EXERGETIC ANALYSIS OF SOLAR AIDED COAL FIRED (210MW) THERMAL POWER PLANT

Similar documents
Feedwater Heaters (FWH)

Chapter 8. Vapor Power Systems

Efficiency improvement of steam power plants in Kuwait

Performance Optimization of Steam Power Plant through Energy and Exergy Analysis

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

OPTIMIZATION OF PARAMETERS FOR HEAT RECOVERY STEAM GENERATOR (HRSG) IN COMBINED CYCLE PLANTS

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

Lecture No.3. The Ideal Reheat Rankine Cycle

Consider a simple ideal Rankine cycle with fixed turbine inlet conditions. What is the effect of lowering the condenser pressure on

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

Applied Thermo Fluids-II: (Autumn 2017) Section-A: Thermal Power Plants

Energy And Exergy Analysis Of Fully Condensing Steam Turbine At Various Steam Load Condition

Energy Audit of 250 MW Thermal Power Stations PTPS, Panipat

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 08 Aug p-issn:

Exergy analysis of a flat plate solar collector

Optimization of parameters for heat recovery steam generator (HRSG) in combined cycle power plants

An Approach towards Thermal Power Plants Efficiency Analysis by Use of Exergy Method

CHAPTER 4 STEAM TURBINE and CYCLE HEAT BALANCE

Exergy Analysis of a Power Plant in Abu Dhabi (UAE)

Technical And Economical Aspects Of Thermal Efficiency Of Grate-Fired Waste-To- Energy Plants

Performance Benefits for Organic Rankine Cycles with Flooded Expansion

Secondary Systems: Steam System

Problems 2-9 are worth 2 points each. Circle T or F as appropriate for problems 6-9.

Christian Ohler, ABB Switzerland Corporate Research Efficiency versus Cost - a Fundamental Design Conflict in Energy Science

Thermodynamic analysis on post combustion CO 2 capture of natural gas fired power plant

5. Steam Turbine Performance

CHAPTER 2 POWER PLANT THERMODYNAMICS

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Chapters 5, 6, and 7. Use T 0 = 20 C and p 0 = 100 kpa and constant specific heats unless otherwise noted. Note also that 1 bar = 100 kpa.

CONTROL VOLUME ANALYSIS USING ENERGY. By Ertanto Vetra

Available online at ScienceDirect. Energy Procedia 49 (2014 ) SolarPACES 2013

Exergy in Processes. Flows and Destruction of Exergy

Combined cycle with detailed calculation of Cp in the HRSG

Performance of a Gas Turbine Power Plant

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Liquid-Flooded Ericsson Power Cycle

Michigan State University DEPARTMENT OF CHEMICAL ENGINEERING AND MATERIALS SCIENCE. ChE 321: Thermodynamics Spring 2017

Exergy Based Analysis of an Open Cycle Gas Turbine Power Plant

MCG THERMODYNAMICS II. 22 April 2008 Page 1 of 7 Prof. W. Hallett

Kalex Kalina Cycle Power Systems For Use as a Bottoming Cycle for Combined Cycle Applications

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online):

Thermal Performance of Reheat, Regenerative, Inter Cooled Gas Turbine Cycle

Module 2: Conventional Power Generation I

EXERGOECONOMIC ANALYSIS OF A POWER PLANT IN ABU DHABI. Ahmed Nabil Al Ansi, Mubarak Salem Ballaith, Hassan Ali Al Kaabi, Advisor: Zin Eddine Dadach

OPTIMIZATION OF THE TRIPLE-PRESSURE COMBINED CYCLE POWER PLANT. Muammer ALUS and Milan V. PETROVI] *

Thermodynamic Modeling of Binary Cycles Looking for Best Case Scenarios

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Steam balance optimisation strategies

Conventional water/steam cycle

2291-6A. Joint ICTP-IAEA Course on Science and Technology of Supercritical Water Cooled Reactors. 27 June - 1 July, 2011

Exergetic, Exergoeconomic and Exergoenvironmental Analysis of Intercooled Gas Turbine Engine

PERFORMANCE ANALYSIS OF ORGANIC RANKINE CYCLES USING DIFFERENT WORKING FLUIDS

Chapter Two. The Rankine cycle. Prepared by Dr. Shatha Ammourah

Estimation of Steam Production in a Receiver. Under Solar Concentrating Radiation

Thermodynamic and Thermo Economic Optimization of Combined Cycle Power Plant

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

ORGANIC RANKINE CYCLE AS EFFICIENT ALTERNATIVE TO STEAM CYCLE FOR SMALL SCALE POWER GENERATION

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

Energy and Exergy Analysis of M.P.C Absorption Chiller

KEPCO KEPRI Kim eui hwan

Thermodynamic evaluation of the Kalina split-cycle concepts for waste heat recovery applications


Design Optimisation of the Graz Cycle Prototype Plant

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

Thermodynamic analysis of a regenerative gas turbine cogeneration plant

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

In this lecture... Solve problems related to First law of thermodynamics for closed and open systems Heat engines Refrigerators and heat pumps

Power Block Technology for CSP

COMPARATIVE ANALYSIS OF HEAT BALANCES FOR K AND 13 CK 240 TURBINES

Energy Analysis of Supercritical Water and Ammonia (Kalina) Power Cycle

To Study of Maximum Efficiency Of Power Generation in Thermal Power Plant

A Trans-critical CO2 Heat Pump System for Waste Heat Utilization in Warm Weather Condition Applied to a Milk Refrigeration Plant

Advanced Thermal Energy Storing with the most efficient use of the ressources. Peter Badstue Jensen Vice President - Partner

Potential For Local Manufacturing of Solar Thermal Systems in Egypt

Article Thermodynamic Analysis of Three Compressed Air Energy Storage Systems: Conventional, Adiabatic, and Hydrogen-Fueled

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Handal, Alvarenga, Recinos GRC Transactions. Volume

Comparison of micro gas turbine heat recovery systems using ORC and trans-critical CO 2 cycle focusing on off-design performance

Performance and Emission Characteristics of Natural Gas Combined Cycle Power Generation System with Steam Injection and Oxyfuel Combustion

Theoretical Investigation on the Partial Load Feedwater Heating System with Thermal Vapor Compressor in a Coal-fired Power Unit

Categorizing Units Based on Controllable Loss Parameters using PEPSE θ

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

St.MARTIN S ENGINEERING COLLEGE Dhulapally,Secunderabad,

Solar-Geothermal Hybrid Cycle Analysis for Low Enthalpy Solar and Geothermal Resources

Exergy Analysis of Absorption Power Cycle Depending on Source Temperatures

EXERGY AND ENERGY ANALYSIS OF 250 MW COAL BASED THERMAL POWER PLANT AT DIFFERENT LOADS

Honeywell Refrigerants Improving the Uptake of Heat Recovery Technologies 1

The Effect of the Condenser Inlet Cooling Water Temperature on the Combined Cycle Power Plant Performance

Fundamental Investigation Of Whole-Life Power Plant Performance For Enhanced Geothermal Systems

II. SYSTEM DESCRIPTION AND MATHEMATICAL MODELING

Exergoeconomic Analysis of A 100MW Unit GE Frame 9 Gas Turbine Plant in Ughelli, Nigeria.

Evaluation of efficiency and collector time constant of a solar flat plate collector

OPERATING PARAMETERS Reliable Means to Continuously Monitor Facility Performance

A THERMODYNAMIC COMPARISON OF THE OXY-FUEL POWER CYCLES WATER-CYCLE, GRAZ-CYCLE AND MATIANT-CYCLE

SOLAR THERMAL INDUSTRIAL PROCESS HEATING FOR CO 2 ABATEMENT: A CASE STUDY

4.1 Introduction 4.2 Kiln System. 4.3 Kiln System Analysis 4.4 Results and Discussion 4.5 Conclusion

OPTIMUM ECONOMY AND EFFICIENCY IN ENERGY CONSUMPTION DURING START-UP AND SHUT-DOWN OF 210MW THERMAL POWER STATIONS

ES Fluid & Thermal Systems Page 1 of 6 STEAM TURBINE LABORATORY

Transcription:

International Journal of Advances in Thermal Sciences and Engineering Volume 2 Number 2 July-December 2011, pp. 85-90 EXERGETIC ANALYSIS OF SOLAR AIDED COAL FIRED (210MW) THERMAL POWER PLANT V. Siva Reddy *#, S. C. Kaushik *, S. K. Tyagi ** ABSTRACT: This article deals with comparative energetic and exergetic analysis for evaluation of coal fired thermal power plant and solar thermal aided coal fired thermal power plant. In this analysis assuming 8h/day solar energy is available, remaining 16 hrs, SAFWH can be supplied by solar thermal storage for 8hr duration. An instantaneous increase in power generation capacity of about 35% is observed by substituting turbine bleed streams to all the low pressure and high pressure feedwater heaters with SAFWH. Coal consumption 3.5% is increased for reheat of the steam by replacement of high pressure feed water heaters with SAFWH. Energetic efficiencies of solar aided coal fired thermal power plant appear high as compared to solar alone thermal power plant and low as compared to coal fired thermal power plants. Furthermore, for a SAFWH, it is found that the land area requirement is 3.3 hectare /MW for large scale solar thermal storage system running the plant for 24hrs. Keywords: Thermal power plant, Energetic efficiency, Exergetic efficiency, Solar aided feed water heating, Linear Fresnel Reflecting Solar Concentrator. 1. INTRODUCTION The total power generation capacity of India is 167077.36 MW. On that coal fired thermal power plant have the generation capacity of 89778.38MW, and major domination of total power generation [1]. But fossil fuels scarcity and global warming problems associated with the power plant exhaust (CO 2 ), it is desired that solar energy utilization in the power plant is one preferable option to fulfill the system demand. The exergy method of analysis is based on the second law of thermodynamics and the concept of irreversible production of entropy. The exergetic performance analysis not only determines magnitudes, location and causes of irreversibilities in the plants, but also provides more meaningful assessment of plant individual components efficiency [2]. Gupta and Kaushik [3] have carried out a case study of a typical 50kW solar thermal power plant and a 220MW coal fired thermal power plant. Reddy et. al [4], analyzed the solar concentrator aided coal-fired power plants to establish their techno-economic viability of subcritical and supercritical power generation in India. Negi et. al [5] presented optical designs and performance characteristics of a Linear Fresnel Reflector Solar Concentrator (LFRC) with a flat vertical absorber by two different approaches with a variation in the width and equal width of the constituent mirror elements. The present work has been undertaken for exergetic analysis of a Solar aided coal fired (210MW) thermal power plant using LFRSC. 2. DESCRIPTION OF COAL FIRED THERMAL POWER PLANT Detailed flow diagram of coal fired thermal power plant is shown in Figure 1. The symbols identifying the streams and state point properties are described in Table 1 & process descriptions for each component is summarized. The boiler of the case-study power plant produces 191.6 kg/s of live steam at 149 bar and 811K. There is a single reheat at 811K. A continuous mass flow diagram of the power plant modeled in * Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India, ( # Corresponding author: vundelaap@gmail.com) ** Sardar Swaran Singh National Institute of Renewable Energy, Jalandhar-Kapurthala Road, Wadala Kalan, Kapurthala-144601 (Punjab) India.

86 International Journal of Advances in Thermal Sciences and Engineering this study includes the main components such as high, intermediate and low pressure turbines (HPT, IPT and LPT), a boiler, condensate extract pump (CEP), Boiler feed water pump (BFP), a dearetor, a generator (G), a condenser (C), low and high pressure feed water heaters (LPH and HPH). 3. EXERGETIC ANALYSIS In an open flow system there are three types of energy transfer across the control surface namely work transfer, heat transfer, and energy associated with mass transfer and/or flow energy. The first law of thermodynamics or energy conservation equation for the steady flow process of an open system is given by: 2 2 ci co Σ Qk + m hi + + gzi = m ho + + gzo + W 2 2 Where Q k heat transfer to system from source at temperature T k, and W is the net work developed by the system. The other notations C is the bulk velocity of the working fluid, Z, is the altitude of the stream above the sea level, g is the specific gravitational force. The Energetic efficiency η I of a system and/or system component is defined as the ratio of energy output to the energy input to system/ component i.e. Desired output energy η I = Input engery supplied Exergy is a generic term that defines the maximum possible work potential of a system from a stream of matter and/or heat interaction; with respect to the state of the environment being used as the datum state. The Exergy (Ψ Q ) of heat transfer (Q) from the control surface at temperature (T) is determined from maximum rate of conversion of thermal energy to work W max. is given by: To Ψ Q = Wmax = Q 1 T Exergy of steady flow stream of matter is the sum of kinetic, potential and physical exergy. The kinetic and potential energy are almost equivalent to exergy. The physical specific exergy Ψ i and Ψ o depends on initial state of matter and environmental state. Exergetic analysis is a method that uses the conservation of mass and degradation of the quality of energy along with the entropy generation in the analysis design and improvement of energy systems. Exergetic analysis is a useful method; to complement but not to replace energy analysis. The exergy flow for steady flow process of an open system is given by T Σ 1 o Q k + Σin m Ψ i = Ψ W + Σout m Ψ o + I Tk 2 0 C h = h + + gz 2 I = T S o gen 0 0 ( 0 ) o ( o ) Ψ = m h h T s s

Exergetic Analysis of Solar Aided Coal Fired (210MW) Thermal Power Plant 87 Figure 1: Simplified Schematic View of the Coal Fired Thermal Power Plant Where Ψ i and Ψ o are exergy associated with mass inflow and outflows are respectively, Ψ W is useful work done on/by system, I is irreversibility of process and h 0 is the methalpy as summation of specific enthalpy, kinetic energy and potential energy. The exergetic or second law efficiency is defined as Actual thermal efficiency Exergy output Exergy loss η II = = = 1 maximum possible () reversible thermalefficiency Exergy input Exergy input 4. RESULTS AND DISCUSSION OF COAL FIRED THERMAL POWER PLANT The following parameters have been used during the coal fired thermal power plant analysis: Atmospheric condition is taken as 299K and 1.0 bar, 20% excess air for complete combustion, inlet condition for highpressure steam turbine is taken as 137 bar and 812K, condenser pressure is assumed to be 0.08 bar, heat rejection in the condenser is treated as a energy loss, and generator efficiency is 98%. A computational model was developed for carrying out the energetic and exergetic analysis of the system using Engineering Equation Solver (EES) software [7]. M ass flow, enthalpy and entropy, exergetic power and energetic power of water/steam at each thermodynamic state point are represented in Figure 1 corresponding to design conditions of coal fired thermal power plant as shown in Table 1. Boiler has large difference in exergetic power input and outputs as compared to energetic power input and output. Exergetic power input and output in boiler are 648104 kw and 258510 kw respectively. Energetic power input and output in boiler are 612218 kw and 488094 kw respectively. Energetic and exergetic power losses of different components in the power plant have been shown in Figure 2. Among the all components boiler have major exergetic power loss 389594 kw as compared to energetic power loss 124124 kw. In condenser energetic power loss is high 257399 kw as compared to the exergetic power loss 13847 kw. But in the turbines and pumps energetic and exergetic power losses are negligible. In regenerative heat exchangers (HPH1, HPH2 LPH1, LPH2 and LPH3) have exergetic power loss. Fig. 3. shows energetic and exergetic efficiency of coal fired thermal power plant. Among the all heat transfer components, exergetic efficiency is lower than the energetic efficiency. In electric power generation

88 International Journal of Advances in Thermal Sciences and Engineering Table 1 Stream Data for 210 MW Steam Power Cycle (At Turbine Inlet Pressure 150bar and 812K) S. ID Fluid Mass Tempe- Pressure Sp. Sp. Energetic Exergetic flow rature (bar) Enthalpy Entropy power Power (kg/s) (K) (kj/kg ) (kj/kg K) (kw) (kw) 1 steam 191.6 811 149 3417 6.484 654611 283981 2 steam 20.94 705 75.16 3203 6.529 67712 26929 3 steam 13.67 602 34.11 3055 6.588 41749 14880 4 steam 157 273 34.11 3055 6.588 479463 170890 5 steam 157 811 30.1 3542 7.34 555959 212084 6 steam 9.373 702 14.48 3294 7.378 31115 10476 7 steam 9.315 590 6 3044 7.431 28838 8178 8 steam 8.318 476 2.03 2797 7.512 23920 5270 9 steam 8.807 372 0.57 2577 7.621 23587 3553 10 steam 121.1 315 0.08 2300 7.755 294485 14055 11 water 147.6 273 0.08 175.8 0.5985 25939 253.2 12 water 147.6 315 14.48 177.5 0.6001 26225 471.2 13 water 147.6 355 14.48 345.9 1.102 51045 3127 14 water 147.6 391 14.48 496.9 1.507 73335 7547 15 water 147.6 429 14.48 659.6 1.904 97352 14045 16 water 191.6 468 14.48 827.7 2.279 158553 28932 17 water 191.6 472 195.2 854.2 2.291 163638 33307 18 water 191.6 511 195.2 1030 2.649 197309 46475 19 water 191.6 561 195.2 1269 3.094 243013 66665 20 water 20.94 516 75.16 1051 2.719 22008 5084 21 water 20.94 514 34.11 1051 2.728 22008 5025 22 water 34.6 477 34.11 869.5 2.362 30085 5805 23 water 34.6 470 14.48 869.5 2.367 30085 5752 24 water 9.315 396 6 517.5 1.562 4821 516.1 25 water 9.315 394 2.03 517.5 1.563 4821 513 26 water 17.63 360 2.026 365.9 1.162 6451 412.5 27 water 17.63 358 0.57 365.9 1.162 6451 409.8 28 water 26.44 320 0.57 197.4 0.6664 5219 79.91 29 water 26.44 315 0.08 197.4 0.6671 5219 74.33 and consuming components, exergetic efficiency is higher than the energetic efficiency. Over all plant energetic efficiency is 34.19% and exergetic efficiency is 31.81%. It is evident from exergetic analysis that major exergetic power loss is in the boiler. So increasing the capacity of thermal power plant by increasing fuel input itself is inefficient. Further analysis has been done upon exergetic analysis of solar aided feedwater heating system 4. RESULTS AND DISCUSSION OF SOLAR (LFRSC) AIDED COAL FIRED THERMAL POWER PLANT The coal fired thermal power plants with feed water cycle consists of two series of heaters as LP & HP Heaters (Figure 1). From the energy conservation point of view, the solar concentrator aided feed water heating process in existing power plant can be accomplished by replacing both LPH and HPH heaters

p o w e r p l a n t w e r e : A v e r a g e s o l a r b e a m r a d i a t i o n o f 4 0 0 W / m Exergetic Analysis of Solar Aided Coal Fired (210MW) Thermal Power Plant 89 Figure 2: Energetic and Exergetic Power Loss in Coal Fired Thermal Power Plant Components with SAFWH. The non-extracted steam will expand in the respective turbine stages and finally will be exhausted to the condenser. The following fixed parameters are considered for the analysis. Width and length of the Linear Fresnel Reflector Solar Concentrator (LFRSC) glass is 0.5m & 500m and focal distance is 14m, total number of reflectors in single LFRSC is 40, concentration ratio is 48; average mass flow rate (m f ) is 22.06 kg/s, Therminol VP-1 as the heat transfer fluid. Assumptions made to design the solar aided coal fired thermal 2 available in 8 hr/day. Remaining 16 hr backup from solar thermal storage facility. The results indicate that replacement of LPH and HPH by SAFWH can gives the exergetic efficiency more than the coal fired thermal power plant. Table 2 shows a summary of the results. In HPH and LPH replacement by SAFWH, the extra output is 74635kW with the solar thermal power input of 243463 kw. Total power plant energetic efficiency is 32.47% and exergetic Figure 3: Energetic and Exergetic Efficiency in Coal Fired Thermal Power Plant Components

90 International Journal of Advances in Thermal Sciences and Engineering efficiency is 35.73%. The land area required for 24hr operation of solar thermal power input is around 244 hectare. Solar aided exergetic efficiency is found to increase from 32.47% to 35.73%, while energetic efficiency is decreased from 34.19% to 31.81%, because the solar thermal conversion efficiency is high (65.52%). Table 2 Various Results of Solar Aided Feed Water Heating Options in Coal Fired Thermal Power Plant Solar aided Feedwater heating options Without Solar Aided With Solar Aided Key parameters Energetic Exergetic Energetic Exergetic Solar heat input (kw) 0 0 243463 126227 Net fuel power input (kw) 612218 648104 633281 670402 Condensate extract pump(cep) (kw) 285.8 285.8 310.07 310.07 Boiler feed water pump(bfp) (kw) 5085 5085 5085 5085 High pressure turbine(hpt) (KW) 65688 65688 69358 69358 Low pressure turbine(lpt) 154013 154013 209936 209936 Net unit capacity (KW) 210044 210044 284679 284679 Solar power generation (KW) 0 0 74635 74635 Net efficiency (%) 34.19 31.81 32.47 35.73 Total active aperture area (m 2 ) 0 2029021 Collector field required land area (hectare) 0 244 5. CONCLUSION The exergetic analysis shows that boiler subsystem is main source of exergetic power loss in coal fired thermal power plant. The exergetic power loss in condenser is less. Analysis of solar aided feedwater heating (SAFWH) option in the coal fired thermal power plant, shows that an instantaneous increase in power generation capacity of about 35% is observed by substituting turbine bleed streams to all the low pressure and high pressure feedwater heaters with SAFWH. Coal consumption of 3.5% is increased for reheat of the steam by replacement of high pressure feed water heaters with SAFWH. With the SAFWH in coal fired thermal power plant, energetic efficiency decreases from 34.19% to 31.81% and exergetic efficiency increases from 32.47% to 35.73%. The net power generation capacity is increased from 210044 kw to 284679 kw with a land area of 244 hectare. REFERENCES [1] Indian Electricity Scenario. Available from http:/www.powermin.nic.in. Accessed on April 10, 2011. [2] Kaushik SC, Siva Reddy V, Tyagi SK. Energy and Exergy Analysis of Thermal Power Plants: A Review. Renewable and Sustainable Energy Reviews, 15, (2011), 1857-1872. [3] Gupta M K, Kaushik S C., Exergetic Utilization of Solar Energy for Feed Water Preheating in a Conventional Thermal Power Plant. International Journal of Energy Research, 33, (2009), 593 604. [4] Reddy K. S., Suresha MVJJ, Ajit K. K., 4-E (Energy, Exergy, Environment, and Economic) Analysis of Solar Thermal Aided Coal-fired Power Plants. Energy for Sustainable Development, 14, (2010), 267-279. [5] Negi B. S., Kandpal T. C., Mathur S. S., Designs and Performance Characteristics of a Linear Fresnel Reflector Solar Concentrator with a Flat Vertical Absorber. Solar & wind Technology, 7, (1990), 379-392. [6] Negi B. S., Mathur S. S., Kandpal T. C., Optical and Thermal Performance Evaluation of a Linear Fresnel Reflector Solar Concentrator I. Solar & wind Technology, 6, (1989), 589-593. [7] Klein SA, Alvarado F. Engineering Equation Solver, Version 8.629. F Chart Software, Middleton, WI. 2010.