Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation

Notification of a Body pursuant to article 18 of the Construction Products Directive 89/106/EEC

Designation of a Notified Body pursuant to the Construction Products Regulation

Designation of a Notified Body pursuant to the Construction Products Regulation

Building Systems and Design Elements included in SliDeRulE

Within the framework of the notification mentioned above please find attached the

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

FENTRIM SEALING TAPES

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

Carpenter Level 2 Rev. September 2017

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS)

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS

PUDLO CWP (CEMENT WATERPROOFING POWDER)

Residential Building Inspections

Construction. Capabilities Sika UK. Concrete Production. Roofing. Elastic Sealing & Bonding. Waterproofing. Concrete Repair & Protection.

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

CHAPTER 3: Modern Methods of Construction (MMC)

Technical references for mortar and associated topics

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY

European Technical Assessment ETA-15/0362

Regulations Detail Sheet 1

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

Agrément Certificate 12/4912 website: Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER

11 FLAT ROOF CONSTRUCTION

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE

Panel System. Industrial Wood Construction Puu Atsushi Takano

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Certificate of Assessment

POLARWALL FORMWORK SYSTEMS POLARWALL INSULATING CONCRETE FORMWORK SYSTEM

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

Building Design Data

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Administrative Changes

Schedule T5. Tender Documents. This tender is for: Tender Documents: The documents issued for this tender include the following: Tender Schedules

Thermal Laminate Board.

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

GN18: BREEAM Recognised Responsible Sourcing Certification Schemes and BREEAM Scheme Applicability V3.1

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM

Agrément Certificate 13/5069 website: Product Sheet 1

YBS MULTI-LAYER INSULATION SUPERQUILT

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES

LEVEL TWO NUMBERS AND TITLES. Introductory Information. Bidding Requirements. Contracting Requirements. Facilities and Spaces. Systems and Assemblies

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION

Agrément Certificate 17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100

URSA MINERAL WOOL URSA Cavity Batts

BECO CONCRETE FORMWORK SYSTEMS BECO WALLFORM INSULATING CONCRETE FORMWORK SYSTEM

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR PITCHED ROOFS AND LOFT SPACES

Building Regulations

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS

KINGSPAN THERMAROOF TR21

H + H AIRCRETE BLOCKS AND THIN-JOINT SYSTEM H + H THIN-JOINT SYSTEM

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD

ICYNENE INSULATION H 2 FOAMLITE

THE STRATA UNIT May 25, 2008

THERMABLOK AEROGEL LTD THERMAL INSULATION SYSTEMS THERMABLOK AEROGEL THERMASLIM INTERNAL WALL INSULATION SYSTEMS

Planning and installation instructions

External Wall Insulation Systems GUARANTEED TO PERFORM!

SIP ENERGY STRUCTURAL INSULATED PANEL SYSTEM SIP ENERGY LOADBEARING WALL AND ROOF PANELS

SPRINGVALE CAVITY WALL INSULATION ECOBEAD PLATINUM CAVITY WALL INSULATION

3. The elements of the buildings envelope

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

Loss Prevention Standard

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

BAUDER PIR INSULATION BAUDER PIR ROOF INSULATION BOARDS

OPTIWIN MOTURA. Technical Description. Synopsis:

BRE Global Assessment Report

The Passive Fire Protection Handbook

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS

Aluminum Component Pipe Railings

Transcription:

21-47 High Street, Feltham, Middlesex, TW13 4UN, UK British Board of Agrément 17065:2012 to provide product conformity certification PO Box No 195 Bucknalls Lane Garston Watford Hertfordshire WD25 9BA Contact: Mr John Albon Tel: +44 (0)1923 665 300 Fax: +44 (0)1923 665301 Website: www.bbacerts.co.uk Locations where certification activities covered by the above Accreditation Standard are undertaken British Board of Agrément PO Box 195 Bucknalls Lane Garston Watford Herts. WD25 9BA United Kingdom Manager: CM2 Page 1 of 23

DETAIL OF ACCREDITATION Building Systems and Kits Product Standard BBA Technical Specifications 001 to 0013 and BBA Document BBA 001 Ceiling Products Concrete and Plaster Products Heating and Ventilation Products and Systems Finishes Floor Products Highway Works, Products and Systems Jointing Products, Components and Materials Masonry Products Roof and Roofing Products and Systems Drainage and Plumbing Products and Systems Wall and Cladding Products and Systems Window, Door and Opening Products and Systems Environmental Profiles of Construction Products - BRE Scheme Document SD 028 Manager: CM2 Page 2 of 23

Product Standard At the last review of Document BBA 001 the following standards were included within the scope of accreditation. Other standards may have since been added using the flexible scope arrangements. Metal Anchors for use in Concrete Part 1: Anchors in General (97/177/EC) ETAG 001 Metal Anchors for use in Concrete Part 4: Deformation-Controlled Expansion Anchors (97/177/EC) ETAG 001 Metal Anchors for use in Concrete Part 5: Bonded Anchors (97/177/EC) ETAG 001 Metal Anchors for use in Concrete Part 6: Anchors for Multiple use for Non-Structural Applications (97/177/EC) ETAG 001 Structural Sealant Glazing Systems (SSGS) Part 1: Supported and Unsupported Systems (96/582/EC) ETAG 002 Structural Sealant Glazing Systems (SSGS) Part 2: Coated Aluminium Systems (96/582/EC) ETAG 002 Structural Sealant Glazing Systems (SSGS) Part 3: Systems incorporating Profiles with a Thermal Barrier (96/582/EC) ETAG 002 International Partition Kits for use as Non Load-Bearing Walls (2001/596/EC) ETAG 003 External Thermal Insulation Composite Systems with Rendering (2001/596/EC) ETAG 004 Manager: CM2 Page 3 of 23

Product Standard Liquid Applied Roof Waterproofing Kits Part 1: General (2001/596/EC) ETAG 005 Systems of Mechanically Fastened Flexible Roof Waterproofing Membranes (98/143/EC) ETAG 006 Timber Frame Building Kits (99/455/EC) ETAG 007 Prefabricated Stair Kits in General (excluding severe climatic conditions) (2001/596/EC) ETAG 008 Non Load-Bearing Permanent Shuttering Kits/Systems based on Hollow Blocks or Panels of Insulating Materials and sometimes Concrete (2001/596/EC) ETAG 009 Self Supporting Translucent Roof Kits (2001/596/EC) ETAG 010 Light Composite Wood-Based Beams and Columns (99/92/EC) ETAG 011 Log Building Kits (99/455/EC) ETAG 012 Post-Tensioning Kits for Pre-stressing of Structures (98/456/EC) ETAG 013 Plastic Anchors for Fixing of External Thermal Insulation Composite Systems with Rendering (97/463/EC) ETAG 014 Three-Dimensional Nailing Plates (97/638/EC) ETAG 015 Self-Supporting Composite Lightweight Panels Part 1: General (94/23/EC) ETAG 016 Manager: CM2 Page 4 of 23

Product Standard Self-Supporting Composite Lightweight Panels Part 2: Specific Aspects Relating to Self-Supporting Composite Lightweight Panels for use in Roofs (94/23/EC) ETAG 016 Self-Supporting Composite Lightweight Panels Part 3: Specific aspects relating to Self-Supporting Composite Lightweight Panels for use in External Walls and Claddings (94/23/EC) ETAG 016 Self-Supporting Composite Lightweight Panels Part 4: Specific Aspects Relating to Self-Supporting Composite Light Panels for use in Internal Walls and Ceilings (94/23/EC) ETAG 016 Veture Kits - Prefabricated Units for External Wall Insulation (2001/308/EC) ETAG 017 Fire Protective Products Part 1: General (2001/596/EC) ETAG 018 Fire Protective Products Part 2: Reactive Coatings for Fire Protection of Steel Elements ETAG 018 Fire Protective Products Part 3: Renderings and Rendering Kits for Fire Resisting Applications ETAG 018 Fire Protective Products Part 4: Fire Protective Board, Slab and Mat Products and Kits ETAG 018 Pre-Fabricated Wood-Based Load-Bearing Stressed Skin Panels (94/23/EC) ETAG 019 Cold Storage Premises Kits Part 1: Cold Storage Room Kits (2005/484/EC) ETAG 021 Manager: CM2 Page 5 of 23

Product Thermal Insulation Products for Buildings - Factory Made Mineral Wool (MW) Products. Specification BS EN 13162:2008 Standard Thermal Insulation Products for Buildings - Factory Made Products of Expanded Polystyrene. Specification BS EN 13163:2008 Thermal Insulation Products for Buildings - Factory Made Products of Extruded Polystyrene Foam (XPS). Specification BS EN 13164:2008 Thermal Insulation Products for Buildings - Factory Made Rigid Polyurethane Foam (PUR) Products. Specification BS EN 13165:2001 Thermal Insulation Products for Buildings - Factory Made Products of Phenolic Foam (PF). Specification BS EN 13166:2001 Thermal Insulation Products for Buildings - Factory Made Cellular Glass (CG) Products. Specification BS EN 13167:2008 Thermal Insulation Products for Buildings - Factory Made Wood Wool (WW) Products. Specification BS EN 13168:2001 Thermal Insulation Products for Buildings - Factory Made Products of Expanded Perlite (EPB). Specification BS EN 13169:2008 Thermal Insulation Products for Buildings - Factory Made Wood Fibre (WF) Products. Specification BS EN 13171:2001 Wood-Based Panels for use in Construction. Characteristics, Evaluation of Conformity and Marking BS EN 13986:2004 Timber Structures. Structural Laminated Veneer Lumber. Requirements BS EN 14374 Timber Structures - Connectors - Requirements pren 14545 Manager: CM2 Page 6 of 23

Product Standard Timber Structures. Dowel-type fasteners. Requirements BS EN 14592:2008 Admixtures for Concrete, Mortar and Grout. Concrete Admixtures. Definitions, Requirements, Conformity, Marking and Labelling BS EN 934-2 Specification for Masonry Units. Autoclaved Aerated Concrete Masonry Units BS EN 771-4 Specification for Mortar for Masonry. Masonry mortar BS EN 998-2 Thermal insulation products for buildings - In situ formed loose-fill mineral wool (MW) Part 1: Specification for the loose fill products before installation BS EN 14064-1 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics BS EN 14351-1 Flexible sheets for waterproofing Bitumen damp proof sheets including bitumen basement tanking sheets Definitions and characteristics BS EN 13969:2004 Manager: CM2 Page 7 of 23

Product Standard The certification systems used for the above are one or more of the following: Type testing or examination Product evaluation Design appraisal These can be coupled with assessment and surveillance of production, the supplier s quality system and/or installation sites. Where appropriate a: European Technical Approval, or Certificate or Statement of Conformity, or BBA Agrément Certificate Certificate of factory production control Will be issued to the supplier along with (if relevant) a license to use the appropriate mark of conformity. Micro-generation Product Certification Solar Collectors Solar Photovoltaic Panels Micro and Small Wind Turbines Heat Pumps Biomass Heat-led Micro - Co Generation Packages Electricity Led Micro Co-Generation Packages Bespoke Building Integrated Photovoltaic Products Pitched Roof Installation Kits DECC Scheme Requirements MCS 004 - Solar Collectors MCS 005 - Solar Photovoltaic Panels MCS 006 - Micro and small wind turbines MCS 007 - Heat Pumps MCS 008 - Biomass MCS 014 - Micro CHP MCS 015 Electricity Led Micro Co-Generation Packages MCS 017-Bespoke Building Integrated Photovoltaic Products MCS 012-Pitched Roof Installation Kits MCS 010 (Generic Factory Production Control) MCS 011 (Testing and acceptance criteria) Manager: CM2 Page 8 of 23

Product Installation of following Green Deal measures: Cavity Wall Insulation Loft Insulation Pitched Roof Insulation Flat Roof Insulation Internal Wall Insulation External Wall Insulation Hybrid Wall Insulation Draught Proofing Floor Insulation Energy Efficient Glazing and Doors Standard PAS 2030:2014 Improving the energy efficiency of existing buildings Specification for installation process, process management and service provision. Edition 1 January 2014 PAS 2031:2012 Certification of Energy Efficiency Measure (EEM) installation services Edition 1 March 2012 Installation of insulating material to the internal walls of a building, not including the installation of flexible thermal linings Installation of insulating material to the external walls of a building, not including the insulation of demountableclad buildings Installation of insulating material to the external and internal walls of a building ( hybrid insulation ), not including the insulation of demountable-clad buildings, and not including the installation of flexible thermal linings DCLG Conditions of Authorisation 6 June 2012 And The Competent Person Scheme BBA Solid Wall Insulation Competent Person Scheme in accordance with the Building Regulations 2010 (as amended) END Manager: CM2 Page 9 of 23

97/555/EC Cements, building limes and other hydraulic binders : - Common cements, including: - Portland cement, -Portland composite cements: Portlandslag cement, Portland-silica fume cement, Portlandpozzolana cement, Portland-fly ash cement, Portland-burnt shale cement, Portlandlimestone cement, Portland composite cement, - Blastfurnace cements, -Pozzolanic cements, - Composite cements (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products) EN 197-1:2000 EN 197-1:2000/ A1:2004 EN 197-1:2000/A3:2007 EN 197-1:2011 97/555/EC Cements, building limes and other hydraulic binders : - Building limes, including: - Calcium limes, -Dolomitic limes, -Hydraulic limes (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products). EN 459-1:2010 97/740/EC Masonry and related products (1/3) : - Masonry units category I EN 771-4:2011 Manager: CM2 Page 10 of 23

Annex V- Testing Laboratory System 3 97/740/EC Masonry and related products (2/3) : - Ties (in walls and partitions), Tension straps (in walls and partitions), Joist hangers (in walls and partitions), Brackets (in walls and partitions). EN 845-1:2003+A1:2008 Annex V- Testing Laboratory System 3 97/740/EC Masonry and related products (2/3) : - Lintels (in walls and partitions). EN 845-2:2003 99/469/EC Products related to concrete, mortar and grout (1/2) : - Admixtures (for concrete, mortar and grout). EN 934-2:2009 97/740/EC Masonry and related products (1/3) : - Factory-made,designed masonry mortars (in walls, columns and partitions). EN 998-2:2010 Manager: CM2 Page 11 of 23

98/214/EC Structural metallic products and ancillaries (2/4) : - Structural metallic construction members: finished metallic products such as trusses, girders, columns, stairs, ground piles, bearing piles and sheet piling, cut to size sections designed for certain applications, and rails and sleepers. They can be unprotected or protected against corrosion by coating, welded or not. (for uses in work's frames and foundations) EN 1090-1:2009 EN 1090-1:2009+A1:2011 EN 1090-1:2009/AC:2010 99/469/EC EN 1504-2:2004 Products related to concrete, mortar and grout (1/2) : - Concrete protection and repair products EN 1504-3:2005 EN 1504-4:2004 EN 1504-5:2004 EN 1504-6:2006 EN 1504-7:2006 98/601/EC EN 12271:2006 Road construction products (1/2) : - Surface treatments (for surface treatments of roads). EN 12273:2008 Manager: CM2 Page 12 of 23

Directive/Regulation Confority 98/601/EC Road construction products (1/2) : - Bituminous mixtures (for road construction and surface treatment of roads). EN 13108-1:2006 EN 13108-1:2006/AC:2008 EN 13108-2:2006 EN 13108-2:2006/AC:2008 EN 13108-3:2006 EN 13108-3:2006/AC:2008 EN 13108-4:2006 EN 13108-4:2006/AC:2008 EN 13108-5:2006 EN 13108-5:2006/AC:2008 EN 13108-6:2006 EN 13108-6:2006/AC:2008 EN 13108-7:2006 EN 13108-7:2006/AC:2008 Annex V- Testing 99/91/EC EN 13162:2008 Laboratory System 3 Thermal insulating products (1/2) : - Thermal insulating products EN 13163:2008 EN 13164:2008 EN 13165:2008 EN 13166:2008 EN 13167:2008 EN 13168:2008 EN 13169:2008 EN 13170:2008 EN 13171:2008 EN 14064-1:2010 and Annex V- Testing Laboratory System 3 99/91/EC Thermal insulating products (2/2) : - Thermal insulating products EN 13162:2008 EN 13163:2008 EN 13164:2008 EN 13165:2008 EN 13166:2008 EN 13167:2008 EN 13168:2008 EN 13169:2008 EN 13170:2008 EN 13171:2008 EN 14064-1:2010 Manager: CM2 Page 13 of 23

99/90/EC Membranes (1/3) : - Roof sheets (in buildings). EN 13707:2004+A2:2009 EN 13956:2005 EN 13956:2005/AC:2006 99/90/EC Membranes (2/3) : - Roof sheets (for uses subject to reaction to fire regulations). EN 13707:2004+A2:2009 EN 13956:2005 EN 13956:2005/AC:2006 98/601/EC Road construction products (1/2) : - Bitumen (for road construction and surface treatment of roads). EN 13808:2005 EN 14023:2010 99/90/EC EN 13967:2004 Membranes (1/3) : - Damp proofing sheets (in buildings). EN 13967:2004/A1:2006 EN 13969:2004 EN 13969:2004/A1:2006 and 97/462/EC Wood-based panels (1/2) : - Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications). EN 13986:2004 97/462/EC Wood-based panels (2/2) : - Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications). EN 13986:2004 Manager: CM2 Page 14 of 23

Annex V- Testing Laboratory System 3 98/436/EC Roof coverings, rooflights, roof windows and ancillary products (6/6) EN 14351-1:2006+A1:2010 Annex V- Testing Laboratory System 3 99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) : EN 14351-1:2006+A1:2010 97/176/EC Structural timber products (1/3) and (2/3) EN 14374:2004 97/638/EC Fasteners for structural timber products (1/1 EN 14545:2008 ETAG 015 98/601/EC Road construction products (1/2) : - Bridge deck waterproofing products and kits (for bridge decks). EN 14695:2010 Annex V- Testing Laboratory System 3 97/176/EC Structural timber products (3/3) : - Fasteners for structural timber products EN 14592:2008 Manager: CM2 Page 15 of 23

99/469/EC Products related to concrete, mortar and grout (1/2) : - Fibres (for structural uses in concrete, mortar and grout) EN 14889-1:2006 EN 14889-2:2006 99/94/EC Precast normal/ lightweight/ autoclaved aerated concrete products (1/1) : - Precast normal/ lightweight/ autoclaved aerated concrete products (for structural use). EN 15037-4:2010 + 99/469/EC Products related to concrete, mortar and grout (1/2) : - Additions (Type II) (for concrete, mortar and grout). EN 15167-1:2006 96/582/EC ETAG 001-1 Metal anchors for use in concrete (mechanical fasteners) : - Metal anchors for use in concrete (heavy-duty type) (for fixing and/or supporting concrete structural elements or heavy units such as cladding and suspended ceilings). ETAG 001-2 ETAG 001-3 ETAG 001 3 Amendment ETAG 001-4 ETAG 001-5 ETAG 001-6 ETAG 001 6 Amendment 97/177/EC Metal injection anchors for use in masonry (1/1) : - Metal injection anchors for use in masonry ETAG 001-5 Manager: CM2 Page 16 of 23

97/463/EC Plastic anchors for use in concrete and masonry (1/1) ETAG 001-6 ETAG 001 6 Amendment ETAG 014 96/582/EC Structural sealant glazing kits of types (curtain walling) : - Structural sealant glazing kits, Types II and IV (for external walls and roofs). ETAG 002-1 ETAG 002-2 ETAG 002-3 96/582/EC Structural sealant glazing kits of types (curtain walling) : - Structural sealant glazing kits, Types I and III (for external walls and roofs). ETAG 002-1 ETAG 002-2 ETAG 002-3 98/213/EC Internal partition kits (1/5) ETAG 003 and 97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) : - ETAG 004 Version 08/2011 Manager: CM2 Page 17 of 23

and 98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) ETAG 004 Version 08/2011 ETAG 009 98/599/EC Liquid applied roof waterproofing kits (3/3) : - Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations) ETAG 005 98/143/EC Systems of mechanically fastened flexible roof waterproofing membranes (1/1) ETAG 006 99/455/EC Timber frame and log prefabricated building kits (1/1) ETAG 007 ETAG 012 99/89/EC Prefabricated stair kits (1/2) ETAG 008 99/89/EC Prefabricated stair kits (2/2) ETAG 008 Manager: CM2 Page 18 of 23

98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) ETAG 010 99/92/EC Light composite wood-based beams and columns (1/1) ETAG 011 + 98/456/EC Post-tensioning kits for the prestressing of structures (1/1) ETAG 013 2000/447/EC Prefabricated wood-based loadbearing stressed skin panels and self-supporting composite lightweight panels (3/6) ETAG 016-1 ETAG 016-2 ETAG 016-3 ETAG 016-4 99/454/EC Fire stopping, fire sealing and fire protection products (1/2) and (2/2) ETAG 018-1 ETAG 018-4 ETAG 018-4 Amendment 2000/447/EC Prefabricated wood-based loadbearing stressed skin panels and self-supporting composite lightweight panels (1/6) and (3/6) ETAG 019 Manager: CM2 Page 19 of 23

and 2003/655/EC Watertight coverings kits for wetroom floors and walls (1/2 ETAG 022-1 ETAG 022-2 ETAG 022-3 & 2+ & 2+ 2003/655/EC Watertight coverings kits for wetroom floors and walls (2/2) ETAG 022-1 ETAG 022-2 ETAG 022-3 2003/722/EC Liquid-applied bridge deck waterproofing kits : - Liquid-applied bridge deck waterproofing kits (in bridge decks). ETAG 033 2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits : - Prefabricated building units (in building works). ETAG 023 Manager: CM2 Page 20 of 23

As a Technical Body (TAB) for developing European Documents Annex IV Product Areas 1. Precast normal / lightweight / autoclaved aerated concrete products. 2. Doors, windows, shutters, gates and related building hardware. 3. Membranes, including liquid applied and kits (for water and/or water vapour control) 4. Thermal insulation products. composite insulating kits / systems. 6. Chimneys, flues and specific products 7. Gypsum products 8. Geotextiles, geomembranes, and related products. 9. Curtain walling / cladding / structural sealant glazing. 12. Circulation fixtures: road equipment 13. Structural timber products / elements and ancillaries. 14. Wood based panels and elements 15. Cement, building limes and other hydraulic binders. Manager: CM2 Page 21 of 23

As a Technical Body (TAB) for developing European Documents Annex IV Product Areas 16. Reinforcing and prestressing steel for concrete (and ancillaries). post tensioning kits 17. Masonry and related products. masonry units, mortars, and ancillaries. 18. Waste water engineering products 19. Floorings. 20. Structural metallic products and ancillaries. 21. Internal & external wall and ceiling finishes.internal partition kits 22. Roof coverings, roof lights, roof windows, and ancillary products. roof kits 23. Road construction products. 24. Aggregates 25. Construction adhesives 26. Products related to concrete, mortar and grout. 27. Space heating appliances 28. Pipes-tanks and ancillaries not in contact with water intended for human consumption Manager: CM2 Page 22 of 23

As a Technical Body (TAB) for developing European Documents Annex IV Product Areas 29. Construction products in contact with water intended for human consumption 30. Flat glass, profiled glass and glass block products 32. Sealants for joints 33. Fixings 34.Building kits, units, and prefabricated elements. END Manager: CM2 Page 23 of 23