WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORRUGATED STEEL TAPE CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be PRINTING DETAILS < 0.05dB/Km ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.1 Date:- 09-09-2011
Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 24 12 2 4 BL,OR. 12.2 135 BL,OR,GR,BR, 48 12 4 2 BL,OR,GR,BR. SL,WH,RD,BK, 12.2 135 YL,VI,PK,AQ. 72 12 6 0 BL,OR,GR,BR,SL,WH. 12.2 135 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 / 6 Km + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 09-09-2011
Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER CORRUGATED STEEL TAPE WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL ENVIRONMENTAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011
Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 96 12 8 0 144 12 12 0 RD,BK. RD,BK,YL,VI,PK,AQ. RD,BK,YL,VI,PK,AQ. 13.9 170 17.3 240 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011
Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK MDPE SHEATH CORE WRAPPING WITH GR YARNS (If required) CORRUGATED STEEL TAPE WS MATERIAL FRP CENTRAL STRENGTH MEMBER WATER SWELLABLE YARNS LOOSE TUBE WITH FIBERs AND WSY RIPCORD(S) OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mminstallation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- 24/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011 Registered Office:E, MIDC Waluj, Aurangabad-431136, Maharashtra, INDIA.
Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 288 12 24 0 RD,BK,YL - for 1st Layer RD,BK,YL,VI,PK,AQ BL,OR,GR - for 2nd Layer BL,OR,GR,BR,SL,WH, RD,BK,YL,VI,PK,AQ. 19.7 280 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/XX-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011 Registered Office:E, MIDC Waluj, Aurangabad-431136, Maharashtra, INDIA.