Multi-Institutional Academic Health Science & Research Center Evansville, IN

Similar documents
A. Product Data: For each type of product, including panel products, high-pressure decorative laminate, adhesive for bonding plastic laminate.

A. Section includes interior woodwork for the following applications:

Hobbs Architects, P.A. 159 West Salisbury Street P.O. Box voice

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

SECTION LINEAR WOOD CEILINGS

SECTION STILE AND RAIL WOOD DOORS

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

A. Product Data: For each type of process and factory-fabricated product.

1.3 REFERENCE STANDARDS

Product Guide Specification

FORMICA SOLID SURFACING BY FORMICA GROUP / FABRICATIONS 3-PART TECHNICAL SPECIFICATION SECTION ( )

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION EXTERIOR GRILLS AND SCREENS

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

A. Access doors and frames are part of an access door and frame allowance.

Section SoundPly LR M25 Acoustic Ceiling Panels

by Rollfab Metal Products

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION RESILIENT SHEET FLOORING

SECTION EXPANSION CONTROL

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

ACOUSTICAL WALL TREATMENT SECTION 09840

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Specifications for FL-100 Soffit Panel

SECTION ACOUSTICAL PANEL CEILINGS

Section Wood Grille Ceiling Panels

PRODUCT SPECIFICATIONS

SECTION METAL FLOOR PLATE STAIRS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Guideline Specifications

HPL CSI 3-PART SPECIFICATION FORM

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION COLD-FORMED METAL FRAMING

PIPE AND TUBE RAILINGS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

University Apartments on Brooklyn PROJECT MANUAL

SECTION PLATE CONNECTED WOOD TRUSSES

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

CSI GUIDE Countertops

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

SECTION HVAC GRAVITY VENTILATORS

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION


SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

Section GYPSUM DRYWALL

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION CLIMBING WALLS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1. Division 09 Section "Rough Carpentry."

Section PANEL SIGNAGE

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Page 1 of 5

WOOD FLOORING WOOD FLOORING

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION PRE-ENGINEERED BUILDING INSULATION

Corium Brick Rainscreen System Specifications

On-Call General Contractor Specifications University of Maryland College Park June 2013

Division 11 - Equipment Section 11401

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION ACCORDION FOLDING PARTITIONS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

SECTION BRICK MASONRY ASSEMBLIES

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Architectural Specifications, Section Phenolic Lockers

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION EPOXY TERRAZZO

EDGEWATER, FLORIDA JUNE 14, 2010

Attachment A-Flagpole(s) Specifications

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Transcription:

SECTION 06 4216 - FLUSH WOOD PANELING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Flush wood paneling. 2. Wood furring, blocking, shims, and hanging strips for installing flush wood paneling that is not concealed within other construction. 3. Shop finishing of flush wood paneling. B. Related Requirements: 1. Section 057000 "Decorative Metal" for metal reveals at wood paneling. 2. Section 061053 "Miscellaneous Rough Carpentry" for wood furring, blocking, shims, and hanging strips required for installing paneling that is concealed within other construction before paneling installation. 3. Section 09 8433 Sound Absorbing Wall Units for sound absorbing wood panels 1.3 COORDINATION A. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of Work specified in other Sections to ensure that paneling can be installed as indicated. 1.4 PREINSTALLATION MEETINGS A. Pre-installation Conference: Conduct conference at Project site. 1.5 ACTION SUBMITTALS A. Product Data: For each type of product. 1. Include data for fire-retardant treatment from chemical-treatment manufacturer and certification by treating plant that treated materials comply with requirements. B. Sustainable Design Submittals: 1. Product Certificates for Credit MR 5: For products and materials required to comply with requirements for regional materials, certificates indicating location of material FLUSH WOOD PANELING 06 4216-1

manufacturer and point of extraction, harvest, or recovery for each raw material. Include statement indicating distance to Project, cost for each regional material, and fraction by weight that is considered regional. 2. Certificates for Credit MR 6: Chain-of-custody certificates indicating that composite wood products comply with forest certification requirements. Include documentation that manufacturer is certified for chain of custody by an FSC-accredited certification body. Include statement indicating cost for each certified wood product. 3. Product Data for Credit IEQ 4.1: For adhesives and glues used at Project site, documentation including printed statement of VOC content. 4. Product Data for Credit IEQ 4.4: For composite wood products, documentation indicating that product contains no urea formaldehyde. 5. Laboratory Test Reports for Credit IEQ 4.1: For adhesives, documentation indicating that products comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." 6. Laboratory Test Reports for Credit IEQ 4.4: For composite wood products, documentation indicating that products comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." C. Shop Drawings: For flush wood paneling. 1. Include plans, elevations, sections, and attachment details. 2. Show details full size. 3. Show locations and sizes of furring and blocking, including concealed blocking specified in other Sections. 4. For paneling produced from premanufactured sets, show finished panel sizes, set numbers, sequence numbers within sets, and method of cutting panels to produce indicated sizes. 5. For paneling veneered in fabrication shop, show veneer leaves with dimensions, grain direction, exposed face, and identification numbers indicating the flitch and sequence within the flitch for each leaf. 6. Apply AWI Quality Certification Program label to Shop Drawings. D. Samples: For each exposed product and for each color and finish specified, in manufacturer's or fabricator's standard size. E. Samples for Initial Selection: For each type of exposed finish. F. Samples for Verification: For the following: 1. Lumber for Transparent Finish: Not less than 5 inches (125 mm) wide by 12 inches (300 mm) long, for each species and cut, finished on one side and one edge. 2. Veneer Leaves: Representative of and selected from flitches to be used for transparentfinished paneling. 3. Veneer-Faced Panel Products for Transparent Finish: 8 by 10 inches (200 by 250 mm), for each species and cut. Include at least one face-veneer seam and finish as specified. 1.6 INFORMATIONAL SUBMITTALS A. Qualification Data: For Installer. FLUSH WOOD PANELING 06 4216-2

B. Product Certificates: For each type of product. C. Quality Standard Compliance Certificates: AWI Quality Certification Program. D. Evaluation Reports: For fire-retardant-treated materials, from ICC-ES. 1.7 QUALITY ASSURANCE A. Fabricator Qualifications: Shop that employs skilled workers who custom-fabricate products similar to those required for this Project and whose products have a record of successful inservice performance. 1. Shop Certification: AWI's Quality Certification Program accredited participant. B. Installer Qualifications: AWI's Quality Certification Program accredited participant. C. Mockups: Build mockups to verify selections made under Sample submittals, to demonstrate aesthetic effects, and to set quality standards for materials and execution. 1. Build mockups of typical paneling as shown on Drawings. 2. Subject to compliance with requirements, approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion. 1.8 DELIVERY, STORAGE, AND HANDLING A. Do not deliver paneling until painting and similar operations that might damage paneling have been completed in installation areas. Store paneling in installation areas or in areas where environmental conditions comply with requirements specified in "Field Conditions" Article. 1.9 FIELD CONDITIONS A. Environmental Limitations: Do not deliver or install paneling until building is enclosed, wet-work is complete, and HVAC system is operating and will maintain temperature and relative humidity at levels planned for building occupants during the remainder of the construction period. B. Environmental Limitations: Do not deliver or install paneling until building is enclosed, wet-work is complete, and HVAC system is operating and will maintain temperature between 60 and 90 deg F (16 and 32 deg C) and relative humidity between 25 and 55 percent during the remainder of the construction period. C. Field Measurements: Where paneling is indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the Work. 1. Locate concealed framing, blocking, and reinforcements that support paneling by field measurements before being enclosed/concealed by construction and indicate measurements on Shop Drawings. FLUSH WOOD PANELING 06 4216-3

D. Established Dimensions: Where paneling is indicated to fit to other construction, establish dimensions for areas where woodwork is to fit. Provide allowance for trimming at site, and coordinate construction to ensure that actual dimensions correspond to established dimensions. PART 2 - PRODUCTS 2.1 PANELING FABRICATORS A. Source Limitations: Engage a qualified woodworking firm to assume undivided responsibility for production of paneling. B. Fabricators: Subject to compliance with requirements, available fabricators offering products that may be incorporated into the Work include, but are not limited to, the following: 1. Legere Woodworking, 80 Darling Drive, P.O. BOX 1527, Avon, CT 2.2 PANELING, GENERAL A. Quality Standard: Unless otherwise indicated, comply with the "Architectural Woodwork Standards" for grades of flush wood paneling (wood-veneer wall surfacing) indicated for construction, finishes, installation, and other requirements. 1. Provide inspections of fabrication and installation together with labels and certificates from AWI certification program indicating that woodwork complies with requirements of grades specified. 2. The Contract Documents contain requirements that are more stringent than the referenced woodwork quality standard. Comply with requirements of Contract Documents in addition to those of the referenced quality standard. B. Regional Materials: The following wood products shall be manufactured within 500 miles (800 km) of Project site from materials that have been extracted, harvested, or recovered, as well as manufactured, within 500 miles (800 km) of Project site. 2.3 FLUSH WOOD PANELING (WOOD-VENEER WALL SURFACING) A. Grade: Premium. B. Certified Wood: The following wood products shall be produced from wood obtained from forests certified by an FSC-accredited certification body to comply with FSC STD-01-001, "FSC Principles and Criteria for Forest Stewardship": C. Wood Species and Cut: White maple, Clear D. Panel-Matching Method: 1. No matching is required between adjacent panels. Select and arrange panels for similarity of grain pattern and color between adjacent panels. FLUSH WOOD PANELING 06 4216-4

E. Panel Core Construction: Hardwood veneer-core plywood or Fire-retardant particleboard or fire-retardant MDF as noted on drawings. 1. Thickness: 3/4 inch (19 mm) or as indicated on Drawings. F. Exposed Panel Edges: Inset solid-wood or wood-veneer matching faces. G. Panel Reveals: Stainless-steel sheet or Stainless-steel channels, 1 by 1 by 1/16 inch (25.4 by 25.4 by 1.6 mm) thick. H. Fire-Retardant-Treated Paneling: Panels shall consist of wood-veneer and fire-retardant particleboard or fire-retardant, medium-density fiberboard (MDF). Panels shall have a flamespread index of 75 or less and a smoke-developed index of 450 or less per ASTM E 84, and be listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction. I. Assemble panels by gluing and concealed fastening. 2.4 MATERIALS A. Materials, General: Provide materials that comply with requirements of referenced quality standard for each quality grade specified unless otherwise indicated. B. Wood Moisture Content: 5 to 10 percent. C. Composite Wood and Agrifiber Products: Provide materials that comply with requirements of referenced quality standard for each quality grade specified unless otherwise indicated. 1. Particleboard: Straw-based particleboard complying with requirements in ANSI A208.1, Grade M-2, except for density. a. Acceptable Product: MICROSTRAND WHEAT straw-based particle board as manufactured by Environ Biocomposites Manufacturing, LLC; Tele: (800) 324-8187. 2. Medium-Density Fiberboard: ANSI A208.2, Grade MD, made with binder containing no urea formaldehyde. a. Acceptable Product: SierraPine Medite II, Tele: (800)676-3339. 2.5 FIRE-RETARDANT-TREATED MATERIALS A. Fire-Retardant-Treated Materials, General: Where fire-retardant-treated materials are indicated, use materials that are acceptable to authorities having jurisdiction and with fire-test-response characteristics specified as determined by testing identical products per test method indicated by a qualified testing agency. 1. Use treated materials that comply with requirements of referenced quality standard. Do not use materials that are warped, discolored, or otherwise defective. FLUSH WOOD PANELING 06 4216-5

2. Use fire-retardant-treatment formulations that do not bleed through or otherwise adversely affect finishes. Do not use colorants to distinguish treated materials from untreated materials. 3. Identify fire-retardant-treated materials with appropriate classification marking of qualified testing agency in the form of removable paper label or imprint on surfaces that will be concealed from view after installation. B. Fire-Retardant-Treated Lumber and Plywood: Products with a flame-spread index of 25 or less when tested according to ASTM E 84, with no evidence of significant progressive combustion when the test is extended an additional 20 minutes, and with the flame front not extending more than 10.5 feet (3.2 m) beyond the centerline of the burners at any time during the test. 1. Kiln-dry lumber and plywood after treatment to a maximum moisture content of 19 and 15 percent, respectively. 2. For items indicated to receive a stained or natural finish, use organic resin chemical formulation. 3. Mill lumber after treatment within limits set for wood removal that do not affect listed firetest-response characteristics, using a woodworking shop certified by testing and inspecting agency. 4. Mill lumber before treatment and implement procedures during treatment and drying processes that prevent lumber from warping and developing discolorations from drying sticks or other causes, marring, and other defects affecting appearance of paneling. C. Fire-Retardant Particleboard: Made from softwood particles and fire-retardant chemicals mixed together at time of panel manufacture to achieve flame-spread index of 25 or less and smokedeveloped index of 25 or less per ASTM E 84. 1. For panels 3/4 inch (19 mm) thick and less, comply with ANSI A208.1 for Grade M-2 except for the following minimum properties: modulus of rupture, 1600 psi (11 MPa); modulus of elasticity, 300,000 psi (2070 MPa); internal bond, 80 psi (550 kpa); and screw-holding capacity on face and edge, 250 and 225 lbf (1100 and 1000 N), respectively. D. Fire-Retardant Fiberboard: MDF panels complying with ANSI A208.2, made from softwood fibers, synthetic resins, and fire-retardant chemicals mixed together at time of panel manufacture to achieve flame-spread index of 25 or less and smoke-developed index of 200 or less per ASTM E 84. 2.6 INSTALLATION MATERIALS A. Furring, Blocking, Shims, and Hanging Strips: Softwood or hardwood lumber, kiln-dried to less than 15 percent moisture content. B. Anchors: Select material, type, size, and finish required for each substrate for secure anchorage. Provide metal expansion sleeves or expansion bolts for post-installed anchors. Use nonferrous-metal or hot-dip galvanized anchors and inserts at inside face of exterior walls. C. Installation Adhesive: Product recommended by panel fabricator for each substrate for secure anchorage. FLUSH WOOD PANELING 06 4216-6

2.7 FABRICATION A. Sand fire-retardant-treated wood lightly to remove raised grain on exposed surfaces before fabrication. B. Arrange paneling in shop or other suitable space in proposed sequence for examination by Architect. Mark units with temporary sequence numbers to indicate position in proposed layout. 1. Lay out one elevation at a time if approved by Architect. 2. Notify Architect seven days in advance of the date and time when layout will be available for viewing. 3. Provide lighting of similar type and level as that of final installation for viewing layout unless otherwise approved by Architect. 4. Rearrange paneling as directed by Architect until layout is approved. 5. Do not trim end units and other nonmodular-size units to less than modular size until after Architect's approval of layout. Indicate trimming by masking edges of units with nonmarking material. 6. Obtain Architect's approval of layout before start of assembly. Mark units and Shop Drawings with assembly sequence numbers based on approved layout. C. Complete fabrication, including assembly, to maximum extent possible, before shipment to Project site. Disassemble components only as necessary for shipment and installation. Where necessary for fitting at site, provide ample allowance for scribing, trimming, and fitting. 1. Notify Architect seven days in advance of the dates and times paneling fabrication will be complete. D. Shop cut openings, to maximum extent possible, to receive hardware, appliances, plumbing fixtures, electrical work, and similar items. Locate openings accurately and use templates or roughing-in diagrams to produce accurately sized and shaped openings. Sand edges of cutouts to remove splinters and burrs. 2.8 SHOP FINISHING A. General: Finish paneling at fabrication shop as specified in this Section. Defer only final touchup, cleaning, and polishing until after installation. B. Preparation for Finishing: Comply with referenced quality standard for sanding, filling countersunk fasteners, sealing concealed surfaces, and similar preparations for finishing paneling, as applicable to each unit of work. 1. Backpriming: Apply two coats of sealer or primer, compatible with finish coats, to concealed surfaces of paneling. C. Transparent Finish: 1. Grade: Same as item to be finished. 2. Finish: System - 11, catalyzed polyurethane. 3. Wash Coat for Closed-Grain Woods: Apply wash-coat sealer to woodwork made from closed-grain wood before staining and finishing. 4. Staining: Match Architect's sample. 5. Sheen: Satin, 31-45 gloss units measured on 60-degree gloss meter per ASTM D 523. Match Architect's sample. FLUSH WOOD PANELING 06 4216-7

PART 3 - EXECUTION 3.1 PREPARATION A. Before installation, condition paneling to humidity conditions in installation areas. B. Before installing paneling, examine shop-fabricated work for completion and complete work as required, including removal of packing and back-priming. 3.2 INSTALLATION A. Grade: Install paneling to comply with quality standard grade of paneling to be installed. B. Install paneling level, plumb, true in line, and without distortion. Shim as required with concealed shims. Install level and plumb to a tolerance of 1/8 inch in 96 inches (3 mm in 2400 mm). Install with no more than 1/16 inch in 96-inch (1.6 mm in 2400-mm) vertical cup or bow and 1/8 inch in 96-inch (3 mm in 2400-mm) horizontal variation from a true plane. 1. For flush paneling with revealed joints, install with variations in reveal width, alignment of top and bottom edges, and flushness between adjacent panels not exceeding 1/32 inch (0.8 mm). C. Anchor paneling to supporting substrate with concealed panel-hanger clips. 1. Do not use face fastening unless otherwise indicated. D. Complete finishing work specified in this Section to extent not completed at shop or before installation of paneling. Fill nail holes with matching filler where exposed. 1. Apply specified finish coats, including stains and paste fillers if any, to exposed surfaces where only sealer/prime coats are shop applied. 3.3 ADJUSTING AND CLEANING A. Repair damaged and defective paneling, where possible, to eliminate defects. Where not possible to repair, replace paneling. Adjust for uniform appearance. B. Clean paneling on exposed surfaces. Touch up shop-applied finishes to restore damaged or soiled areas. END OF SECTION 06 4216 FLUSH WOOD PANELING 06 4216-8