FLEXIBLE DUCT CONNECTORS

Similar documents
SECTION HVAC INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS

K-FLEX. K-FLEX Tapes. for HVAC and industrial application

TABLE OF CONTENTS. productgroep 69

S OZ. WOVEN POLYETHYLENE F. R. S-3 KLEAR SPAN FR S-6 18 OZ. VINYL COATED POLYESTER (VCP) INNOVATIVE SOLUTIONS PRECISION RELIABILITY

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Custom Canopies Intl. Inc.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

SECTION HVAC DUCTS AND CASINGS

High Temperature Fabrics and Blankets for the Insulation Industry

Luka Quality Assurance Manual (Eng)

SUNSHADOW NET SERIES SUNSHADOW NET SERIES. Composition: 25% Polyester 75% PVC

Fabrics for Flexible Connections

GUIDE SPECIFICATION: DUCT LINER

Floor Insulation Underlayment Section Sound Control Matting

Impermeability and luminosity

Offering the best price-performance in the industry. 1 (800) Presto Tape is a proud USA Manufacturer.

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

3M Electrical, Electronic and EMI Shielding Tapes Selection Guide

Technical Guide. Adhesive Tapes

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Pultruded Grating/Treads and Fabrications REVISED

CONVEYOR BELTS FICHE TECHNIQUE AIRPORT \ CONVEYOR BELTS PROOSED

Fire Barrier Duct Wrap 615+

Choice of darkening level

Part of the Sikaplan WT Membrane System

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION PRE-ENGINEERED BUILDING INSULATION

ENKASONIC FLOOR UNDERLAYMENT 9110

Sika Tricomer Compression Seals

Part of the Sikaplan WT Membrane System

FRP Floor Panels Standard Specification

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

a gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Lake Park, GA Coats, NC

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

TRIAD CORRUGATED METAL, INC.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

Sunscreens & Rollershades

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Hollow Core Building Panels Products and Fabrications REVISED 11.

Section BUILDINGS, SHELTERS, ENCLOSURES

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016

Signature Sports Flooring (Economy I Series Wall Padding) WPE1-XX Safety Wall Padding

FACADE PROFILES FOR VERSATILE APPLICATIONS 01/16

1-part elastic joint sealant and multipurpose adhesive

Silica Slit Gasket & Thermal Insulating Tape 1800 F / 982 C: InSilMax Extreme High Temperature, Heat, Flame, Molten Metal & Weld Splatter Resistant

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

UTILUX CABLE MANAGEMENT

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

Non-rigit-PVC. Soft PVC strips

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Molded Grating and Treads Products and Fabrications REVISED 11.

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

Design & Construction Standards, Revised January

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

3M Electromagnetic Compatible Products

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

OEM ACOUSTICAL PRODUCTS

GABIONS AND REVET MATTRESSES

SECTION (15081) - HVAC INSULATION

IMP INNOVATION MANAGEMENT PROFESSIONAL ABOUT US

Spark and spatter. Sparks and spatter cause risk of fire and damage. Cepro welding blankets and grinding curtains offer secure separation.

Hygienic Fire Doors Complete Solutions

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

OptiLiner Banded Liner System, Thermal, Metal Building

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

SCREEN NATURE ULTIMETAL

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Hygienic Cladding Solutions. White, Pastel & Vibrant Colours. Satin & Gloss Ranges

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... BROCHURE 2017

SECTION METAL ROOF PANELS

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

FlexClad Duct and Pipe Sealing System

Vinaflex Noise Reduction Materials Insulation Innovation

Page 1 of 5 PART 1 GENERAL

PROFESSIONAL BONDING SOLUTIONS

SUNWORKER OPAQUE. Blackout awning, the cost-effective alternative. to rolling shutters

Elastic One-component Adhesives and Sealants. flexible strong durable

Pattern-Design Modified Bitumen Cap Sheets

Thermasheath-XP. Insulation for Exposed Use

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct

CABLE MANAGEMENT SOLUTIONS

RTV133. Technical Data Sheet

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

FRANK Puddle Flanges. The Original. Geosynthetics

RTV627 Flame Retardant Silicone Rubber Compound

INSTALLATION INSTRUCTIONS KÖSTER TPO

PALIGHT. Flat Foamed PVC Sheet. CREATING SOLUTIONS

SECTION AIR DUCT CLEANING

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

Sample Specification

FABRIC EXPANSION JOINTS. Technical Brochure

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

PROFILE S6 CORRUGATED SHEETS

Transcription:

FLEXIBLE DUCT CONNECTORS PRODUCT CATALOG

1 PERFECT SOLUTION FOR NOISES AND VIBRATIONS All air duct installations for heating or ventilation are attached to mechanical equipment containing a fan or blower. This equipment causes vibrations and noises which are transmitted in the metal ducts throughout the installation. In order to isolate vibrations and noises caused by air handling units, fans and other equipments, it is highly recommended to install an airtight flexible joint between the outlet of the device and the airduct. This joint, consisting of a fabric which is attached to a sheet of metal on both sides is called a «Flexible Duct Connector». It is necessary to select an airtight and flexible cloth with good weathering qualities and which can withstand temperatures inside and outside the duct. CLIM flexible connectors are perfect for this job. 2 FLEXIBLE DUCT CONNECTORS Clim offers two types of seam locks of metal-to-fabrics. Both gives a great strength, nothing comparable to classical singlefold methods. LOC4 for residential or light commercial applications LOC3 for industrial or commercial applications - All CLIM fabrics flexible duct connectors meet the British specifications for sheet metal ductwork DW/142 and DW/144. - All CLIM flexible duct connectors are manifactured in Europe (Belgium). - All CLIM flexible duct connectors are also available with 304 or 316 stainless steel on request. - All CLIM flexible duct connectors are manufactured with 24 or 28 ga. galvanized steel.

3 FABRICS TECHNICAL SPECIFICATION ROBG NEO SI PTFE ROX MATERIAL COATING PVC Polychloroprene Silicone Polytetrafluorethylene PVC CLOTH Polyester Fiberglass Fiberglass Fiberglass Polyester COATING Both sides Both sides Both sides On notched side Both sides WEIGHT 600 gr/sq m (18 oz/sq yd) 720 gr/sq m (21 oz/sq yd) 520 gr/sq m (15 oz/sq yd) 540 gr/sq m (16 oz/sq yd) 600 gr/sq m (18 oz/sq yd) TENSILE WRAP >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm STRENGTH WEFT >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm >=250 dan/5cm TEAR WRAP >=22 dan >=10 dan >=10 dan >=12 dan >=22 dan STRENGTH WEFT >=20 dan >=15 dan >=15 dan >=10 dan >=20 dan COLOUR Black Black Grey Golden brown Grey TEMPERATURE RANGE -20 C to +70 C -20 C to +100 C -40 C to +260 C -140 C to +260 C -20 C to +70 C (CONTINUOUS) RESISTANCE (-4 F to 158 F) (-4 F to 212 F) (-40 F to 500 F) (-220 F to 500 F) (-4 F to 158 F) ACIDS Very good Good Good Good Very good OILS Good Poor Poor Good Good SOLVENTS Fair Good Good Fair Fair GREASES Good Poor Poor Good Good OZON Very good Good Very good Good Very good UV Very good Fair Very good Good Very good ALOGEN Very good Poor Poor Good Very good - Excellent mechanical - Excellent high temperature - Excellent high temperature - Excellent high temperature - Excellent mechanical CARACTERISTICS - Excellent tear and tensile strength - All purpose - Flame retardant - Excellent water - «Hardly flammable» classified -Very good chemical - Very good low temperature - Very low smoke emission - Very good chemical - Black side 10 5 Ohms (surface resistivity) -Very good chemical - Excellent tear and tensile strength - All purpose - Flame retardant - Excellent water -Excellent ozone and weathering STANDARDS UL classified - NFPA 701 UL classified - NFPA 701 UL tested - NFPA 701 Not flammable according to DIN 4102 A2 - - All CLIM fabrics are unaffected by mildew. - All CLIM fabrics are designed to meet NFPA 90A (Installation of air conditioning and ventilating systems). - All CLIM fabrics are designed to meet NFPA 90B (Warm air heating and air conditioning systems). - All CLIM fabrics are airthight and waterproof. - All CLIM fabrics meet American, British, French, German and other european standards.

4 FLEXIBLE DUCT CONNECTOR TYPE «LOC4» 0,4 mm (28 ga.) steel thickness (European standard) A = thickness of steel : 0,4 mm (28 ga.) B = steel width C = fabric width L= length of roll : 25 m (82 feet) B C B Others lengths on request LOC4 B = STEEL WIDTH 28 mm 1-1/8 35 mm 1-3/8 45 mm 1-3/4 70 mm 2-3/4 C = FABRIC WIDTH 40 mm 1-9/16 60 mm 2-3/8 75 mm 3 100 mm 4 40 mm 1-9/16 60 mm 2-3/8 75 mm 3 100 mm 4 60 mm 2-3/8 75 mm 3 100 mm 4 150 mm 6 75 mm 3 100 mm 4 150 mm 6 Bold sizes are standard and other sizes are available on request

5 FLEXIBLE DUCT CONNECTOR TYPE «LOC3» 24 ga. (0,6 mm) steel thickness (Amercican standard) A = thickness of steel : 24 ga. (0,6 mm) B = steel width C = fabric width L= length of roll : 100 feet (30,5 m) B C B Others lengths on request B = STEEL WIDTH C = FABRIC WIDTH LOC3 3 75 mm 2 50 mm 4 100 mm 6 150 mm 3 75 mm 3 75 mm 4 100 mm 6 150 mm 4 100 mm 4 100 mm 6 150 mm Bold sizes are standard and other sizes are available on request

6 RECOMMENDED ASSEMBLY METHOD At a notch, cut a length equivalent to the perimeter required plus an overlap of 5 to 6 cm (2 ). Lift the seam outwards at right angle. Make a cut at the edge of the seam section. Bend down the seam while ensuring that the cloth remains fastened. Coat the cloth with the appropriate adhesive, or pad. Join both sides and press together. Information contained herein is based on careful tests and experience. It reflects our knowledge and is for guidance purpose only. It is given in good faith and user should ensure that the product is fit for purpose before any application. The quoted values are average and should not be taken as maximum or minimum values for specific purposes. Manufacturer and distributor are not responsible for any non-recommended use or consequential damage.

Belgium