OPTICAL FIBRE CABLE PERFORMANCE

Similar documents
Specifications of. Single Armored Optical Fiber Cable

Fibre optic cables CTC LSZH 1,2kN

FTTH Fiber Optical Cable

Detailed Specifications & Technical Data

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials.

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

Amphenol Spectra-Strip

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

PERFORMANCE SPECIFICATION SHEET

Generic Requirements for Optical Fiber and Optical Fiber Cable

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

etwork etwork-/ethernet-/foc-cable

BHUTAN TELECOM LIMITED

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

RN Optical Termination Panel (RN OTP)

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

Industrial Harsh Environment Fiber Cables

PLASTICS. Chapter 5. Materials of Construction-Plastics 1

The Company by Peter Bröckskes sen. an independent, middle sized company

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Specialty Multimode Graded-Index Fiber

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Safe, efficient cable protection with high performance polymers

Cables for Railway Signalling Applications General Requirements

Expanded Beam Optical Termini

Heat-Resistant Thin Optical Fiber for Sensing in High-Temperature Environments

Glossary Of Terms M-1

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition

Construction guideline

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Corning RC Specialty Fibers Reduced Cladding Fibers Enable Miniaturization and Device Integration

Best Construction Practices and Splicing for Fiber Networks

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Product Specifications

Fujikura PANDA fiber products and Basics of PM fibers

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Electrical Insulating Tapes

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

Ultradur (PBT) Product Range. Ultradur in the web:

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

INTERNATIONAL STANDARD

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

SURFACE TEMPERATURE SENSORS

OPTICAL FIBER SOLUTIONS


Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

TORAY RAYTELA Structure Product

Experience and a History in Construction Products

High Performance Plastics for Wind Turbine Engineering

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

Lahti Precision Fluidization

FIBER OPTIC PROJECT IMPLEMENTATION

NPS/002/023 Technical Specification for 132kV Power Cables.

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

Engineering Data for Copper and Aluminum Conductor Electrical Cables

1 The Eldon James Flexelene TM tubing combines the excellent inert qualities of polyethylene with the flexibility found in 78A durometer PVC tubing. F

High Performance Plastics for the Chemical Processing Industry

SECTION HORIZONTAL CABLING

catalog Copper Wires

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

ASME B31.3 Process Piping

International Thermocouple and Extension Grade Wire Color Codes

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

Polyethylene (HDPE) Thin Wall Containers

INTERNATIONAL STANDARD

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY

WEIR PLATES & SCUM BAFFLES

Series K7130 Heavy Wall PVC Transfer Hose. Compound hardness 73 ±3 Shore A. Self-extinguishing. Non-marking, non-toxic and silicone-free.

High Durability Cables Cordsets for use in extreme conditions in manufacturing

FIBERGLASS HANDRAIL & LADDER SYSTEMS

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

ERTALON Extruded Products

Military Specifications

Military Specifications

U.V resistance UL Sunlight Resistance. Flame retardant IEC

SPR-54 Series. Data Sheet. Outline. Features. Viewing angle 2θ 1/2 : 45. Recommended Solder Pattern. Dimensions. Specifications. 1/ Rev.

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual

Super Low-Loss, Super High-Density Multi-Fiber Optical Connectors

Single-Jacketed Tubing

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

SECTION WIRES AND CABLES

Transcription:

WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORRUGATED STEEL TAPE CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be PRINTING DETAILS < 0.05dB/Km ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.1 Date:- 09-09-2011

Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 24 12 2 4 BL,OR. 12.2 135 BL,OR,GR,BR, 48 12 4 2 BL,OR,GR,BR. SL,WH,RD,BK, 12.2 135 YL,VI,PK,AQ. 72 12 6 0 BL,OR,GR,BR,SL,WH. 12.2 135 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 / 6 Km + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 09-09-2011

Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER CORRUGATED STEEL TAPE WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL ENVIRONMENTAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011

Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 96 12 8 0 144 12 12 0 RD,BK. RD,BK,YL,VI,PK,AQ. RD,BK,YL,VI,PK,AQ. 13.9 170 17.3 240 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011

Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK MDPE SHEATH CORE WRAPPING WITH GR YARNS (If required) CORRUGATED STEEL TAPE WS MATERIAL FRP CENTRAL STRENGTH MEMBER WATER SWELLABLE YARNS LOOSE TUBE WITH FIBERs AND WSY RIPCORD(S) OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mminstallation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- 24/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011 Registered Office:E, MIDC Waluj, Aurangabad-431136, Maharashtra, INDIA.

Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km 288 12 24 0 RD,BK,YL - for 1st Layer RD,BK,YL,VI,PK,AQ BL,OR,GR - for 2nd Layer BL,OR,GR,BR,SL,WH, RD,BK,YL,VI,PK,AQ. 19.7 280 Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/XX-F-D-S3-1-BM-TD Rev.:-1.0 Date:- 13-07-2011 Registered Office:E, MIDC Waluj, Aurangabad-431136, Maharashtra, INDIA.