Section 12 - Guidelines for Milk Analysis. Version October, 2017

Similar documents
CombiFoss TM 7. Herd-improvement and payment testing in one integrated unit

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

SOMATIC CELL COUNTER FOR RAW MILK

SUBSCRIPTION MODEL 2009

Highly Accurate, Reliable and Real-time Enumeration of Individual Bacteria for the Determination of Raw milk Hygienic Quality

RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT

Milk quality testing and regulation

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

Guidance for Swedac s assessors on the assessment of laboratories based on the requirements set out in SS-EN ISO/IEC 17025:2005

A016 Traceability of measurement results compared to national and international measurement standards

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

- CONTAMINANTS IN FOOD (COUNCIL REGULATION (EEC) No 315/93 OF 8 FEBRUARY 1993 LAYING DOWN COMMUNITY PROCEDURES FOR CONTAMINANTS IN FOOD 1 )

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES

Preparation Approval Authorisation Application date. Directive Council The President

Proficiency Testing Program User Guide

Exposing Myths, Legends and Tales About Reference Materials. Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK

The future of food testing which way to go?

Rules for accreditation of providers of proficiency testing/interlaboratory

ILAC P10 TRACEABILITY

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS

ILAC-P10:2002. ILAC Policy on Traceability of Measurement Results

Report No Waters Proficiency Testing Program. Round No Total Solids, Total Suspended Solids, Total Dissolved Solids - March 2017

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

Sampler with PM 2.5 pre-separator

The new ISO/IEC 17025:2017

PAB PRINCIPLE. Kit Reorder # ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Pesticides: Method Validation and Quality Control

AAG PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

GLP/SC/01 Basic statistical tools for analytical chemistry (2 days)

Handbook ISO/IEC 17025:2017

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

Revisione della norma ISO 4259 Andrea Gallonzelli

Revision of 30 April 2013 draft, 4 November 2013

Meeting the ISO/IEC Requirements for Traceability and Measurement Uncertainty. APLAC Approaches. Dr Bernard King NARL, Australia

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 1] GENERAL REQUIREMENTS FOR STATIONARY SOURCE AUDIT SAMPLE PROVIDERS

Event-specific Method for the Quantification of Soybean CV127 Using Real-time PCR. Validation Report

ISO General Requirements for Competence of Testing Laboratories Procedure

News from the European Reference Laboratory for Milk and Milk Products (EU-RL MMP), Paris, 2011

PRINCIPLES FOR THE USE OF SAMPLING AND TESTING IN INTERNATIONAL FOOD TRADE CAC/GL Adopted in Revision: 2015.

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009

Ainvolved in many aspects of project planning, sample collection,

The role of accreditation bodies and EQA organisers in the. specifications

WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products

TECHNICAL DIRECTIVE PART ONE: STANDARDIZATION AND RELATED ACTIVITIES GENERAL VOCABULARY

ILAC-P10:01/2013 -Calibration-

WELMEC European cooperation in legal metrology

The new International Standard ISO 17034: general requirements for the competence of reference material producers

What is the purpose of this website?

SIERRA LEONE STANDARDS BUREAU

MRR Guidance on Risk assessment and control activities Examples

The Role of Proficiency Testing in Laboratory Capacity Building in Chile

NiMS. Scheme Description. Nickel Migration Proficiency Testing Scheme

OPAC EN Operating Procedure for the Attestation of Conformity of Structural Bearings in compliance with Annex ZA of EN 1337/3/4/5/6/7

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Quality Assurance of Investigational Medicinal Products. Sue McKenzie PPQA (A)

SEMIS COURSE ON SEED QUALITY ASSURANCE, MANAGEMENT AND CONTROL PROCESSES. PRESENTED BY Munyao W. M.

EAM 3 / GUI 4 MAPPING BETWEEN ISO 9001:2000 AND ESARR 3

FQS Accreditation for forensic testing agencies NEMC ANSI-ASQ National Accreditation Board

Guidelines. on imports of organic products into the European Union

Air Monitoring Directive Chapter 5: Quality System

FINAL REPORT

Hong Kong Deposit Protection Board

Procedure for Approval of Novel Technologies, Alternative Premises and Equipment Designs

Quantos Solutions. Gravimetric Sample Preparation (GSP) Automated Weighing

The EA Laboratory Committee point of view of IQC activities. Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD, Greece

Inspection Qualification and Implementation of ENIQ in Sweden

Quality Assurance in Dairy through digitation and IoT

Measurement Assurance and Certification Scotland

IQC In Microbiology Testing

Protocol Page 1 of 11. Protocol for Proficiency testing scheme for Bitumen Programme No. GPTS/PT 05

Performance Standards for Continuous Ambient Air Quality Monitoring Systems. Environment Agency Version 8 June 2012

Title Requirements for the accreditation of calibration laboratories

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

Latest innovations for the monitoring of milk hygienic quality, methods automation and standardization

Guidelines for Process Validation of Pharmaceutical Dosage Forms

Barrack Road, The Nothe, Weymouth DT4 8UB E: T: +44 (0) F: +44 (0)

Roundtable Discussion Method Validation & Verification

ISTA Accreditation Standard for Seed Testing and Seed Sampling

CORESTA RECOMMENDED METHOD N 61

PROACTIVE APPROACHES. for QUALITY MANAGEMENT. Anabela Martins Micoteca da Universidade do Minho

ISO/IEC 17025:2017 Working Document Instruction Page

IECEE OPERATIONAL DOCUMENT

The APIC Audit Programme Version 5, July 2017

INTERPRETATION AND GUIDANCE ON THE ESTIMATION OF UNCERTAINTY OF MEASUREMENT IN TESTING

Proficiency Testing. Protocol. Organisation and Analysis of Data

Guidance Document. Guidance for Risk Management Programme (RMP) Template for Dairy Processors. Liquid Milk, Domestic Supply.

Harmonization day 2015 FSSC audit reporting

The Infratec. Network Concept

Addendum No. 1 to the CSTBat Certification Reference System: Connection hoses

TUV SUD BABT PRODUCTION QUALITY CERTIFICATION SCHEME

Accreditation of Reference Material Producers

EURL-FA Guide: Protocol for verification studies of singlelaboratory/in-house

Certification program "Quality Mark TMT" Checklist initial surveillance inspection

OIE Procedure for Validation and Certification of Diagnostic Assays

ISO/IEC 17025:2017 Transition Webinar Questions & Answers

Industry Perspective on Manufacturing in Early Development

ETV Test Centre and Test Organization

HACCPEUROPA PUBLICATIONS ISO 22000:2005 FOOD SAFETY QUALITY MANUAL. ISO 22000:2005 Quality Manual

Transcription:

Section 12 - Guidelines for Milk Analysis Section 12 Milk Analysis

Table of Contents Overview 1 Field of application... 4 2 Reference methods... 4 3 Routine (instrumental) methods... 4 4 Specific recommendations for DHI milk samples... 4 4.1 Bottles... 4 4.2 Preservatives... 5 5 Quality control for DHI laboratories... 5 5.1 Quality control on reference methods... 5 5.1.1 External control... 5 5.1.2 Internal control... 6 5.2 Quality control on routine methods... 6 5.2.1 External control... 6 5.2.2 Internal control... 7 6 Requirements for analytical quality control and quality assurance tools... 7 6.1 Interlaboratory proficiency studies... 7 6.2 Reference materials... 8 6.3 Choice of AQA service suppliers... 8 7 Appendix 1. Analytical quality control in milk testing laboratories... 9 7.1 Components and frequencies... 9 7.2 Frequencies and limits for routine methods... 9 7.3 Checking... 10 8 Appendix 2. Methods... 12 8.1 International reference methods... 12 8.2 Other methods (secondary reference)... 13 8.3 Standardized routine methods... 13 8.4 Instrumental routine methods used in ICAR countries... 14 Tables Table 1. Components of a quality control and recommended frequencies.... 9 Table 2. Frequencies and limits for checking routine methods.... 10 Table 3. International reference methods.... 12 Table 4. Other methods (secondary reference).... 13 Table 5. Standardized routine methods.... 13 Table 6. Instrumental routine methods used in ICAR countries.... 14 Milk Analysis - Page 2 of 14.

Change Summary Overview Date of Change Nature of Change August 17 August 17 August 17 August 17 August 17 August 17 August 17 Reformated using new template. Table of contents added. Heading numbers and heading text edited for clarity and removal of redundant text. Captions added to all tables. Tables added to table of contents. Cross references updated and automated. Stopped Track change sand accepted all previous changes. Moved the file to the new template (v2017_08_29). Sept. 17 Corrections to tables 1 and 2 in Section 7, from Gavin Scott (12 TH Sept, 17). Oct. 2017 Hyperlinks have been corrected as well as the date of the version Milk Analysis - Page 3 of 14.

1 Field of application These guidelines concern methods for fat, protein, lactose, urea and somatic cells determinations in individual cow, goats and ewes milk. Milk samples are in most cases preserved with chemical substances. This will be taken into account in the procedures. They define: a. Authorised reference methods. b. Approved routine instrumental methods. c. Recommendations for sample quality. d. Recommendations for quality control of analyses. 2 Reference methods The wording "reference methods" designates the methods used to calibrate the instrumental (routine) methods. The reference methods should be internationally standardised methods (i.e. ISO, IDF, AOAC methods); although practical arrangements are permitted (see note below). The reference methods are listed in section 8 below. Note: Reference transfers a. Rapid chemical methods can be used instead of a more time consuming reference method as far as results have shown to be equivalent to those from reference methods (i.e. Gerber method for fat, Amido Black method for protein). b. Master instruments (indirect rapid methods) may be used to produce "reference values" for other instruments and for other laboratories in case of a system with centralised calibration. Instrumental values may be considered equivalent to the values of the method used as reference for the calibration. Application of a centralised calibration concept must take into account sensitivity of routine methods to matrix effects (milk composition). 3 Routine (instrumental) methods Routine methods should be either standardised methods, or methods which have received an official approval from the national DHI organisation on the basis of a performance evaluation by an expert laboratory and using a standardised protocol, or methods approved at the international level by ICAR. With this respect, conditions and procedure of evaluation, as well as requirements for ICAR approval, are defined in a standard protocol approved by ICAR as relevant for the purpose of milk recording. 4 Specific recommendations for DHI milk samples The sample quality is the first major requirement for a consistent analytical result. Good quality samples are a prerequisite to establish whether analytical quality requirements are met. 4.1 Bottles In general terms, vials and stoppers must be suitable for their purpose (to bring milk without loss or damage to laboratories). For instance, a too large empty volume above the milk may Milk Analysis - Page 4 of 14.

facilitate churning during transport, especially with non-refrigerated milk. A too small empty volume above the milk may give rise to problems with mixing. Fat loss may occur with imperfectly tight stoppers. 4.2 Preservatives Preservation of milk recording samples using chemical compounds should: Notes a. Maintain the physical and chemical properties of the milk during the period running from sampling to analysis in the usual temperature and transport conditions. b. Not prevent from performing reference analysis, as the possibility of control remains to the laboratories. c. Have no effect on the results of analysis with the reference methods and no or only a limited effect on the routine instrument response (a limited effect can be compensated for through calibration). d. Be innocuous to DHI and laboratory staff according to local health regulations. e. Be innocuous to environment according to local environmental regulations. a. Sample preservation is promoted working with clean milking and sampling equipment, by storage of samples at cool temperatures during limited time with a minimum of handling. b. Appropriate preservatives are mentioned in relevant standards with guidance (ISO 9622 IDF 141 and ISO 13366 IDF 148). Nevertheless, in general care must be taken for: - preservative excipient: depending on the excipient - generally salts - various effects can be observed for applied formulations where none exists in the pure form (case of potassium dichromate and bronopol in milk by mid infra red spectrometry); - some dyes which are used as colour tracer may interfere with the instrumental response (absorption of light or dye-binding with DNA). The accuracy of the sensitivity of a method may therefore be reduced. These dyes should be avoided. 5 Quality control for DHI laboratories 5.1 Quality control on reference methods Any systematic error on reference method leads to an overall systematic error on routine results. This type of error which may exist between laboratories within a country (or organisation) and between countries, co-operating within international frameworks such as ICAR, justifies performance evaluations at both levels, national and international. 5.1.1 External control Every DHI routine laboratory should be involved in an interlaboratory proficiency study (IPS) scheme. Proficiency testing should be organised preferably by a national reference or pivot laboratory appointed for that by the national DHI organisation. The reference laboratory will provide analytical precision traceability by its regular participation in international proficiency trials. Milk Analysis - Page 5 of 14.

Note: Overview In situations where there are not sufficient laboratories to implement a national scheme, the laboratory can join PT schemes organised by a national or an international PT provider or the national DHI PT scheme of a neighbouring country. As far as possible, it should be aimed at establishing and maintaining a link for traceability with the international level. The minimum frequency for participation in interlaboratory proficiency studies should be 4 times a year. National reference laboratories should take part in international proficiency studies at a minimum frequency of once a year. Nevertheless, a more frequent participation is advised. In the particular case of centralised calibration and control system, where only the reference laboratory performs reference methods, participation of routine laboratories in proficiency testing for reference is no longer necessary. These trials are to be organised according to international standards, or failing that, international guidelines or agreements as indicated in this section. 5.1.2 Internal control Reference materials (RMs) are advised for use to check the exactness and the stability of reference methods used between two consecutive proficiency testing by comparison with nominal values. They will be used preferably when reference for calibration of routine methods are carried out (i.e. weekly). They can be: a. Certified reference materials (CRMs) produced by a recognised official organisation. b. Secondary reference materials (SRMs) prepared by an external supplier. c. In-house reference materials (IRMs) prepared by the laboratory itself,where traceability is established with CRMs, SRMs or interlaboratory proficiency studies. Whatever the choice made by the laboratory, CRMs and SRMs are to be produced and provided in QA conditions and according to international standards, or failing that, international guidelines or agreements as indicated in section 5.1.1 above. IRMs constitute the simplest case of a single producer/user for own purposes. Therefore one is only concerned by production and quality control requirements. The laboratory then requires to meet with the demands from its own QA system, thereby referring to relevant parts of available guides. 5.2 Quality control on routine methods Routine methods provide the results effectively used for DHI purposes and, therefore, their consistency has to be checked. For this, reference is made to the standard ISO 8196 IDF 128 (Part II). 5.2.1 External control A periodical control of the accuracy must be applied by an national expert laboratory, either through individual external control (IEC), by comparison of routine methods to reference analysis on samples representative of the laboratory area, or through interlaboratory proficiency studies when it has been clearly demonstrated that a single calibration can be Milk Analysis - Page 6 of 14.

used for all the laboratories. In the latter case, recommendations of Section 5.1.1 above are to be followed. The minimum frequency recommended is 4 times a year. Repeatability and suitability of calibration are the main parameters to be checked. Depending on the experimental design, additional aspects can be evaluated such as sample preservation and instrumental parameters such as linearity and intercorrections. 5.2.2 Internal control Irrespectively of the parameter, an internal quality control on routine methods has to be carried out in routine testing at the laboratory. In general the standard ISO 8196 IDF 128 does not define limits to fulfil for each method and/or milk component. Therefore specific standards have to be applied where they exist: a. Fat, protein and lactose (mid infra-red spectrometry): ISO 9622 IDF 141. b. Somatic cell count: ISO 13366 IDF 148; c. Urea (mid infra-red spectrometry): next update of ISO 9622 IDF 141. Preparation of pilot samples, used for monitoring instrument stability, should be made under quality assurance (i.e. quality control for homogeneity and preservation), thereby referring to relevant indications of international standards/guides for reference materials. According to ISO 8196 IDF 128, the major stages of control can be summarised as follows: a. Repeatability. b. Daily and short-term stability of instrument. c. Calibration. In addition, checkings related to instrumental aspects are recommended in specific standards: a. Carry-over effect (all methods). b. Linearity (all methods). c. Zero-setting (all methods). d. Intercorrections (infra-red). e. Homogenisation (infra-red). It is advised to fulfil requirements about frequencies and limits as in Section 7 below. 6 Requirements for analytical quality control and quality assurance tools 6.1 Interlaboratory proficiency studies Interlaboratory proficiency trials are to be organised in quality assurance conditions, according to international standards, or failing that, international guidelines or agreements. At the editing date of the present documents, one can refer to: a. ISO Guide 43. b. ILAC-G13. c. International Harmonized Protocol for Proficiency Testing of (Chemical) Analytical Laboratories (IDF Bulletin 342:1999). Milk Analysis - Page 7 of 14.

d. ISO Standard 13528. 6.2 Reference materials Reference materials used for DHI analytical purposes are to be produced in quality assurance conditions, according to international standards, or failing that, international guidelines or agreements. At the editing date of the documents, one can refer to: a. ISO Guide 34. b. ILAC-G9. c. ILAC-G12. 6.3 Choice of AQA service suppliers Choice of Analytical Quality Assurance (AQA) service suppliers - i.e. proficiency testing and reference material - by DHI laboratories is to be made in tight relation to the existence of a quality assurance system for the services production and supply as part of the overall DHI AQA system. Services suppliers should operate under quality assurance and be able to provide documented proof of that. Service suppliers should submit themselves to a periodical independent audit, i.e. a third party, in order to have the conformity of its QA system judged. These audits can be carried out by accreditation assessors, commissions of user representatives, experts (employed by or consultant) acting in the name of the DHI national organisation, provided that their competence and independence are guaranteed and that the audits are conducted in line with ISO and ILAC recommendations. Note These requirements are covered by accreditation. The latter is highly recommended in particular for specialised (inter)professional or commercial organisations dealing with large AQA lab service activities. In every case, notably for those countries where such an accreditation is not (yet) possible or for small and emerging organisations, the implementation of an in-house QA system remains the minimum base required. Milk Analysis - Page 8 of 14.

7 Appendix 1. Analytical quality control in milk testing laboratories It is to be expected that meeting these requirements will provide a satisfactory minimum quality level for analytical measurements, as well as comparability between laboratories and countries. If the following scheme cannot be immediately applied, it should be considered as a target. 7.1 Components and frequencies Table 1. Components of a quality control and recommended frequencies. Control Frequencies Mode Reference methods - External control Quarterly IPS - Internal control Weekly (for each check of CRMs, SRMs, IRMs the mean bias) Routine methods - External control Quarterly IPS/IEC - Internal control (see 7.2) IRMs IPS: Interlaboratory Proficiency Study. CRMs: Certified Reference Materials. IEC: Individual External Control. SRMs: Secondary Reference Materials. IRMs: In-house Reference Materials. 7.2 Frequencies and limits for routine methods Frequencies and limits stated hereafter in Table 2 are for a part defined in existing ISO IDF standards or are derived from contained recommendations. Other values are tentative, therefore indicative and provisional, as they are not yet defined in a standard. Experience will show whether or not the latter ones are suitable for all laboratories. Limits stated below in Table 2 are proposed as "action limits" for internal instrument management. They should only be considered as technical information to users and not be used for external evaluations for which other (larger) values can appear more suitable. Milk Analysis - Page 9 of 14.

Table 2. Frequencies and limits for checking routine methods. Overview Checks Frequencies F P L Limits SCC Instrumental fittings Homogenization Monthly 0.05 % units or (a) None 1.43 % relative Carry-over Monthly 1 % (a) ( 2 %) (c) Linearity (curving) Quarterly 1 % of range (a) ( 2 % of (c) range) Intercorrection Quarterly ±0.02 (a) none Calibration Mean bias Weekly ±0.02 % units (b) ±5 % relative (b) Slope Quarterly 1.00±0.02 (b) 1.00±0.05 (b) (1.00±0.03)* (c) (1.00±0.07)* (c) (1.00±0.05)** (c) Overall daily stability Repeatability (sr) Daily/every 0.014 % units (a) 5 % relative (a) Start-up 0.020 % units* (a) Daily/short-term 3/hour ±0.05 % units (a) ±10 % relative (b) stability Zero-setting 4/day (±0.03 % units) (c) ( 5000 /ml) (c) (a): Limit stated in ISO 9622 IDF 141 or ISO 13366 IDF 148 (b): Limit stemming from specifications of ISO 9622 IDF 141 or ISO 13366 IDF 148 (c): Tentative (indicative) limit as there is no value specified in corresponding international standards *: Limit for first generation instruments **: Limit for lactose Note 1: In case calculated values are out of limits but do not differ from a statistical point of view, adjustments in instrumental settings are not justified. Therefore, representative and/or adequate sample sets should be chosen or prepared in such a way that any outside value should be significant. Relevant aspects in this are type and number of samples, number of replicates and level of concentration. Note 2: 7.3 Checking a. Milk with high fat and protein concentrations (milk of buffaloes, ewes, and particular cow and goat species). Because of variable high fat and protein contents, reliable limits for repeatability and short-term stability can be determined by multiplying limits for cows by the ratio of buffaloes (or ewes) average level versus cows average level. b. Goats milk: Limits can be the same as for cows milk in case of similar fat and protein content. In case of high fat and protein contents, one will operate according to a). a. Check on homogenisation: In infra-red analysis, the natural size of fat globules strongly affects the measurement of fat, therefore a fat size reduction is applied through an homogenisation before the measurement. Inefficient homogenisation results in poor repeatability and drifts of the signal. b. Check on carry-over: Successive samples with strong different of component levels may be affected by the former milk either by the residual volume of milk in the flow Milk Analysis - Page 10 of 14.

system or by the contamination by the stirrer and the input pipe. As an effect of a constant dilution, the error is a proportion of the difference of concentration with the previous sample. The overall carry-over effect should be minimised and, in all cases, should not exceed limits stated. c. Check on linearity: Specific sets of samples are prepared in order to cover the whole range of concentration and check that the instrumental measurement is proportional to the concentration of the component measured. The percentage of the bending can be estimated by the ratio (range of the residuals observed) x 100 /(range of the levels). d. Check on intercorrections: Specific sets of samples are prepared in order to create independent modification in respective components and verify that changes in one particular component do not affect significantly the measurement of the other components. Intercorrections are set in order to compensate the natural interactions due to a incomplete specificity of methods. The larger the range of concentrations of the correcting channel, the bigger the potential error due to an inadequate intercorrection adjustment for the corrected channel. e. Check on the mean bias: Representative milk samples are used to check the validity of the calibration at a medium level and prevent any drift which could occur from changes in milk composition or progressive wear of instruments. Checking that the zero and the mean bias fit the stated limits provides assurance for the maintenance of the calibration on the whole range. f. Check on the slope: Specific sets of samples are prepared in order to cover the whole range of levels and check that the slope is within the stated limits. It is aimed at that differences between instrumental values and reference values should not be proportional to the level but constant on the whole range. The larger the range of concentrations, the bigger the error for extreme values in case of an inadequate slope adjustment. g. Repeatability: Repeatability check is the simplest test indicating whether or not the instrument is working properly. Repeatability is evaluated at the start-up of each instrument on the basis of 10 times replicate analysis of one (control) milk sample. During routine testing a regular test can be made by analysing a set of 20 different individual samples in two successive runs. The estimate of the standard deviation of repeatability should meet stated limits. h. Daily and short-term stability: Every day and regularly along a working day, the so-called control samples (or pilot samples) are used to check instruments fitting at a medium level. Differences observed against assigned values should not exceed the stated limits +/-L. It is advised to complete the control using the calculation of the cumulative mean of the n successive differences which should not exceed the limits +/-L/ n. i. Zero-setting: Rinsing the flow system and checking the "zero value" are periodically required to prevent milk matter deposit on the walls of the measurement cells and/or (depending on instruments) to detect any drift of the basic signal. Milk Analysis - Page 11 of 14.

8 Appendix 2. Methods 8.1 International reference methods Table 3. International reference methods. Fat Gravimetric method (Röse-Gottlieb) ISO 1211 IDF 1 AOAC 905.02 (IDF-ISO-AOAC-Codex) Gravimetric method (modified Mojonnier) AOAC 989.05 (IDF-ISO-AOAC) Protein Titrimetric method (Kjeldahl) ISO 8968 IDF 20 AOAC 991:20 (IDF-ISO-AOAC) AOAC 991:21 AOAC 991:22 (IDF-ISO-AOAC) AOAC 991:23 (IDF-ISO-AOAC-Codex) Casein Titrimetric method (Kjeldahl) ISO 17997 IDF 29 AOAC 927.03 AOAC 998.05 AOAC 998.06 AOAC 998.07 Lactose HPLC method is foreseen to provide the reference to routine methods by ISO IDF and its international standardisation is underway (ISO DIS 22662 IDF 198). In the meantime, standardised methods as referred to in Part II, other methods can be used. Urea Differential ph-method (Reference method) Somatic cell count Microscope method (Reference method) ISO 14637 IDF 195 ISO 13366-1 IDF 148-1 Milk Analysis - Page 12 of 14.

8.2 Other methods (secondary reference) Table 4. Other methods (secondary reference). Fat Butyrometric method (Gerber) ISO 2446 AOAC 2000.18 Babcock AOAC 989.04 Protein Dye-binding (Amido Black) ISO 5542 IDF 98 AOAC 975.17 (IDF-ISO-AOAC) Dye-binding (Orange 12) AOAC 967.12 Dumas method ISO 14891 Lactose Enzymatic ISO 5765 IDF 79 AOAC 984.15 Gravimetric AOAC 930.28 Polarimetric AOAC 896.01 Under standardisation High Performance Liquid Chromatography ISO DIS 22662 IDF 198 Differential ph-method ISO WD IDF (working draft) 8.3 Standardized routine methods Table 5. Standardized routine methods. Fat Automated turbidimetric I AOAC 969.16 Automated turbidimetric II AOAC 973.22 Protein Automated dye-binding (Amido Black) Fat-protein-lactose Mid infra red (MIR) spectrometric ISO 9622 IDF 141 AOAC 972.16 Urea (taken into account with the underway revision of ISO 9622 IDF 141) Somatic cell count Electronic particle counter (Coulter Counter) AOAC 975.17 (FIL-ISO-AOAC) International standards withdrawn Fluoro-opto-electronic methods ISO 13366-2 IDF 148-2 AOAC 978.26 Milk Analysis - Page 13 of 14.

8.4 Instrumental routine methods used in ICAR countries Overview The following list was drawn up with answers to ICAR questionnaires of 1994 and 1996, since then supplemented with new validated analysers. Methods/instruments not produced or used any longer are indicated in Italic characters. Table 6. Instrumental routine methods used in ICAR countries. Fat Turbidimetric method MilkoTester (Foss Electric, DK) Fat and protein Turbidimetric/dye-binding: MTA-PMA (Foss Electric, DK) Fat, protein (and lactose) Mid infra-red spectrometry Milkoscan (Foss Electric,DK) 102, 103, 104, 104 (A/B) 133 A, 133 B, 134 (A/B) 203 A, 203 B, 300 255 (A or B), 605 (A or B) Series 4000 (A or B) FT 120 (FTIR) FT 6000 (FTIR) Multispec (Multispec,UK) MK 1 MK 2 Micro-null Bentley (Bentley, USA) 150 2000 (A or B) Lactoscope (Delta Instruments, NL) Aegys (Anadis Instruments, F) 300, 550, 750, Filter Automatic 200, Filter Automatic 400, FTIR Auto 400 MI 600 (FTIR) Milk Analysis - Page 14 of 14.