Measuring oxygen transfer efficiency (OTE) at the Eindhoven WWTP using real-time off-gas analysis in circular aeration tank

Similar documents
Keywords: Activated Sludge, Integrated Fixed-Film, Oxygen Transfer, Nutrient Removal, Energy Footprint

Oxygen Transfer in a Biological Aerated Filter

2/22/2011. Presentation Outline. Overview of Wastewater Aeration. Basic Equation. Some Acronyms. dc dt. dc dt TDS BP T C L

8.8 Calculation of oxygen requirements Peder Maribo

Aeration University Advanced Concepts in Energy Efficiency

Aeration Systems Past, Present and Future. What to Expect from Aeration System Upgrades

REHAU POLYMERS PVT. LTD

JET-LOOP SYSTEM. The Jet-Loop System applies for aerobic wastewater treatment using ejector(s) as the mechanical system for aeration.

OPERATION AND MANAGEMENT OF WASTEWATER TREATMENT PLANTS

ENERGY-CONSERVATION IN FINE PORE DIFFUSER INSTALLATIONS IN ACTIVATED SLUDGE PROCESSES

IWA Publishing 2012 Water Practice & Technology Vol 7 No 3 doi: /wpt

Feedforward aeration control of a Biocos wastewater treatment plant

Sanitary and Environmental Engineering I (4 th Year Civil)

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

AERATION EFFICIENCY FOR A LEACHATE TREATMENT PLANT

Module 19 : Aerobic Secondary Treatment Of Wastewater. Lecture 24 : Aerobic Secondary Treatment Of Wastewater

Outline. Introduction Case Studies. Anoxic Zone Mixing Channel Mixing. Theory and Criteria. Mixing Theory Design Criteria.

Modelling of Wastewater Treatment Plants

WASTEWATER TREATMENT SYSTEM

AquaNereda Aerobic Granular Sludge Technology

19. AEROBIC SECONDARY TREATMENT OF WASTEWATER

The Fate of Ammonia in Facultative Lagoon Sludge Treatment Processes: An Investigation of Methods for Reducing Ammonia in Recycle Streams:

Fixed-Film Processes

Wastewater Treatment - Energy Saving Opportunity

Monte Carlo Analysis for Aeration Design

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

INTRODUCTION OF THE IC REACTOR IN THE PAPER INDUSTRY

PRINCIPLES AND APPLICATIONS OF JET AERATION

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

Vortex Separator. May be more cost-effective pre-treatment devices than traditional wet or dry basins.

19. AEROBIC SECONDARY TREATMENT OF WASTEWATER

Activated sludge modeling of Vale Faro Waste Water Treatment Plant

Modelling the WWTP of Nîmes and Validating the Ammonair Control Algorithm to Ensure Low Energy Consumption and N 2 O Emissions

KEY WORDS Anaerobic lagoons ; reaction constant ; operation ; per capita sludge ; loading rate.

General Information on Nitrogen

Technical Bulletin 132. Diffused Air Mixing Requirement. by:

Wastewater Treatment Technology and Applications in Industrial Facilities

TWO YEAR CASE STUDY OF INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS) AT BROOMFIELD, CO WWTP West 124th Street Broomfield, CO 80020

Air Stripping. Aeration Offers Dealers More Than They May Realize. By Gary L. Rogers

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

Effect of the temperature on the performance of a sludge activated petrochemical wastewater treatment plant

Application of the AGF (Anoxic Gas Flotation) Process

ENVIRONMENTAL VISITATION CENTER ALEGRIA WWTP

Gustavo Andrés Baquero-Rodríguez Research Scholar, Ciencia e Ingeniería del Agua y el Ambiente, Pontificia Universidad Javeriana, Bogotá, Colombia.

VARI-CANT Jet Aeration Systems. Water Technologies

A NEW METHOD FOR EVALUATING PRIMARY CLARIFIERS Alex Ekster and Cristina Pena San Jose/Santa Clara Water Pollution Control Plant City of San Jose

High-Frequency Field Measurement of Nitrous oxide (N 2 O) Gas Emissions and Influencing Factors at WWTPs under Dry and Wet Weather Conditions

Outline Introduction Membrane Issues Other Issues

DESIGN OF A DECENTRALISED WASTEWATER TREATMENT PLANT FOR NYARI ESTATE

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

USING NUMERICAL SIMULATION SOFTWARE FOR IMPROVING WASTEWATER TREATMENT EFFICIENCY

COMPARISON STUDY BETWEEN INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS), MEMBRANE BIOREACTOR (MBR) AND CONVENTIONAL ACTIVATED SLUDGE (AS) PROCESSES

Unit Treatment Processes in Water and Wastewater Engineering

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

THE INFLUENCE OF CARRIER SIZE AND SHAPE IN THE MOVING BED BIOFILM PROCESS

Activated Sludge Treatment Extended Aeration (EA) and Sequencing Batch Reactor (SBR) Systems

A Novel Comprehensive Procedure for Estimating Greenhouse Gas Emissions from Water Resource Recovery Facilities

Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by Centrifugation

Aeration control in a full-scale activated sludge wastewater treatment plant: impact on performances, energy consumption and N2O emission

New anaerobic technologies More biogas at lower costs

Chapter 11. Secondary Clarifiers

MBBR Wastewater Treatment Processes

Biobed Advanced EGSB & Biothane Advanced UASB. Wastewater as a Resource WATER TECHNOLOGIES

WATER QUALITY ENGINEERING

THE NEW DUBBO SEWAGE TREATMENT PLANT UPGRADE. Glenn Clifford. Dubbo City Council

Field and CFD Analysis of Jet Aeration and Mixing

CTB3365x Introduction to Water Treatment

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

Aeration System Improvements with a 5-Year Payback. Scott Phipps

DO is one of the most important constituents of natural water systems; as fish and other aquatic animal species require oxygen.

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

Ovivo Carrousel Systems

Proposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant

Calculating Aeration Flow and Pressure Requirements

Sixteenth International Water Technology Conference, IWTC , Istanbul, Turkey 1

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

Case History: Anaerobic and Aerobic Treatment of Textile Wastes at South Carolina Textile Plants. Introduction

IMPROVEMENTS IN MODELLING DISSOLVED OXYGEN IN ACTIVATED SLUDGE SYSTEMS. Jacek Makinia*, Scott A. Wells**

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng

Lysis and Autooxidation. Organic Nitrogen (net growth) Figure by MIT OCW.

Proposal by Russia to delete hot spot 18.2

Activated Sludge Process Optimisation AERATION PERFORMANCE. Application Note XAUK WW

Activated Sludge Processes

Water and Wastewater Engineering Dr. Ligy Philip Department of Civil Engineering Indian Institute of Technology, Madras

Lab 6 - Pumping Test. Pumping Test. Laboratory 6 HWR 431/

Nutrient Removal Processes MARK GEHRING TECHNICAL SALES MGR., BIOLOGICAL TREATMENT


Supplemental Information for

Liquid Stream Fundamentals: Grit Removal

Screening, Definition: The unit involved is called a screen.

Sustainability and Innovation

COD REMOVAL OF CARDBOARD FACTORY WASTEWATER BY UPFLOW ANAEROBIC FILTER

WASTEWATER TREATMENT

Figure Trickling Filter

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

SOLUTIONS AND EQUIPMENT FOR LEACHATE TREATMENT

DETERMINATION OF BIOLOGICAL KINETIC CONSTANTS USING RESPIROMETRY FOR THE WATER9 AIR EMISSIONS MODEL

Recycling of Food Processing Wastewater to Potable Water Standards

WWTF Capacity Assessment Project

Transcription:

Measuring oxygen transfer efficiency (OTE) at the Eindhoven WWTP using real-time off-gas analysis in circular aeration tank G. Bellandi*, S. Plano*, **, D. Rosso**, T. Maere,*, W. De Keyser*, S. Weijers***, T. Flameling*** and I. Nopens* * BIOMATH, Department of Mathematical Modelling, Statistics and Bioinformatics, Ghent University, Coupure Links 63, B-9 Gent, Belgium (E-mail: Giacomo.Bellandi@UGent.be; Salvatore.Plano@UGent.be; Ingmar.Nopens@UGent.be) ** Department of Civil and Environmental Engineering, University of California, Irvine, USA (E-mail: bidui@uci.edu) *** Waterschap De Dommel, 8 Boxtel, The Netherlands Abstract Aeration efficiency in the activated sludge basin of the Eindhoven wastewater treatment plant was monitored during two off-gas measurement campaigns using the ASCE method for oxygen transfer testing. Different locations were sampled and revealed differences in αsote values both in tangential as in radial direction. The highest values were found at the end of the aeration zone (ca. 38%), the lowest at the start (ca. 3%) and intermediate values in between. Differences in the radial direction were negligible at the start of the aeration zone, but became more significant towards the end. This hints that homogeneity in terms of OTE can be assumed at the start of the aeration zone, but does not longer hold at the end of the aeration zone. Keywords Activated sludge model; Aeration; Off-gas test; Oxygen transfer efficiency INTRODUCTION As one of the most economically important contributors to operational costs of daily operation of a wastewater treatment plant (WWTP), to aeration has been given ample attention with regard to its contribution to process energy footprint (Reardon, 199). Several methods for aeration efficiency measurements (steady-state, non steady state, with and without the addiction of chemicals) have been presented in literature and reviewed in US EPA (1989) and STOWA (9). The steady-state testing is described in detail by the ASCE standard protocol for off-gas testing (ASCE, 1997). This test gives the possibility to a modeller to compare plant aeration efficiency (expressed as oxygen transfer efficiency OTE and its standardised form SOTE) with the existing process models and evaluate discrepancies or lack in model structure. The currently available models are typically based on the product of the gradient between local dissolved oxygen (DO) and the DO concentration at saturation (i.e. DO*), with the oxygen transfer coefficient k l a (i.e. mass transfer coefficient k l multiplied by the gas-liquid interfacial area a). This approach accounts for the influence of process conditions by correcting DO* and k l a as function of temperature. Correction for other influences like barometric pressure and salinity is not routinely done. Compared to the more elaborated bioprocess models, the current aeration models are very simple, and do not fully take into account the complexity of the oxygen transfer mechanism. This process depends on different conditions, both configurational and operational (Gillot and Heduit, 8). The former includes diffuser submergence (Capela et al., ), surface area, diffuser layout and placement (Gillot et al. ) while the latter includes physical factors like salinity, atmospheric pressure, elevation, reduction of efficiency due to dissolved contaminants in the process water (surfactants, inorganics) (Capela et al., ; Rosso and Stenstrom, 6), membrane fouling (Frey and Thonhauser, 4; Wagner and Loock, 7; Gillot and Heduit, 8), and sludge retention time (Rosso et al, ). The goal of this research is twofold: (1) apply the measurement technique and () investigate the dynamic

nature of oxygen transfer with regard to the location in the aerated zone, including the impact of influent load and aeration control. The novel aspect is the application in a deep orbital ditch process with high internal recirculation and horizontal liquid velocity. This information is to be used to decide whether a constant or dynamic OTE is to be used in the Eindhoven WWTP model. MATERIALS AND METHODS Off-gas testing Aeration efficiency was monitored in the aerated zone of the Eindhoven WWTP by means of the off-gas test (Redmon et al., 1983), using the process water testing protocol (ASCE, 1997). The offgas equipment was composed of a reinforced polyethylene hood floating on the wastewater surface (1. m x 1. m x.3 m, LxWxD). The hood was connected to the off-gas analyser (evolution of the analyser in Leu et al, 9) through a flexible hose (diameter ~ 4mm). By means of a vacuum pump a small fraction of the off-gas was diverted from the main hose to a desiccator/adsorption unit to remove water vapour and CO, and then circulated inside a zirconium oxide fuel cell (AMI Model 6, Advanced Micro Instruments, USA) to measure oxygen partial pressure. Ambient air was sampled by means of a three-way valve at the start and end of each experiment as reference for the efficiency evaluation. The percentage of oxygen transferred to the liquid phase (i.e. OTE) was calculated from the oxygen content measured in the off-gas and the reference fraction in the ambient air as follows: OOOOOO = OO iiii OO oooooo OO iiii (1) where O in is the mass flow of oxygen measured in the influent air supplied and O out is the mass flow in the off-gas. Dissolved oxygen was recorded by means of an LDO probe (Hach-Lange) attached underneath the floating hood, in order to correct for variable DO gradients during the oxygen transfer process. A schematic of the off-gas set-up is shown in Figure 1. Figure 1 Schematic diagram of the off-gas set-up Eq 1 allows the calculation of OTE without the need of knowing the airflow rate. The standard oxygen transfer efficiency in process water (αsote, %) can be computed as: αααααααααα = OOOOOO DDDD SS (ββ DDDD SSTT DDDD) θθ( TT) () where standard conditions (i.e. C, mean atmospheric pressure, zero dissolved oxygen and zero

effect of salinity) have been defined from ASCE (1984, 1991, 7) and included here as multiplication factors. In particular β is the factor that quantifies the process water salinity effect on transfer efficiency and is defined by Stenstrom and Gilbert (1981) as the ratio of oxygen saturation in process water to clean water or DO * /DO * cw. This coefficient is indeed used to adjust the calculated oxygen value (Baca and Arnett, 1976) at half of the depth (Metcalf & Eddy, 3) at saturation (DO * ST) to the process water conditions. The α factor is the correction coefficient for the effect of contaminants on transfer efficiency in particular this is defined as the ratio of process water to clean water mass transfer coefficient (i.e. K L a pw /K L a cw ). The value of oxygen saturation in clean water at C has been calculated as DO * S and the correction factor that relates to standard water temperature is here reported as the temperature correlation coefficient θ. The process water temperature in the activated sludge basin T has been directly recorded using the LDO probe. Field Experiments Field tests have been performed at the full-scale WWTP of Eindhoven (Netherlands) which operates according to the UCT configuration (Figure ) with pre-settling. The full-scale Eindhoven WWTP treats the wastewater of 7 inhabitant equivalent (IE) with a load of 136 g COD day -1 IE -1 through the use of three parallel lines, each consisting of a primary settler, a biological tank and four secondary settlers. The pre-settled wastewater enters the biological tank in the central anaerobic compartment (i.e. Inner Ring in Figure ) which is a plug flow reactor with four compartments in series. After the last compartment, the mixed liquor enters the anoxic ring (Middle Ring in Figure ) and then to the outer ring where the activated sludge is kept in motion by three pair of mixers and aeration is supplied by fine pore membrane plate aerators in a continuous aerobic/anoxic ring. The aerators are divided in two main zones defined as summer package (the larger diffuser grid in Figure ) and winter package (the smaller diffuser grid Figure ). The summer package is constantly in use and controlled by a DO-NH 4 cascade controller while the winter package is activated during particular environmental and/or biological conditions (e.g. low water temperatures, rain events, low biomass activity) in order to enlarge the aerobic zone. Figure shows the location in which aeration efficiency is monitored. Locations were chosen in both radial as tangential direction. Inner Middle Outer Beginning of s. p. End of s. p. Middle of s. p. Figure ATII with hood main sampling locations (blue rectangle) and sub-locations (red circles) on the summer package (s. p.).

RESULTS AND DISCUSSION Experiment A A -days experiment was performed to test the newly built off-gas setup. During the first day the hood was placed in the middle of the summer package. Fairly constant values of OTE, αsote and DO were obtained during the first part of the experiment (Figure 3). It should be noted that the noise in the αsote signal is caused by noise in the DO measurement (due to the bubbles; this cannot be avoided). A sudden activation of feedforward control resulted in a peak of DO up to 8 mg/l. This increased air flow rate had a significant impact on the OTE which dropped by %. 4 3 3 1 1 1:4:48 11:16:48 1:8:48 13:4:48 14::48 16:4:48 1 8 6 4 Figure 3 Results of day 1 of exp. A.: OTE, αsote on left axis (%), DO on right axis (mg/l) The αsote time series did not sag because the correction to zero DO compensates for low oxygen transfer when the driving force (i.e. the difference between DO and DO s ) is low. Air flow rate and incoming flow rate for the same time period are given in Figure 4. AF s. ATII (Nm3/h) Infl ATII (m3/h) 14 1 1 8 6 4 1:4:48 11:16:48 1:8:48 13:4:48 14::48 16:4:48 Figure 4 Summer package air flow (AF s. ATII) and the incoming flow (Infl ATII) for AT II A slightly negative but poor correlation between air flow rate and αsote was found (Figure ), in agreement with literature. The extreme increase in air flow rate due to the feedforward control causes the scatter and poor correlation. During the second day of exp. A (Figure 6), different locations were monitored. The hood was located in the middle of the summer package but was now moved in the radial direction. It should be noted that during these changes, unavoidably the load of the system changed. Hence, the

observations are a combined effect of this. Again, a fairly constant behaviour was found in the morning hours (this is normal since the elevated load from the morning peak enters the plant only late due to a large residence time in the sewer system). When moving the hood radially to the outer part of the ring, a slight decrease in αsote (about 1%) could be observed. When moving the hood to the inner part of the ring, an increase could be observed. The slight decrease in αsote in the next part (when the hood was moved back to the middle of the ring) can be attributed to the increased load entering the plant. This can be observed from the increase in DO and increase in air flow rate due to the cascade controller action (Figure 7). αsote (%) 39 37 3 33 31 9 7 y = 49.67x -.47 R² =.1496 Air Flow rate (Nm 3 /h) Figure Phase plane of Air flow rate and αsote, illustrating the poor correlation 4 4 3 3 1 1 Middle Outer Inner Middle 7::1 9:7:1 1:19:1 11:31:1 1:43:1 13::1 1:7:1 16:19:1 Figure 6 Results of day of exp. A.: OTE, αsote on left axis (%), DO on right axis (mg/l) When plotting αsote versus air flow rate, one can now observe a steeper decreasing trend in the correlation (Figure 8). 4 3 1

AF s. ATII (Nm3/h) Infl ATII (m3/h) 1 8 6 4 7::1 9:7:1 1:19:1 11:31:1 1:43:1 13::1 1:7:1 16:19:1 Figure 7 Air flow rate and influent. αsote [%] 43 41 39 37 3 33 31 9 7 y = 17.64x -.161 R² =.61 Air Flow rate [Nm 3 h -1 ] Figure 8 Phase plane of Air flow rate and αsote during day of experiment A. Experiment B During exp. B, OTE was measured at different locations tangentially along the length of the summer package. Each location (i.e. beginning, middle and end) was monitored at three radial locations (Figure ). The first day the middle of the summer package was monitored, followed by the beginning and the end during the second day. The αsote level was found to be significantly lower at the beginning of the summer package (approx. %) compared to the one obtained in the middle of the summer package (Figure 9). Moving the hood in the radial direction seems to have some impact. However, this coincides with the increase in load and both effects cannot be separated from the data. However, it can be noted that the DO level is almost zero at the outside of the ring, whereas it is higher at the inside of the ring. In the afternoon an increase in DO can be observed resulting from the cascade controller. Again, this results in a decrease in αsote at increasing air flow rate. Unfortunately this cannot be checked due to a lack of air flow data from the SCADA system of the treatment plant during this experimental campaign. Therefore, also the high value of DO registered in the middle of the summer package (Figure 1) cannot be explained in the present work but attention can be given to the αsote behavior which again rises moving the hood in the inner side of the section. Furthermore, although the variability of DO seems to be higher, αsote is practically once again constant from the middle toward the outer location.

4 3 3 1 1 Middle Outer Inner 3. 3. 1. 1. 8:9:36 9:1:36 1:33:36 11:4:36 1:7:36 14:9:36 1:1:36 16:33:36 Figure 9 Results of experiment B (beginning of summer package). OTE, αsote on left axis (%), DO on right axis (mg/l). -. 4 4 3 3 1 1 Middle Outer Inner 8:4: 9:36: 1:48: 1:: 13:1: 14:4: 1:36: 16:48: Figure 1 Results of experiment B (middle of summer package). OTE, αsote on left axis (%), DO on the right axis (mg/l). Moreover, during the measurements at the end of the summer package (Figure 11), a similar αsote behavior from the one in Figure 1 has been recorded but lifted to an higher efficiency level. Again the efficiency from the middle toward the outer locations are practically coincident, rising then, when the hood arrives in the inner part. Indeed from Figure 1, one can see how the efficiencies are higher in the inner part of the measured section validating the fact that lower horizontal velocities correspond to higher efficiencies (Gillot, ). On the other hand, it should be pointed out that inner sub-locations were always visited during afternoon hours when the load reaches its peak and the aeration cascade control system increases the air flow (which also impacts horizontal velocity). Therefore, a decrease in the αsote profile was expected. The results along the length are consistent with an increase in αsote of about 7% for the inner part, 7% for the middle and 3% for the outer location between the beginning and the end of the summer package. The constant value of αsote among the sub-locations at the beginning of the summer package could suggest that the vicinity of the impellers package provides a well mixed environment with well 6 4 3 1

distributed flow velocity. However, towards the end of the aeration system the gap in αsote between sub-location increases, probably due to the fact that the velocity becomes heterogeneous due to inertia effects that occur further away from the mixers. In the outer sections and especially at the end of the summer package the higher velocity leads to a lower efficiency value. The fact that αsote is not rising linearly towards the radial section is probably due to turbulence effects. These findings need to be considered when attempting a more detailed modeling of aeration in the EH WWTP. 6 4 3 1 Middle Outer Inner 8:9:36 9:1:36 1:33:36 11:4:36 1:7:36 14:9:36 1:1:36 16:33:36 Figure 11 Results of experiment B (end of summer package). OTE, αsote on left axis (%), DO on right axis (mg/l). 4 3. 3. 1. 1. 6 4 3.6 (.13) 37.61 (.48) 39.16 (1.7) 36.8 (.7) 31.7 (.9) 31.9 (1.73) 31.17 (.1) 9.84 (.67) 3.39 (1.4) Inner Middle Outer Beginning of s. p. αsote Middle of s. p. αsote End of s. p. αsote Figure 1 Efficiency averaged values and standard deviations for each radial location CONCLUSIONS Oxygen transfer efficiencies were measured at the WWTP of Eindhoven under different circumstances and at different locations in the aerated zone. The main finding was that αsote is not constant along the length of the summer package. Higher values (ca. 38%) were measured towards the end of the aerated zone compared to the beginning of that zone (ca. 3%). Furthermore, homogenous OTE was observed at the start of the aerated zone, whereas heterogeneity can clearly be observed towards the end. This will have to be accounted for in the aeration model of the EH WWTP model. The present activated sludge basin seems to have a plug flow based behavior with respect to oxygen transfer, which might be different from the mixing behavior of other dissolved components.

ACKNOWLEGMENTS The authors wish to acknowledge the support of the technical personnel of the WWTP of Eindhoven. REFERENCES ASCE (1984, 1991, 7) ASCE Standard: Measurement of Oxygen Transfer in Clean Water, New York, NY. ASCE (1997) ASCE Standard: Standard Guidelines for In-Process Oxygen Transfer Testing, New York, NY. Baca, R. G. and Arnett, R. C. (1976) A Limnological Model for Eutrophic Lakes and Impoundments. Battelle Pacific Northwest Laboratories, for USEPA, Office of Research and Development, 18 p. Capela, S., Heduit, A. and Roustan, M. () Influence of the Water Depth on Fine Bubble Aeration efficiency in the Presence of Surfactants, Preprints of the 3 rd IWA World Water Congress, Melbourne, Australia, 7-1 April. Frey, W., Thonhauser, C. (4) Clogging and cleaning of fine pore membrane diffusers, Water Science and Technology (7), 69 77. Gillot, S. and Heduit, A. () Effect of air flow rate on oxygen transfer in an oxidation ditch equipped with fine bubble diffusers and slow speed mixers, Water Research 34(), 176-176. Gillot, S. Capela-Marsal, S., Carrand, G., Wouters-Wasiak, K., Baptiste, P. And Heduit, A. () Fine bubble aeration with EPDM membranes: conclusions from 1 years of practice. Proceedings of the IWA Specialized Conference, Nutrient Management in Wastewater Treatment Processes and Recycle Streams, Krakow, 18-1 September. Gillot, S. and Heduit, A. (8) Prediction of alpha factor values for fine pore aeration systems, Water Science and Technology 7(8), 16-169. Leu, S.-Y., Rosso, D., Larson, L.E., Stenstrom, M.K. (9) - Real-Time Aeration Efficiency Monitoring in the Activated Sludge Process and Methods to Reduce Energy Consumption and Operating Costs, Water Environment Research 81, 471-481. Reardon, D. J. (199) Turning down the power, Civil Engineering, 6(8), 4 6. Metcalf & Eddy, Inc. (3). Wastewater Engineering: Treatment and Reuse - 4th edn. (Tchobanoglous, G., Burton, F.L. and Stensel, H.D. eds.). McGraw-Hill series in civil and environmental engineering, New York. Redmon, D.T., Boyle, W.C., and L. Ewing. L. (1983) Oxygen Transfer Efficiency Measurements in Mixed Liquor Using Off-gas Techniques, Journal of the Water Pollution Control Federation,, 1338. Rosso, D. and Stenstrom, M. K. (6) Surfactant effects on α-factors in aeration systems, Water Research 4, 1397-144. STOWA (9). Handreiking OC-metingen in de praktijk (in Dutch). Rapport 1, STOWA, Utrecht. Wagner, M.; Loock, P. (7) Biological Coating of Membranes of Fine Bubble Diffusers: Impacts and Countermeasures, 8th Annual Water Environment Federation Technical Exhibition and Conference (WEFTEC), October 13-17th 7, San Diego, USA.