The Westinghouse AP1000 : Passive, Proven Technology to Meet European Energy Demands

Similar documents
The Westinghouse Advanced Passive Pressurized Water Reactor, AP1000 TM. Roger Schène Director,Engineering Services

Westinghouse Small Modular Reactor. Passive Safety System Response to Postulated Events

AP1000 European 15. Accident Analysis Design Control Document

AP1000: The PWR Revisited

Post-Fukushima Assessment of the AP1000 Plant

Nuclear Power A Journey of Continuous Improvement

NPP Simulators Workshop for Education - Passive PWR NPP & Simulator Overview

Westinghouse AP1000. Reactor

Westinghouse s plant for the Nuclear Renaissance : AP1000. AP1000 Advanced Passive Plant

NUCLEAR POWER NEW NUCLEAR POWER PLANTS IN 2012

Evaluation of AP1000 Containment Hydrogen Control Strategies for Post- Fukushima Lessons Learned

Preliminary Lessons Learned from the Fukushima Daiichi Accident for Advanced Nuclear Power Plant Technology Development

AP1000 European 19. Probabilistic Risk Assessment Design Control Document

The ESBWR an advanced Passive LWR

Nuclear Power Plant Safety Basics. Construction Principles and Safety Features on the Nuclear Power Plant Level

SMR/1848-T03. Course on Natural Circulation Phenomena and Modelling in Water-Cooled Nuclear Reactors June 2007

HPR1000: ADVANCED PWR WITH ACTIVE AND PASSIVE SAFETY FEATURES

Small Modular Reactors: A Call for Action

NSSS Design (Ex: PWR) Reactor Coolant System (RCS)

The Westinghouse AP1000 Advanced Nuclear Plant Plant description

Risks Associated with Shutdown in PWRs

ACR-1000: ENHANCED RESPONSE TO SEVERE ACCIDENTS

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

Concepts and Features of ATMEA1 TM as the latest 1100 MWe-class 3-Loop PWR Plant

Westinghouse SMR & Nuclear Fuel Overview

Implementation of Lessons Learned from Fukushima Accident in CANDU Technology

Joint ICTP-IAEA Essential Knowledge Workshop on Deterministic Safety Analysis and Engineering Aspects Important to Safety. Trieste,12-23 October 2015

FUKUSHIMA DAIICHI BWR REACTOR SPRAY AND FEED WATER SYSTEMS EVALUATION FOR EARLY FAILURE Dean Wilkie

RELAP5/MOD3.2 INVESTIGATION OF A VVER-440 STEAM GENERATOR HEADER COVER LIFTING

DOE Small Modular Reactor Licensing Technical Support Program Overview for National Conference of State Legislatures June 19, 2014

PLANT VOGTLE UNITS 3 AND 4

NuScale SMR Technology

Next and Last Generation of Nuclear Power Plants Paul Howarth

Safety design approach for JSFR toward the realization of GEN-IV SFR

Verification of the MELCOR Code Against SCDAP/RELAP5 for Severe Accident Analysis

Safety enhancement of NPPs in China after Fukushima Accident

Westinghouse Holistic Approach to the Nuclear Fuel Cycle

APR1400 Safe, Reliable Technology

Isolation Condenser; water evaporation in the tank and steam into the air. Atmosphere (in Severe Accident Management, both P/S and M/S)

NuScale Power Modular and Scalable Reactor. NuScale. Integral Pressurized Water Reactor. Light Water. Light Water.

Controlled management of a severe accident

EPR: Steam Generator Tube Rupture analysis in Finland and in France

Design Safety Considerations for Water-cooled Small Modular Reactors As reported in IAEA-TECDOC-1785, published in March 2016

Advanced LWRs Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering

Passive Cooldown Performance of Integral Pressurized Water Reactor

Safety Provisions for the KLT-40S Reactor Plant

SEVERE ACCIDENT FEATURES OF THE ALTERNATIVE PLANT DESIGNS FOR NEW NUCLEAR POWER PLANTS IN FINLAND

Module 05 WWER/ VVER (Russian designed Pressurized Water Reactors)

Enhancement of Nuclear Safety

Safety Challenges for New Nuclear Power Plants

Main Steam & T/G Systems, Safety

AP1000 Nuclear Power Plant BAT Assessment

CAREM: AN INNOVATIVE-INTEGRATED PWR

LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

Safety Design Requirements and design concepts for SFR

CAREM Prototype Construction and Licensing Status

Status report Chinese Supercritical Water-Cooled Reactor (CSR1000)

5th Meeting of European MELCOR User Group (EMUG): Improved In-Vessel-Retention Model

Stress tests specifications Proposal by the WENRA Task Force 21 April 2011

Assessing and Managing Severe Accidents in Nuclear Power Plant

Small Modular Reactors (SMRs) What are they? Why are they cool?

The design features of the HTR-10

Regulatory Guide Monitoring the Effectiveness of Maintenance at Nuclear Power Plants

Research Article Extended Station Blackout Coping Capabilities of APR1400

Design of Traditional and Advanced CANDU Plants. Artur J. Faya Systems Engineering Division November 2003

NPP-Nuclear Island Design From conceptual design to Project execution

Status report Advanced Power Reactor (APR1000)

RELAP 5 ANALYSIS OF PACTEL PRIMARY-TO-SECONDARY LEAKAGE EXPERIMENT PSL-07

BARC BARC PASSIVE SYSTEMS RELIABILITY ANALYSIS USING THE METHODOLOGY APSRA. A.K. Nayak, PhD

CGN's Nuclear Energy Capabilities

Caroline Schlaseman. MPR Associates Inc.

RESULTS OF THE GRADUAL UPGRADING AT BOHUNICE WWER - 440/230 NPP

Nuclear Reactor Types. An Environment & Energy FactFile provided by the IEE. Nuclear Reactor Types

Safety Implication for Gen-IV SFR based on the Lesson Learned from the Fukushima Dai-ichi NPPs Accident. Ryodai NAKAI Japan Atomic Energy Agency

Shutdown and Cooldown of SEE-THRU Nuclear Power Plant for Student Performance. MP-SEE-THRU-02 Rev. 004

CANDU Safety #6 - Heat Removal Dr. V.G. Snell Director Safety & Licensing

SAFETY GUIDES. Deterministic Safety Assessment РР - 5/2010 ÀÃÅÍÖÈß ÇÀ ßÄÐÅÍÎ ÐÅÃÓËÈÐÀÍÅ BULGARIAN NUCLEAR REGULATORY AGENCY

Nuclear Service Valves

ANTICIPATED ANALYSIS OF FLAMANVILLE 3 EPR OPERATING LICENSE - STATUS AND INSIGHTS FROM LEVEL 1 PSA REVIEW

DRAFT REGULATORY GUIDE

INTEGRAL EFFECT NON-LOCA TEST RESULTS FOR THE INTEGRAL TYPE REACTOR SMPART-P USING THE VISTA FACILITY

Introduction to the 2015 Darlington NGS Probabilistic Safety Assessment. Carlos Lorencez and Robin Manley Ontario Power Generation August 2015

Post Fukushima actions in India. Mukesh Singhal, Chief Engineer, Reactor Safety & Analysis Directorate NPCIL

Dr.-Ing. Rainer Kaulbarsch, Gösgen Power Plant (CH) August, 26th, 2013, Vienna

Review of Generation III Reactors

Lessons Learned from Fukushima Daiichi Nuclear Power Station Accident and Consequent Safety Improvements

OPERATING EXPERIENCE REGARDING THERMAL FATIGUE OF UNISOLABLE PIPING CONNECTED TO PWR REACTOR COOLANT SYSTEMS

Design, Safety Technology and Operability Features of Advanced VVERs

UKEPR Issue 04

Nuclear Power Volume II - Nuclear Power Plants

ASTEC Model Development for the Severe Accident Progression in a Generic AP1000-Like

CLASSIFICATION OF SYSTEMS, STRUCTURES AND COMPONENTS OF A NUCLEAR FACILITY

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C SAFETY EVALUATION REPORT

DEVELOPMENT AND APPLICATION OF PROBABILISTIC SAFETY ASSESSMENT PSA IN DAYA BAY NUCLEAR POWER STATION

Status report 85 - VVER-1500 (V-448) (VVER-1500 (V-448))

A DYNAMIC ASSESSMENT OF AUXILIARY BUILDING CONTAMINATION AND FAILURE DUE TO A CYBER-INDUCED INTERFACING SYSTEM LOSS OF COOLANT ACCIDENT

Advanced Fuel CANDU Reactor. Technical Summary

United States Industry Perspectives on Implementation of Post-Fukushima Actions

ADPFISS-LP Ricerca Sistema Elettrico. Table of contents. Executive summary List of acronyms

Transcription:

BgNS TRANSACTIONS volume 20 number 2 (2015) pp. 83 87 The Westinghouse AP1000 : Passive, Proven Technology to Meet European Energy Demands N. Haspel Westinghouse Electric Germany GmbH, Dudenstraße 6, 68167 Mannheim, Germany Abstract. Even though several years ago nuclear power was merely considered to be an optimistic future assessment, the world-wide renaissance of nuclear power has become reality! The economical and climate-friendly nuclear power generation is internationally regarded to be in an evident upturn. The 435 nuclear power plants in operation worldwide are being modernized and the capacity is increased continuously. Furthermore, to date, 42 power plants are under construction, another 81 are already being applied for and or definitely planned. The global total net capacity out of nuclear power will increase accordingly in the upcoming years from currently 372 to more than 500 GWe, which presents an increase of more than one third. Westinghouse s contribution hereto is considerable: At the present time, 4 power plants of the series AP1000 are under construction. To begin with, 2 units each are under construction at the Chinese sites Sanmen and Haiyang, another 4 per site are being planned. In the USA, Westinghouse has been contracted with a Engineering, Procurement and Construction (EPC) project for a total of 4 power plant units at the Vogtle and V.C. Summer. Also in Europe, the plans to construct new plants are meanwhile very specific and many countries have formally established the marginal conditions for new nuclear projects. The AP1000, with its medium output capacity, is ideally positioned for many markets and can as a twin unit also cover large capacity demands. At the present time, Westinghouse, with its AP1000, participates in the so-called GDA (Generic Design Assessment) process in Great Britain, where the British regulatory authorities conduct an assessment and evaluation of the safety aspects of this plant design in a defined multilevel process. The successful conclusion of this process ultimately leads to a Design Acceptance Confirmation, which will basically make the construction of the plant in Great Britain possible. 1 Introduction Both the Utility Requirements Document (URD) and the European Utility Requirements (EUR) have the general approach of preserving the virtues of the operating plants when it comes to the power producing systems. But there is also a requirement for a simpler plant that is safer and costs less to construct. Both the EUR and URD anticipate and address specifically the advantages of passive safety features for reducing both construction cost and reliance on operator actions for the mitigation of design basis events. In fact, the expectation for a passive plant is to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action. This is substantially different than the 30 minute period for operator action specified for an evolutionary plant that uses active safety systems. The URD also expects that new plant designs offered to utilities will be complete plants, encompassing the entire plant up to its connection to the grid. In line with the URD and EUR requirements, the AP1000 passive design represents a significant improvement over conventional PWRs, and is developed around the fundamental design principles of increased safety, simplification and standardization [1-4]. 2 AP1000 Overview 2.1 Retaining the virtues of current operating plants The AP1000 plant is designed around a primary system configuration with the reactor pressure vessel, two steam generators and four reactor coolant pumps directly mounted in the steam generator lower head. The power producing primary system is a familiar one based on proven and reliable Westinghouse PWR features but with evolutionary improvements. The combination of decades of operating experience and the development of improved materials and better manufacturing techniques are expected to result in significant benefit with respect to plant safety, reliability and lifetime. Examples of these improvements are: The AP1000 reactor vessel is ring-forged, eliminating longitudinal welds and there are no circumferential welds in the high flux core region. These features combined with improved materials allow for a 60 year vessel life. The fuel design is closely based on the XL Robust Fuel Assembly design that has been operating in Doel, Tihange and South Texas; AP1000 is a registered trademark of Westinghouse Electric Company LLC in the United States and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. 1310 8727 2015 Bulgarian Nuclear Society 83

N. Haspel Figure 1. Modular construction allows activities in parallel standardization. The AP1000 primary system design makes use of seal-less reactor coolant pumps, eliminating the need for shaft seals and their complex support systems. The sealless RCPs require no oil lubrication system and are designed to be maintenance-free. Sealless motor pumps were used in the first generation of Westinghouse PWRs but, as the plants became larger with the second generation designs, they out-grew the capacity of that type of pump available at the time. Since then, sealless pump sizes have increased, enabling their application to power reactors once again. The quantity of Stellite has been minimized to reduce cobalt-60 production thus reducing plant dose rates. Multiple levels of defense-in-depth are aimed at accident mitigation resulting in a low core damage frequency. 2.2 Safety The over-arching design principle of the AP1000 with respect to nuclear safety is the use of simple, passive safety systems. These safety systems are dedicated to the mitigation of safety issues and are not required for normal operation. This approach is applicable to core cooling, containment cooling, spent fuel cooling, control room habitability, and the electrical power supply for I&C. The AP1000 passive safety systems use natural driving forces such as gravity and natural convection to address abnormal and/or accident conditions. These passive safety systems require no external or on-site AC power sources to function, and once actuated require no support systems to maintain their functionality for at least 72 hours. The passive systems require no pumps or other active component responses to perform functions after their initiation. They automatically establish and maintain reactor safe shutdown conditions. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. This provides the benefit of greatly reducing the dependency on operator actions to respond to an event. The AP1000 utilizes the inherent reliability of natural phenomena to simplify safety systems while enhancing safety. In addition to redundancy, the passive safety features also incorporate functional diversity based on Probabilistic Risk Assessment (PRA) insights [2]. Structures, systems and components critical to placing the reactor in a safe shutdown condition are protected within the steel containment vessel which is further surrounded by a substantial steel and concrete composite shield building. When AC power is available, the AP1000 passive systems can be supplemented with simple, active defense-in-depth systems and equipment. The active defense-in-depth systems use reliable and redundant active equipment, supported by the use of defense-in-depth standby diesels to facilitate their functions when offsite AC power is available or not. These simple, active structures, systems and components are optimized for their normal operating functions. The active systems provide investment protection and reduce the overall risk to the plant owner and the public by minimizing the demand on the passive safety features. While important to the safe normal operation of the plant, the active systems are not necessary for the safe shutdown of the reactor following a design basis accident. The multiple levels of defense provided by the active defense-in-depth systems and passive safety systems result in very low core damage and large release frequencies as calculated by the PRA [2]. 84

The Westinghouse AP1000 : Passive, Proven Technology to Meet European Energy Demands In addition, the AP1000 design has carefully evaluated and addressed severe accident phenomenon. A key AP1000 feature in dealing with a severe accident is invessel retention of a molten core. This feature provides a robust, reliable, simple means of preventing a molten core from breeching the reactor vessel, eliminating ex-vessel phenomena that could cause containment failure. References 2, 3 provide additional information on severe accident design features. 2.3 Simplification The principle of simplification is applied throughout the lifecycle of the AP1000 plant: Simpler design: The elimination or simplification of active systems as a result of the reliable passive safety systems and the evolutionary improvements included in the AP1000 design allows an overall simplification of the plant, a reduction of equipment and structures, and maximizes the certainty of delivery and schedule. Simpler construction: AP1000 has a highly developed construction plan to minimize the time and cost of construction. It is designed from the outset for modular and open top construction techniques. Modular construction allows activities to be run in parallel and it allows more activities to be performed in a controlled factory environment instead of in the field (Figure 1). Fewer safety related components: The passive safety systems result in fewer components which contribute to considerable savings in maintenance, testing & operation costs. The AP1000 standard plant design uses conservative, bounding site parameters (temperatures, wind velocities and seismic levels), achieves a very high level of safety and incorporates utility operational desires. As a result, it is a plant design that can be applied to different geographical regions around the world with varying regulatory standards and utility expectations without major changes which simplifies and standardizes construction, procurement, installation, testing, operator training, licensing and operation. 3 AP1000 Passive Safety Systems 3.1 Emergency core cooling system The Passive Core Cooling System (PXS), shown in Figure 2, protects the plant against all postulated events in the Reactor Coolant System (RCS) like leaks and ruptures of various sizes and locations. The PXS provides core residual heat removal, core reactivity control, safety injection and depressurization. Safety analyses (using U.S. Nuclear Regulatory Commission-approved codes) demonstrate the effectiveness of the PXS in protecting the core following all postulated design basis events. Even for breaks in the RCS as severe as one of the 20.0 cm (8 in) vessel injection lines, Figure 2. Passive core cooling system. there is no core uncovery. Following a double ended rupture of a main reactor coolant pipe, the PXS cools the reactor with ample margin to the peak clad temperature limit thus minimizing core damage and clad/steam reaction. The PXS uses three sources of water to ensure boration and maintain core cooling through safety injection. These injection sources include the core makeup tanks (CMTs), the accumulators, and the in-containment refueling water storage tank (IRWST). These injection sources, together with the containment recirculation flow paths, are directly connected to two nozzles on the reactor vessel so that no injection flow is spilled in case of larger breaks in the loop piping. They contain borated water which ensures RCS boration when the water is injected. There are two CMTs located inside the containment at an elevation above the reactor coolant loops. During normal operation, the CMTs are completely filled with cold borated water. The boron concentration of this water is somewhat higher than that of the water in the accumulators and the IRWST. The boration capability of these tanks provides adequate core shutdown margin following a steam line break and for all safe shutdown events. Each CMT is connected to the RCS by a normally closed discharge line which injects directly into the reactor vessel downcomer, and by a normally open pressure balance inlet line connected to an RCS cold leg. The CMT pressure balance lines enable the CMTs to inject borated water into the RCS at any RCS pressure. The CMTs are actuated by opening either one of two redundant, fail-open air operated valves that are located in parallel in the tank discharge lines. The two accumulators contain borated water and a compressed nitrogen cover to provide rapid injection following postulated large breaks in the RCS. Each accumulator discharge line contains two check valves in series, which isolate the accumulators from the RCS during normal plant operation. The accumulators will inject borated water 85

N. Haspel whenever the RCS pressure decreases to less than the accumulator cover gas pressure. Long-term injection water is provided by gravity from the IRWST, which is located in the containment above the RCS loop elevation. Normally, the IRWST is isolated from the RCS by squib valves and check valves. Since this tank is designed for atmospheric pressure, the RCS must be depressurized before IRWST injection can occur. Therefore, the RCS pressure is automatically reduced so that the head of water in the IRWST is higher than the RCS pressure. The depressurization is provided using four stages of automatic depressurization to permit a relatively slow, controlled RCS pressure reduction. The AP1000 containment is configured such that the water from the postulated break (including the PXS injection water) floods the lower portion of the containment to an elevation above the RCS loop piping. This water is returned to the reactor through two redundant and diverse containment recirculation paths. Each of the two recirculation paths contains one path with a squib valve backed up by a check valve and another path containing a different squib valve design backed up by a normally open motoroperated valve. Both the IRWST injection paths and the containment recirculation paths are protected by screens that prevent debris that could interfere with core cooling from being injected to the reactor. 3.2 Passive residual heat removal The PXS includes one passive residual heat removal heat exchanger (PRHR HX), illustrated in Figure 2 and Figure 3. The PRHR HX is able to remove core decay heat, even at full RCS pressure, and to cool the RCS to safe shutdown conditions following any event where the normal heat removal via the steam generators is unavailable; for example, a loss of feedwater event with failure to provide start-up feedwater. It satisfies the safety criteria for loss of feedwater, feedwater line breaks, and steam line breaks. The PRHR HX is submerged within the IRWST whose water inventory serves as the heat sink. The PRHR HX inlet line is connected to RCS loop 1 hot leg and the outlet line returns cooled reactor coolant to the steam generator cold side channel head which connects to the RCS cold legs. The HX is actuated by opening either one of two redundant, failopen air operated valves that are located in parallel in the HX outlet (return) line. Following PRHR HX actuation the IRWST water absorbs the core decay heat and RCS sensible heat. After almost two hours the IRWST water will begin to boil. Once boiling starts, steam is vented to the containment and will be condensed on the steel containment vessel by the passive containment cooling system and, after collection, drains by gravity back into the IRWST. The PRHR HX, the IRWST water inventory, and the PCS provide decay heat removal capability for an extended time with no operator action or AC power required. 3.3 Passive containment cooling system The PCS, also illustrated in Figure 3, provides the safetyrelated ultimate heat sink for the plant. The PCS cools the containment following any event which results in energy release into the containment so that containment design pressure is not exceeded and pressure inside containment is rapidly reduced. The steel containment vessel provides the heat transfer surface that removes heat from inside the containment and transfers it to the atmosphere. Heat is removed from the containment vessel by continuous, natural circulation of air. If required, the air cooling is supplemented by applying water onto the outside of the containment steel shell, where the water is heated and evaporates into the cooling air flow path. The water is provided from a tank located on top of the containment shield building and drains by gravity after opening either one of two, normally closed, fail-open air operated valves in parallel lines or by opening a diverse, battery powered motor operated valve in a third flow path. The PCS water storage tank located above the containment contains sufficient water for gravity draining for three days. After three days the AP1000 design includes additional onsite water storage and equipment to continue water application for additional four days. At last, after seven days air-cooling alone is sufficient to prevent containment over pressurization. 4 Conclusion Figure 3. Passive core cooling system. AP1000 is the safest and most economical nuclear power plant available in the worldwide commercial marketplace and offers to power generating companies an economical and climate-friendly power generation based on nuclear. Passive safety without the direct need of operator actions leads to safety concept which is self-reliant, self-contained and fail safe. This results in a high robustness also against extreme external events with a positive contribution to public perception. Modular and open-top construction techniques, combined to the overall simplification of the plant, results in simpler 86

The Westinghouse AP1000 : Passive, Proven Technology to Meet European Energy Demands construction and shorter construction schedule. Westinghouse has been working during the design development closely also with European utilities and organizations, mainly through the European Passive Plant (EPP) program, to ensure that European specific market needs and requirements are satisfied. These efforts culminate in a very successful EUR assessment and accounts to a licensability in European countries. Considering these advantages the AP1000 fits perfectly to a European strategy lowering the greenhouse gas emission with ambitious reduction objectives and supporting utilities to meet the need for safe, clean and reliable energy generation. References [1] WESTINGHOUSE ELECTRIC COMPANY, AP1000 Design Control Document, APP-GW-GL-700, Revision 19 [2] Scobel J.H. and Schulz T.L., Westinghouse Westinghouse AP1000 PRA Maturity, In: Proc. of International Congress on Advances in Nuclear Power Plants 05, Seoul, Korea, May 15-19, American Nuclear Society (2005) Paper 5672. [3] Scobel J.H., et al., Using Severe Accident Management to Address Phenomenological Uncertainties Related to Lower Plenum Debris Bed Chemistry and Mixing during AP1000 In-Vessel Retention (IVR) of Molten Core Debris, In: Proceedings of ICAPP 2011, Nice, France (May 2-5, 2011). [4] Cummins W.E., Vijuk R.P. and Schulz T.L., Westinghouse Westinghouse AP1000 Advanced Passive Plant, In: Proc. of International Congress on Advances in Nuclear Power Plants 05, Seoul, Korea, May 15-19, American Nuclear Society (2005) Paper 5670. 87