New Castle, DE USA. Lindon, UT USA. Hüllhorst, Germany. Shanghai, China. Beijing, China. Tokyo, Japan. Seoul, South Korea.

Similar documents
DISCOVER the WORLD S FINEST DYNAMIC MECHANICAL ANALYZER

DMA 2980 Dynamic Mechanical Analyzer

Thermal Analysis Excellence

exceptional DesiGn enhanced performance DMA 8000 Dynamic Mechanical Analyzer

Introduction to Dynamic Mechanical Testing for Rubbers and Elastomers. Mackenzie Geiger Applications Scientist September 6, 2017

DMA AS PROBLEM-SOLVING TOOL: CHARACTERIZATION OF PROPERTIES OF ELASTOMERS USING MASTER CURVES

Thermal Analysis Excellence

Dynamic Mechanical Analysis

Thermal Analysis Excellence

Thermal Analysis Excellence

tainstruments.com São Paulo, Brazil Mexico City, Mexico Montreal, Canada

Innovative Thermoplastic Elastomers with Functional Performance

Keysight T150 UTM. Universal Testing Machine. Data Sheet

The WORLD S FINEST line of THERMOGRAVIMETRIC ANALYZERS

Thermal Analysis Premium TMA/SDTA 2+ STAR e System Innovative Technology Versatile Modularity Swiss Quality

Applying dynamic mechanical analysis to research & development. for viscoelastic damping materials.

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETERS

Dynamic Shear Rheometer: DSR

DURABILITY OF PRESSURE SENSITIVE ADHESIVE JOINTS

Differential Scanning Calorimetry DSC 200 F3

7 Most Important Test Methods

APN029. The SER2 Universal platform for material testing. A.Franck TA Instruments Germany

Comparison of Energy Absorption Characteristics of Thermoplastic Composites, Steel and Aluminum in High-Speed Crush Testing of U-Beams

Keysight Technologies Laser Heated Tip and High Temperature Stage for G200 Nano Indenter. Data Sheet

Photo. Materials Testing for Manufacturers and Retailers

Detection and Quantification of Amorphous Content in Pharmaceutical Materials

Abstract. Introduction

IN-SITU-PULTRUSION STRUCTURAL THERMOPLASTIC FRP-PARTS

ME -215 ENGINEERING MATERIALS AND PROCESES

Process considerations to achieve optimum weld strengths of Wood Plastics Composites using advanced Vibration Welding technology

Rheological Techniques for Yield Stress Analysis

One-part moisture-curing elastic adhesive meeting UL94V-0 flammability standard

High Heating Rate DSC

Thermal Analysis. Application Handbook. Thermal Analysis of Polymers Selected Applications

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Relative humidity as a new parameter in rheological testing

Designing with Plastics

CEAST HDT Vicat Series. Thermo-Mechanical Systems

Summary: Questions of material data (aluminum, plastics) for thin walled cooling and climarisation parts

Joining of Dissimilar Automotive Materials

SHAPE MEMORY EFFECT OF A THERMOSET POLYMER AND ITS FIBER REINFORCED COMPOSITES

CHAPTER 3 OUTLINE PROPERTIES OF MATERIALS PART 1

BASE MATERIALS Through Assembly

Stress-Strain Behavior

New Evaluation Methods for Pressure Sensitive Adhesive (PSA) Tapes Used in the Semiconductor Industry

DMA Analysis of PVAc Latex Reinforced with Cellulose Nanofibrils

NPL Manual. Modelling Creep in Toughened Epoxy Adhesives

Chapter 8: Strain Hardening and Annealing

YIELD & TENSILE STRENGTH OF STEEL & ALUMINIUM USING MICROINDENTATION

Rate Dependency Plastic Modeling

T50 MODULE OPTIONS. 60 x 39 x 62cm

MECHANICAL AND THERMAL PROPERTIES OF CARBON/EPOXY NANOCLAY COMPOSITES EXPOSED TO SYNERGISTIC EFFECT OF UV RADIATION AND CONDENSATION

Chapter 14 Polymers CHAPTER 7 POLYMERIC MATERIALS. Ancient Polymer History. Rubber balls used by Incas Noah used pitch (a natural polymer) for the ark

EXTRUSION OF ELASTOMER FILM, EFFECTS OF ELASTOMER DESIGN ON CHILL ROLL STICKING

ELASTOMER DESCRIPTIONS

Tapes, Fasteners & Sealants. Product Information Guide. The right solutions. The right products.

3.5.7 Flow Through Simple Dies

Ultra High Molecular Weight Polyethylene (UHMWPE)

DSC differential scanning calorimeter (DSC)

DuPont Kapton HN POLYIMIDE FILM

Extrusion. Key Issues to Address. Lecture 2. Process. Process Variants. Process Analysis. Problem Solving

Bonding to different materials possible (multi-purpose). Sealing, molding and potting purpose. Items Units Results Testing Method Remarks

Achieving Ideal Coating & Laminate Properties Through Rheology. Dalton Echard -Rheology Specialist-

Thermal Analysis Excellence

Numerical Modeling of Slab-On-Grade Foundations

Optimizing Strain Gage Excitation Levels

Earthquake Design of Flexible Soil Retaining Structures

STYCAST 2850 FT. Technical Data. Two Component, Versatile Epoxy Encapsulant With High Thermal Conductivity

ROAR, the University of East London Institutional Repository:

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

RHEOLOGICAL PROPERTIES ROSAND RH7 & RH10 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

EDGE CHIPPING RESISTANCE USING MACROINDENTATION TESTING

Insulation Retrofit Options

Properties in Shear. Figure 7c. Figure 7b. Figure 7a

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

BEHAVIOR IMPROVEMENT OF FOOTINGS ON SOFT CLAY UTILIZING GEOFOAM

Ceramic and glass technology

Core Compressive Strength / Modulus. Humid Aging of Rigid Cellural Plastics

High Modulus Carbon Fibres in Super-Structural Compounds

AIRSTONE Mold Building System

Fluorosilicones in the Aerospace Industry Nathan Lipps, NuSil Technology

PERFORMANCE OF COMMERCIAL HOT-MELT ADHESIVES

Supplement. by WING SIEN FONG. October A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE MENLO PARK, CALIFORNIA

TA INSTRUMENTS THERMOGRAVIMETRIC ANALYZERS

LABORATORY MODULE UNCONFINED COMPRESSION OF HYDROGEL DISKS

DNVGL-CP-0086 Edition March 2016

CB x 33 x 70 cm

MatSE 259 Exam 4 Review Session

TPS Thermo Plastic Spacer

HFM Heat Flow Meter Thermal Conductivity Analyzer

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

ANALYSIS OF TEMPERATURE INFLUENCE ON INJECTION MOLDING PROCESS

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

Application Note #124 VITA: Quantitative Nanoscale Characterization and Unambiguous Material Identification for Polymers

INTEGRATED FINITE ELEMENT ENVIRONMENT FOR COMPOSITE PROCESS SIMULATION

DESIGNING WITH WAVY COMPOSITES

Limitations of Test Methods for Plas tic s

Gage Series Stress Analysis Gages

Transcription:

THERMAL ANALYSIS

New Castle, DE USA Lindon, UT USA Hüllhorst, Germany Shanghai, China Beijing, China Tokyo, Japan Seoul, South Korea Taipei, Taiwan Bangalore, India Sydney, Australia Guangzhou, China Eschborn, Germany Wetzlar, Germany Brussels, Belgium Etten-Leur, Netherlands Paris, France Elstree, United Kingdom Barcelona, Spain Milano, Italy Warsaw, Poland Prague, Czech Republic Sollentuna, Sweden Copenhagen, Denmark Chicago, IL USA São Paulo, Brazil Mexico City, Mexico Montreal, Canada

Thermal Analysis Thermal Analysis is important to a wide variety of industries, including polymers, composites, pharmaceuticals, foods, petroleum, inorganic and organic chemicals, and many others. These instruments typically measure heat flow, weight loss, dimension change, or mechanical properties as a function of temperature. Properties characterized include melting, crystallization, glass transitions, cross-linking, oxidation, decomposition, volatilization, coefficient of thermal expansion, and modulus. These experiments allow the user to examine end-use performance, composition, processing, stability, and molecular structure and mobility. All TA Instruments thermal analysis instruments are manufactured to exacting standards and with the latest technology and processes for the most accurate, reliable, and reproducible data available. Multiple models are available based on needs; suitable for high sensitivity R&D as well as high throughput quality assurance. Available automation allows for maximum unattended laboratory productivity in all test environments. As the world leader in Thermal Analysis for over 50 years, TA Instruments brings technical expertise in thermal analysis measurements and provides a world-renowned global support network that is specialized in thermal analysis.

Dynamic Mechanical Analysis Accurate, Precise, Versatile DMA Measurements

Q800 dynamic mechanical analysis The Q800 is the world s best-selling DMA, for very good reason. It utilizes state-of-the-art, non-contact, linear drive technology to provide precise control of stress, and air bearings for low friction support. Strain is measured using optical encoder technology that provides unmatched sensitivity and resolution. With its unique design, the Q800 easily outperforms competitive instruments and is ideal for high-stiffness applications, including composites. Maximum Force 18 N Minimum Force 0.0001 N Force Resolution 0.00001 N Strain Resolution 1 nanometer Modulus Range 10 3 to 3x10 12 Pa Modulus Precision ± 1% Tan δ Sensitivity 0.0001 Tan δ Resolution 0.00001 Frequency Range 0.01 to 200 Hz Dynamic Sample Deformation Range ± 0.5 to 10 000 µm Temperature Range -150 to 600 C Heating Rate 0.1 to 20 C/min Cooling Rate 0.1 to 10 C/min Isothermal Stability ± 0.1 C Time/Temperature Superposition Yes RH Control Output Values Storage Modulus Complex/Dynamic Viscosity Time Loss Modulus Creep Compliance Stress/Strain Storage/Loss Compliance Relaxation Modulus Frequency Tan Delta (δ) Static/Dynamic Force Sample Stiffness Complex Modulus Temperature Displacement Relative Humidity ( ) Optional 56

deformation modes & sample size DMA Dual/Single Cantilever 3-Point Bend Tension Film/Fiber Fiber Shear Compression Submersion Tension Compression 3-Point Bend 8/4* mm (L), Up to 15 mm (W) and 5 mm (T) 20/10* mm (L), Up to 15 mm (W) and 5 mm (T) 35/17.5* mm (L), Up to 15 mm (W) and 5 mm (T) 5, 10, or 15 mm (L), Up to 15 mm (W) and 7 mm (T) 20 mm (L), Up to 15 mm (W) and 7 mm (T) 50 mm (L), Up to 15 mm (W) and 7 mm (T) 5 to 30 mm (L), Up to 8 mm (W) and 2 mm (T) 5 to 30 mm (L), 5 denier (0.57 tex) to 0.8 mm diameter 10 mm square, Up to 4 mm (T) 15 and 40 mm diameter, Up to 10 mm (T) Fixed at 15 mm (L), Up to 8 mm (W) and 2 mm (T) 25 mm diameter, Up to 10 mm (T) 5, 10, or 15 mm (L), Up to 15 mm (W) and 7 mm (T) *Lengths are for dual/single cantilever Dynamic Mechanical Analysis 57

sub-ambient operation DMA Gas Cooling Accessory The Gas Cooling Accessory (GCA) extends the operating range of the Q800 to -150 C. The GCA uses cold nitrogen gas generated from controlled evaporation of liquid nitrogen. Automated filling of the GCA tank can be programmed to occur after the scan is complete. The GCA will provide ballistic or controlled cooling rates over the entire operating range of the Q800 DMA (-150 to 600 C). In general, the maximum cooling rate is a function of the installed clamp and the thermal characteristics of the sample. The figure to the right shows the typical range* of controlled cooling rates available as a function of temperature. *Actual performance may vary slightly depending on laboratory conditions and the clamping system installed. Nitrogen Purge Cooler The Nitrogen Purge Cooler (NPC) is an innovative alternative for low temperature testing with the Q800 DMA. The NPC provides crash-cooling and controlled heating at temperatures as low as -160 C with all testing geometries. It is also an ideal choice for minimizing the cool-down time between consecutive experiments. A 2.5 L liquid-nitrogen filled dewar with heat exchanger cools nitrogen gas (2 bar to 8 bar, 30 L/min) before being fed to the Q800 oven. The NPC is a small, economical, and effective option for laboratories that have basic cooling requirements. 58

ACS-3 Air Chiller System The new Air Chiller System, ACS-3, is a unique gas flow cooling system that enables the Q800 to operate at temperatures as low as -100 C. Equipped with a three-stage cascading compressor design, the ACS-3 allows for low temperature environmental control without the use of liquid nitrogen. The ACS-3 can help eliminate or reduce liquid nitrogen usage and associated hazards from any laboratory and offers a tremendous return on investment. Rather than liquid nitrogen, the ACS-3 requires only compressed air (7 bar, 200 L/min) to provide controlled cooling. Small, quiet, and easy to use, the ACS-3 is a great addition to any laboratory that needs to conduct subambient or controlledcooling measurements, or simply wishes to shorten the time between experiments. Dynamic Mechanical Analysis 59

technology Q800 Drive Motor The Q800 uses a non-contact, direct drive motor to provide the oscillatory or static force required. The motor is constructed of high performance composites that ensure low compliance and is thermostated to eliminate heat build-up even when using large oscillation amplitudes and high deformation forces. Sophisticated electronics enable the motor current to be rapidly adjusted in small increments. The motor can deliver reproducible forces over a wide range and the force can be changed rapidly, enabling a broad spectrum of material properties to be measured. Air Bearings The non-contact drive motor transmits force directly to a rectangular air bearing slide. The slide is guided by eight porous carbon air bearings grouped into two sets of four near the top and bottom of the slide. Pressurized air or nitrogen flows to the bearings forming a frictionless surface that permits the slide to float. The slide, which connects to the drive shaft and sample clamp, can move vertically 25 mm and its rectangular shape eliminates any twisting of the sample. Very weak materials like films and fibers can be characterized with ease. Furnace The Q800 features a bifilar wound furnace with automated movement. The furnace design, combined with the Gas Cooling Accessory, provides for efficient and precise temperature control over the entire temperature range, both in heating, cooling, and isothermal operation. The automatic furnace movement simplifies experimental setup. Optical Encoder A high-resolution linear optical encoder is used to measure displacement on the Q800 DMA. Based on diffraction patterns of light through gratings (one moveable and one stationary), optical encoders provide exceptional resolution compared to typical LVDT technology. Due to the excellent 1 nanometer resolution of the optical encoder, very small amplitudes can be measured precisely. This, combined with the non-contact drive motor and air bearing technology, provides excellent modulus precision and high tan δ sensitivity allowing the Q800 DMA to characterize a broad range of materials. Low Mass, High Stiffness Sample Clamps The Q800 features a variety of sample clamps that provide for multiple modes of deformation. The clamps are optimized using finite element analysis to provide high stiffness, with low mass, and attach to the drive shaft with a simple dovetail connection. The clamps are easy to use and adjust, and each is individually calibrated to ensure data accuracy. A broad range of samples can be analyzed. The high stiffness minimizes clamp compliance, and the low mass ensures rapid temperature equilibration. These simple, yet elegant designs reduce the time necessary to change clamps and load samples. Rigid Aluminum Casting The Q800 drive motor, air bearing slide assembly with optical encoder and air bearings are all mounted within a rigid aluminum casting that is temperature controlled. The rigid aluminum housing minimizes system compliance and the temperature-controlled housing ensures precise data. 60

Furnace Low Mass, High Stiffness Sample Clamps Air Bearings Rigid Aluminum Casting Drive motor Optical Encoder Dynamic Mechanical Analysis 61

modes of deformation Q800 Dual/Single Cantilever 3-Point Bend Shear Sandwich Dual/Single Cantilever In this mode, the sample is clamped at both ends and either flexed in the middle (dual cantilever) or at one end (single cantilever). Cantilever bending is a good general-purpose mode for evaluating thermoplastics and highly damped materials (e.g., elastomers). Dual cantilever mode is ideal for studying the cure of supported thermosets. A powder clamp is also available for characterizing transitions in powder materials. 3-Point Bend In this mode, the sample is supported at both ends and force is applied in the middle. 3-point bend is considered a pure mode of deformation since clamping effects are eliminated. The 50 and 20 mm clamps on the Q800 utilize unique low-friction, roller bearing supports that improve accuracy. Shear Sandwich In this mode, two equal-size pieces of the same material are sheared between a fixed and moveable plate. This mode is ideal for gels, adhesives, high viscosity resins, and other highly damped materials. 62

Compression Tension Submersible Clamps Compression In this mode, the sample is placed on a fixed flat surface and an oscillating plate applies force. Compression is suitable for low to moderate modulus materials (e.g., foams and elastomers). This mode can also be used to make measurements of expansion or contraction, and tack testing for adhesives. Tension In this mode, the sample is placed in tension between a fixed and moveable clamp. In oscillation experiments, the instruments use a variety of methods for applying a static load to prevent buckling and unnecessary creep. The clamps are suitable for both films and fibers. Submersible Clamps Film tension, compression, and 3-point bend clamps are available in submersible configurations for the Q800. These clamps allow samples to be analyzed in a fluid environment up to 80 C. Dynamic Mechanical Analysis 63

accessories Q800 DMA-RH The new DMA-RH Accessory allows mechanical properties of a sample to be analyzed under controlled and/or varying conditions of both relative humidity and temperature. It is designed for use with the Q800 Dynamic Mechanical Analyzer. The DMA-RH accessory offers the widest range of temperature and relative humidity. Temperature Range 5 to 120 C Temperature Accuracy ±0.5 C The DMA-RH Accessory is a fully integrated unit and includes the following hardware components: 1 The sample chamber mounts to the DMA in place of the standard furnace. Peltier elements in the chamber precisely control the temperature to ±0.1 C. The sample chamber accommodates standard DMA clamps (tension, cantilever, and 3-point bending). It is quickly removed for conversion back to the standard DMA furnace. Heating/Cooling Rate Humidity Range Humidity Accuracy Humidity Ramp Rate (both increasing and decreasing) Maximum ±1 C/min See humidity range chart. 5-90% RH: ±3% RH >90% RH: ±5% RH 2% RH/min (fixed) 2 A heated vapor-transfer line is maintained at a temperature above the dew point temperature of the humidified gas in order to avoid condensation and provide accurate results. 3 The DMA-RH Accessory contains the humidifier and electronics which continuously monitor and control temperature and humidity of the sample chamber. Relative Humidity (%) 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Temperature ( C) 64

1 2 3 Dynamic Mechanical Analysis 65

DMA-RH applications Q800 Effect of Relative Humidity on the Glass Transition of Nylon 6 Nylon 6 is strongly plasticized by water; as such the mechanical properties will be dependent on the surrounding relative humidity. The data in this figure demonstrate the effect of relative humidity on the glass transition of Nylon 6 as measured on the Q800 DMA equipped with the DMA-RH accessory. The sample was analyzed in single cantilever mode at a frequency of 1 Hz at a variety of constant RH conditions. Note how the mechanical properties and glass transition are significantly influenced by the imposed relative humidity. Storage Modulus (MPa) 4000 2000 0-2000 31.99 C 49.44 C 61.08 C 67.49 C 80% RH 50% RH 20% RH 50% RH 0.28 0.24 0.20 0.16 0.12 0.08 0.04-4000 0 20 40 60 80 100 0.00 [ ] Tan Delta Temperature ( C) Measurement of the Coefficient of Hygroscopic Expansion (CHE) Hygroscopy is defined as the ability of a substance to attract water molecules from the surrounding environment through either absorption or adsorption. The effect of moisture sorption on the mechanical characteristics of a material can be quantified by the Coefficient of Hygroscopic Expansion (CHE), the constant which relates the dimensional change of a material to a change in the surrounding relative humidity. The data in this figure show the effect of imposed relative humidity on the Nylon 6 sample as measured by the Q800 DMA with the DMA-RH Accessory. As the relative humidity is increased the sample expands. The resulting slope of the line is equivalent to the CHE for the material. 1500 1000 500 0 0 20 40 60 80 100 Relative Humidity (%) 66

Relaxation Modulus (MPa) 1000 0.5% Strain 25 C/50% RH 100 85 C/85% RH 0 1 10 100 1000 10000 Decay Time (sec) Stress Relaxation of Nafion 112 Under Varying Temperature/RH Conditions Recent research has focused on alternative fuel technologies including Proton Exchange Membrane Fuel Cells (PEMFC) which contain polymeric membranes such as Nafion* 112. PEM properties can significantly change as functions of time and exposure to elevated temperatures and humidity, as water is the primary by-product of the electrochemical reaction of the fuel cell. The Q800 DMA equipped with the DMA-RH accessory is the ideal platform to study the effect of temperature and humidity on the time-dependent processes of the PEM. In this example, the stress relaxation behavior of a Nafion 112 membrane is analyzed in tension mode under two discrete conditions; 25 C/50% RH (controlled ambient) and under elevated temperature and RH conditions of 85 C/85% RH. *Nafion is a registered trademark of DuPont Co. Storage Modulus (MPa) 10000 0.5 83.46% 93.63% 0.4 1000 0.25% RH/min 0.3 100 0.2 10 1 0 25 C 40 C 20 40 60 80 0.1 0.0 100 [ ] Tan Delta Analysis of a Pharmaceutical Gelatin Capsule Gelatin capsules are widely used in the pharmaceutical and dietary supplement market. When stored in an ambient, low-humidity environment gelatin is remarkably stable. However, when combined with water, gelatin forms a semi-solid colloid gel which can profoundly affect its mechanical properties. The data in this example illustrate the effect of increasing relative humidity on a gelatin sample cut from the side wall of a two-piece capsule at 25 C and 40 C. As the relative humidity is increased, the material undergoes a multi-step transition resulting in a significant decrease in modulus near 80% RH. The transition is resolved in both the storage modulus and tan d signals. Relative Humidity (%) Dynamic Mechanical Analysis 67

theory DMA Range of Material Behavior Solid Like Liquid Like Ideal Solid Most Materials Ideal Fluid Purely Elastic Viscoelastic Purely Viscous Viscoelasticity: Having both viscous and elastic properties Figure 1 δ=0 Strain Strain δ=90 Dynamic Mechanical Analysis (DMA) is a technique used to measure the mechanical properties of a wide range of materials. Many materials, including polymers, behave both like an elastic solid and a viscous fluid, thus the term viscoelastic. DMA differs from other mechanical testing devices in two important ways. First, typical tensile test devices focus only on the elastic component. In many applications, the inelastic, or viscous component, is critical. It is the viscous component that determines properties such as impact resistance. Second, tensile test devices work primarily outside the linear viscoelastic range. DMA works primarily in the linear viscoelastic range and is therefore more sensitive to structure. DMA measures the viscoelastic properties using either transient or dynamic oscillatory tests. The most common test is the dynamic oscillatory test, where a sinusoidal stress (or strain) is applied to the material and a resultant sinusoidal strain (or stress) is measured. Also measured is the phase difference, δ, between the two sine waves. The phase lag will be 0 for purely elastic materials and 90 for purely viscous materials (Figure 1). However, viscoelastic materials (e.g. polymers) will exhibit an intermediate phase difference (Figure 2a). Stress 100% Elastic Behavior Figure 2a 0 <δ<90 Strain Stress 100% Viscous Behavior Figure 2b E* E δ E Since modulus equals stress/strain, the complex modulus, E*, can be calculated. From E* and the measurement of δ, the storage modulus, E, and loss modulus, E, can be calculated as illustrated in Figure 2b. The storage modulus (E ) is the elastic component and related to the sample s stiffness. The loss modulus (E ) is the viscous component and is related to the sample s ability to dissipate mechanical energy through molecular motion. The tangent of phase difference, or tan δ, is another common parameter that provides information on the relationship between the elastic and inelastic components. Transient tests include creep and stress relaxation. In creep, a stress is applied to the sample and held constant while deformation is measured vs. time. After some time, the stress is removed and the recovery is measured. In stress relaxation, a deformation is applied to the sample and held constant, and the degradation of the stress required to maintain the deformation is measured versus time. 68 Stress Viscoelastic Behavior E* = Stress*/Strain E = E* cosδ E = E* sinδ tan δ = E /E

modes of operation DMA % Strain/Stress Multi-Frequency Time Multi-Frequency The multi-frequency mode can assess viscoelastic properties as a function of frequency, while oscillation amplitude is held constant. These tests can be run at single or multiple frequencies, in time sweep, temperature ramp, or temperature step/hold experiments. % Strain/Stress Multi-Stress/Strain Multi-Stress/Strain In this mode, frequency and temperature are held constant, and the viscoelastic properties are monitored as strain or stress is varied. This mode is primarily used to identify the Linear Viscoelastic Range (LVR). Strain/Stress Creep/Stress Relaxation Creep/Stress Relaxation With creep, the stress is held constant and deformation is monitored as a function of time. In stress relaxation, the strain is held constant and the stress is monitored vs. time. Strain/Stress T 1 T 1 Time Controlled Force/Strain Rate Controlled Force/Strain Rate In this mode, the temperature is held constant while stress or strain is ramped at a constant rate. This mode is used to generate stress/strain plots to obtain Young s Modulus. Alternatively, stress can be held constant with a temperature ramp while strain is monitored. Time Isostrain Isostrain Strain In isostrain mode, available on the Q800, strain is held constant during a temperature ramp. Isostrain can be used to assess shrinkage force in films and fibers. Temperature Dynamic Mechanical Analysis 69

applications Q800 10000 1000 Tg by E Onset -30.60 C Tg by Tan Delta Peak -2.04 C 2.0 10000 1000 Measurement of Tg of Polymeric Materials A common measurement on polymers is the glass transition temperature, Tg. It can be measured with various techniques, but DMA is by far the most sensitive. The figure to the right shows a scan of a pressure sensitive adhesive run in the tension clamps at a frequency of 1 Hz. Tg can be measured by the E onset point, by the E peak, or the peak of Tan δ. In addition to the Tg, the absolute value of the various viscoelastic parameters is also useful. Storage Modulus (MPa) 100 10 1 0.1 0.01-100 Tg by E Peak -28.58 C -75-50 -25 Tan Delta 1.5 1.0 0.5 100 10 0.01 0 25 50 75 100 125 Temperature ( C) 1 0.1 Loss Modulus (MPa) Frequency Effect on Modulus and Glass Transition of Polyethylene Terephthalate (PET) Because the Tg has a kinetic component, it is strongly influenced by the frequency (rate) of deformation. As the frequency of the test increases, the molecular relaxations can only occur at higher temperatures and, as a consequence, the Tg will increase with increasing frequency as illustrated to the right. In addition, the shape and intensity of the Tan δ peak as well as the slope of the storage modulus in the transition region will be affected. Based on end-use conditions, it is important to understand the temperature and frequency dependence of transitions. Storage Modulus (MPa) 5000 4000 E at 10 HZ Tg at 0.1 HZ 103.00 C Tg at 10 HZ 113.25 C 0.20 0.15 3000 E at 0.1 HZ 0.10 2000 Tan Delta at 0.1 HZ 0.05 1000 Tan Delta at 10 Hz 0 0.00 20 40 60 80 100 120 140 160 Temperature ( C) Tan Delta 100000 The Measurement of Secondary Transitions in Vinyl Ester DMA is one of the few techniques sensitive to β and γ secondary transitions. Secondary transitions arise from side group motion with some cooperative vibrations from the main chain as well as internal rotation within a side group. The transitions are below the Tg and typically subambient. They are very important as they affect impact resistance and other end-use properties. This data was generated using 3-point bending and also illustrates the ability to run stiff composites. Storage Modulus (MPa) 10000 1000 γ Relaxation -89.55 C 100-150 -100-50 0 β Relaxation 101.27 C Tg 200.72 C 50 100 150 200 250 300 Temperature ( C) 0.09 0.08 0.07 0.06 0.05 0.04 0.03 Tan Delta 70

Storage Modulus (Pa) 10 10 10 9 10 8 10 7 10 6 Frequency = 6.28 1 Hz Uncoated Good Coating Poor Coating E' Tan Delta 10 2 10 1 10 0 10-1 10-2 Tan Delta Measuring Effect of Adhesive Coatings on Films This figure shows a comparison among three PET samples in tension on the DMA; one with a uniform adhesive layer that performs well, one with a non-uniform layer that performs poorly, and one that is uncoated. A transition peak due to the adhesive is seen in Tan δ around 40 C in the good sample, whereas the poor sample shows a much smaller peak. Knowing the characteristics of good and poor samples enables quality control of the coating process and the finished product. 10 5 10-3 -90-60 -30 0 30 60 90 120 150 180 210 Temperature ( C) Storage Modulus (MPa) 12000 10000 8000 6000 4000 2000 10401 MPa 9589 MPa PCB As Received PCB Post Baked 142.70 C 141.84 C 2000 15000 1000 500 Loss Modulus (MPa) Characterizing Printed Circuit Boards Printed Circuit Boards (PCB) are typically comprised of fiberglass braid impregnated with a thermosetting resin. Characterizing the Tg of PCB s is often difficult due to the very low amount of resin used. This figure shows a typical PCB run in single cantilever bending. The Tg is clearly discernible and the difference between the sample as received and post baked clearly shows the effect that further crosslinking has on both the Tg and the absolute value of modulus. 0 40 0 60 80 100 120 140 160 180 200 Temperature ( C) 10 10 10 Storage Modulus (Pa) 10 9 10 8 10 7 10 6 SBR SBR + Carbon Black 10 5 0.001-80 -65-50 -35-20 Temperature ( C) 1 0.1 0.01 Tan Delta Effect of Carbon Black in Elastomers Another very common application is the effect of fillers and additives on viscoelastic properties. The figure to the left illustrates the effect on storage modulus (E ) and Tan δ when adding carbon black to an SBR rubber. This test, performed in dual cantilever on the DMA, shows that adding carbon black increases the absolute value of the storage modulus and significantly increases the Tg temperature. Understanding how fillers and additives affect material properties is crucial in many industrial applications. Dynamic Mechanical Analysis 71

applications Q800 Characterizing Packaging Films Using Creep In a thermoforming process, a film is pulled down into a heated mold to form a desired shape. The ability to produce a stable product can be predicted by using a creep-recovery experiment. This figure illustrates data on a packaging film using the tension mode. In the recovery phase, the equilibrium recoverable compliance, (J er ) can be calculated. If the sample compliance is too high, as observed by a high J er, then the elasticity may be too low at the forming temperature to maintain the desired shape. Strain (%) 10 8 6 4 2 8.944% 5.520% 3.466% J er =2.89 E-8 Pa -1 Good (PTFE/PP) Poor (PTFE/PP) Excellent (PTFE/PP/PE) J er =2.43 E-8 Pa -1 J er =8.86 E-9 Pa -1 0 0 5 10 15 20 25 30 35 Time (min) Predicting Material Performance Using Time/ Temperature Superpositioning (TTS) The TTS technique, well-grounded in theory, is used to predict material performance E' Master Curve at frequencies or time scales outside the range of the instrument. Data is usually Tr=75 C generated by scanning multiple frequencies during a series of isothermal step-hold 10 9 experiments over a temperature range. A reference temperature is selected and the data shifted. A shift factor plot is generated and fit to either a Williams-Landel- Ferry (WLF) or Arrhenius model. Finally, a master curve at a specific temperature is generated as illustrated to the right for a PET film sample. Using this technique, properties at very high frequencies (short time scales) or very low frequencies 10 8 (long time scales) can be assessed. 10-15 10-8 10-1 10 6 10 13 10 20 Frequency (Hz) Storage Modulus (Pa) 10 10 72

NOTES

tainstruments.com 2014 TA Instruments. All rights reserved. L90020.001