SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

Similar documents
SECTION GLASS BALUSTRADE RAILING SYSTEMS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION ALUMINUM HANDRAILS AND RAILINGS

PIPE AND TUBE RAILINGS

SECTION ALUMINUM RAILINGS

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Aluminum Component Pipe Railings

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Section PANEL SIGNAGE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PIPE AND TUBE RAILINGS

A. Access doors and frames are part of an access door and frame allowance.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SPECIFICATIONS: Architectural Aluminum Railings

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

SECTION METAL FLOOR PLATE STAIRS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ALUMINUM STORM WINDOWS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION HVAC GRAVITY VENTILATORS

SECTION PRE-ENGINEERED ALUMINUM STAIRS AND RAILINGS

SECTION DIRECTORIES

SECTION ORNAMENTAL HANDRAILS AND RAILINGS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION PIPE AND TUBE RAILINGS

SECTION EXPANSION CONTROL

Specifications for FL-100 Soffit Panel

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

American Metal Specialties, Inc.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION ALUMINUM WINDOWS

ALL-ALUMINUM DOOR & WINDOW FRAMING

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

MC BEAMLINE ENCLOSURE

2049 S.W. Poma Drive Palm City, Fl Office (772) CGC Fax (772)

SECTION TURBINE VENTILATORS

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

Division 11 - Equipment Section 11401

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

Daytona Beach Pier Building Renovation Jun 2010

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

Attachment A-Flagpole(s) Specifications

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

Multi-Institutional Academic Health Science & Research Center Evansville, IN

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION DECORATIVE METAL FENCES AND GATES

SECTION EXTERIOR GRILLS AND SCREENS

SECTION CHAIN LINK FENCES AND GATES

SECTION ROOF SPECIALTIES

Ultra Aluminum Fence, Rail & Gate Specifications

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Note: Any verbiage written in red needs to be specified. All other options should be deleted

University Apartments on Brooklyn PROJECT MANUAL

by Rollfab Metal Products

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS


A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

EDGEWATER, FLORIDA JUNE 14, 2010

EXAMPLE SPECIFICATION ONLY

SECTION FLOOR MATS AND FRAMES

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

Aluminum-Framed Entrances and Storefronts

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

A. This Section includes the following: B. Related Sections: The following Sections contain requirements that relate to this Section:

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

Architectural Specifications, Section Phenolic Lockers

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Guideline Specifications

Corium Brick Rainscreen System Specifications

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

Privacy Plus Partitions

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

SPECIFICATION SECTION PART 1 GENERAL

Transcription:

Page 1 of 17 SECTION 11 4600 FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Sneeze Guards, Food Shields, Partition, and Barrier Posts. B. Related Sections include the following: 1. Division 5 Section Pipe, Tube and Malleable Iron Railings For sneeze guards and partitions fabricated from metal pipe and tube components. 2. Division 6 Section Finish Carpentry 3. Division 8 Section Glazing 1.3 PERFORMANCE REQUIREMENTS A. General: In designing a Sneeze Guard or Partition Post System check the regulations for Sneeze Guards as set by national standards and/or by the local Health Department or Building Department. 1.4 SUBMITTALS A. Product Data: For manufacturers product lines of sneeze guards and partitions assembled from standard components. 1. Include Product Data for anchoring, metal cements, and silicone sealants. B. Shop Drawings: Show fabrication and installation of sneeze guards and partitions. Include plans, elevations, sections, details, and attachments to other work. C. Samples for Initial Selection: Manufacturer s charts showing the full range of factory-applied finishes available for products. D. Samples for Initial selection: Short sections of tubing or flat sheet metal samples showing available finishes. E. Assembled Samples of sneeze guards and partitions, made from full-size components, including post, top cap, base, and infill. Samples need not be full height. F. Qualification Data: For firms and persons specified in Quality Assurance Article to demonstrate their capabilities and experience. Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified.

Page 2 of 17 1.5 QUALITY ASSURANCE A. Source Limitations: Obtain each type of sneeze guard and partition through one source from a single manufacturer. 1.6 STORAGE A. Store sneeze guards and partitions in a dry, well-ventilated, weather tight place. 1.7 PROJECT CONDITIONS A. Field Measurements: Verify sneeze guard and partition dimensions by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the work. 1. Established Dimensions: Where field measurements cannot be made without delaying the work, establish dimensions and proceed with fabricating sneeze guards and partition without field measurements. Coordinate construction to ensure that actual dimensions correspond to established dimensions. 1.8 COORDINATION A. Coordinate installation of anchorage for sneeze guards and partitions. Furnish Setting Drawings, templates, and directions for installing anchorages, including flanges, canopies, anchor bolts, and concealed base lugs. Deliver such items to project site in time for installation. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include the following: 1. Sneeze Guards and Partitions: a. C.R. Laurence Co., Inc. 2503 E. Vernon Ave. Los Angeles, CA. 90058 Toll Free: (800) 421-6144 Toll Free Fax: (800) 262-3299 International Phone: (323) 588-1281 International Fax: (323) 584-5289 www.crlaurence.com email: hospitality@crlaurence.com SEE FOLLOWING PAGES FOR SELECTIONS (Specifier to eliminate Systems not used)

Page 3 of 17

Page 4 of 17

Page 5 of 17

Page 6 of 17

Page 7 of 17

Page 8 of 17

Page 9 of 17

Page 10 of 17

Page 11 of 17

Page 12 of 17

Page 13 of 17

Page 14 of 17

Page 15 of 17 2.2 METALS A. General: Provide metal free from pitting, seam marks, roller marks, stains, discolorations, and other imperfections where exposed to view on finished units. B. Aluminum: Alloy and temper recommended by aluminum producer and finisher for type of use and finish indicated, and with not less than strength and durability properties of alloy and temper designated below for each aluminum form required. 1. Extruded Bar and Tube: ASTM B 221 (ASTM B 221M), alloy 6063-T5/T52. 2. Extruded Structural Pipe and Tube: ASTM B 429, alloy 6063-T6. 3. Drawn Seamless Tube: ASTM B 210 (ASTM B 210M), alloy 6063-T832. 4. Plate and Sheet: ASTM B 209 (ASTM B 209M), alloy 6061-T6. 5. Die and Hand Forgings: ASTM B 247 (ASTM B 247M), alloy 6061-T6. 6. Castings: ASTM B 26/B 26M, alloy A356-T6. C. Brackets, Flanges, and Anchors: Cast or formed metal of same type of material and finish as supported posts, unless otherwise indicated. 2.3 GLASS PRODUCTS AND GLAZING MATERIALS A. Tempered Glass: ASTM C 1048, Kind FT (fully tempered), Condition A (uncoated), Type 1 (transparent glass, flat). Quality q3 (glazing select). 1. Clear glass: Class I (clear). 2. Thickness: 1/4" (6 mm) or 3/8 (10 mm) unless otherwise noted. 3. Manufacturing Process: Manufacture fully tempered glass as follows: a. By vertical (tong-held) or horizontal (roller-hearth) process, at manufacturers option, except provide horizontal process tongless and free of tong marks. 4. Subject to compliance with requirements, provide safety glass permanently marked with certification label of Safety Glazing Certification Council or another certification agency, acceptable to authorities having jurisdiction. B. Glazing Silicone Sealant: Provide CRL 33SC Clear Glazing Silicone Sealant for bonding glass to metal channels. CRL 33SC Clear Silicone Sealant is certified by NSF for food grade applications. 2.4 FASTENERS A. Fasteners for Anchoring Sneeze Guards and Partitions to other Construction: Select fasteners of type, grade and class required to produce connections suitable for sneeze guards and partitions to other types of construction indicated and capable of withstanding design loads. B. Fasteners for Interconnecting Sneeze Guard and Partition Components: Use fasteners fabricated from same basic metal as fastened metal, unless other wise indicated. Do not use metal that are corrosive or incompatible with material joined. 1. Provide metal contact cement or concealed fasteners for interconnecting sneeze guard and partition components and for attaching them to other work, unless exposed fasteners are unavoidable or are standard fastening method for sneeze guards and partitions indicated.

Page 16 of 17 2.5 FABRICATION A. Assemble Sneeze Guards and Partitions in shop to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Clearly mark units for reassembly and coordinated installation. Use connections that maintain structural value of joined pieces. B. Form changes in direction of sneeze guard and partition members as follows: 1. As detailed. C. Mechanical Connections: Fabricate sneeze guards and partitions by connecting members with railing manufacturer s standard concealed mechanical fasteners and fittings, unless other wise indicated. Fabricate members and fittings to produce flush, smooth, rigid, hairline joints. D. Brackets, Flanges, Fittings, and Anchors: Provide manufacturer s standard wall brackets, flanges, miscellaneous fittings, and anchors to connect sneeze guard and partition members to other construction. E. Shear, punch, and drill metals cleanly and accurately. Remove burrs from exposed cut edges. F. Cut, reinforce, drill, and tap components, as indicated, to receive finish hardware, screws, and similar items. G. Close exposed ends of post members with prefabricated end fittings. 2.6 GLAZING PANEL FABRICATION A. Glass Panels: Cut glass to final size and shape before heat treatment (tempering); provide for proper edge clearance and bite on glass. Provide thickness indicated. 2.7 FINISHES, GENERAL A. Comply with NAAMM s Metal Finishes Manual for Architectural and Metal Products for recommendations for applying and designating finishes. B. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. 2.8 ALUMINUM FINISHES A. Finish designations prefixed by AA comply with the system established by the Aluminum Association for designating aluminum finishes. B. High Performance Organic Coating Finish: AA-C12C42Rlx (Chemical Finish: cleaned with inhibited chemicals, Chemical Finish: acid chromate-fluoride-phosphate conversion coating; Powder Coating: as specified below). Prepare, pretreat, and apply coating to exposed metal surfaces to comply with manufacturer s written instructions. 1. Tiger Drylac, Series 39, Polyester Powder Coating, 3 mil. Average film thickness complying with AAMA 2604-98.

Page 17 of 17 PART 3 EXECUTION 1.1 EXAMINATION a. Color and Gloss: As selected by Architect from manufacturer s full range of choices for color and gloss, including custom colors. Selections might include up to four different selections for color. A. Examine substrates, where reinforced to receive anchors, to verify that locations of concealed reinforcements have been clearly marked for Installer. Locate reinforcements and mark locations if not already done. 3.2 INSTALLATION, GENERAL A. Fit exposed connections together to form tight, hairline joints. B. Cutting, Fitting, and Placement: Perform Cutting, drilling, and fitting required for installing Sneeze Guards and Partitions. Set sneeze guards and partitions accurately in location, alignment, and elevation, measured from established lines and levels and free from rack. 1. Do not weld, cut, or abrade surfaces of sneeze guard and partition components that have been coated or finished after fabrication and that are intended for field connection by mechanical or other means without further cutting or fitting. C. Adjust sneeze guards and partitions before anchoring to ensure alignment. Space posts at interval indicated, but not less than that required by design. 3.3 CONNECTIONS A. Nonwelded Connections: Use metal cement or mechanical fasteners for permanently connecting components. Use wood blocks and padding to prevent damage to component members and fittings. 3.4 INSTALLING GLASS PANELS A. Glass, Sneeze Guards and Partitions: Install assembly to comply with manufacturer s written instructions. Attach posts to building structure, then insert and connect factory-fabricated glass panels. 3.5 CLEANING A. Immediately after erection, clean glass and metal surfaces with a mixture of mild soap and water. DO NOT USE abrasive cleaners on glass and metal surfaces. 3.6 PROTECTION A. Protect finishes of Sneeze Guards and Partitions from damage during construction period with temporary protective coverings approved by manufacturer. Remove protective coverings at the time of Substantial Completion. B. Restore finishes damaged during installation and construction period so no evidence remains of correction work. Return items that cannot be refinished in field to shop; make required alterations and refinish entire unit, or provide new units. END OF SECTION 11 4600