FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

Similar documents
When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

FIRM-FILL is Hacker Industries, Inc. s underlayment solution over plywood or OSB subfloors in apartments, condos, hotels and motels.

Build higher and faster with FIRM-FILL CMD (corrugated steel deck) from Hacker Industries, Inc., the leader in pourable floor underlayments.

PRODUCT GUIDELINES Hacker. Industries, Inc.

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

Triton DCI Decoupling Mat

PLYWOOD FLOATING FLOOR

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

Floor Insulation Underlayment Section Sound Control Matting

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

ENKASONIC FLOOR UNDERLAYMENT 9110

ULTIMATE SOUND CONTROL SYSTEMS

INSTALLATION INSTRUCTIONS

Presented By: Jim O Neill. Acoustics

RSIC-1 ACOUSTIC ASSEMBLY

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

PinkWood Ltd. Revised September 29, 2017

ARDEX DS 70 TM. Acoustic Mat

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

FIRM-FILL High Strength

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

DIVISION 9 - SECTION QTscu Recycled Rubber Sound Underlayment US Patent No. RE 41,945

It s not magic, it s engineering. Impact and Airborne Sound Control. GenieClip. US Patent No. 7,895,803

RESILIENT SOUND ISOLATION CLIPS

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

SECTION WOOD FLOORING

SECTION WOOD FLOORING. 1. Section Above-Grade Vapor Retarders. 2. Section Below-Grade Vapor Retarders

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

Soundproofing of Wood-frame buildings

FIRE & SOUND MANUAL ARCHITECT VERSION 6.17

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

UNDERLAYMENT INSTALLATION INSTRUCTIONS

Design No. L565. Design No. L565

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

AcoustiFloat HI-SEP Floating Floor Specification (Canada)

A. Background on Floor/Ceiling Noise Issues. Addressing Floor/Ceiling Noise Issues in Multifamily Construction

FLOORING INSTALLATION SYSTEMS. Product Catalog

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to AMORIM CORK COMPOSITES

FlexLok Adhesive Tabs for Carpet Tile

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

SPECIAL PROCEDURES INSTALLATION & WARRANTY

Vibration Isolation of Floating Floors

Installation Guide LVP Glue Down

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

Page 1 of 5 PART 1 GENERAL

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Report on Structural Stability of Engineered Lumber in Fire Conditions

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to SENECA RADIANT TECHNOLOGIES

Signatures are required on this document for an official laboratory test report. Copies of this document without signatures are for reference only.

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

138 H-STUD AREA SEPARATION WALL SYSTEM

Gold Bond BRAND Gypsum Sheathing

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

2000 POCKET DOOR TECHNICAL DATA

Product Installation Manual

ARDEX UI 720 FLEXBONE

GIB Quiet Clip GIB CBI March Features and Benefits

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

Section Sound Control

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

This page was. intentionally. left blank

INSTALLATION INSTRUCTIONS LAMINATE

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Updated 1/25/13. Supercedes all previous versions. Check website for updates. ASE PREPARATIO

Scuba Seal Installation / Floor Care Instructions With Video Link

The GlasRoc Shaftliner Type X advantage...

HAMBRO COMPOSITE FLOOR SYSTEM

Guide for Sound Insulation in Wood Frame Construction

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems

SECTION GYPSUM BOARD

ACOUSTICAL WALL TREATMENT SECTION 09840

Fire Barrier Duct Wrap 615+

Transcription:

Specify FILL SCM-400 for additional impact noise control when a thicker sound mat is needed. It helps achieve higher delta numbers than thinner mats. FILL SCM-400 is a cost-effective way to address Impact Insulation Class (IIC) concerns. This sound mat offers great performance in wood or concrete construction. FILL SCM-400 can be installed under a FILL Gypsum Floor Underlayment to produce an exceptional vibration isolation floor system. An advanced solution for additional impact noise control between hard surfaces and carpeted areas Used in wood frame construction and as a component of a well designed floor/ceiling assembly Cost-effective way to address noise concerns and to improve IIC ratings Minimal deflection, no creep or long term degradation Specify with a FILL Gypsum Underlayment Installed by trained Licensed Applicators

1 - FLOOR COVERING / 2 - BRAND GYPSUM CONCRETE / 3 - SCM -400 / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11-6 CONCRETE Compression Resistance 0.5 0.4 0.3 0.2 0.1 0 Beginning Thickness Deflection During Load Residual Thickness 42 lb/ft² 105 lb/ft² 505 lb/ft² Transmission Loss (db) 90 80 70 60 50 40 30 20 10 0 100 160 250 FILL SCM-400 STC 52 Reference Contour 4000 2500 1600 1000 630 400 Frequency (Hz) Ln (db) 100 90 80 70 60 50 40 30 20 10 0 50 FILL SCM-400 IC Contour 800 500 310 200 125 80 Frequency (Hz) 1250 2000 3150 5000 IIC + STC + 2017 Hacker Industries, Inc. and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. Performance in wood-frame and concrete structures Requires dryin (building must be fully enclosed before installation) Install isolation barrier around perimeter of floor Improves Impact Insulation Class (IIC) ratings May not be used as a vapor barrier Install SCM-400 mat with purple mesh down Improves Transmission Class (STC) ratings L/360 Deflection must not exceed L/360 live or dead load Tape all seams with duct tape or 2 wide tape Allows vapor to pass through to prevent trapped moisture Do not use Mechanical Fasteners Install Brand Gypsum Class A Fire-rated Product Must be used with Gypsum Apply Hacker TopCoat SP when specified Installed by Hacker Industries trained Licensed Applicators Robinson Wheel tested Extra Heavy Duty Install finished floor covering only when completely dry 114 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017

TECHNICAL DATA PROPERTIES Roll Weight 39 lb (17.7 kg) Thickness 3/8 in (10 mm) nominal Width 60 in (152.4 cm) Core Color Purple Packaging Length 80 ft (24.5 m) Total Square Feet 400 ft² (37.16 m²) Effectiveness of Reducing IIC ΔIIC 20.0` Steiner Tunnel Test Class A Benefits Provides additional impact noise control when a thicker sound mat is specified Cost-effective way to address Impact Insulation Class (IIC) concerns Minimal deflection, no creep or long term degradation Excellent performance in wood frame construction and concrete structures Helps to achieve higher delta IIC numbers Installed only by trained Licensed Applicators across North America Product Description FILL SCM-400 is a nominal 3/8 (10 mm), entangled polymeric filament sound control mat designed to limit impact noise between floors. Designed for critical applications in which FILL Gypsum will be utilized. Use in conjunction with a minimum 1-1/4 FILL Gypsum topping. Limitations Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. Shall not be used without a FILL Gypsum topping. Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. Do not use mechanical fasteners to install FILL SCM-400, as mechanical fasteners conduct impact sound, reducing acoustical isolation. FILL SCM-400 shall be installed with a perimeter isolation strip. FILL SCM-400 is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies. Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50 F (10 C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017 115

INSTALLATION(cont.) Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. FILL SCM-400 is laid directly over the concrete, plywood or OSB subfloor, with the purple mesh down and white/purple fabric side up. It should be pushed up tightly to the isolation barrier. Alternately, the FILL SCM-400 may be pushed up tightly to the gypsum wall when the isolation barrier installed is FILL Perimeter Isolation. The gap between the floor and wall shall not exceed 0.25 (6 mm). FILL SCM-400 edge must be placed adjacent to other pieces without any gap. Rolls are manufactured with the self-adhesive selvage edge folded over on the fabric top. When unrolled, the selvage edge remains in position. Starting at the base of the roll, smooth the selvage edge to the adjacent piece. If necessary, tape (duct tape or 2 [51 mm]-wide tape) the 3 (76 mm) fabric overlaps snug to the fabric on the adjoining FILL SCM-400 strip. Tape all seams to prevent penetration into the core material during pour. Double tape seams if necessary. Finished floor coverings can be installed when the FILL Gypsum is completely dry. Consult flooring contractor for acceptable levels of moisture and recommended procedures to test for dryness. Reference Hacker Industries, Inc. s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419. Product Data Core Thickness: 3/8 in (10 mm) nominal Roll Weight: 39 lb (17.7 kg) Packaging Length: 80 ft (24.5 m) Core Width: 60 in (149 cm) Total square feet: 400 ft² (37.16 m²) Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc. s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects and general contractors recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc. s website. Hacker Industries, Inc. regularly performs acoustical and fire (UL) testing to ensure performance standards for our products. Firm Fill SCM (sound control mats), including Firm Fill SCM-400, were tested acoustically with the following floor assemblies and performed as noted. 116 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017

Subfloor Topping 1-1/4 (32 mm) Brand Gypsum 3/8" (10 mm) SCM-400 Control Firm-Fill SCM-400 Open Web Subfloor Insulation Truss Ceiling Isolation 3/4" (19 mm) oriented strand 3-1/2" (89 mm) unfaced R-13 fiberglass insulation 18" (457 mm) L/360 open web truss Clark Dietrich RCSD Resilient Channel Ceiling Finish Rating 5/8" (16 mm) type C gypsum STC IIC Report # Bare 61 50 D6435.15 Plank 3 mm Vinyl Tile Sheet 7 mm Sheet Vinyl with Rubber Backing 13 mm Engineered Wood 8 mm Ceramic Tile 62 53 D6435.16 62 54 D6435.17 62 53 D6435.18 61 58 D6435.19 61 58 D6435.20 61 -- D6435.21 UL Fire Rated Designs Open Web L521, L528, L529, L534, L542, L546, L550, L558, L563, L574, L576, L577, L579, L583, L585, L592, M500, M503, M508 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017 117

Subfloor Topping 1-1/4 (32 mm) Brand Gypsum 3/8" (10 mm) SCM-400 Control Firm-Fill SCM-400 Nominal Wood Subfloor Insulation Truss Ceiling Isolation 3/4" (19 mm) oriented strand 3-1/2" (89 mm) R-13 fiberglass insulation 9-1/4" (235 mm) 2x10 Clark Dietrich RCSD Resilient Channel Ceiling Finish Rating 5/8" (16 mm) type C gypsum STC IIC Report # Bare 59 -- E3147.01 Plank 3 mm Vinyl Tile Sheet 7 mm Sheet Vinyl with Rubber Backing 13 mm Engineered Wood 8 mm Ceramic Tile 61 52 E3147.02 61 53 E3147.03 60 53 E3147.04 59 58 E3147.05 59 57 E3147.06 59 51 E3147.07 UL Fire Rated Designs Nominal Wood L006, L201, L202, L206, L208, L209, L210, L211, L212, L501, L502, L503, L504, L505, L506, L507, L508, L509, L510, L511, L512, L513, L514, L515, L516, L517, L519, L520, L522, L523, L525, L526, L532, L533, L535, L536, L537, L540, L541, L545, L557, L569, L588, L590, L593, L598, M504, M517, M519, M530, M531, M517 118 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017

Subfloor Topping 1-1/4 (32 mm) 3310 Gypsum 3/8" (10 mm) SCM-400 Control Firm-Fill SCM-400 I-Joist Subfloor Insulation Truss Ceiling Isolation 3/4" (19 mm) oriented strand 3-1/2" (89 mm) R-11 fiberglass insulation 12" (302 mm) Clark Dietrich RCSD Resilient Channel Ceiling Finish Rating 2 layers 5/8" (16 mm) type C gypsum STC IIC Report # Bare 61 51 E7892.08 Plank 3 mm Vinyl Tile Sheet 7 mm Sheet Vinyl with Rubber Backing 13 mm Engineered Wood¹ 13 mm Engineered Wood 8 mm Ceramic Tile 62 54 E7892.09 62 58 E7892.10 61 54 E7892.11 61 58 E7892.12 62 54 E7892.06 -- 60 E7892.13 61 55 E7892.14 ¹Assembly differs from above in the following: Ceiling: 1 layer 5/8 (16 mm) type C gypsum Note: Preceding I-Joist with 1 layer gypsum tests were conducted with increasing compressive strength and density, which may affect sound performance. I-Joist UL Fire Rated Designs L518, L530, L538, L547, L556, L570, L581, L589, M502, M506, M512 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017 119

Subfloor Topping 1-1/4 (32 mm) Brand Gypsum 3/8" (10 mm) SCM-400 Control Firm-Fill SCM-400 Assembly Subfloor Insulation Truss Ceiling Isolation 6" (152 mm) concrete Ceiling Finish Rating Report # None None None None Bare 52 -- 5014051 STC IIC Bare -- 50 7014063 Sheet Vinyl -- 50 7014064 Bare -- 23* 7014091 *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Transmission Through Floors. UL Fire Rated Designs J917, J919, J920, J924, J927, J931, J957, J991, J994 *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Transmission Through Floors. Warranty Subject to express warranty stated on Hacker Industries, Inc. s website. Submittal Approvals Project Name Contractor/Architect Signature Date PRODUCT INFORMATION See www.hackerindustries.com for current recommended product specifications and literature. SCM-400, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is affected by every other component and the likelihood of achieving code compliance is contingent upon many other trades, including framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. WARNING Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations. TRADEMARKS, GYP-SPAN, Let Our Products Floor You and the associated logos are trademarks of Hacker Industries, Inc. LEED is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. HACKER'S LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. 2017 Hacker Industries, Inc., Newport Beach, CA. 120 Hacker Industries, Inc. Architect Binder Firm-Fill SCM-400 2017