Magnum Board Section Digicon Information Inc. Page 1

Similar documents
Magnum Board Section Digicon Information Inc. Page 1

SPECIFICATION GUIDELINE

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

SPECIFICATION GUIDELINE

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION GYPSUM BOARD

Gold Bond BRAND Gypsum Sheathing

BEARING METAL STUD FRAMING

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION MANUFACTURED MASONRY VENEER

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

SECTION GYPSUM BOARD ASSEMBLIES

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Stonecraft Industies 8300 County Road Holmesville, OH

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

by Rollfab Metal Products

LUX Specifications. Section S - Preformed Steel Siding

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

MASTERFORMAT SPECIFICATION

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

The purpose of this memo is to respond to the comments received in response to the May 1, 2007, staff letter and the revised criteria.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

MASTER GUIDE SPECIFICATION

ROCKWOOL Board Insulation Section Master Guide Specification (ROCKBOARD 80) Page 1 January 2017

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

Editing notes to assist users are separated from specification text by rows of asterisks. Delete these notes prior to final printing.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Product Guide Specification

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

SECTION ROOF SPECIALTIES

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

SECTION MANUFACTURED STONE VENEER. A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials.

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

SECTION SPRAY APPLIED WALL COVERING ADHESIVE

ROXUL Blanket (and Batt) Insulation Section Master Guide Specification (AFB) Page 1 April 2015

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION QUARTZ SURFACING COUNTERTOPS

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

CS-100 Guide Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION RESILIENT SHEET FLOORING

SECTION UNIT MASONRY SYSTEM

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION EXTERIOR GRILLS AND SCREENS

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

ROCKWOOL Blanket (and Batt) Insulation Section Master Guide Specification Page 1 Jan 2017

SECTION COLD-FORMED METAL FRAMING

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

ACFoam-II HCFC Free "Green" Polyiso Specification

Dricon FRT Wood Specification

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

PRODUCT SPECIFICATIONS

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION CERAMIC TILE. B. Ceramic tile wall finishes including standard and custom designs.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

TECHNICAL INFORMATION

MANUFACTURER S SPECIFICATION

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

ROXUL Roof and Deck Insulation Section Master Guide Specification Page 1 April 2016

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

STORAGE AND TRANSPORTION

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

SECTION GYPSUM BOARD

CENTRIA FORMABOND II Metal Composite Wall System

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

EcoTouch Insulation with PureFiber Technology

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

SECTION NON-STRUCTURAL METAL FRAMING

CSI GUIDE Countertops

Transcription:

Digicon Information Inc. Page 1 This section includes water and mould resistant fibre-reinforced backer board for use under tile installations, suitable for use in wet areas. This section includes performance, proprietary and descriptive type specifications; edit text to avoid conflicting requirements. Part 1 General 1.1 SECTION INCLUDES In this article, select the components or assemblies that are intended to be part of the content of this section and will not be included in other sections..1 Magnesium oxide backer boards for [interior][wet area] tile applications. 1.2 RELATED SECTIONS In this article, indicate those sections that inter-rely on this section. The listing below is only partial and should be edited to include those sections specific to the project that describe subjects or products that affect this section directly..1 Section 06 11 00 - Wood Framing: Building wood framing assembly with openings for windows and doors..2 Section 06 10 13 - Wood Blocking and Curbing: Wood blocking for support of [ ]..3 Section 07 14 00 - Fluid-Applied Waterproofing..4 Section 09 22 13 - Metal Furring And Lathing..5 Section 09 22 16 - Non-structural Metal Stud Framing..6 Section 09 30 11 - Ceramic Wall Tiling. 1.3 REFERENCES Edit this article after editing the rest of this section. Only list reference standards below, that are included within the text of this section, when edited for a project specification delete other references that do not apply..1 International Code Council Evaluation Service Inc. (ICC-ES).1 Acceptance Criteria AC386 for Fiber-Reinforced Magnesium-Oxide-Based Sheets..2 ASTM C1185-08(2012) - Standard Test Methods for Sampling and Testing Non- Asbestos Fiber-Cement Flat Sheet, Roofing and Siding Shingles, and Clapboards..3 ASTM C1186-08(2012) - Standard Specification for Flat Fiber-Cement Sheets..4 ASTM C1325-08b - Standard Specification for Non-Asbestos Fiber-Mat Reinforced Cementitious Backer Units..5 ASTM E72-13a - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction.

Digicon Information Inc. Page 2.6 ASTM E84-13a - Standard Test Method for Surface Burning Characteristics of Building Materials..7 ASTM E119-12a - Standard Test Methods for Fire Tests of Building Construction and Materials..8 ASTM G21-13 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi..9 UL 263 - Fire Tests of Building Construction and Materials 2011. 1.4 SUBMITTALS FOR REVIEW Do not request submittals if this specification section or drawings sufficiently describe the products of this section or if proprietary specifying is used. The following submittals are intended for review to determine eligibility for the project..1 Section 01 33 00: Submission procedures..2 Product Data: Provide product data on [magnesium oxide backer board][waterproofing] [metal framing]..3 Shop Drawings: Indicate fastener type and spacing to suit framing details. Use the following paragraph for submission of physical samples for selection of finish, colour, texture, etc..4 Samples: Submit [two (2)] samples, [<[ ] mm><<[ ] inches>>] in size. 1.5 SUBMITTALS FOR INFORMATION The following submittals are for information only; do not request these submittals if the information submitted will be assessed for acceptability..1 Section 01 33 00: Submission procedures..2 Installation Data: Manufacturer's special installation requirements. Include the following ONLY if specifying for a LEED project. Specify only the technical requirements necessary to achieve the credits desired for this project..3 Sustainable Design:.1 Section 01 35 18: LEED documentation procedures..2 Provide required LEED documentation for Product [recycled content] [regional materials]..3 Manufacturer's Certificate: Certify that Products meet or exceed [specified requirements]. 1.6 CLOSEOUT SUBMITTALS The following submittals are for project closeout purposes; do not request these submittals if the information submitted will be assessed for acceptability..1 Section 01 78 10: Submission procedures. Include the following ONLY if specifying for a LEED project.

Digicon Information Inc. Page 3.2 Sustainable Design Closeout Documentation: [ ]. 1.7 QUALITY ASSURANCE This article includes statements that require quality applicable to the whole section..1 Perform Work in accordance with manufacturer s written instructions and Technical Bulletin No. 090508-1545..2 Applicator Qualifications: Company specializing in performing the work of this section with minimum [three (3)] years documented experience [and approved by the manufacturer]. 1.8 DELIVERY, STORAGE AND HANDLING.1 Section 01 61 00: Transport, handle, store, and protect products..2 Protect materials from warping or other distortion by stacking in flat sheets, off the ground..3 Protect stockpiled materials from weather using waterproof tarps. Part 2 Products 2.1 MANUFACTURERS This article is for proprietary specifying with one or more manufacturers. Use the first and third paragraphs for specifying a single manufacturer. If specifying a product by reference to a standard only, delete this article. Additional manufacturer s data can be found at http:// www.magnumbp.com..1 Magnum Building Products, LLC.1 10150 Highland Manor Drive, Suite 200.2 Tampa, Florida.3 33610.4 Tel: (813) 314-2202.5 Fax: (813) 314-2203.6 Web: www.magnumbp.com.2 Other acceptable manufacturers offering functionally [and aesthetically] equivalent products..1 [ ]; Product: [ ]..2 [ ]; Product: [ ]..3 [ ]; Product: [ ]..3 Substitutions: [Not permitted] [Refer to Section 01 62 00]. 2.2 MATERIALS Include the following paragraphs for magnesium oxide sheathing not specified in other sections such as the roof deck preparation part of relevant sections in Division 07.

Digicon Information Inc. Page 4 Non-fire rated Magnum Board is available in panel thicknesses from 3 mm (1/8 inch) to 25 mm (1 inch) and 1220 mm (4 feet) width x 2440 mm, 2745 mm, 3050 mm and 3660 mm (8, 9, 10 and 12 feet) lengths. Fire rated Magnum Board is only available in 12 mm (15/32 inch) panel thickness and 1220 mm (4 feet) width x 2440 mm, 2745 mm, and 3050 mm (8, 9, and 10 feet) lengths..1 Magnesium Oxide Backer Board: Fibre-reinforced homogeneous panel, paperless, moisture resistant; maximum available length in place ends square cut, square edges..1 Regular, non-fire rated, [<3 mm><<1/8 inch>>] [<13 mm><<1/2 inch>>] [<16 mm><<5/8 inch>>] [<25 mm><<1 inch>>] [<[ ] mm><<[ ] inch>>] thick..2 Fire rated, <12 mm><<15/32 inch>> thick. 2.3 FRAMING MATERIALS This article is to identify wood or metal framing substrates to which the sheathing is to be applied..1 Metal Framing and Accessories: Specified in Section [09 22 13] [09 22 16]..2 Wood Framing: Specified in Section [06 11 00] [06 10 13]. 2.4 COMPONENTS.1 Tile Finish: Section 09 30 11..2 Waterproofing Membrane: Section 07 14 00. 2.5 ACCESSORIES.1 Fastening: Corrosion resistant [self-tapping screws] [pneumatic nails] [adhesive] as recommended by manufacturer. Part 3 Execution 3.1 EXAMINATION.1 Section 01 70 00: Verify existing conditions before starting work..2 Verify that site conditions are ready to receive work and opening dimensions are as [instructed by the manufacturer] [indicated on shop drawings]. 3.2 SHEATHING INSTALLATION.1 Install in accordance with manufacturer s written instructions.2 Coordinate location of openings and through-wall components with other work..3 Coordinate installation with application of waterproofing membrane by Section [07 14 00]..4 Erect magnesium oxide backer board [vertically] [horizontally], with edges butted tight and ends occurring over firm bearing..5 Use screws when fastening magnesium oxide backer board to furring or framing..6 Treat cut edges and holes in sheathing with sealant.

Digicon Information Inc. Page 5 3.3 ERECTION TOLERANCES Do not assume that there are industry standards for tolerances. Specify tolerances below as appropriate to the nature or character of the project. Verify that such tolerances are realistic and realizable..1 Section 01 73 00: Tolerances..2 Maximum Variation of Magnesium Oxide Backer Board Surface from True Flatness: [<6 mm in 3 m><<1/4 inch in 10 ft>>] in any direction. END OF SECTION