PERMIT APPLICATION REQUIREMENTS MANDATORY DOCUMENTS: INTERIOR RENOVATIONS/BUILD OUTS CODES USED: ADOPTED FLORIDA BUILDING CODE & NEC 1. COMPLETED INTERIOR RENOVATIONS/BUILDOUT PERMIT APPLICATION PACKET. ALL APPLICABLE LINE ITEMS MUST BE FILLED OUT. OTHER DOCUMENTS, AS APPLICABLE, DEPENDING ON THE NATURE OF THE PROJECT. 1. TWO (2) SETS OF PLANS and CD: RESIDENTIAL ONE (1) REDUCED SIZE (11x17) & ONE (1) FULL SIZE (24x36) COMMERCIAL TWO (2) FULL SIZE (24x36) All plans shall include foundation, elevation, framing detail, floor plan, etc. NOTE: Load calculations required for sealed drawings along with signed, sealed, Wind Load Letter certification at dry in for sealed drawings. PROJECTS REQUIRING SIGNED AND SEALED DRAWINGS ARE LISTED BELOW PER FLORIDA STATUTE (a) PROJECTS $25,000 OR OVER (b) BUILDING 5,000 SQUARE FOOT AND OVER (may require ICC plan review) (c) BUILDINGS 3 STORIES AND OVER (may require ICC plan review) (d) ALL ASSEMBLY OCCUPANCIES (F.S. 481.229) (SCHOOLS, AUDITORIUMS, AND OTHER PUBLIC USE BLDGS) (e) ELECTRICAL SYSTEMS OVER 800 AMPS OR $125,000 (f) PLUMBING OVER 250 FIXTURE UNITS OR $125,000 (g) MECHANICAL OVER 15 TONS OR $125,000 (h) PRODUCT APPROVAL FOR EXTERIOR DOORS, WINDOWS, SKYLIGHTS, PANEL WALLS, (EIFS) STOREFRONTS, ROOFING PRODUCTS, SHUTTERS, STRUCTURAL COMPONENTS AND NEW EXTERIOR ENVELOPE PRODUCTS. (F.S. 553.842) 2. TWO (2) EACH SCALED SITE PLAN OR SURVEY: ONE (1) REDUCED SIZE (11X17) & ONE (1) FULL SIZE (24X36) CONFORMING TO LAND DEVELOMENT CODE SECTION 2.13.00 AND 2.18.02 GENERAL PLAN REQUIRMENTS. 3. WARRANTY DEED (Home Owner will need to sign owner affidavit if owner/contractor) 4. ENERGY PACKET (F.S.553) (Signed & sealed by Florida registered engineer or architect if exceeds $125,000 or 15 tons) (F.S. 471.003) 5. WATER & SEWER APPROVAL LETTER REQUIRED FROM DESTIN WATER USERS (850)-837-6146. 6. DESTIN FIRE DEPARTMENT APPROVAL LETTER REQUIRED FOR COMMERCIAL PROJECTS (850)-837-8413 7. ALL APPLICABLE CITY, STATE AND FEDERAL PERMITS (RIGHT-OF-WAY, FDEP, DOT, ARMY COE, ETC.) 8. FLORIDA PRODUCT APPROVAL NUMBERS REQUIRED (exterior doors, windows, skylights, panel walls, (EIFS) storefronts, roofing products, shutters, structural components and new exterior envelope products) (F.S. 553.842) 9. RECORDED COPY OF "NOTICE OF COMMENCEMENT" (Florida Statutes 713) NOC must be recorded with Okaloosa County Clerk of the Circuit Court and posted at the job site 10. FEMA FLOOD ELEVATION CERTIFICATE REQUIRED (AE & V zones): for pre-construction, during construction (for foundation finished floor (AE-Zone) or placement of first horizontal structural member (V-Zone)) and final. (Use current FEMA form) Final certificate must be provided prior to Final Inspection. (FEMA MAP) (LDC SECTION 11.04.00).(as applicable) OTHER REQUIREMENTS: a) PORT-O-LET OR BATHROOM FACILITIES MUST BE ON THE JOB PRIOR TO FIRST INSPECTION. b) TRASH AND DEBRIS MUST BE CONTAINED c) ADEQUATE POTABLE WATER MUST BE AVAILABLE. d) MAINTAIN EROSION AND SEDIMENT CONTROL PER LDC 10.03.2(B) DURING CONSTRUCTION OF PROJECT e) CITY IMPACT FEES MUST BE PAID PRIOR TO ISSUANCE OF CERTIFICATE OF COMPLETION
JOB SITE Community Development Department Building Division 4200 Indian Bayou Trail, Destin, Fl. 32541 Phone: (850) 654-1119 Fax: (850) 460-2171 Interior Renovation/Build-Out Permit Application DATE: NAME OF PROJECT: PARCEL ID: LOT: BLOCK: SUBDIVISION: OWNER OF PROPERTY: CONTRACTOR COMPANY NAME: QUALIFIER NAME: CITY, STATE, ZIP: STATE LICENSE #: COMP#: PHONE: FAX: MOBILE/CELL: CITY, STATE, ZIP: FEE SIMPLE TITLEHOLDER (If other than owner): PHONE: FAX: CITY, STATE, ZIP: CONTACT PERSON: MOBILE/CELL: EMAIL: ARCHITECT/ENGINEER: BONDING COMPANY: MORTGAGE LENDER NAME: DESCRIPTION OF WORK TO BE DONE: CATEGORY: Residential (SFD) Multi Family Commercial Height: Story: CURRENT CODE: OCCUPANCY USE: OCCUPANCY LOAD: TYPE OF CONSTRUCTION: I-A I-B II-A II-B III-A III-B IV V-A V-B SPRINKLED / UNSPRINKLED FLOOD ZONE: SOUTH OF CCCL: YES NO TOTAL VALUE (MATERIAL & LABOR): (excluding lot) TOTAL SQUARE FOOT: (including garage, porches, etc.) FINAL INSPECTION IS REQUIRED ON ALL PERMITS-Failure to obtain a final inspection may result in legal action. AS REQUIRED BY FLORIDA STATUTE 553.842 AND FLORIDA ADMINISTRATIVE CODE 9B-72, PLEASE PROVIDE THE INFORMATION AND APPROVAL NUMBERS ON THE BUILDING COMPONENTS IF THEY WILL BE UTILIZED ON THE CONSTRUCTION PROJECT FOR WHICH YOU ARE APPLYING FOR A BUILDING PERMIT. (Product approval specification sheet are available). Applicants Signature: Date: Reviewed by: (Building Div. Permit Officer) Date: Applicants Printed Name: Received By: (initials) Date:
Community Development Department Planning Division 4200 Indian Bayou Trail, Destin, FL 32541 Phone: (850) 837-4242 Fax: (850) 460-2171 INTERIOR REMODEL Building/Construction Permit Application Supplement JOB SITE PARCEL ID(S): FINAL DEVELOPMENT ORDER NO. (If applicable): D.O.- - DESCRIPTION OF WORK (Related to Permit Type): SHORT TERM RESIDENTIAL RENTAL UNIT (less than 180 days per year) Yes No ARE YOU INCREASING THE NUMBER OF BEDROOMS? Yes No.FOR OFFICIAL USE ONLY SOUTH OF COASTAL CONSTRUCTION CONTROL LINE? (Y/N) (If YES, provide a copy of the FDEP permit) FEMA FLOOD ZONE(S) & BASE FLOOD EL.: Received by Planning: Received by Storm water: Planning Review: Storm water Review: Flood Provision Review: Right of Way Review Date: Date: Date: Date;
Project Address: Owner/Project Name: Contractor: Contractor Phone #: PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 553.842 & Florida Administration Code 9B-72, please provide product approval numbers as applicable to project. Product suppliers should provide approval numbers for purchased items. ****Note whether doors and/or windows are: Impact or Non Impact ****State wide approval products are listed on line at: www.floridabuilding.org Category Manufacturer Product Description (Impact or Non Impact) Model Number EXAMPLE: EXAMPLE: EXAMPLE: EXAMPLE: Windows Capital Single-Hung (Impact) 165 Series, Alum Design Pressure +/- Approval # EXAMPLE: EXAMPLE: +50/-50 FL675 Applicant Signature Date
CITY OF DESTIN - BUILDING DIVISION PERMIT APPLICATION NOTICE TO OWNER / CONTRACTOR JOB SITE NAME OF PROJECT: PARCEL ID: LOT: BLOCK: SUBDIVISION: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has been commenced prior to issuance of a permit and that all work will be performed to meet all codes, standards and laws governing construction in this jurisdiction. I also certify that all required insurances for me and any trades are in accordance with state laws. I understand that a separate permit must be secured for BUILDING, ELECTRICAL WORK, PLUMBING, MECHANICAL, ROOFING, SIGNS, POOLS and Right of Way (ROW) CONSTRUCTION, etc. OWNER / CONTRACTOR AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning per State and City of Destin. If the direct contract is greater than $2500, the applicant/owner must file a NOTICE OF COMMENCEMENT. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. FINAL INSPECTION IS REQUIRED ON ALL PERMITS-Failure to obtain a final inspection may result in legal action. Must be signed in presence of a Notary Signature Owner or Agent (including contractor) Signature Contractor STATE OF FLORIDA COUNTY OF OKALOOSA Sworn to (or affirmed) and subscribed before me this STATE OF FLORIDA COUNTY OF OKALOOSA Sworn to (or affirmed) and subscribed before me this day of, 20 day of, 20 by. by. Personally known OR Personally known OR Produced Identification Produced Identification Notary Signature as to Owner Notary Signature as to Contractor SEAL: SEAL:
CITY OF DESTIN Building Division MINIMUM REQUIREMENTS FOR INSPECTION INSPECTIONS DUE DATE A certified Notice of Commencement must be posted at the job site. A copy BEFORE 1 ST of the certified notice or an affidavit must be given to the Building Division. INSPECTION 1. TEMPORARY ELECTRIC SERVICE 2. ELECTRICAL GROUNDING 3. FOOTING Minimum size footing for wood frame construction is 10" x 20". Two #5 rebar and vertical steel is required every 8 feet. 4. UNDERGROUND PLUMBING 5. SLAB - MONOLITHIC ***FOUNDATION/SLAB SURVEY IS REQUIRED TO BE REVIEWED PRIOR TO A DRY-IN INSPECTION*** (All Surveys must show finished floor elevation & elevation of centerline of road right-of-way. LDC 20.06.01A/C) 6. SHEATHING Must be nailed every 3" at top, bottom and corners, 12 in field. 7. WINDOW ATTACHMENT 8. BRICK TIES 9. SEWER Windload certification letter from an architect or engineer required for all buildings which have sealed engineered drawings. BEFORE DRY-IN 10. DRY-IN* PLUMBING ROUGH-IN ELECTRICAL ROUGH-IN MECHANICAL ROUGH-IN GAS ROUGH-IN FRAMING 11. INSULATION 12. EARLY POWER FINAL AS-BUILT SURVEY & STORMWATER CERTIFICATION REQUIRED PRIOR TO C.O. SITE INSPECTION Street address posted. BEFORE FINAL Sidewalks installed. BEFORE FINAL Parking completed. BEFORE FINAL Landscaping completed BEFORE FINAL Final Survey BEFORE FINAL Stormwater Certification from engineer BEFORE FINAL Certificate of Termite Treatment BEFORE FINAL 13. FINAL* PLUMBING ELECTRICAL MECHANICAL GAS ROOFING GENERAL CONTRACTOR *All subcontractors and the general contractor must call in before dry-in and final inspections are scheduled.