X-STREAM X2XF - Field Housing Gas Analyzer

Similar documents
X-STREAM Enhanced XEXF - Field Housing Gas Analyzer

>>> Process Gas Analysis Solutions

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

EuroFID Total Hydrocarbon Analyzer

On-Line Gas Analysis In Air Separation Plants

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

S700 Modular Gas Analyzer. Measures more than 60 different gases

Sensor unit MC2 for toxic gases and oxygen with analog output

Multi-component gas analysis with speed, repeatability, and reliability.

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Online data sheet MCS100E HW-C CEMS SOLUTIONS

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Fpollutant-free zero air for analytical

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Using the PPM2 Portable Trace Moisture Transmitter

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Heat Value Gas Chromatograph ISO standard version

Online Gas Analyzer / Monitor

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

???? Spot Check Measurement Simple, accurate, reliable

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

ON-LINE OIL TRACE MONITOR

Process Total Organic Carbon Analyzer

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Technical Note TN-114 rev 16 wy/wh.11-04

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

For Safe and Delicious Water

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES

3SP_CO_1000 Package

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Inlet-Residue-NGL Solutions for Natural Gas Processing Applications

ACX Analyzer systems for emission monitoring, cement applications and process measurement

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

Features. Measurement range :0-10ppm or 0-500ppm. Large touch panel display for easy operation in the field. Standard Specifications

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

COMBIMASS Thermal Gas Flow

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

SpectraSensors SS500 Mid-Sensitivity Moisture Analyzer

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Process Analyzer. UV Oil in Water Analyzer Model W-800. Credible Solutions for the Oil and Gas Industry

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Expanding the Versatility of Micro GC in the Shale Gas Play; The Agilent 490 Micro GC offers unprecedented reliability and flexibility

Rosemount Differential Pressure Level Solutions. Keeping You a Step Ahead

TVOC Heated FID VE 7

Standard Continuous Emissions Monitoring System (CEMS)

Analytical Instruments

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Process Gas Monitoring In Petroleum Refineries

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

GMS800 FIDOR Total hydrocarbon analyzer. Gas Analyzers

Sensor Technologies used in Portable Gas Monitors. HA University

Sensor Specifications and CroSS- Sensitivities

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

GAS 3050P NDIR FLUE GAS

8 stream capability with dual mode (H 2 S & total Sulphur)

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

OPTIMASS 7400 Technical Datasheet

Measuring moisture in ultra-high-purity gases

DR1000 Flying Laboratory, Drone Environmental Monitoring

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

MAX300-BIO PRODUCT NOTE. Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis. Bioreactor/Fermentation Mass Spectrometer

Liquidew EExd. Liquidew EExd. Moisture in Liquids Analyser. The complete moisture measurement package for critical petrochemical liquid applications

For highest levels of purity

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Prima PRO process mass spectrometer

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

CYTOPERM 2 CO 2 - AND CO 2

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

ADI 7010 TOC Analyzer. Continuous monitoring of total organic carbon

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

Use of Process Analytics in Cryogenic Air Separation Plants

Waarom moeilijk doen als het makkelijk(er) kan

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Vortex EX DELTA lowmeter Technical Specifications

Flow Through Toroidal Conductivity Sensor

SECTION Coriolis Mass Flow Meters

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.

PROCESS MOISTURE ANALYZERS Measuring moisture in gas or HC liquids in hazardous areas

Gas Generators. Parker Balston

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

UV400 ATEX. Online Water Analyser. Specialist Of UV Spectroscopy

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Transcription:

X-STREAM XXF PGA-PDS-X-STREAM-XXF Product Data Sheet September 0 X-STREAM XXF - Field Housing Gas Analyzer Up to four component gas analyzer featuring NDIR/UV/VIS photometer, paramagnetic and electrochemical O, thermal conductivity and moisture sensors Enhanced performance with IntrinzX technology Wall mountable NEMA X/IP66 stainless steel housing Plantweb connectivity and WinControl data acquisition X-STREAM XXF - Field Housing Gas Analyzers Features The X-STREAM field housing analyzer provides powerful analytical technology in a wall-mountable NEMA X/IP66 stainless steel housing. Special solutions for Zone and Div. hazardous areas are available with CSA-C/US approval. The dualcompartment version with separated physics and electronics enables complete gas-tight separation. Flexibility The X-STREAM platform enables the combination of up to four channels of non-dispersive infrared, ultraviolet, visible photometers (NDIR/UV/VIS), thermal conductivity (TCD), trace moisture (th O), paramagnetic and electrochemical oxygen (po /eo ) detectors and sensors. Performance With the X-STREAM photometer technology, the analyzer provides a measuring accuracy that allows improving your process while also reducing the total cost of ownership by: Large dynamic ranges Very low temperature dependency Outstanding long-term stability Simplified calibration Communication X-STREAM analyzers provide four status signal relay outputs (according to NAMUR NE 07), MODBUS RTU over serial (RS/8), MODBUS TCP protocol over Ethernet communication as option. The X-STREAM X analyzer provides: One to four analog outputs Optional digital inputs and relay outputs Serial interface with Modbus communication Easy integration into DeltaV systems A pre-engineered DeltaV module features easy integration of X-STREAM X into your DeltaV environment via ModbusRTU over serial interface. Data acquisition with XTR WinControl This optional PC software supports online and offline data processing as well as data export to external devices. Calculator channels enable extended processing capabilities for measurement data. The configurable user interface enables vizualization of sampling points by including a plant image as background for measured values.

September 0 X-STREAM XXF Ease of use The instrument has an alphanumeric display and is operated manually by six keys. Clear text messages (available in several languages) and front panel LEDs provide information about the measurement and the analyzer status. The default configuration features a LC display, an optional VF (vacuum flourescence) display is available. Options in a Field Housing Enclosure Sample gas pump Flow measurement and alarm Valve block Pressure sensor Digital Input/Output cards XTR WinControl: Data acquisition with configurable layout. Worldwide Approvals Process Approved Sensors CSA-C/US, IEC and CE approvals allow global installation of X-STREAM field housing analyzers. Furthermore CSA-C /US approvals for Zone and Division allow installation in hazardous areas. Solvent-resistant, corrosion-resistant, and infallible containment solutions are available. Applications Refining petrochemical and chemical process analysis and control Hydrogen, ammonia and fertilizer production Gas purity and air separation units Natural gas production and distribution Metallurgical manufacturing, hardening and heat treatment processes Biogas and landfill Safety measurements for flammable mixtures Hydrogen cooling of gas turbines Interior view, showing four NDIR benches, thermostatic control (cover removed), analog and relay outputs, digital inputs and serial interface. The alphanumeric display of the X-STREAM X provides measurement and status information with plain text on either a LCD or VFD, supported by LEDs. The user interface remains operable with door open (see left image).

September 0 X-STREAM XXF Specifications Lowest and Highest Ranges Available for Different Gases (Excerpt) In total, the X-STREAM family of process gas analyzers can detect more than 60 gases. The following table is an excerpt, showing the most commonly used gases. Contact your Emerson representative for information on configurations or gases that are not listed. Table - Gas Components and Measuring Ranges, examples Gas component Principle Special Specs or Conditions Lowest Range Lowest Range Standard Specs (Table ) Highest Range Acetone CH COCH UV 0 00 ppm 0 % Acetone CH COCH IR 0 00 ppm 0 % Acetylene C H IR 0 % 0 00 % Ammonia NH IR 0 00 ppm 0 00 % Argon Ar TCD 0 0 % 0 00 % Carbon dioxide CO IR 0 ppm 0 0 ppm 0 00 % Carbon monoxide CO IR 0 0 ppm 0 0 ppm 0 00 % Chlorine Cl UV 0 00 ppm 0 00 % Ethane C H 6 IR 0 000 ppm 0 00 % Ethanol C H OH IR 0 000 ppm 0 0 % Ethylene C H IR 0 00 ppm 0 00 % Helium He TCD 0 0 % 0 00 % Hexane C 6 H IR 0 00 ppm 0 0 % Hydrogen H TCD 0 % 0 00 % Hydrogen Sulfide H S UV 0 % 0 0 % Hydrogen Sulfide H S IR 0 0 % 0 00 % Methane CH IR 0 00 ppm 0 00 % Methanol CH OH IR 0 000 ppm 0 0 % n Butane C H 0 IR 0 800 ppm 0 00 % Nitrogen dioxide NO UV 0 ppm 0 00 ppm 0 0 % Nitrogen monoxide NO IR 0 00 ppm 0 0 ppm 0 00 % Nitrous oxide N O IR 0 00 ppm 0 00 % Oxygen O electrochem. 0 % 0 % Oxygen O paramagn. 0 % 0 00 % Propane C H 8 IR 0 000 ppm 0 00 % Propylene C H 6 IR 0 00 ppm 0 00 % Sulfur dioxide SO UV 0 ppm 0 0 ppm 0 % Sulfur dioxide SO IR 0 % 0 00 % Sulfur hexafluoride SF 6 IR 0 ppm 0 0 ppm 0 % Toluene C 7 H 8 UV 0 00 ppm 0 % Vinyl chloride C H Cl IR 0 000 ppm 0 % Water vapor H O IR 0 000 ppm 0 8 % Water vapor, Trace H O capacitive 0 00 ppm 0 000 ppm Dew point below ambient temperature Higher concentrations decrease sensor lifetime Daily zero calibration: Required for ranges below lowest standard specs range Special "refinery" application with 0 % H in N available see Table

X-STREAM XXF September 0 Standard Performance Specifications Table - IR/UV/VIS, TCD Standard Measurement Performance Specifications NDIR/UV/VIS Thermal Conductivity (TCD) Detection limit ( σ) % % Linearity % % Zero-point drift % per week % per week Span (sensitivity) drift 0. % per week % per week Repeatability % % Response time (t 90 ) s t 90 7 s s t 90 0 s 6 Permissible gas flow 0.. l/min. 0.. l/min. Influence of gas flow 0. % % Maximum gas pressure 8 00 hpa abs. ( 7 psig) 00 hpa abs. ( 7 psig) Influence of pressure At constant temperature 0.0 % per hpa 0.0 % per hpa With pressure compensation 7 0.0 % per hpa 0.0 % per hpa Permissible ambient temperature 9 0 (-0) to +0 C ( (-) to F) 0 (-0) to +0 C ( (-) to F) Influence of temperature (at constant pressure) On zero point % per 0 K % per 0 K On span (sensitivity) % (0 to +0 C / to F) % per 0 K Thermostat control 6 none / 60 C (0 F) none / 60 C (0 F) 0 Warm-up time 6 to 0 minutes approx. 0 minutes Note! psi = 68.9 hpa Related to full scale Related to measuring value From gas analyzer inlet at gas flow of.0 l/min (electronic damping = 0 s) Constant pressure and temperature Dependent on integrated photometer bench 6 Depending on measuring range 7 Pressure sensor is required 8 Limited to atmospheric if internal sample pump 9 Temperatures below 0 C (- F) with thermostat control only 0 Thermost. controlled sensor: 7 C (67 F) Flow variation within ± 0. l/min Optional thermostat controlled box with temperature 60 C (0 F) Temperature variation: 0 K per hour Table - Oxygen Standard Measurement Performance Specifications Oxygen Sensors Paramagnetic (po ) Electrochemical (eo ) Detection limit ( σ) % % Linearity % % Zero-point drift % per week % per week Span (sensitivity) drift % per week % per week Repeatability % % Response time (t 90 ) < s approx. s Permissible gas flow 0.. l/min 0.. l/min. Influence of gas flow % 0 % Maximum gas pressure 7 00 hpa abs. ( 7 psig) 00 hpa abs. ( 7 psig) Influence of pressure At constant temperature 0.0 % per hpa 0.0 % per hpa With pressure compensation 6 0.0 % per hpa 0.0 % per hpa Permissible ambient temperature 8 0(-0) to +0 C ( () to F) to + C ( to F) Influence of temperature (at constant pressure) On zero point % per 0 K % per 0 K On span (sensitivity) % per 0 K % per 0 K Thermostat control 60 C (0 F) none Warm-up time Approx. 0 minutes - Related to full scale Related to measuring value From gas analyzer inlet at gas flow of.0 l/min (electronic damping = 0 s) Constant pressure and temperature reserved for future use 6 Pressure sensor is required 7 Limited to atmospheric if internal sample pump 8 Temperatures below 0 C (- F) with thermostat control only 9 Thermost. controlled sensor: C (9 F) 0 For ranges 0 00 % and flow 0.. l/min Optional thermostat controlled sensor with temperature 60 C (0 F) Temperature variation: 0 K per hour No sudden pressure surge allowed

September 0 X-STREAM XXF Table - Trace Moisture Standard Measurement Performance Specifications Trace Moisture (th O) Measurement range -00 to -0 C dew point (0 00 000 ppm) Measurement accuracy ± C dew point Repeatability 0. C dew point Response time (t 9 ) min (dry to wet) Operating humidity 0 to 00 % r.h. Sensor operating temperature -0 to +60 C Temperature coefficient Temperature compensated across operating temperature range Operating pressure Depending on sequential measurement system, see analyzer specification max. 00 hpa abs / 7 psig Flow rate Depending on sequential measurement system, see analyzer specification 0. to. l/min If installed in series to another measurement system, e. g. IR channel Note! psi = 68.9 hpa Note! Not all data listed are applicable to all analyzer versions (e.g. 60 C thermostat controlled box is not available for electrochemical oxygen). Note! For NDIR/UV/VIS measurements, take into account that sample gas may diffuse or be released by leakages into the analyzer enclosure. If existent in the analyzer surroundings, the component to be measured may enter the enclosure. Concentrations then may increase inside the enclosure. High concentrations of the component to be measured inside the enclosure may influence the measurement by unintended absorption, which could cause drift of the measurement. A remedy for this issue is to purge the housing with gas not containing the component of interest. Note! Measurement principles or composition of sample gas may limit the available options for a specific analyzer configuration concerning e. g. sample handling options or tubing materials. Special Performance Specifications for Gas Purity Measurements (ULCO & ULCO ) Table - Special Performance Specifications for Gas Purity Measurements 0 0 < 0 ppm CO 0 < 0 ppm CO Detection limit ( σ) < % Linearity < % Zero-point drift < % resp. < 0. ppm 9 Span (sensitivity) drift < % resp. < 0. ppm 9 Repeatability < % resp. < 0. ppm 9 Response time (t 90 ) 7 < 0 s Permissible gas flow 0.. l/min. Influence of gas flow < % Maximum gas pressure 0 00 hpa abs. ( 7 psig) Influence of pressure At constant temperature 0. % per hpa With pressure compensation 8 0.0 % per hpa Permissible ambient temperature + to + C (9 to 9 F) + to +0 C ( to 0 F) Influence of temperature 6 (at constant pressure) On zero point < % per 0 K resp. < 0. ppm per 0 K 9 On span (sensitivity) < % per 0 K resp. < 0. ppm per 0 K 9 Thermostat control none 60 C (0 F) Note! psi = 68.9 hpa Related to full scale Constant pressure and temperature Within h; daily zero calibration requested Within h; daily span calibration recommended Related to measuring value 6 Temperature variation: 0 K per hour 7 From gas analyzer inlet at gas flow of.0 l/min 8 Barometric pressure sensor is required 9 Whichever value is higher 0 Limited to atmospheric if internal sample pump

X-STREAM XXF September 0 General Specifications Compliances Analog signal outputs:, individually optically isolated (0) 0 ma (R B 00 Ω) Relay outputs: Communication interface (optional): Digital I/O (optional): CE DIN EN 600- DIN EN 66- CSA-C/US C. No 600- UL Std No. 600- CSA-C/US (option N) C-TICK NAMUR Gas Connections Stainless steel: 6/ mm or /"; Rated voltage 00 0 V, 0/60 Hz Rated input current. A (. A for dual compartment) Power input Internal screw terminals Signal Connections Screw terminals; option RJ for MODBUS TCP Enclosure Protection Type X, IP 66 acc. EN 609 for outdoor installation, protected against direct sunlight Humidity (non-condensing) Weight Options Signal In- & Outputs, Interfaces < 90 % r.h. @ 0 C (68 F) < 70 % r.h. @ 0 C (0 F) Up to kg (. lbs) (up to kg (99. lbs) for dual compartment) depending on configuration Integrated flow measurement(s) with alarm(s), barometric pressure sensor, thermostatically controlled box for physical components (60 C / 0 F), case purge, sampling pump(s) and/or solenoid valve block(s) for autocalibration status relays acc. NAMUR NE 07 or e.g. concentration thresholds, valve status notification; dry contacts: A, 0 V RS 8 / C with Modbus RTU optional: Ethernet with Modbus TCP 7/ digital inputs (for remote control); max. 0 VDC,. ma, common ground 9/8 additional relay outputs (e.g. concentration thresholds, valve status notification, flow alarm, range ID); dry contacts: A, 0 V Dimensions All dimensions in mm [inches in brackets] Basic dimensions applicable to all variations 6

September 0 X-STREAM XXF Non-Incendive Version for Hazardous Areas (EX Zone and Division ) Zone / Division classification is characterized by the fact that explosive atmosphere is not likely to exist under normal operating conditions. For equipment to be installed in Zone / Division, it is sufficient to ensure that the equipment is not a source of ignition under normal operating conditions. Equipment with higher protection levels (e. g. with concepts for Zone I / Division ) are permitted to be installed in such areas as well, but are more cost-intensive. An example for such an equipment is a flameproof enclosure (Ex d), also available within the X-STREAM gas analyzer series. Protection method of X-STREAM field housing for Zone / Division installations is non-incendive (Ex n). These models are third-party agency approved to carry CSA-C/US markings, based on North American CSA and UL standards. The non-incendive design (Ex nac IIC T) enables installation without the need for purge gas supply, saving infrastructure costs, as well as follow-up costs for purge gas. Compared to a flameproof enclosure, the painted stainless steel housing is much easier to install and does not require an as stable foundation, also saving costs. The enclosure provides IP66 / Type X protection against dust and heavy seas, making it the first choice for outdoor installations. Flammable gases cannot be measured with a standard nonincendive analyzer, because internal leakage could lead to a potentially explosive atmosphere within the analyzer. Due to its high IP / Type rating, this mixture could not dilute or disappear, turning the internal volume into a Zone or Zone 0 and such voiding the analyzer Zone certification. Infallible Containment An infallible thermal conductivity detector (TCD) containment, designed to meet the requirements of the pressurization standard EN IEC 60079-, protects against intentional leakage into the analyzer housing. This enables to treat the flammable gas as non-flammable, resulting in a simpler protection concept for the analyzer. Such a containment has successfully been tested by a thirdparty agency. To ensure the high level of protection, each containment is undergoing documented and traceable routine tests for overpressure and free-of-leakage production. A containment system is considered infallible, if it comprises pipes, tubes, or vessels made of metal, ceramic, or glass, which have no moving joints. Joints shall be made by welding, brazing, glass to metal sealing or eutectic methods. Clamping joints are acceptable, too. 7

X-STREAM XXF PGA-PDS-X-STREAM-XXF Product Data Sheet September 0 YouTube.com/user/RosemountAnalytical Twitter.com/RAIhome Analyticexpert.com Facebook.com/EmersonRosemountAnalytical AMERICAS Emerson Process Management Rosemount Analytical 0 West Little York, Suite 00 Houston, Texas 7700 USA Toll Free + 866 68 T + 7 96 8880 F + 7 66 87 GAS.CSC@Emerson.com EUROPE Emerson Process Management GmbH & Co. OHG Rosemount Analytical Industriestrasse 69 Hasselroth Germany T + 9 60 88 0 F + 9 60 88 09 GAS.CSC@Emerson.com MIDDLE EAST & AFRICA Emerson Process Management Emerson FZE Jebel Ali Free Zone Dubai, UAE P.O. Box 70 T + 97 8 800 F + 97 866 6 GAS.CSC@Emerson.com ASIA PACIFIC Emerson Process Management Asia Pacific Private Ltd Pandan Crescent Singapore 0 Singapore T + 6 777 8 F + 6 777 097 GAS.CSC@Emerson.com 0 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.