - Square, and sealed, to provide a black edge. 2. Balancing Backer: Kraft paper that does not contribute to or pose an unusual additional fire hazard. 3. Color and Pattern: [As selected by 2.4 ADHESIVES A. Faces applied with PVA adhesive or Time Bond Contact 2.5 FABRICATION A. All framing, panels, hardware and accessories shall be factory finished and ready to install except for field fabrication as required by jobsite and perimeter conditions. 1. Refinish field cut panel edges in accordance with manufacturer s instruction before installation. 2. For all cut-outs, drill corners for a minimum 1/8 radius. PART 3 - EXECUTION 3.1 EXAMINATION A. Installer's Examination: Examine conditions under which construction activities of this section are to be performed. Submit written notification to Architect and system manufacturer if such conditions are unacceptable. Beginning erection constitutes installer's acceptance of conditions. 1. Verify that a vapor barrier has been provided on exterior walls behind backing to prevent warping. American Architectural Millwork (AAM) 09 7710-5

2. Verify backing panels are smooth, solid, and flat. All drywall joints are to be taped and finished. 3. Verify that walls are primed before installation begins. 4. Verify mechanical, electrical, and building service and/or items affecting work of this section are placed and ready to receive this work. 5. Verify that stud spacing does not exceed 24 (600mm) on-center. B. Structural walls are to be finished, with building completely closed. Walls shall be thoroughly dry before starting installation. 3.2 PREPARATION A. Conditioning: Panels must be allowed to acclimate to a balanced environment in the installation location for 72 hours prior to installation. B. Protect existing surfaces with drop cloths. C. Except as directed by the architectural drawings, before installing, examine panels and arrange to achieve best combination of color, pattern, texture and grain. For book matched panels follow the sequence provided by manufacturer. 3.3 INSTALLATION A. Install all materials in strict accordance with the manufacturer s installation instructions with hardware straight, plumb, and level. 1. Anchor units rigidly and securely in place. 2. Cut sheets to meet existing supports. B. Fasten vertical and trim using #6 trim-head screws anchored into a stud or other solid substrate at 16" (40.64cm) centers. Where necessary countersink for the screw head to seat flush with the flange. C. Avoid contamination of the panel faces with adhesives, solvents or cleaners during installation. 3.4 CLEANING AND PROTECTION A. Clean and remove dust and other foreign matter from panel and framing surfaces. Clean finishes in accordance with manufacturer's instructions. END OF SECTION 09 7710 American Architectural Millwork (AAM) 09 7710-6