Installation Instructions. Suitable: Glued down carpets Parquet: adhesive remnants

Similar documents
Tufted and Woven Goods Direct Glue-Down

Installation Guide LVP Glue Down

DO-IT-YOURSELF SELF ADHESIVE PLANK INSTALLATION

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

RAUPEX SPEED SYSTEM Installation Guide

Installation Instruction

Tufted and Woven Goods Double-Stick

UNDERLAYMENT INSTALLATION INSTRUCTIONS

INSTALLATION GUIDELINES The following instructions shall be reviewed prior to installation. Shaw will not be responsible for improper installation.

IVC US Residential Installation Guide - Sheet Vinyl. Leading the Way

Commercial Resilient Sheet Flooring

ARTISAN INSTALLATION INSTRUCTIONS ROLLS - BOLON GREEN WELD

FlexLok Adhesive Tabs for Carpet Tile

ComforTech Cushioned Rubber Sheet Flooring

ARTISAN INSTALLATION INSTRUCTIONS ROLLS

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

Installation Guidance Note: Flotex Sheet

Carpet Tile & Plank Direct Glue Down

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

INSTALLATION INSTRUCTIONS FOR ARTISAN ROLL

PAGE 2. Acoustic White Underlay PAGE 3. Fibreboard. Comfort Gold & Silver Foam Underlay PAGE 4 5 PAGE 6. Timbertech Rubber Underlay PAGE 7-10

HYBRID. Pre-Laying Checks

BOLON BY YOU INSTALLATION INSTRUCTIONS ROLLS

CONTRACT PAGE 1 OF 5

IVC US Commercial Installation Guide - LVT. Leading the Way

Installation Guide. Please verify seaming layout against scope of work to ensure all areas have been covered.

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Tactile Pad Installation Guide. All Surfaces.

Product Width Thickness Installation direction Seam treatment. Taraflex Sport M Comfort Approximately mm + 5mm Same Heat Welded

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

BENTLEY ELEMENTS COLLECTION LVT

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

INSTALLATION INSTRUCTIONS FOR GERFLOR TARASAFE ULTRA VINYL SHEETGOODS

PURE INSTALLATION MANUAL

Chapter 4. Adhesives, tapes and sealants. Topics. 19 Adhesives, tapes and sealants. Notes. 4.4 Contact adhesives and double faced tapes 22

Installation Instructions for CushionBac Renew Tiles

The following instructions should be reviewed prior to installation. Shaw Industries will not be responsible for improper installation.

for the master tradesman Setcrete Product Guide

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

INSTALLATION BASICS FOR TUFTED BROADLOOM BACKING

INSTALLATION INSTRUCTIONS FOR WICANDERS HYDROCORK

POROUS (ABSORBENT) SUBFLOORS. (most wood subfloors and some concrete)

Triton DCI Decoupling Mat

INSTALLATION BASICS FOR TUFTED BROADLOOM BACKING

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION

Air and Vapor Barrier 3015

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

Updated 1/25/13. Supercedes all previous versions. Check website for updates. ASE PREPARATIO

INSTALLATION AND MAINTENANCE MANUAL

SPECIAL PROCEDURES INSTALLATION & WARRANTY

FLOORING FOR FLOOD-PRONE AREAS. Vinyl Flooring. Pros of Vinyl Flooring for Flood-Prone Areas

Page 1 of 5 PART 1 GENERAL

INSTALLATION INSTRUCTIONS

Infinity Modular/Infinity Modular RE Carpet Tile Installation Guidelines

WOODLOC 5G FLOAT-IN INSTALLATION INSTRUCTIONS

PRODUCT DATA SHEET Sika Level-315 F

MILLIKEN SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS.

Floor-covering with exclusive properties thanks to patented GERFLOR FIBRE TECHNOLOGY

noraplan norament nora Installation Guide norament flooring system

Amtico QuickStix LVF Installation

Screedmaster Ultimate

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Indoor Carpet Advertising System Primed White Opaque Base/Clear Velvet Overlaminate

ARDEX UI 720 FLEXBONE

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

Wallflowers RUBBER WALL BASE

Indoor Carpet Advertising

MANAAKI GUIDELINES. Creating amazing spaces

Installation Products

VINYL COMPOSITION TILE

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Superior Quality Flooring Installation Products for the Commercial Construction Industry

PRODUCT DATA SHEET SikaBond T55 (J)

9 RUBBER TRACK SURFACING (INDOOR APPLICATIONS) (FOR ALL SPORTFLEX, SUPER X AND MONDOTRACK PRODUCTS)

INSTALLATION INSTRUCTIONS

VELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d

TECHNICAL DATA SHEET SIKABOND-54 WOOD FLOOR 6KG (3pack=18KG)

STEGO WRAP CLASS C VAPOR RETARDER A STEGO INDUSTRIES, LLC INNOVATION VAPOR RETARDERS , VERSION: JAN 5, 2018

INSTALLATION INSTRUCTIONS LAMINATE

Installation and general maintenance instructions Design Floors Dryback

FiberFloor Glueless and Full Spread Installation Instructions

STACKED PERFORMANCE MONSTER ROLL

High viscous (thixotropic) elastic adhesive for wood flooring

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C).

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Construction. Low viscous (easy flowing) elastic adhesive for wood flooring. Product Description. Product Data

SUBSTRATES FOR WOOD FLOOR SETTING

COMMERCIAL RESILIENT INSTALLATION GUIDELINES

DeZign Glue Down Luxury Vinyl

Installation Instructions for SuperFast Hurricane

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

Application Instructions for Keystone Kool Deck on Existing Concrete

ARDEX DS 70 TM. Acoustic Mat

Transcription:

Installation Instructions Sigaway Dry Installation Method Using the old covering instead of tearing it out. For carpet Information regarding suitability Floor coverings Suitable existing sub-surfaces Suitable: Not guaranteed: Suitable: Not warranted: Glued down carpets Parquet: adhesive remnants Stone tiles: imitation profile Cushioned vinyl flooring with surface Jute backing Textile action backs (TR) Latex foam backs Carpet tiles with bitumen, jute, or PVC backs (exception: Flortex) Kugelgarn Glue-down carpets (must be structurally sound) Carpet runners with PVC-backs (e.g., dirt traps, Flotex) Synthetic action backs (SDR) Oriental carpet, carpet runners Cut and loop pile carpets with level patterns (telescoping) Carpet with adhesive repellent coatings structured patterns on the back (e.g., polyurethane PU) Needle punched carpets Woven New carpet must exceed the gauge and strength of the old carpet Coconut, sisal, cork NEODON (NEODUR Textil/TOP_BAC Needle punch Latex backings with high concentration gypsum Marble/natural stone floors: yellowing On-grade of below-grade floors which Sub-floors with 3 lb/1000 sft. moisture emissions Sub-surfaces containing bitumen or do not have a moisture barrier installed Plywood (prepared with film forming dispersion primer for dust resistance) of aluminum tri hydrate flame retardant. Subfloors with >3.0 lb/1000 sft. Moisture emissions Insulating coverings Chipboard or acrylic coated wood Filled sub-surfaces Preparing the sub-surface 1. The sub-floor or old floor covering must be dust free, level, smooth and even (prevent telegraphing), without cracks, and may not be brittle. 2. Old floor covering must be firmly glued to the subfloor in all areas and may not be loose. If the existing floor covering is damaged or worn in local areas, cut open, glue loose sections, repair with junk tile or floor covering of same gauge and density. Alternatively fill holes or cracks with gray Portland cement based troweled compound. Gypsum leveling compounds are not permissible (dust!). 3. Condition sub-floor, floor covering and Sigaway for at least 6-12 hrs. at >68 F (>18 C). 4. Residual moisture of subfloor. Same requirement as for direct glue-down with conventional adhesives <3.0 lb/1000 sf. 5. Sub-floors must be vacuum-clean, and must be dust, oil, and wax free. Normal stains (drink stains etc.) need not be cleaned. 6. General Installations should conform to the general requirements of applicable national standards (such as B.S. 5325, B.S. 8203; ASTM S 710; CRI C104 and CRI C105). Page 1 of 5

Installing the Sigaway Stick SUPERtape 7900 construction tape to the floor For the edge/wall areas, stick a strip of the double-sided SUPERtape 7900 construction tape (V) onto the covering sub-surface. At the seam locations (T1, T2), stick two strips next to each other. Only use plasticizer resistant SUPERtape 7900 construction tape. Lay the Sigaway Only remove the protective paper from the double-sided adhesive tape (V) in the area of the seam. Lay the Sigaway run by run with a 1 (2 cm) overlap in the running of working direction, and rub in well. Only lay as much Sigaway as the floor covering that will be laid on the same day. Roll out new carpet Temperature condition the floor covering to >68 F (18 C). Lay the carpet runs T1 and T2 on the Sigaway without tension, and match up roughly. Cut the edges of the carpet seams according to the manufacturers specification (seam edge cutter). When making a double cut, place a metal strip underneath. Never cut through the Sigaway. Sticking down the carpet run T1 Roll back the carpet to the middle in the direction of the run. Remove the SUPERtape 7900 construction tape protective paper. Pull the protective paper away from the Sigaway flat and straight up to the folded-back carpet (lower run first). Cut off the removed protective paper leaving a 4 (10 cm) balance and fold under the folded back covering to form a flap. Stack the protective paper together and pull up (to minimize) waste volume). Lay the first carpet run free from tension and bulges and rub in. Always pull the protective paper from the underlying Sigaway first. Page 2 of 5

Installing the Sigaway continued Sticking down the carpet run T1 Fold back the second half of the carpet and pull off the remaining protective paper with the aid of the flap. Lay the fitted carpet, rub in, and cut the edges to match. Finally, smooth in well The carpet being laid must be rolled in from the middle. Roll in the floor covering crosswise using a heavy roller. Tips & Tricks 1. Laying the Sigaway quickly 2 person procedure Unroll approx. 40 (1 metre) of Sigaway and align precisely The first person moves backwards with the Sigaway roll. The second person stands on the unrolled Sigaway run and rubs it in with a brush. 2. Matching patterns To match up the individual runs of carpet, fold back halfway along the seam. Pull off the protective paper from this area. Lay one side free from traction, tension and undulations, and rub in. Then lay the other side, and match the seam precisely, moving left and right from the middle Then Rub or roll in well 3. Carpets with rough backings Apply a strip of Contact 85 (carpet skirting tape) onto the Sigaway in the areas of the seam and the edges of the floor covering. This will increase the adhesive force with regard to the back of covering. Lay the carpet free of tension. Temperature condition the carpet runs. Page 3 of 5

Tips & Tricks continued 4. Water trick for carpets Use when laying seams/cutting and pushing in the floor covering under a radiator and so on: After pulling off the protective paper, and before laying the floor covering, Sigaway can be dampened in places using a wet sponge. The covering is then laid on the damp Sigaway. The adhesive force will thereby be neutralized for a few minutes. Once the water has evaporated, the covering will stick immediately. Then rub in the floor covering again. 5. Laying carpets tiles Remove the protective paper. Make the markings directly onto the Sigaway. With light sub-surfaces, make the markings directly onto the existing covering that will be covered over before rolling out the Sigaway. The markings can then be seen through the Sigaway material. When laying the tiles, only pull off as much protective paper from the Sigaway as is necessary at the moment in time. In order to ensure access to raised floors, individual tiles can be lifted together with the Sigaway at any time: to do this, run a carpet knife along the edge of the tiles and cut the Sigaway on the floor. Then lift the tiles together with the Sigaway. Each tile can be re-used together with the Sigaway. 6. Installing conductive carpet Limited to carpet or carpet tile with electrically conductive backing. First connect the individual Sigaway -electronic sheets with the supplied copper tape K, whereby the copper side must face downwards. Two or more grounding connections per area are recommended. Fold back the protective paper by 10 cm, lay the copper tape and connect to earth. Page 4 of 5

Limitations Do not use Sigaway on stairs or walls. Removal of a Sigaway installation at a later date can result in adhesive and flooring material residues on the old floor. This is likely if the flooring Sigaway is weak or has turned brittle, or if backings separate from the flooring. There is a possibility of chemical bond of migrated plasticizer from vinyl flooring through Sigaway to acrylic coated surfaces, such as wood. Sigaway is therefore not suited for use over original floor coverings that are intended to be re-used in their original condition. Laying temperature: + 18 C (>68 F), applicable to the floor, Sigaway and the covering. Sigaway is not suitable for outdoor use (e.g., artificial grass) When laying, never work with stretching equipment (toggle stretchers, etc.) Temperature condition the floor covering sufficiently in the room. The reuse-ability of any flooring that was installed with Sigaway and was subsequently removed is not warranted. Sigaway installations over subfloors with >3lb/1000 sft moisture emission are not warranted. Specific working conditions, unpredictability of sub floor conditions and the variety of different materials which may be installed will always require adequate trial installations by the customer for specific applications. These instructions are subject to revisions without prior notice due to new findings and practical experience. The installer should check with the Sigaway distributor for specific flooring types, subfloor conditions, and updated installation instructions prior to purchase and installation. The installer or project owner should check with the provider of the selected solid vinyl or cushioned vinyl flooring materials that their respective products are suitable for installation with Sigaway. For U.S.A., Canada, UK SIFLOOR AG, Tek Stil Concepts, Inc. and THG, are the sellers of materials only. The information and statements contained in these installation instructions are believed to be correct and to represent the current state of art. However, since the seller has no control over method of application, dryness of building, presence of moisture barriers, environment where used or surfaces to which the products are applied, there is no express or implied warranty for completed installation. The seller declines responsibility for labor cost for removal or reinstallation of defective installations, for freight charges, or for consequential damages. In no event is seller responsible if inappropriately stored, soil or water damaged materials or materials with visible defects are installed. It is solely the responsibility of the purchaser / installer to determine that the materials are fit for their particular purpose. Prerequisite for sale of our products is that the buyer purchases at his own risk and conducts installation tests prior to making a large installation, with no liability to us. This version of the Installation Instructions (August 2008) is the only valid version, and replaces all earlier variants. Page 5 of 5