Sampling guide for determination of dissolved organic carbon and total dissolved nitrogen in seawater

Similar documents
Practical guide UK Ocean Acidification Research Programme (UKOARP) Carbonate Chemistry Facility

Method Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. EPA/600/R-10/181 December 2010

5 - Chlorophyll Analysis Lab.

Oxygen Demand, Chemical

1. Environmental analysis

EMSL Cryptosporidium and Giardia (EPA 1623/1623.1) Sampling and Shipping Instructions. Instructions for Field Filtered Samples (10 or 50 Liters)

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

Oxygen Demand, Chemical

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

BIOTECTOR TOC Analysers

Group Stormwater Compliance Program Sampling Instructions

Human Myostatin, ELISA Kit (MSTN)

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

TOC SYSTEMS INC. On-Line TOC Analyzer. Features -CHOICE OF PLATFORMS- Options. Combustion ON - LINE HIGH TEMPERATURE COMBUSTION

Process Total Organic Carbon Analyzer

3. Add 0.4 ml of. 7. Use a TenSette

Human Angiotensin 2 (Ang2) ELISA

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

1080 Total Organic Carbon Analyzer

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

Mouse Peptide YY (PYY) ELISA

Human Collagen Type III (COL3) ELISA

COMPOSITION OF SEAWATER

HBeAg and HBeAg Ab ELISA Kit

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

HACH BioTector 3500c ANALYZER FOR TOC, TC, TIC and VOC ANALYSIS

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Torch Combustion TOC Analyzer

Eastman AdapT technical services sample kit procedure

On-Line Total Organic Carbon Analyzer TOC-4200 C391-E083B

6. TOC process analysis

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA

Proper Labeling of Sample Tubes: Tiger Top/SST 5.0 ml Screw Cap Tube

Water-Water Titration for the MicroCal ITC200

3.0 DETECTION LIMIT 3.1. See Procedure ALQAP Procedure for the Determination of Uncertainty

Super Clean Gas Filters Simply the best

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

EXPERIMENT. The Reaction of Magnesium with Hydrochloric Acid; The Molar Volume of Hydrogen

Human immunoglobulin G(IgG) ELISA Kit

Industrial flue gas probes. Instruction manual

Salinity in Seawater

Human IL-1 alpha ELISA Kit

Revised 27 Aug rm (Vers. 4.1)

Safety Data Sheet HEATSINK COMPOUND NS-PCTC8 1 PRODUCT IDENTIFICATION 9 PHYSICAL & CHEMICAL PROPERTIES 2 COMPOSITION/INFORMATION ON INGREDIENTS

Protocol. NEXTERION Slide H. Protein application

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Principles of Gel Filtration Chromatography

Saltwater Analysis Using A High Temperature Total Organic Carbon (TOC) Analyzer with Static Pressure Concentration

ENGI Environmental Laboratory. Lab #2. Solids Determination. Faculty of Engineering & Applied Science

Fusion UV/Persulfate TOC Analyzer

S-0163 Revision B. C-sense pco 2 Sensor

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

Laboratory (LAB) prepares sample kits prior to Epidemiologist Investigator (EPI) arrival.

Rat α-melanocyte stimulating hormone (α-msh) ELISA Kit

EXPERIMENT 3 SOLIDS DETERMINATION

Human connective tissue growth factor (CTGF) ELISA Kit. MyBioSource.com. This package insert must be read in its entirety before using this product.

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Human IL-6 ELISA Set

MyBioSource.com. Human Total Bilirubin (TBB) Elisa kit. (Competitive ELISA)

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

PowerSoil DNA Isolation Kit

Standard Operating Procedure Title: Operation and Calibration of Sievers 820 TOC Analyser

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Bovine Prostaglandin E2 (PG-E2) ELISA Kit

How to safely ship human blood samples from suspected Ebola cases within a country by road, rail and sea

QIAfilter Plasmid Midi Kit (Cat #: 12243)

STANDARD OPERATING PROCEDURE FOR THE COLLECTION OF CHEMICAL AND BIOLOGICAL AMBIENT WATER SAMPLES

Carbon Dioxide Fertilization of Marine Microalgae (Dunalliela sp.) Cultures

foodproof Sample Preparation Kit III

Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

Human anti-hepatitis A virus (HAV) antibody (IgM) ELISA Kit

TOC Application Handbook

2011 NWCA Field Operations Manual Chapter 9. Algae CHAPTER 9. ALGAE

Rat Calcitonin Gene Related Peptide (CGRP) Elisa kit

Instructions for Use

Human rotavirus (RV) antibody (IgG) ELISA kit

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

University Health Services Health and Safety

Can your unit pass a Particulate Emission Compliance Test?

PowerWater DNA Isolation Kit (For isolation of genomic DNA from membrane filtered water samples)

NPTII ELISA Qualitative User Guide neomycin phosphotransferase II Catalog number: PSP 73000

Bovine IgG ELISA Catalog #:

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

MOLYBDENITE CONCENTRATES

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

Instructions for use

Product # 24700, 24750

transport of biological materials

Benefits of On-line Monitoring of Carbon, Nitrogen and Phosphorus

1 MICROTITER PLATE 96 wells 2 ENZYME CONJUGATE 10.0 ml 1 vial 3 STANDARD.1 0 pg/ml 1 vial 4 STANDARD pg/ml 1 vial 5 STANDARD.

STANDARD OPERATING PROCEDURES

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

Part I Assembly of a bioreactor for E.coli fermentation

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Reagent Kit Selection Guide

Transcription:

Sampling guide for determination of dissolved organic carbon and total dissolved nitrogen in seawater Andrew R. Margolin 1, Wenhao Chen 1, Lillian Custals 1,*, Dennis A. Hansell 1 Adapted from Farmer and Hansell (2007) by A.R. Margolin. Updated 4 February 2016. Available online 6 March 2015. For copies of this sampling guide: http://www.rsmas.miami.edu/groups/biogeochem/data/doc-tdn_sampling_guide.pdf For copies of sampling log: http://www.rsmas.miami.edu/groups/biogeochem/data/doc-tdn_sampling_log.pdf http://www.rsmas.miami.edu/groups/biogeochem/data/doc-tdn_sampling_log.docx 1 Rosenstiel School of Marine and Atmospheric Sciences, University of Miami, FL 33149, USA * Corresponding author. E-mail address: lcustals@rsmas.miami.edu (L. Custals).

TABLE OF CONTENTS i. Sampling summary... 1 ii. Photo summary... 2 iii. Return address and shipping instructions... 6 1. Scope and field of application... 7 2. Definition... 7 3. Principle... 7 4. Apparatus... 7 5. Reagents... 8 6. Sampling... 8 6.1. Sample preparation... 8 6.2. Sample collection... 8 7. Procedure... 9 8. Calculation and expression of results... 9 9. Quality assurance... 9 References... 10 i

ii

Sampling guide for determination of dissolved organic carbon and total dissolved nitrogen in seawater Andrew R. Margolin 1, Wenhao Chen 1, Lillian Custals 1,*, Dennis A. Hansell 1 Adapted from Farmer and Hansell (2007) by A.R. Margolin. 1 Rosenstiel School of Marine and Atmospheric Science, University of Miami, FL 33149, USA * Corresponding author. E-mail address: lcustals@rsmas.miami.edu (L. Custals). i. Sampling summary Gloves should be worn during sampling (Fig. 1). It is recommended that anyone sampling from the rosette prior to collection of the samples also wear gloves. Every effort must be made not to touch the sample nipple. Grease should never be allowed to come in contact with the sample nipple. Tubing should be silicone (Fig. 2); under no circumstances should Tygon tubing be used as it is a source of contamination. Label (Fig. 3) polycarbonate (PC) bottles (Fig. 4) with sample-specific information, i.e., cruise, station, cast and Niskin bottle numbers. For DOC/TDN (same for TOC/TN except filter holder and filter are not required): 1. Using forceps (Fig. 6), place precombusted GF/F filter (Fig. 8, 9) in the inline filter holder (Fig. 10, 11, 12) underneath the O-ring (Fig. 12, 13) and cap filter holder (Fig. 14). 2. Connect filter holder to Niskin bottle (Fig. 14) and begin flowing sample through filter. 3. Tilt filter holder so air bubble is under vent cap (Fig. 14). 4. Carefully loosen vent cap to release air bubble, and quickly retighten the cap (Fig. 14). 5. Rinse pre-cleaned 60 ml PC bottle/cap (Fig. 4) adequately three times with filtrate. 6. Bottles should be filled to 75-90% (or ~50 ml) into the 60 ml PC bottle (Fig. 4). 7. The sample bottle should then be capped tightly and frozen upright. 8. Once frozen, samples should be placed in Ziploc bags in an orderly fashion (Fig. 16, 17). 1

ii. Photo summary Figure 1. Gloves for sampling. There should be multiple sizes and enough to share if needed. Figure 2. Inline filter holder with silicone tubing (two typically provided). Figure 4. Pre-labeled PC sample bottles. Sampler will need to include station, cast and bottles numbers. Figure 3. Writing utensils for labeling bottles (Fig. 4) and sampling logs (Fig. 5). 2

Figure 5. Sampling logs and clipboard. Plastic sleeve (if included) can be used for returning filled sampling logs in cooler with samples, or sampling logs can be scanned and emailed to W. Chen. Figure 6. Forceps. Should be rinsed (Fig. 7) after removing used filter (i.e., after every station collection). Figure 7. Clean rinse bottle for Milli-Q water. Figure 8. Pre-combusted GF/F filters. One is all that should be needed for each station. 3

Figure 9. A GF/F filter being handled with forceps before being placed in filter holder. Figure 10. Two provided filter holders with silicone tubing. Figure 11. Inline filter holder with O-ring removed. Figure 12. Inline filter holder with O-ring removed and GF/F filter inserted. 4

Figure 13. Inline filter holder with O-ring placed on top of inserted GF/F filter. Figure 14. Capped inline filter holder with GF/F filter inserted underneath O-ring. Connect silicone tubing to Niskin bottle, begin the flow of sample and tilt so air bubble is underneath vent cap. Carefully loosen vent cap to release air bubble, tighten, and then begin rinsing labeled PC bottle with filtrate three times before filling to ~50 ml mark. Bottles can be carried to Niskin bottle rosette using the provided sampling tray (Fig. 15). Figure 15. Example of provided sampling tray. Can fit up to fifteen 60 ml PC bottles. Figure 16. Ziploc bags for storing frozen samples. Each bag can fit twenty-four 60 ml PC bottles. 5

Figure 17. Once all samples are collected and frozen, all samples and supplies can be packed into cooler for FedEx shipment (should be shipped for next-day delivery). iii. Return address and shipping instructions Lillian Custals RSMAS/University of Miami 4600 Rickenbacker Cswy. Miami, FL 33149 USA If there are questions or issues with shipping, contact Lillian Custals at 305-421-4049 (office) or lcustals@rsmas.miami.edu. 6

1. Scope and field of application This procedure describes a method for the determination of dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) in seawater, expressed as micromoles of carbon (nitrogen) per liter of seawater. The method is suitable for the assay of oceanic levels of dissolved organic carbon (< 400 μmol L 1 ) and total dissolved nitrogen (< 50 μmol L 1 ). The instrument discussed and procedure described are those specific to the instrument employed in the Hansell Laboratory at the University of Miami s Rosenstiel School of Marine and Atmospheric Science. Instruments produced by other manufacturers should be evaluated for suitability. 2. Definition The dissolved organic carbon content of seawater is defined as: The concentration of carbon remaining in a seawater sample after all particulate carbon has been removed by filtration and all inorganic carbon has been removed by acidification and sparging. The total dissolved nitrogen content of seawater is defined as: The concentration of nitrogen remaining in a seawater sample after all particulate nitrogen has been removed by filtration. 3. Principle A filtered and acidified water sample is sparged with oxygen to remove inorganic carbon. The water is then injected onto a combustion column packed with platinum-coated alumina beads held at 680 C. Non-purgeable organic carbon compounds are combusted and converted to CO2, which is detected by a non-dispersive infrared detector (NDIR). Non-purgeable dissolved nitrogen compounds are combusted and converted to NO which, when mixed with ozone, chemiluminesces for detection by a photomultiplier. 4. Apparatus Shimadzu TOC-L with ASI-L auto sampler and TNM-L total nitrogen detector. 7

5. Reagents Not included here. For more information, refer to Farmer and Hansell, 2007. 6. Sampling Proper sampling techniques and handling are essential to good quality data. Care must be taken to minimize contamination of the sample. Sampling from the rosette should be done using clean silicone tubing. Gloves should be worn during sampling. It is recommended that anyone sampling from the rosette prior to collection of the samples (e.g., gases) also wear gloves. If that it not possible, every effort must be made not to touch the sample nipple (the path of the water stream, from Niskin to sample bottle, must be kept very clean). Grease (whether mechanical grease from ship operations or sealing grease, as employed for some gas sampling) should never be allowed to come in contact with the sample nipple. 6.1. Sample preparation Prior to sampling, 60 ml polycarbonate (PC) bottles are cleaned, first by rinsing with distilled water, followed by a 4-hour soak in 10% hydrochloric acid, and then copiously rinsed with distilled water, inverted onto a clean surface and allowed to air dry. All tubing and the polycarbonate inline filter holder should be acid washed and rinsed with copious quantities of distilled water prior to use. Tubing should be silicone; under no circumstances should Tygon tubing be used as it is a source of contamination. GF/F filters should be combusted at 450 C for at least 4 hours prior to use and stored in a sealed glass container. 6.2. Sample collection Whether or not a sample is filtered prior to analysis depends on the goal of the measurement. If DOC and TDN are the variables of interest, then all samples must be filtered. However, the handling of water required for filtration can introduce contaminants, so in some cases filtration may be bypassed. In oligotrophic waters, e.g., where particulate organic carbon (POC) 8

concentrations may be a very small fraction of the total organic carbon, filtering may not be necessary. Since the particles are generally small and homogeneously distributed in a sample, the analysis of unfiltered water results in a good measure of TOC. Likewise, samples collected at depths > 250 m may be left unfiltered as water from these depths normally has low POC loads (< 1 μmol L 1 ). In high productivity areas, a substantial portion of the TOC may be present in particulate form, and many of those particles may be large and so not homogeneously and representatively assessed in the DOC analyzer. In those situations, samples collected between the surface and 250 m are filtered through a precombusted GF/F filter. For consistency when sampling in both oligotrophic and eutrophic environments as part of a study, prefiltering is recommended for all upper layer waters. The GF/F filters are housed in a polycarbonate inline filter holder connected to the Niskin bottle sample nipple with silicone tubing, with collection of filtrate into a precleaned 60 ml PC bottle. PC sample bottles should be labeled with sample-specific information, such as the cruise designation, cast number, and Niskin bottle number. The filter holder, with filter in place, must be well flushed with sample prior to collection into the bottles. The sample bottles should be rinsed three times with sample prior to filling. Bottles should be filled to between 75 and 90%, or 45 to 55 ml into the 60 ml bottle. This volume provides room for expansion of the water on freezing. The sample bottles are then capped tightly and frozen upright. 7. Procedure Not included here. For more information, refer to Farmer and Hansell, 2007. 8. Calculation and expression of results Not included here. For more information, refer to Farmer and Hansell, 2007. 9. Quality assurance On a daily basis, DOC Consensus Reference Material (CRM; Hansell, 2005; http://www.rsmas.miami.edu/groups/biogeochem/crm.html) is analyzed to verify system 9

performance. If the value of the CRM does not fall within the expected range, samples are not analyzed until the expected performance has been established. The Milli-Q water blanks and reference seawater samples analyzed with the samples are used for quality assurance and quality control (QA/QC). By evaluating the performance of these reference waters, instrument drift and performance can be evaluated. If a problem is detected with either drift or performance, the samples are reanalyzed. References Farmer, C.T., Hansell, D.A. 2007. Determination of dissolved organic carbon and total dissolved nitrogen in sea water. In: A.G. Dickson, Sabine, C.L., Christian, J.R. (Eds.) Guide to best practices for ocean CO2 measurements. PICES Special Publication 3, 191 pp. http://cdiac.ornl.gov/ftp/oceans/handbook_2007/sop07.pdf. Hansell, D.A. 2005. Dissolved Organic Carbon Reference Material Program. EOS, 86(35): 318. http://onlinelibrary.wiley.com/doi/10.1029/2005eo350003/abstract. 10