Evaluation of natural ventilation systems in a landscaped office.

Similar documents
BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

A field study of the performance of the Dutch Adaptive Temperature Limits guideline

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Theory versus practice of energy and comfort in 4 low energy houses in Belgium

Designing Air-Distribution Systems To Maximize Comfort

FHealthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Introduction to basics of energy efficient building design

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Retrofitting Adaptive Comfort Strategies into Conventionally Air Conditioned Commercial Buildings

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

DESIGN OF A GREEN DEMO BUILDING IN A HOT AND HUMID CITY IN CHINA. Ana Bacall Sebesta Blomberg & Associates Woburn, MA

Experimental investigation of zero energy office under natural and forced ventilation

ENERGY AND THERMAL COMFORT EVALUATION FOR DIFFERENT PASSIVE SOLUTIONS IN A KINDERGARTEN IN SUMMER CONDITIONS.

Bio Climatic Analysis of Bhubaneswar-An Investigation to Arrive Human Comfort through Natural Ventilation

Deakin Research Online

Thermal Comfort in Architecture

Bio-climatic Chart for Different Climatic Zones of Northeast India

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

Ventilative Cooling potential tool

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

Work Package 2: Performance of naturally ventilated buildings

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

Earth, Wind & Fire Natural Airconditioning [1] Research objectives and Methods

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Indoor climate design for a monumental building with periodic high indoor moisture loads.

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

COMPUTATIONAL ASSESSMENT OF COOLING WITH LOW-TEMPERATURE HEATING SYSTEMS

Case study the Vela Roof UNIPOL, Bologna Use of on-site climate and energy resources

The Centre for Sustainable Building (ZUB) * A Case Study

MODELLING THE ENERGY PERFORMANCE OF NIGHT-TIME VENTILATION USING THE QUASI-STEADY STATE CALCULATION METHOD

AIC TECH 2015 Sustainability in Practice Turning Ideas into Reality Jan 16, 2015 FUTURE & NET ZERO BUILDINGS

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

MODELLING BUOYANCY INDUCED FLOWS OF PASSIVE COOLING SYSTEMS Pedro Correia da Silva 1, Vítor Leal 1 and J. Correia da Silva 2

ENERGY EFFICIENCY IN BUILDINGS AND COMMUNITIES

IMPLICATIONS OF CLIMATE CHANGE AND OCCUPANT BEHAVIOUR ON FUTURE ENERGY DEMAND IN A ZERO CARBON HOUSE

Designing carbon neutral schools: The Victor Miller Building, a critical review

Bioclimatic approaches of modern residential architecture in Cyprus,

LOCAL VENTILATION SYSTEMS: SOME INVESTIGATIONS ABOUT COMFORT LEVELS AND ENERGY DEMANDS

7S9X0 - Week 5 Uncertainties in building performance simulation

AIRCOOL VENTILATORS FURTHER INFORMATION

681: Environmentally Responsive Architecture; Passive Design for School in Southern India

DISPLACEMENT VENTILATION

Passive house optimization for Southern Italy based on the New Passivhaus Standard

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Indoor Air Quality and Thermal Environment in Classrooms with Different Ventilation Systems

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

External Environment and Indoor Microclimate

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

The optimization of the mechanical night cooling system in the office building

Solar and Internal Gains in Low-Energy and Passive Houses

Thermal insulation of buildings and cooling demand

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Daylight, Solar Gains and Overheating Studies in a Glazed Office Building

NEW FOUR STORY MEDICAL CENTER OWNER S PROJECT REQUIREMENTS

125BEPM - Building energy performance modeling. Lecture handouts

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1

Great Ocean Rd Ice Creamery

A Field Study of the Thermal Environment in Residential Buildings in Harbin

Thermal comfort in a 21st century climate

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Modeling the Brillhart House

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Available online at ScienceDirect. Energy Procedia 78 (2015 )

INDOOR AIR QUALITY IN CLASSROOMS: FIELD CAMPAIGN BY QUESTIONNAIRES AND MEASUREMENTS S. P. Corgnati and S. Viazzo

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

AIR QUALITY IN COW HOUSES WITH CURTAIN WALL VENTILATION IN FINNISH CLIMATE

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

Case Study: Bio-Climatic Building Design for Tropical Climates

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

Closed Greenhouse: a Starting Point for Sustainable Entrepreneurship in Horticulture

Comparison of the Intensity of Ventilation at Windows Exchange in the Room - Case Study

Thermal Comfort Evaluation of HDB flats

Thermal comfort conditions in outdoor spaces

Thermal Delight in Architecture

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

Impact of Building by-laws on microclimatic elements of residential building layouts. Case Nagpur

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

Optimizing a cooling water outfall inside the Maasvlakte 2 port extension - dealing with conflicting requirements

Natural Ventilation Approached on Circular Courtyard Building in Hot Humid Climate

CONCENTRATION OF CARBON DIOXIDE MEASURED IN UNIVERSITY CLASSROOMS

Passive Houses in South West Europe

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

LEED v4 Building Design and Construction Quiz #8 EQ

DPR Phoenix Regional Office Net Zero Certification

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Transcription:

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 1 of 6 Evaluation of natural ventilation systems in a landscaped office. Hilde Breesch 1, Kristof Descheermaeker 2, Arnold Janssens 1, Lieven Willems 1 1 Dept. of Architecture and Urban Planning, Ghent University, Ghent, Belgium 2 Department of Architecture, VUB, Brussels, Belgium ABSTRACT: The Renson office building (Waregem, Belgium) relies on natural ventilation for both indoor air quality and temperature control. Indoor air quality control is provided by a system consisting of self-regulating inlet vents and passive stack exhausts. Temperature control in summer is achieved by a system for natural night ventilation with motorized inlet and outlet windows. The indoor air quality and thermal comfort in the offices is evaluated on the basis of long-term measurements of relative humidity, CO 2 and internal temperatures and discussed in the paper. Conference Topic: 5 Materials and building techniques Keywords: Natural ventilation, night ventilation, IAQ, thermal comfort 1. INTRODUCTION 1.1 Building description The low-energy office building of Renson, a company that develops and manufactures natural ventilation and solar shading systems, is located in Waregem (Belgium) in between the manufacture plant and the highway. The office is designed to demonstrate the so-called healthy building concept, which relies on natural ventilation and solar shading to achieve indoor air quality and temperature control with limited energy consumption (no air circulation and refrigeration equipment). All offices are located on the second floor on top of a limited ground and first floor with building services. The office floor is supported by 6m high columns, in order to hide the production plant from view. The façade is almost completely glazed. Properties of the insulating glass and other thermal building data are shown in table I. The floor consists of a raised (false) floor system. Figures 1 and 2 show a plan of the second floor and a vertical section. The office floor consists of an open plan office (n 1), oriented to the north, surrounded by small offices on the south-west side (n 2 and 3), internal (n 4) and external (n 5) meeting rooms on the south-east and north-east side and lunch rooms (n 6). With exception of the external meeting rooms (n 5), which are mechanically ventilated, all other rooms are naturally ventilated. 1.2 Concept natural ventilation and passive cooling The natural ventilation system for indoor air quality control consists of acoustic self-regulating inlet grills and passive stack exhausts. The inlet grills are located at the bottom of the curtain wall over the full length of the façade (see Figure 3). In winter the supply air is heated by the underfloor convector heating system. Table I: Thermal building data. window NO (n 6) NO(n 5) NW ZW A glass (m²) 75 25 3 225 g (-),61,61,53,53 U (W/m²K) 1,3 1,3 1,3 1,3 LTA (-),76,76,74,74 Sun blades no no no yes floor roof U (W/m²K).5.3 A (m²) 233 233 V (m³) 8388 6 m 1 m 2 m 4 1 5 3 2 Figure 1: plan of second floor with landscape office (n 1), accounting and management section (n 2), reception desk (n 3), internal (n 4) and external (n 5) conference rooms and service rooms (n 6) 4 m 1 1 m Figure 2: vertical section through landscape office (n 1) and internal conference rooms (n 4)

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 2 of 6 Figure 3: Inlet grill and window for natural day and night ventilation at the bottom of the curtain wall. Figure 4: Operation of natural night ventilation. Table II: Internal heat gains with actual and design occupation in some office rooms. Office equipment landscape (n 1) Accounts 1 (n 2) Accounts 2 (n 2) Reception (n 3) Area (m²) 992 63 37 35 People actual 5 4 2 2 design 85 4 2 2 PC + monitor p.p. 1 1 1 1 Printers 5 2 2 - Fax 2 - - 1 Copiers 2 - - - Lighting (W/m²) 8 8 8 8 Heat actual 15.4 22.7 23.2 18.2 gains (W/m²) design 21. 22.7 23.2 18.2 Table III: Internal heat gains of people, office equipment and lighting [1]. Heat gains diversity n 1 n 2 & 3 people 8 W/pers..75 1 PC + screen 13 W/pc..75 1 Laser desk 215 W/pc. -.5 printer office 32 W/pc..5 - Fax machine 15 W/pc..5 Copier 11 W/pc..3 lighting 8 W/m².75 The extraction openings are located in 15 individual chimneys on top of the building, at a height of 7.5 m above the inlet grills. The natural night ventilation system for temperature control consists of motorised inlet and outlet windows, located at the bottom of the curtain walls and in the chimneys (Figure 3 and 4). The area of inlet and outlet openings is 2% and 1% of total floor area. They are designed to reach a mean ventilation flow at night of 6 ach. This airflow allows to cool down the exposed concrete ceiling of the office floor (625 kg/m² thermal mass). Both inlet and outlet windows are automatically controlled in response to the control algorithm for night ventilation. The occupants may also individually control the inlet windows if additional airing is desired. In the chimney two windows at opposing sides are present. Depending on wind direction, the window on the leeward side will be automatically opened. The outlet windows also serve a daylighting function (sky lights). A prerequisite for the feasibility of any night ventilation system for temperature control is a reduced cooling load in the building. The following measures contribute to this: automated external sun blades at the south-west side, energy-efficient lighting and office equipment, a well-insulated roof (Table I) and accessible thermal inertia of the concrete office ceilings. Table II and III report internal heat gains of some interesting rooms. In the actual occupation there is a medium level of internal heat gains in the open plan office and the reception desk and a high level of internal heat gains in the accounting offices. For this reason the accounting offices (as well as the external meeting rooms) are the only rooms where an additional cooling system is installed: an overhead fan-coil unit integrated in a false ceiling. In order to evaluate the performance and operation of the natural ventilation systems, continuous measurements of temperatures in summer 23 were taken from the Building Management System (BMS) and analysed. This analysis is the basis to evaluate thermal comfort during summer in the building. In addition to the measurements performed by the BMS, measurements of relative humidity and carbon dioxide were performed in the landscaped office in winter 24. These measurements are used to evaluate indoor air quality during the heating season. 2. HEATING SEASON 2.1 Indoor climate measurements In February and March 24, a measuring campaign was conducted to evaluate the indoor air quality in the landscaped office during wintertime. The inside temperature, relative humidity and carbon dioxide concentration were measured below the chimneys at two opposing sides of the landscaped office. Carbon dioxide concentration was further measured in a convector pit in the vicinity of an inlet grill. Finally the registration of outside temperature and relative humidity took place at a shaded location near the building. All parameters were continuously monitored and stored at 1 -intervals. The measuring results are illustrated in Table IV and Figure 5. Table IV shows the deciles and medians of the measured values during working hours. The CO 2 -measurement in the convector pit

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 3 of 6 was assumed to be representative for the outside concentration. As a result of intensive traffic on the nearby highway, this concentration fluctuated with peaks in the morning and early evening. Table IV: Statistics of indoor climate measurements during working hours (9:-17:), Feb-Mar 24. Outside Inside θ RH CO 2 θ RH CO 2 C % ppm C % ppm 1% 2.5 54 365 21.7 22 52 5% 6.6 75 41 22.1 26 59 9% 13.8 88 5 22.5 43 69 Perc Concentration CO2 (ppm) 7 6 5 4 3 1-mrt 2-mrt 3-mrt 4-mrt 5-mrt outside inside1 inside2 Figure 5: Measured carbon dioxide concentrations. CO2-difference (ppm) CO2-difference (ppm) 4 3 2 1 4 3 2 1 1 Outside temperature ( C) 2 4 Wind speed (m/s) C = 247 + 7.7 θe 13.4 v (r² =.47) Figure 6: Relation between the daily maximum inside-outside difference of CO 2 -concentration and the mean outside temperature (above) and the wind speed (below). As Figure 5 shows, during occupation time (9:- 17:) the indoor concentrations increase to a steady 6 level roughly 25 to 3 ppm above the outside concentration. For comparison, most indoor air quality standards consider a difference of 12 ppm between inside and outside to be acceptable [2]. Thus the small measured difference between inside and outside concentration is an indication that the outside ventilation rate per occupant is higher than necessary. This observation is confirmed by the relative humidity measurements. The relative humidity in the landscaped office was found to be smaller than 3% during more than 5% of occupation time. Logically, the lowest values occurred during cold weather. These low values measured in the office may cause complaints of discomfort due to dryness. In order to meet the lower indoor air quality criterion of 3% RH [2], the ventilation rate per occupant should be reduced. This measure may also reduce energy consumption for heating. 2.2 Parameter analysis As a first indication of the performance of the ventilation system, the relation has been investigated between the indoor air quality and the driving forces for natural ventilation. The daily maximum inside-out side difference of CO 2 -concentration is used as an indicator for IAQ. Figure 6 shows the results of the analysis. The concentration difference appears to be remarkably constant: its value remains at a low level, even when outside temperature is high and wind speed is low. This might be the result of interzonal air flow (mixing) between the office and adjacent unoccupied spaces like the lobby and lunch room. The relation between the CO 2 -concentration difference and driving forces is not very strong: the coefficient of determination for the multiple regression analysis is smaller than.5. There is a slightly positive correlation with the mean outside temperature during occupation time, and a slightly negative correlation with the average wind speed (provided by the BMS). Still the analysis indicates that although the ventilation system has been designed as a thermal stack driven (chimney) system, wind plays an equally important role in the effective ventilation performance. This might explain the unexpectedly low measured values of relative humidity and CO 2 - concentration in the office. The daily measured exponential decay of the inside-outside concentration-difference has been used to quantify the air change rate in the office (concentration-decay method). The air change rate resulting from this analysis was in the order of.8 ach, or approximately 6 m 3 /h per occupant. In a further step of the research a ventilation model will be applied to confront the experimental with calculation results, and to analyse different measures to improve the performance of the ventilation system. 3. COOLING SEASON [3] 3.1 Natural night ventilation operation The controls of the night ventilation system are set as follows. The system operates generally from 9 p.m. till 7 a.m. The operation time may be extended in

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 4 of 6 extremely warm summer periods. The operation of natural night ventilation further depends on the maximum inside and outside air temperature of the previous day (θ i,a,max > 23 C and θ e,a,max > 22 C), on inside air temperature (θ i,a > 2 C) and relative humidity (R.V. i < 7%), wind speed during rain (no wind) and wind speed for storm (v < 5 km/h). When these conditions are fulfilled, the inlet and outlet windows are opened automatically to allow an increased ventilation rate. The monitoring of the effective performance of the system showed that the system was in operation every night between May 28 and August 27 and 8 days during the second half of September. Control parameters were fine-tuned in this period. Figure 7 shows temperatures, relative humidity and operation of ventilation openings during the first week of a heat wave in August. Highest relative humidity (between 6 and 7%) and lowest temperatures occurred in the morning. Inlet windows were generally opened during the whole night. Outlet windows were separately controlled and opened and closed several times a night. The performance of the system for night ventilation has been analysed based on the achieved temperature drop overnight (between 9 p.m. and 8 a.m. the next day). Figure 8 shows the temperature drop in the landscaped office as a function of the mean indoor and outdoor temperature difference during night (from 9 p.m. till 8 a.m.). Temperature ( C) 45 4 35 3 25 2 15 1 1-8-3 2-8-3 3-8-3 indoor temperature night ventilation (in) relative humidity 4-8-3 5-8-3 6-8-3 7 6 5 4 3 2 1 outdoor temperature night ventilation (out) Relative Humidity (%) Figure 7: Measured indoor and outdoor temperature, indoor relative humidity and operation of ventilation openings during a heat wave. Temperature drop ( C) 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 T inside-outside ( C) Figure 8: Temperature drop in the landscaped office hardly depends on temperature difference inside - outside. Table V: Temperature drop overnight in landscaped, reception and accountancy offices Temperature drop Mean ( C) Standard deviation ( C) Landscape 4.1 1. Reception 2.9 1.2 accountants 3. 1.2 Similar results are noticed for reception and accouncy offices. The average temperature drop in the landscaped office was 4.1 C, it varied between 3.1 and 5.1 C with a probability of 68%. As Table V shows, the temperature drop in the reception and accountancy offices was 1 C smaller, with variations in the same order as in the landscaped office. The mean indoor-outdoor temperature difference during night was minimally 3 C and 2 C with a probability of.95 in respectively the open plan office and the reception and accountancy offices when night ventilation was in operation. 3.2 Thermal comfort evaluation This paragraph will discuss and compare the thermal comfort measured in the open plan office, in the reception desk and the accountancy office. The latter office is the only one provided with a mechanical cooling system. cumulative frequency (%) 1 9 8 7 6 5 4 3 2 1 TRY Uccle Renson 23 12 14 16 18 2 22 24 26 Daily average temperature ( C) Figure 9: Comparison cumulative daily average outside temperature distributions on site vs Test Reference Year (TRY) Uccle (Belgium). Measurements from May to September 23 are used in the analysis. According to the Royal meteorological institute of Belgium (RMI) this period (summer 23) was extremely warm and sunny [4]. Normal mean outside temperature was exceeded nearly every day. Furthermore during the first two weeks of August a heat wave occurred: temperature peaks of more than 37 C were measured on 4 days. Figure 9 compares the statistics of the daily average external temperatures measured on site to the external temperatures of test reference year (TRY) in Uccle, which are normally used in design calculations to assess thermal comfort. The comparison is in agreement with the conclusions of the RMI. Two criteria have been used to evaluate the dynamic thermal comfort: (a) the temperature exceeding hours method [5] and (b) the adaptive boundary temperature indicator (ATG) [7].

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 5 of 6 Fangers' comfort theory [8] is the basis for the method of temperature exceeding hours. The method limits the working hours in which more than 1% of occupants are dissatisfied (i.e. PPD or predicted percentage of dissatisfied people) to a maximum of 5%, or 1 hours a year (based on 2 working hours). The critical indoor operative temperature corresponding to a 1% PPD-requirement, depends on metabolism (activity level) and clothing resistance. Assuming seated office work (metabolism = 65 W/m²) and light working clothes (.7 Clo), a threshold temperature value of 26. C is found [6]. As an additional requirement the time during which more than 25% of occupants may be dissatisfied is limited to 1%, or 2 hours a year. The 25%-requirement corresponds to an indoor operative temperature of 28 C. Figure 1 shows the measured temperature exceeding hours in the open plan, reception and accounting offices. The temperatures in the landscaped office are generally higher than in the other offices because of solar heat gains in the evening: the glazed northwest oriented façade has no sun blades. In the accountancy offices with mechanical cooling the exceeding hours are far reduced compared to the other rooms. In the open plan office daily maximal indoor temperatures occurred in the late afternoon (at 4 or 5 p.m.). In the other offices, with southwest orientation and external solar shading devices, the maximal temperatures were reached during the whole afternoon depending on the actual weather (from 12 a.m. to 5 p.m.). The measured exceeding hours are 69h, 47h and 34h for respectively the open plan office, reception desk and accountancy office. Compared to the performance criterion of 1 exceeding hours above 26 C, the thermal comfort in all offices proves to be acceptable, especially considering the extremely warm and sunny weather on site. However the additional requirement of maximum 2 exceeding hours above 28 C, is not met in the landscaped office. Here 25 exceeding hours were measured, typically occurring during the August heat wave. Considering the exceptional occurrence of such weather, the deviation between requirement and actual performance is quite small. temperature exceedings (h) 175 15 125 1 75 5 25 173 73 69 59 47 39 34 31 25 2 16 9 landscape reception accountants 2 13 4 2 3 25 C 26 C 27 C 28 C 29 C 3 C Figure 1: Temperature exceeding hours in landscape office, reception and accountancy offices. The adaptive boundary temperature indicator (ATG) has been developed in accordance with the adaptive comfort theory of Brager and de Dear [9]. Comfort measurements in naturally ventilated buildings, where occupants are able to open windows and adjust indoor conditions, revealed a stronger relation between the preferred indoor temperature and the prevailing external temperature than Fangers comfort theory may explain [1]. This is caused by behavioural and psychological thermal adaptation. Behavioural adaptation refers to any conscious or unconscious action a person might make to alter their body's thermal balance, including changing clothes, opening windows, etc. Psychological adaptation on the other hand means that the perception of thermal conditions depends on past experiences and expectations. The ATG-method distinguishes between three levels of thermal comfort (see Figure 12 for naturally ventilated buildings) [7]. Level A corresponds to 9% thermal acceptability and is applied in buildings with high performance requirements to thermal comfort. Level B corresponds to 8% thermal acceptability and means good indoor thermal comfort. This is the standard level. Level C finally corresponds to 65% thermal acceptability and is only applied in temporary situations in existing buildings. As derived in the adaptive comfort theory, the minimum and maximum limiting values for indoor temperature on a given day depend on the effective outdoor temperature T e,ref, i.e. the running mean outdoor temperature of the given day and three preceding days with weighting factors in sequence of 1,.8,.4 and.2. During an average summer in northwest Europe, a T e,ref -value of 16 C corresponds to a normal summer period, while T e,ref reaches a maximum value of 22 C corresponding to a warm summer period. Figure 11 and 12 show the measured daily maximum and minimum indoor temperatures during occupancy, compared to the adaptive boundary temperature indicator. The application of the ATGmethod to the measured maximum temperatures, confirms the conclusions of the temperature exceeding method. The observed thermal comfort is good (Level A or B) as long as outdoor temperatures are not abnormally high (T e,ref < 25 C). Only during the August heat wave with running mean outdoor temperatures above 26 C, the acceptability level of 65% is not met in the landscaped office over 3 days. The analysis of the measured minimum temperatures during occupancy reveals a more systematic comfort problem. The operative temperatures occurring at 8 a.m. when occupants arrive are often smaller than the 65%-acceptability limits derived in the ATG-method. This is caused by an inadequate set point in the night ventilation control algorithm that might cause complaints of discomfort. During the measurements, the inside temperature set-point for closing the inlet and outlet windows was set at 2 C in the landscaped office and 19 C in reception and accountancy offices. To solve the problem and achieve a good indoor comfort (level B) this set point should be raised to higher values of 2.5 to 21 C.

Plea24 - The 21 th Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19-22 September 24 Page 6 of 6 indoor temperature ( C) 32 3 28 26 24 22 2 18 12 14 16 18 2 22 24 26 28 T e,ref ( C) max indoor temperature min indoor temperature level A level B level C Figure 11: Adaptive boundary temperature indicator in the landscape office. indoor temperature ( C) 32 3 28 26 24 22 2 18 12 14 16 18 2 22 24 26 28 T e,ref ( C) max indoor temperature level A min indoor temperature level B level C Figure 12: Adaptive boundary temperature indicator in the reception desk. 4. CONCLUSION The Renson office building relies on natural ventilation and solar shading to achieve indoor air quality and temperature control with limited energy consumption (no air circulation and refrigeration equipment). The performance and operation of the natural ventilation systems has been evaluated on the basis of long-term measurements of relative humidity, CO 2 and internal temperatures. Measurements of relative humidity and carbon dioxide during winter 24 showed that ventilation rates per occupant are higher than necessary. As a result humidity in the landscaped office was often too dry. A regression analysis indicated that although the ventilation system was designed as a thermal stack driven (chimney) system, wind played an equally important role in the effective ventilation performance. A modelling analysis is needed to evaluate different measures to improve the performance of the ventilation system. Measurements of temperatures in summer 23 were taken from the Building Management System (BMS) and analysed to evaluate thermal comfort during summer. Comfort assessment has been performed by means of the temperature exceeding hours method and the adaptive boundary temperature indicator. The analysis showed the ability of the natural night ventilation system to achieve good thermal comfort, except when outside weather was exceptionally warm, as during the August heat wave. The analysis further showed the need to raise the night ventilation control set point, in order to prevent too low temperatures in the morning. 5. ACKNOWLEDGEMENT The authors would like to acknowledge the company Renson and in particular dr.ir. Ivan Pollet for the availability of measuring data and their support to additional measurements and research. Also the information on ATG provided by ir. A.C. van der Linden (Technical University Delft) is gratefully acknowledged. REFERENCES [1] P.E. Wilkins, M.H. Hosni, Heat Gain From Office Equipment, Ashrae Journal 42 (2) 6 33-44 [2] CR1752 Ventilation for buildings: design criteria for the indoor environment. [3] K. Descheemaeker. Performance of natural ventilation systems in offices (in Dutch), Master-thesis VUB Brussels (24), 118 pp. [4] Royal Meteorological Institute of Belgium, Climatological overview of 23 (in Dutch or French), http://www.kmi.be [5] Building physical quality: legal requirements and recommendations (in Dutch), Netherlands Ministry of Spatial Planning, Housing and the Environment (1999), http://www.vrom.nl [6] ISSO, Design of indoor conditions and good thermal comfort in buildings (in Dutch), ISSO Research rapport 5, Rotterdam, The Netherlands (199) 58 [7] ISSO, Thermal comfort as performance (in Dutch), ISSO Research rapport 58.2, Rotterdam, The Netherlands (24) 89 [8] P.O. Fanger, Thermal comfort: Analysis and applications in environmental engineering, McGraw- Hill, London, New York (1972) 223 [9] G.S. Brager, R.J. de Dear, A standard for natural ventilation, ASHRAE Journal 42 (2) 12 21-28 [1] G.S. Brager, R.J. de Dear, Developing an adaptive model of thermal comfort and preference, ASHRAE Transactions (1998) 14 (1) 145-167