An enhancement of the daylighting from side-window using two-section venetian blind

Similar documents
The effect of shading design and control on building cooling demand

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Solar Shading System Based on Daylight Directing Glass Lamellas

Satyen Mukherjee, Dagnachew Birru, Dave Cavalcanti, Eric Shen, Maulin Patel, Yao-Jung Wen, and Sushanta Das, Philips Research North America

Enhancing visual comfort in classrooms through daylight utilization

Introduction to basics of energy efficient building design

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Analysis of Indoor Luminous Environment and Power Generation by Roll Screen and Venetian Blind with PV Modules

Effect of a Window Shade on Home Energy Use

The potential of simplified concepts for daylight harvesting

SOMFY - PHILIPS Light balancing Whitepaper

Daylighting Design 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design

DAYLIGHTING DESIGN IN A LOW ENERGY BUILDING

optimize daylighting Opportunities

Sustainable lighting design in school buildings

This is the accepted manuscript version of the article

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Comparative Performance of Internal Venetian Blind and Roller Blind with Respects to Indoor Illumination Levels

5.0 Daylighting Analysis (Breathe Study)

A Study on the Variation of Heating and Cooling Load According to the Use of Horizontal Shading and Venetian Blinds in Office Buildings in Korea

CLIMATE BASED SIMULATION OF DIFFERENT SHADING DEVICE SYSTEMS FOR COMFORT AND ENERGY DEMAND. 6952, Switzerland Canobbio

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

THE USE OF LIGHT PIPES FOR DEEP PLAN OFFICE BUILDINGS A case study of Ken Yeang's bioclimatic skyscraper proposal for KLCC, Malaysia

MODELLING THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING PERFORMANCE OF AN OFFICE BUILDING IN SINGAPORE USING ENERGYPLUS

Energy efficient lighting

We ve cracked the code to harness the sun

Daylighting Design Principles and the LightLouver Daylighting System

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Pe r f o r m a n c e As s e s s m e n t of

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Daylight Savings Calculation Technique for Smart Buildings

Chapter 5 Glazing Properties

Cost Benefits of SunGuard SN 54

DESCRIPTION OF STRATEGY

Volumetric study of multi-purpose school hall and its impact on visual and energy performance

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

Introduction to Skylighting in equest Quick Energy Simulation Tool

61 Flavors of Daylight

LIGHTFLEX Tunable-White LED Tubular Daylighting System. Smart. Simple. Sustainable.

AIC TECH 2015 Sustainability in Practice Turning Ideas into Reality Jan 16, 2015 FUTURE & NET ZERO BUILDINGS

ResearcH JournaL 2011 / VOL

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Climate Analysis. Daylighting uses solar angles, cloud cover/precipitation, and context. Temperature. Humidity. Precipitation. Wind.

Daylight, Solar Gains and Overheating Studies in a Glazed Office Building

Ground Factors and Lighting Design in an Urban Area: Daylight Availability and Light Pollution Risk


In the earliest days of architecture, strategies like daylight harvesting and

Daylight Dimming Systems: Studies in Energy Savings and Efficiency

MODELING FENESTRATION WITH SHADING DEVICES IN BUILDING ENERGY SIMULATION: A PRACTICAL APPROACH

Thomas Brown, Architect, LEED-AP. Part 5 Daylighting Strategies Shading Case Studies

Daylighting Guide for Buildings

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

Hybrid lighting systems: A feasibility study for Europe

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

JAKARTA GREEN BUILDING USER GUIDE VOL. 1 BUILDING ENVELOPE. The Government of the Province of Jakarta Capital Special Territory

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Complying with the Minimum Energy Efficiency Standards (MEES)

Green Building Guideline of Jordan

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Bringing a little sunshine into our lives

made possible by Lutron

NATIONAL TECHNICAL UNIVERSITY OF ATHENS School of Electrical and Computer Engineering. Lighting Controls. Lambros T. Doulos.

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

DYNAMIC DAYLIGHT SIMULATION AND VISUAL COMFORT SURVEY IN MEDITERRANEAN CLIMATE. CASE STUDY IN OFFICE BUILDING.

Green Building Guideline of Jordan

Daylight Efficiency Prediction of Courtyard vs. Conventional Building Models Using Simulation Tool under Specific Climate Conditions

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

Volume 8, ISSN (Online), Published at:

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Smart. Easy. Profitable.

The Performance of External Shading Devices and Daylighting Rule of Thumb for a Tropical Climate

This is the author s version of a work that was submitted/accepted for publication in the following source:

Assessment of shading devices with integrated PV for efficient energy use

NEED FOR A CORRECT GLASS DESCRIPTIVE CODE: ENERGY-CODING

Italcementi Center for Research and Innovation

Effect of Building Shape And Neighborhood Design On Solar Potential And Energy Performance

Energy saving through Building Envelope Innovation: Smart Skin Design

LED Lighting and Retrofit Design

CLARIS. Think Outside The Tube. LED RETROFIT KITS Revolutionary By Design

COMPARISION OF FIVE WINDOW SHADE STRATEGIES

SET. Solar control of extensively glazed facades. a computer method for predicting the effects of various devices and building s thermal inertia

Teaser Project Munich

EVALUATION OF A PROTOTYPE SOLAR AWNING

Passive Solar Building Design Guidelines and Recognition Program

Rooms The function Rooms contains the following window.

This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

Designing carbon neutral schools: The Victor Miller Building, a critical review

LIGHTING/ELECTRICAL REPORT

caused by subjective factors such as oversimplified modeling for simulation, nonuniform calculation methods, casual input parameters and boundary cond

Chapter 2 Daylighting

Principles of Ventilation and Air Conditioning Design & Installation

Saving energy using the sun as a lighting source

THERMAL CHARACTERISTICS OF A DOUBLE-GLAZED EXTERNAL WALL SYSTEM WITH ROLL SCREEN IN COOLING SEASON

Transcription:

An enhancement of the daylighting from side-window using two-section venetian blind Vichuda Mettanant 1,2, Pipat Chaiwiwatworakul 1,2,*, Pattana Rakkwamsuk 3 1 The Joint Graduate School of Energy and Environment, King Mongkut s University of Technology Thonburi, Bangkok, Thailand 2 Center of Energy Technology and Environment, Ministry of Education, Thailand 3 School of Energy, Environment and Materials, King Mongkut s University of Technology Thonburi. Abstract: In the tropics, daylighting from a side window requires shading to intercept direct sunlight from entering the window whilst allowing penetration of daylight from sky. Daylighting from a double-pane glazed window with enclosed horizontal slats has long been investigated under different climates and locations. In this paper, a double-pane window with the slats that were separated into two sections (lower and upper sections) was investigated for its daylight application in tropical climate. A series of full-scale experiments and simulations were conducted under real tropical skies and by which the slats in each section were tilted to different angles. Through the yearly simulations, performance of the two-section slat window was evaluated in terms of useful daylight illuminance (UDI), average interior daylight illuminance (ADI), and reduced light power density (LPD) of a dimmable lighting system. The results show that the two-section slat window can enhance the daylight use in the building by increasing more useful daylight illuminance, and providing better uniformity of the interior daylight distribution than the single-section slat window. Keywords: Vertical slats; Daylighting; Illuminance; Useful daylight illuminance; Tropical climate *Corresponding author. Tel.: +662-872-9014 ext. 4107, Fax: +662-872-7978 e-mail address: pipat_ch@jgsee.kmutt.ac.th 1. Introduction In tropical region, daylight from sky is voluminous (Chirarattananon et al., 2002), and the sun travels in all orientations over the sky vault. Nowadays, commercial buildings in Thailand are constructed with large glazed windows and no external shading. To avoid adverse effects of excessive solar gain, low optical transmittance glasses (heat reflective glasses) are suggested for the usage. This practice leads to loss of beneficial gain from the daylight use. Such buildings need full reliance on electric lighting even when the daylight is sufficient for the illumination (Kim et al., 2009). The window with horizontal slats enclosed between two glass panes (slat window) is an interesting solution to the above traditional practice of the building envelope design. However, the daylight through the slat window is complicate. Optical properties of glass window and slats, tilted slat angle, sky condition influence largely on the daylight transmission and its interior distribution (Athienitis and Tzempelikos, 2002; Edmonds and greenup, 2002). Mathematical models have been developed to predict the interior workplane illuminance from the slat window (Chaiwiwatworakul et al., 2009; US-DOE, 2004). Some studies conducted daylight simulations to optimize configurations of the window and slats (Kim et al., 2009; Koo et al., 2010). Most studies focused on the slats that are tilted with same angle for the whole section. Recently, Hu and Obina (Olbina, 2012; Hu, 2011) introduced a double-pane window with multiple-section slats. The slats that each section can be adjusted to different tilted angles enhance the daylight use in building. This paper investigates such feature of a double-pane window unit with two-section slats for its application and performance in tropical climate. 2. Methodology Full scale experiments were conducted to measure the daylight transmitted from a two-section slat window and its distribution in an interior space. The test room was a rectangular shape with interior dimensions of length 6.00 m. and width 3.00 m. The room height was 2.65 m. measured from the floor to the ceiling. In experiments, the interior daylight was measured at three points located on a line perpendicular to the window wall across the center of the room on the work plane level (0.75m above floor). The points were positioned along the line at 10%, 50%, and 90% depths of the room 362

(D). A data logging system was used to acquire all measured data from the sensors every five minutes. During the experiments, exterior daylight illuminances were measured by a daylight station. At the station, daylight of global, diffuse horizontal and beam normal components have been measured. With the facilities above, a series of experiments were performed. The measurement results of daylight illuminance from the experiments were compared to those obtained using a daylight calculation algorithm described in (Chaiwiwatworakul et al., 2009). 3. Results and discussion A series of experiments was conducted to measure the interior daylight from the two-section slat window. Two experiments made with two different proportions of the lower and upper slat sections are chosen for presentation. The experimental measurements were also compared with the calculations using the algorithms described in previous section. 3.1 Experiment with the Lower-to-upper Slat Section 80:20 This experiment was conducted on 23/2/2013. The angles of slats in the lower and the upper sections were set at 15 and -30, respectively. Fig. 1(a) exhibits a plot of the global and the diffuse daylight illuminance on the experimental day. Variation of sky ratio, the ratio of the diffuse to global irradiance, was also presented in the plot. On this day, the sky was clear in the morning but partly cloudy in the afternoon. (a) Exterior daylight illuminance (b) Interior daylight illuminance Fig. 1 Measurement of daylight illuminance on the experiment of 80:20 slat window (23/2/2013) Fig. 1(b) exhibits results of the measurements of interior daylight at 10%, 50% and 90% depth of the room (D). It can be observed that the workplane daylight illuminance at 10%D is high upto 1800 lux during noon and drop rapidly to about 500 lux and 300 lux at 50%D and 90%D, respectively. It should be reminded that without the slats the beam daylight would penetrate into the room and caused highly non-uniform illuminance distribution and a serious glare problem. Fig. 1(b) also exhibits that the calculation algorithm can perform well the prediction of the interior daylight illuminance from the two-section slat window. 3.2 Experiment with the Lower-to-upper Slat Section 50:50 This experiment was conducted on 31/10/2012. In the experiment, the slat angle was at -30 for both lower and upper sections. On the experimental day, the sky was cloudy for most of the time. The sunlight appeared only from 14:30 to 16:30. From the plot in Fig. 2(b), it can be observed again a good agreement between the measurements and the calculations. (a) Exterior daylight illuminance (b) Interior daylight illuminance Fig. 2 Measurement of daylight illuminance on the experiment of 50:50 slat window (31/10/2012). 363

Annual Average Interior Daylight Illumminance (lux) 5th International Conference on Sustainable Energy and Environment (SEE 2014): Comparing the results with those on 23/2/2013, the interior daylight near the window reaches 1500 lux (at 12:30), even though the exterior daylight is lower. The negative slat angle tends to increase the interior daylight in the near-window area. 3.3 Simulation-based Analysis The algorithm in (Chaiwiwatworakul et al., 2009) was used to simulate the interior daylight from the two-section slat window facing south for a whole year. A complete one-year hourly record of the daylight measured in Thailand was used for the simulation. The ASRC-CIE sky model was adopted to calculate the resulting diffuse skylights on slat surfaces and the luminances of the sky patches viewed through the slats by points in the model room. In the simulation, a model room was set similar to the test room but its length was extended to 15 m allowing daylight to penetrate deep into the interior without the limit of room depth. Values of the interior surface reflectance were defined to 0.7 for ceiling, 0.5 for walls and 0.3 for floor identical to those in the IES Lumen method for daylight calculation (Reas, 2000). No modification was made for the blind properties and the window was due south. A series of the simulations was performed by varying the slat angle in upper and lower sections from -60 to 60 at 10 step size. The ratio of upper and lower slat sections is kept at 50:50. 3.4 Daylighting Performance The two-section slat window was evaluated on its daylighting performance using two indicators (i) annual average interior daylight illuminance (ADI) and (ii) useful daylight illuminance (UDI). In Fig.3, ADI is shown. The labels in the plot are referred to angles of the upper slats. The values in the horizontal axis are angles of the lower slats. As reference case, The ADI values of a window using heat reflective glass without blinds is shown as horizontal line in the plot (at 201.32 lux). The ADI values of one-section slat window at various blind angles are included in the plot for comparison, as well. When lower blind angles are positive, most of the ADI values of window with two-section blinds are higher than that with one-section blinds, and vice versa. The maximum ADI value occurs when upper and lower blind angles of two-section slat window are set at -30 and -20 degree, respectively. 900 800 700 600 500 400 300 200 100-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 Lower Blind Angle (degree) Fig. 3 ADI of the two-section slat window. According to UDI definition, Fig. 4 (a) to (c) exhibit the occurrences of the workplane daylight illuminance within the useful range of 100-2000 lux from the slat window at different points inside the room. D/H values indicate the ratio of depth of the room measured from the window to height of the window. From Fig. 4(a), at D/H=1, the window with upper and lower blind angles at 20 and 60 degree, respectively, gives the maximum UDI values of 98%. At D/H=3, the UDI values are high for all cases. However, the two-section slat window with upper and lower blind angles at -10 and - 30 degrees, respectively, gives the highest UDI values of 98%, as shown in Fig. 4(b). The trend of the results at D/H=1 is opposite to the results at the rest positions of the room. For all angles of the lower slats, the upper blind angle of -30 degree provides the lowest UDI at D/H=1 because the window introduces excessive daylight into the area, while the UDI values of the window at -30 degree upper blind angle are highest at other positions in the room. -60deg -50deg -40deg -30deg -20deg -10deg 0deg 10deg 20deg 30deg 40deg 50deg 60deg 1 section blinds Heat Reflective Glass 364

Excluding the position at D/H=1, the single-section slat window at -20 degree provides the highest UDI value in average because it gives maximum UDI values at D/H=5 and 7 as shown in Fig. 4(c) and (d). The daylight has no potential in the area deeper than the position of D/H=7 (room depth is seven times of the window height). In this area, the UDI values are 0 for most of the time for all window types so they are not plotted here. There is no single slat angle that can provide high daylight performance at all position in the room. However, when upper blinds are set at negative angles in the range of -30 to -10, a person in a room can view the sky at relatively higher portion. Therefore, more daylight can penetrate into a room. As a results, when the upper blind angles of - 30, -20, and -10 are applied, high UDI values are obtained at the position of D/H = 3 and 5 while the lower blind angles do not affect much to the UDI values. At most of the slat positions, windows with blinds provide better daylight performance than window using heat reflective glass. (a) Annual average UDI at D/H = 1 (b) Annual average UDI at D/H = 3 (c) Annual average UDI at D/H = 5 (d) Annual average UDI at D/H = 7 Fig. 4 Annual average UDI of the window. 3.5 Energy Saving In this section, the energy savings from electric lighting is evaluated for the room model. It is assumed that the light luminaires on the room ceiling provided uniformly a target illuminance on workplane level (0.75 m. above floor) regardless of daylight. Each luminaire was housed with two T8 fluorescent lamps (36W) and one electronic ballast (2W). One lamp produced the light flux of 2,680 lumens. By Lumen method calculation and a Coefficient of Utilization value (CU) of 0.50 for typical lighting design, the light power densities (LPD) of lighting to provide the illuminance at 500 lux were calculated at 17.26 W/m 2. For the base case, all the lamps were fully turned on during typical office hours 8:00-17:00 for five days a week (Monday-Friday). A dimming controller was integrated with the lighting system to regulate the light from lamps to supplement the daylight from the slat window. The lighting system however consumed electric power at 10% of its rated even when the daylight alone could illuminate the space at target illumination level or excess. 3.6 Lighting power density According to the TIEA-DG003.2003 standard of the Illuminating Association of Thailand (TIEA), recommended illumination levels for office areas are in a range of 300 to 800 lux. The LPD values of the two-section slat window of the dimmable lighting system at three required illuminance levels 365

Annual Average Heat Gain through Window (Wth) Annual Average Lighting Power Density (W/m2) 5th International Conference on Sustainable Energy and Environment (SEE 2014): which are 300, 500 and 800 lux are studied. By Lumen method calculation, the LPD of lighting to provide the illuminance at these three levels were calculated at 10.36, 17.26, and 17.26 W/m 2, respectively. The results show that at higher required illuminance level, the LPD requirement increases. However, the patterns of the LPD requirement at these three illuminance levels are similar because daylight potential is identical at the same outside conditions. As the consequence, the interior illuminance distributions of natural light are the same. Therefore, only the results at 500 lux required illuminance are shown here. The results of annual average LPD at 300 and 800 lux required illuminance levels are in the range of 4.63 to 7.22 and 15.38 to 22.94 W/m 2, respectively. The average LPD values per year of window with heat reflective glass are 6.79 and 21.66 W/m 2 for the cases of 300 and 800 lux required illuminance levels, respectively. 13.5 13.0 12.5 12.0 11.5 11.0 10.5 10.0 9.5 9.0 8.5 8.0-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 Lower Blind Angle (degree) -60deg -50deg -40deg -30deg -20deg -10deg 0deg 10deg 20deg 30deg 40deg 50deg 60deg 1 section blinds Heat Reflective Glass Fig. 5 Annual average LPD of the window at 500 lux required illuminance level. Because of the high daylight potential of upper blinds when the upper blinds are set at negative angles in the range of -30 to -10, their LPD values are low. According to the same reason, singlesection slat window at -20 degree provides the lowest LPD value at all illuminance level requirements and provides the maximum electricity saving from lighting system at 31% comparing to heat reflective glass window. As shown in Fig. 5, a room using window with blinds requires lower electricity from lighting system than that using window with heat reflective glass, except that tilt angles of both upper and lower blinds are high at 50 and 60 degree. 3.7 Thermal heat gain through window For tropical region, cooling is dominant. Daylight penetrates through window along with heat which becomes cooling load of an air-conditioning system. When blind angles are negative, there are high chances that blind slats tilt parallel to beam solar radiation which enters the room. For this reason, the results of negative blinds angles show higher heat gain through window as shown in Fig. 6. At very high degrees of blind angles both in positive and negative directions such as -50, -60, 50, and 60 degree, heat gain through window reduces because the blind slats are almost close and beam radiation cannot penetrate through gaps between blind slats. 400 350 300 250 200 150 100-60 -50-40 -30-20 -10 0 10 Lower Blind Angle (degree) 20 30 40 50 60 Fig. 6 Annual average heat gain through window (thermal Watt) Examine again Fig. 4 and 6, for single-section slat window, when the blind angles provides high daylight potential, they also have high heat gain through window, and vice versa. Two-section slat window provides better flexibility for daylight use compared to single-section slat window because heat gains through window are the same for the same combination of slat angles. For example, see Fig. 6, the window with upper and lower sections at -30 and 30 degree blind angles has the same -60deg -50deg -40deg -30deg -20deg -10deg 0deg 10deg 20deg 30deg 40deg 50deg 60deg 1 section blinds Heat Reflective Glass 366

heat gain through window with the window with upper and lower sections at 30 and -30 degree blind angles. As shown in Fig. 4, the window with upper and lower sections at 30 and -30 degree blind angles provides higher ADI because higher portion of the sky can be seen from the occupancy. Fig. 7 exhibits total electric energy savings of the room using two-section slat window based on the room using heat reflective glass window. The total electric energy saving composes of electric energy savings from the dimmable lighting system and the room s air-conditioning system. The electricity saving from lighting system depends on the LPD values as a consequence of daylight performance, while the energy saving of the air-conditioning system is an effect of cooling load due to lighting system and heat gain through window. Therefore, daylight performance has the major effect on the total energy saving because it influences both in lighting system and air-condition system. As show in Fig. 7 (b) and (c), window with upper blinds which are set at negative angles in the range of -30 to -10, provides high savings at all lower blinds angles due to their high daylight performances. Especially when the room is designed for high illuminance level (800 lux), high daylight level is required; consequently, the maximum saving occurs at the highest daylight performance window, -20 single-slat window. This is not the case when the room is designed for low illuminance level (300 lux). Heat gain through window plays more important low to the total energy requirement. High daylight level becomes excessive. As a result, two-section slat windows with positive angles at the lower section provide higher energy saving because less heat gains through window in these cases while their daylight performances are comparable. (a) 300 lux required illuminance level (b) 500 lux required illuminance level (c) 800 lux required illuminance level Fig. 7 Annual average electric energy savings. 4. Conclusion Daylighting from a two-section slat window was investigated under tropical climate. A model was developed to simulate the interior daylight transmission through the window. The study results show that when the slats in the lower and the upper sections were tilted to proper angles, the twosection slat window can enhance the interior daylight use beyond the one-section slat window. It can also improve the uniformity of the interior daylight distribution. The two-section slat window and dimmable electric lighting system, when used in a room with the same configuration as that of the experimental room, can utilize daylight to save about 31% of electric lighting energy and 26% of the total electricity. 5. Acknowledgement The financial support from the Engineering and Physical Sciences Research Council (EPSRC) through this research project on Energy and Low Income Tropical Housing (EPSRC Reference: 367

EP/L002604/1) is gratefully acknowledged. 6. References US Department of Energy (US-DOE). 2004. EnergyPlus engineering document: the reference to EnergyPlus calculations. Athienitis, A.K. and Tzempelikos, A. 2002. A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device. Solar Energy 72(4): 271 281. Chaiwiwatworakul, P., Chirarattananon, P., and Rakkwamsuk, P. 2009. Application of automated blind for daylighting in tropical region. Energy Conversion and Management 50: 2927 2943. Chirarattananon, S., Chaiwiwatworakul, P., and Pattanasethanon, S. 2002. Daylight availability and models for global and diffuse horizontal illuminance and irradiance for Bangkok. Renewable Energy 26(1): 69 89. Edmonds, I.R. and Greenup, P.J. 2002. Daylighting in the tropics. Solar Energy 73(2): 111 121. Hu J., Olbina S. 2011. Illuminance-based slat angle selection model for automated control of split blinds. Building and Environment 46: 786-796. Kim, J.H., Park, Y.J., Yeo, M.S., and Kim, K.W. 2009. An experimental study on the environmental performance of the automated blind in summer. Building and Environment 44: 1517 1527. Koo, S.Y., Yeo, M.S., and Kim K.W. 2010. Automated blind control to maximize the benefits of daylight in buildings. Building and Environment 45: 1508 1520. Olbina, S., Hu, J. 2012. Daylighting and thermal performance of automated split-controlled blinds. Building and Environment 56: 127-138. Reas, M.S. 2000. Daylighting. Lighting handbook: reference and application. Illuminating Engineering Society of North America (IESNA) [chapter 8]. 368