Bassett Healthcare The Mary Imogene Bassett Hospital Microbiology Laboratory FUNGAL BLOOD CULTURE PROCEDURE

Similar documents
Unique patient demographic identifiers: Name, Date of Birth (DOB), medical record number (MRN), Social security number (SS#)

Standard Operating Procedure

RegenKit THT. Autologous Platelet Rich Plasma (A-PRP) Reference Guide. Biologics. Concentrated on Healing

PURE CULTURE TECHNIQUES

ASEPTIC TRANSFER & PURE CULTURE TECHNIQUES

TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE

Special Specimen Collection Procedures for Coagulation Testing

Chapter 9 Antimicrobial Susceptibility Testing (Agar Disk Diffusion Method)

LESSON ASSIGNMENT. After completing this lesson, you should be able to: Identify principles for maintaining a "working" stock culture.

Standard Operating Procedure (SOP) Specimen processing of CSF, lymph nodes and other tissues for Xpert MTB/RIF

Discussion. Objectives:

TITLE: LIVE/DEAD VIABILITY FOR CLINICAL SAMPLES

Guidelines for QualiTru Line Sampling

Document Title Versalyse Whole Blood Staining Method Department. Type Status CA

Exercise 19. Fungi: Molds and Yeasts F10 Or The Rotten World Around Us

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

Hemoglobin HemoCue Hb method

Average Yields* Yeast DNA Yeast RNA Time to Complete 10 Purifications * Yield will vary depending on the type of sample processed

UNIVERSITY OF TOLEDO HEALTH SCIENCE CAMPUS

MicroFunnel Filter Funnels

Title: Hemoglobin HemoCue Hb 301 method

Serum Isolation from Human Peripheral Blood

Bacterial Transformation and Protein Purification

Supplementary File 3: DNA and RNA isolation

Standard Operating Procedure

(Spin Column) For purification of DNA and RNA from formalin-fixed, paraffin-embedded tissue sections. Instruction for Use

Human IL-1 alpha ELISA Kit

UltraClean Endotoxin-Free Mini Plasmid Prep Kit

GRAM STAIN/CULTURE of CSF and OTHER BODY FLUIDS by HEMATOLOGY LAB (11:30pm 07:30am)

UltraClean Midi Plasmid Prep Kit

Aurum Plasmid 96 Kit. Instruction Manual. Bio-Rad Laboratories, Inc Alfred Nobel Drive Hercules, CA USA (510)

Artist Proof: Clotalyst. Autologous Serum Collection System

Large Volume Serial Dilutions:

SCHEDULE. Friday: Pet Investigations: Plate counts - how to know how many clones of your pet you have (pg. 9-10)

Introduction. Principle

Kit Components Product # (50 samples) Wash Solution A Elution Buffer B

Plasma Isolation from Human Peripheral Blood

ACSR 1.0 PURPOSE 2.0 SCOPE

E.Z.N.A. PF Micro RNA Kit. R preps R preps

E.Z.N.A. mirna Kit. R preps R preps R preps

Morris Animal. FOUNDATION Golden Retriever Lifetime Study

Blood Specimen Collections

Product # Kit Specification. Kit Specifications Maximum Column Binding Capacity 50 µg Maximum Column Loading Volume 650 µl

Fast, easy, reliable, ultra-pure transfection grade plasmid DNA Maxiprep using a microcentrifuge spin-column.

Isolation & Characterization of Bacteria

I-STAT POCT System PRINCIPLE:

Final Approval: October 2010 Effective: October 2010 Next Review Date: August 2012

Plasmid Midiprep Plus Purification Kit. Cat. # : DP01MD-P10/ DP01MD-P50 Size : 10/50 Reactions Store at RT For research use only

Entry Level Assessment Blueprint Biotechnology

Specifications. Kit Specifications. Alcohol Precipitation: Up to 100 ml Column Purification: Up to 5 ml Column Binding Capacity 25 µg

Revised 27 Aug rm (Vers. 4.1)

ITC Hemochron Signature Elite

Preparation thin blood films and Giemsa staining

PowerSoil DNA Isolation Kit

COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Biomaterial Hemolytic Assay. Kit Insert

Aseptic Techniques. A. Objectives. B. Before coming to lab

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Spin Micro DNA Extraction Kit

BD GeneOhm MRSA ACP Lysis Kit

ISOLATE II Blood DNA Kit. Product Manual

Note: The taller 100 x 13 mm tube is not designed to run on the ACL TOP. Plasma after centrifugation of these tubes must be placed in sample cups.

Actero Salmonella/STEC Enrichment Media Product Information

RealLine Extraction 100

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Geneaid DNA Isolation Kit (Yeast)

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

Aurum Plasmid Midi Kit. Instruction Manual. Bio-Rad Laboratories, Inc Alfred Nobel Dr. Hercules, CA USA (510)

EQUIPMENTS & MATERIALS COMMONLY USED IN A LABORATORY

Human IL-6 ELISA Set

Purification and Characterization of a DNA Plasmid Part A CHEM 4581: Biochemistry Laboratory I Version: January 18, 2008

Presto Mini gdna Bacteria Kit

UltraClean Standard Mini Plasmid Prep Kit Sample (Catalog No S)

Alkaline Lysis Large Scale Plasmid Preparation

Standard Operating Procedure Title: Handling of Media Diluents and Reagents in the Microbiology Laboratory

SenSATIVAx Plant/Microbial DNA Purification Kit Page 1 of 8

GenElute Total RNA Purification Kit. Catalog number RNB100

Microorganisms In Our Environment

This kit is intended for Research Use Only. Not for use in diagnostic procedures.

Adapted from Biology 15 Laboratory Manual Supplement: Wrightsman, Ininns and Cannon-Moloznic, Saddleback College, CA 92692

****** Competition ELISA Kit Instruction

Cytoplasmic & Nuclear RNA Purification Kit Product # 21000, 37400

FosmidMAX DNA Purification Kit

QIAfilter Plasmid Midi Kit (Cat #: 12243)

AccuPrep 96 Genomic DNA Extraction Kit Cat. No.: K

Product # 24700, 24750

Human Myostatin, ELISA Kit (MSTN)

Chlamydia Trachomatis Antigen Rapid Test Kit

BBL QualiSwab Quality Control Culture Devices

HBeAg and HBeAg Ab ELISA Kit

Purification of cytoplasmic RNA from animal cells using the RNeasy Mini Kit

VDL100.2 CLONING TRANSGENE INTO padenox

Project 7: Wound Cultures and Identification

Laboratory Procedure June 2003 HEALTH PRODUCTS AND FOOD BRANCH OTTAWA

QuickGene DNA whole blood kit S (DB-S)

Review Validation of aseptic processes for pharmaceuticals

Catalog No. SA-40002: 50 preparation SA-40001: 100 preparation

StrataPrep Plasmid Miniprep Kit

Transcription:

Bassett Healthcare The Mary Imogene Bassett Hospital Microbiology Laboratory FUNGAL BLOOD CULTURE PROCEDURE A. Purpose: To detect yeast or fungi in blood. B. Principle: The Du Pont isolator tube contains agents which lyse the cellular components of blood and block coagulation. Proper use of the tube will provide a concentration of organisms, from a blood sample, to be inoculated directly onto agar surfaces. C. Materials for Collection: Preferred: 1. one Du Pont isolator 10 ml tube; 2. needles and syringes; 3. alcohol and iodine preps. Suitable: 1. one Du Pont isolator 10 ml tube; 2. one BD 6.0 ml heparinized vacutainer tube 3. needles and syringes 4. alcohol and iodine preps. 5. BD Vacutainer Eclipse Blood Collection Needle 6. BD Hub D. Specimen Collection: CAUTION: Isolator tubes should be at room temperature before collection. Preferred Isolator Tube: 1. Scrub the black rubber stopper of the BD 6.0 ml heparinized vacutainer tube with an iodine solution. Avoid pooling of the solution on the rubber stopper. Allow the iodine to dry. 2. Disinfect the patient's arm appropriately for sterile venipuncture (see Blood Culture Collection procedure for skin preparation. If a syringe is utilized to inoculate the tube, the specimen must not be forced into the vacutainer. Do NOT perform butterfly draws due to the potential for clotting of the sample prior to entry into the tube. 3. The amount of blood present is most critical. When the tube is nearly full, 7.5 ml will be present. Tubes with lesser amounts should not be processed. 4. Gently invert the tube four or five times immediately after collection of the blood. 5. The tube, properly labeled with the patient's name, chart number, time, and date of collection, and a completed requisition (including time of collection) should be transported immediately to the Microbiology Laboratory. Suitable Heparinized vacutainer: 1. Scrub the black rubber stopper of the BD 6.0 ml heparinized vacutainer tube with an iodine solution. Avoid pooling of the solution on the rubber stopper. Allow the iodine to dry. 2. Disinfect the patient's arm appropriately for sterile venipuncture (see Blood Culture Collection procedure for skin preparation. If a syringe is utilized to inoculate the tube, the specimen must not be forced into the vacutainer. Do NOT perform butterfly draws due to the potential for clotting of the sample prior to entry into the tube. 3. Gently invert the tube four or five times immediately after collection of the blood. 4. Immediately forward BD 6.0 ml heparinized vacutainer tube to the Microbiology department for processing.

Fungal Blood Culture Procedure Page 2 E. Rejection Criteria: 1. Isolator tubes which contain less than the required amount of sample (less than 7.5 ml) should not be processed. 2. An extended delay in specimen transport of Dupont Isolator 10 ml tube, which would not allow processing of the sample within 16 hours from the collection time, is not acceptable. 3. An extended delay in specimen transport >7 days of the heparinized green top collection tube. F. Materials for Processing: Beckman TJ-6 centrifuge Alcohol preps Isostat rack Isostat supernatant pipet Isostat cap Isostat concentrate pipet Isostat press 2 - SAB dextrose plates 1 - LJ slant and 1 MGIT tube (if AFB ordered) G. Processing: 1. Blood samples a. Isolator tubes should be processed as soon as possible upon receipt in the laboratory. Batching of the specimens, when possible, should be performed to allow for maximum utilization of the technologist's time, but should provide maximum potential for the most rapid recovery of organisms. The time from collection to processing of Dupont Isolator 10 ml tube should never exceed 16 hours. b. Heparinized tubes should be processed as soon as possible upon receipt in the laboratory. The time from collection to processing of heparinizes tubes should never exceed 16 hours. Upon receipt in the Microbiology Department, transfer the contents of the heparinized vial (green top) to a Du Pont isolator 10 ml tube, using the BD Vacutainer Eclipse Blood Collection Needle and the BD hub. Perform all further manipulations in the Biological Safety Cabinet. Prior to specimen transfer disinfect the stoppers (Dupont Isolator 10 ml tube and BD 6.0 ml heparinized vacutainer tube) with alcohol. Allow adequate time for stoppers to dry. Insert BD Vacutainer Eclipse Blood collection needle into the BD 6.0 ml. heparinized tube 1 st. Insert unit (heparinized vial, BD hub and Eclipse Needle) into the Dupont Isolater 10 ml tube. The vacuum within the Dupont Isolator tube will automatically draw in the contents of the BD 6.0 ml heparinized tube. Gently invert the tube four or five times immediately after transfer of the blood. Incubate for 30 minutes contact time to allow for lysis of the red blood cells, prior to the centrifugation process. 2. Use the TJ-6 centrifuge in the Parasitology Room. Remove the rotor head currently on the centrifuge and replace with the rotor labeled Isolator Rotor. Place the tubes in the rotor using the adapters provided. Centrifuge the specimen for 30 minutes at 3000 g (the highest setting). In order to prevent breakage of the tube, 3000 g must not be exceeded. DO NOT USE THE CENTRIFUGE BRAKE. a. If sample is for Fungus (FBC) and Mycobacteria (ABC) culture, DO NOT process Isolator tube for up to 1 hour from time of collection. The one hour contact time allows for lysis of the red blood cells, prior to the centrifugation process. The extended (1 hour) lysis step is required for mycobacteria culture only. 3. Following centrifugation, carefully remove each isolator tube from its centrifuge adapter and place in the Isostat rack. A slight clockwise twist will facilitate insertion of the tube into the rack. Be sure tubes are firmly seated and vertically aligned to avoid breakage during insertion of the cap.

Fungal Blood Culture Procedure Page 3 4. Disinfect the stopper with an alcohol wipe. DO NOT allow the alcohol to pool in the stopper cavity. Allow to dry for one minute. 5. Place the rack on the base of the Isostat press. Perform all further manipulations in the Biological Safety Cabinet. 6. Remove Isostat cap from the sterile package by pushing the base of the cap out through the paper wrapper and grasping the sides of the cap with your fingers. 7. Place a cap over the top stopper of each isolator tube. If more than one tube is being processed, position caps on all tubes in the rack before proceeding to the next step. 8. Position a tube with its cap under the press head. Gently pull the handle of the press down as far as possible. The spike will penetrate the stopper, and the cap will be firmly seated on the top of the tube. Return the handle to the upright position. If more than one tube is being processed, rotate the rack to position the next tube. Press the cap onto this tube, and continue until caps have been pressed onto each tube in the rack. Carefully move the rack from the press to the work area. 9. a) Open the heat seal at the top of a package of Isostat supernatant pipets (large size), then pull apart the zippered seal. Remove a supernatant pipet from the package. b) Squeeze the bulb of the Isostat supernatant pipet to collapse it and provide a vacuum for supernatant withdrawal. Do this before inserting the stem into the tube. c) Carefully insert the stem of the supernatant pipet into the isolator tube through the membrane in the Isostat cap while maintaining pressure on the bulb. d) Insert the pipet into the tube as far as possible; the base of the bulb should rest on the cap. e) Release the bulb and allow the supernatant fluid to be drawn into the pipet. Repeat this procedure with the remaining tubes in the rack. f) Confirm that air has entered the pipets, indicating that all the supernatant fluid has been withdrawn. g) When the supernatant fluid has been withdrawn from all Isolator tubes, remove and discard the pipets into an appropriate receptacle for contaminated waste. 10. a) Open the heat seal at the top of a package of Isostat concentrate pipets (small pipets), then pull apart the zippered seal. Remove a concentrate pipet from the package. b) Remove the first isolator tube from the rack and vigorously mix the contents for 5-10 seconds (using the vortex mixer at its highest setting) in order to achieve a homogenous emulsion. c) Squeeze the bulb of the concentrate pipet to collapse it and provide a vacuum for concentrate withdrawal. Do this before inserting the stem into the tube. d) Carefully insert the stem of the concentrate pipet into the isolator tube through the membrane in the Isostat cap while maintaining pressure on the bulb. e) Insert the pipet into the tube so that the tip reaches to the bottom of the tube. It may be necessary to manipulate both pipet and tube to properly orient the pipet tip. f) Gradually release pressure on the bulb and allow the concentrate to be drawn into the pipet. A slow controlled release of the bulb is necessary to achieve maximum recovery of concentrate. 11. a) Immediately remove the pipet and use it to distribute the concentrate equally among the agar media. Use two SAB plates for fungal culture. If a mycobacteria culture is requested, add one Lowenstein Jensen slant and a MGIT tube. Keeping the lids of the plates as low as possible, dispense the concentrate in a straight line along the surface of the agar. Keep the inoculum away from the edge of the plate. b) Using a sterile inoculating loop, streak through the concentrate, making about 15 to 20 streaks perpendicular to the original inoculum line. Streak lines should be kept away from the edges of the plate. 12. Discard used pipets and isolator tubes into an appropriate receptacle for contaminated waste. 13. Wrap the fungal plates with fungal tape. Incubate at 25 C for 8 days. Check plates daily.

Fungal Blood Culture Procedure Page 4 14. Incubate fungal media according to fungal incubation procedures. Report positive fungal or mycobacteria blood cultures following the same protocol as for bacterial isolate. H. REFERENCES: Du Pont Isostat Microbial System Resource Guide. Du Pont Co., Wilmington, Del.; May 1987. Blood Safety and Clinical Technology; Guidelines for Laboratory Diagnosis of Tuberculosis and M. avium Complex Disease in HIV Positive Patients, World Health Organization Regional Office for South-East Asia (2009), Last Update: April 2006. Hanna Bruce A., Walters Shaun B., Bonk Stanley J., and Tick Leo J., Recovery of Mycobacteria from Blood in Mycobacteria Growth Indicatory Tube and Lowenstein-Jensen Slant after Lysis-centrifugation, Journal of Clinical Microbiology, Dec 1995, p 3315-3316. Manual of Clinical Microbiology 9th Edition, Murray, P.R, Baron, E.J., Pfaller, M.A., Jorgensen, J.H., Yolken, R.H., ASM Press, p 1728 1736.

Fungal Blood Culture Procedure Page 5 Document Name: Fungal Blood Culture Procedure Identifier: Microbiology Volume 1 Author: Cheryl Burtch Version Number: 3 Check one: New Document X Revised Document Document Removed from Service Date Removed from Service DESCRIPTION OF DOCUMENT Rationale for New or Revised Document: Updated Current Practice and References, current director Note all previous revision dates: Created 3/5/97; Updated 10/9/09, 12/17/12 File Path: F:\shared\Lab\Microbiology\Procedures\Vol 4\FBC Blood Cx 2009 List any related documents/forms/processes that are affected. Prepare additional Doc. Control Forms as needed. N/A Revision affects the following: MIBH GENERAL LAB LAB ADMIN Specific MIBH Lab sections: CLP Chem X Micro Heme Blood Bank Cytology Surgical Path POC LIS Phlebotomy Regional Sites: CRH Hamilton Herkimer OCH Oneonta OSS Dialysis TRH POC Is process validation affected? YES _X NO If so, why? SIGNATURE APPROVAL Tech. Specialist/Coordinator SIGNATURE Approval / Change Supervisor/Manager Samantha K. Davenport, M.D. Daniel Schreiber, M.D Valerie J. Bush, Ph.D. Simha R. Sastry, M.D John M. Fisk, M.D. Lori, Anderson, DO Issue Date for Training/ Effective Date for Use NA NA COMMUNICATION PLAN Section Meeting Date X E-mail to Micro Dept. Date: Lab Manual on website Date: Memo to Date:

Fungal Blood Culture Procedure Page 6