The absorptions vessel was filled with 6ml HCL, Suprapur, VWR art.: and 2ml HNO3, Suprapur, VWR art.:

Similar documents
Composition Analysis of Animal Feed by HR ICP-OES

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

The image part with relationship ID rid4 was not found in the file. Welcome

DRPK-005

GB Translated English of Chinese Standard: GB

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Assaying and Analysis Choices in Practice

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

The texts of the chapters 1-11 are normative; annexes are normative or informative, as stated in the top lines of the annexes.

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Avio 200 ICP-OES Flat Plate

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

Sorting and Drying Code Price Unit. Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample

SVENSK STANDARD SS-EN 14082

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

METHOD 0060 DETERMINATION OF METALS IN STACK EMISSIONS

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

DRAFT EAST AFRICAN STANDARD

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Analysis of Anions in Lake Water by IC, and Trace Metals in Core Sediments by ICP-AES and GFAAS

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

High Purity Acids Trace Elemental Analysis. Detect as low as 1 to 100 ppt

This document is a preview generated by EVS

Nitrogen, Simplified TKN (s-tkn ) DOC

Heavy Metal Contamination and Distribution in the Parks City of Islam Shahr, SW Tehran, Iran

High-Purity Acids & Reagents

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

HEAVY METAL SOIL CONTENT AS AN INDICATOR OF POLLUTION

Analytica Chimica Acta

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

EVOLUTION OF TRACE METAL REMOVAL PRODUCTS IN FIELD-SCALE VERTICAL FLOW BIOREACTORS

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

Surface Water Samples: Containers, Preservation and Hold Times Table

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

Formazin 4000FTU / 1000EBC / 8200ppm

Standard Operation Procedure. Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS

ISO INTERNATIONAL STANDARD

R = kc Eqn 5.1. R = k C Eqn 5.2. R = kc + B Eqn 5.3

Characteristics and mobility of heavy metals in an MSW landfill: Implications in risk assessment and reclamation

TECHNICAL DATA SHEET CUPROBRITE Revolutionary & New generation Bright Acid Copper Plating Process

METHOD 3031 ACID DIGESTION OF OILS FOR METALS ANALYSIS BY ATOMIC ABSORPTION OR ICP SPECTROMETRY

National Food Safety Standard

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Matanza-Riachuelo Basin Part 3: Storm water / Urban runoff / Sewage

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Metals in the Benthic Macroinvertebrates in Coal Creek, Crested Butte, CO

The Spatial Variability of Total and Bioavailable Metal Concentrations in the Sediments of Mitchell Lake

MILAF: INTEGRAL MANAGEMENT OF ARSENICAL SLUDGE, TREATMENT AND RECOVERY OF BY-PRODUCTS OF ACID WATERS FROM SMELTER PLANTS

Extraction of certain heavy metals from sewage sludge using different types of acids

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

Nuclear Engineering Seibersdorf GmbH

Methods for determination of mercury in LP gas

Page 2 of 14 Test Result(s) PART NAME No.1 COPPER BONDING WIRE Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Hexavalent

Trace Element Analysis of Industrial Wastewater and Sewage with TXRF. Bruker Nano GmbH Berlin, Germany, February 23 rd, 2011

GREAT RESULTS BEGIN WITH GOOD PREPARATION. Titan MPS Microwave Sample Preparation System A Reference Notebook of Microwave Applications

Comparative study of optimised BCR sequential extraction scheme and acid leaching of elements in the certified reference material NIST 2711

- HSS-Blade (EOS art.-no ) - 90 µm mesh for powder sieving recommended (EOS art.-no ) - Argon atmosphere

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

ISO TC 174 WG 1 and Daily work with- ISO and ISO Stefan Zorn Head of Laboratories Agosi/ Umicore BU JIM

Journal of Hazardous Materials

Precious Metals in High Temperature Geothermal Systems

Elemental impurities and their measurement. a: 119 Magowar Rd, Girraween 2145 p: (02) f: (02)

Equipment Needs and Maintenance, What is Required in the Wet Chemistry Laboratory for Manual Method Testing

PERFORMANCE ANALYSIS OF BENCHMARK PLANT FOR SELECTIVE LITHIUM RECOVERY FROM SEAWATER

Using low grade silicon carbide and leftover construction soil to fabricate green bricks

DURNI-COAT DNC

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

The Certification of the Mass Fractions of As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Sb, Se, Tl, V and Zn in fly ash BCR-176R

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

Certificate of Analysis

Heavy metals concentration in tannery effluents, associated surface water and soil at Ejersa Area of East Shoa, Ethiopia

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Metal and Particulate Emissions from Incinerators Burning Sewage Sludge and Mixed Refuse

CORESTA RECOMMENDED METHOD N 61

Corrosion Studies on GeoBrom HG520

On site heavy metal testing and monitoring using monochromatic XRF methods

Standard Test Methods for Iron in Water 1

Test Report No CH02 Date: June 30, 2017 Page 1 of 9

Supporting Information. Photochromic, Photoelectric and Fluorescent Properties

Voting Card on A Final Project

Method for Estimation of Na 2 O and K 2 O in Ores, Fluxes, Coal and Coke Ash by Inductively Coupled Plasma-Atomic Emission Spectroscopy

TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

Material data sheet. EOS MaragingSteel MS1. Description

Material data sheet. EOS MaragingSteel MS1. Description

Study on the Pollution Levels of Trace Metals from Modjo Tannery Effluent in the Surrounding River Water and Soil

This document is made available electronically by the Minnesota Legislative Reference Library as part of an ongoing digital archiving project.

Transcription:

ANNEX 1 DIGESTION PROCEDURES Procedures of Aqua regia digestion A.1.1 Thermal heating digestion with Aqua regia: Digestions performed at NUA: The procedure of method A of the draft standard was followed. Mass of test portion: about. 3g of sample moistened with 0,5ml H2O 7ml HNO3, Suprapur, VWR art.:1.00318 21ml HCL, Suprapur, VWR art.:1.00441 The absorptions vessel was filled with 6ml HCL, Suprapur, VWR art.:1.00441 and 2ml HNO3, Suprapur, VWR art.:1.00318. Programme: 2h under reflux conditions with condensation zone 1/3 the height of the condenser Cool down Addition of the content from the absorption vessel via the condenser Both the absorptions vessel and the condenser were rinsed with doubled deionised water. The digest was transferred to a volumetric flask and filled up to 200ml with doubled deionised water. Before measurement the sample was allowed to settle down. Measurement: Instrument: ICP-OES. Optima 3000XL, Perkin Elmer Sample Preparation: sample dilution with aqua regia in following Steps 10,100, 1000 Internal Standardisation with Ytterbium calibration in aqua regia matrix Apparatus for digestion: composed glassware and heating devices by NUA-UA GmbH Location: NUA-Umweltanalytik GMBH Südstadtzentrum 4 2344 Maria Enzersdorf

Figure A 1.1 Apparatus for thermal heating digestion Digestions performed at LHL in Kassel: Mass of test portion: about 3g of sample for soil samples, about 1,5 g of sample for compost and sludge moistened with 0,5 ml deionised H2O 7 ml HNO3, p.a., 21 ml HCL, Suprapur, Used vessels: conventional glassware, cleaning in the washer, rinsing with deionised water The absorptions vessel was filled with 2M HNO3 solution. Programme: let stand overnight, cooking 2h under reflux conditions with condensation zone 1/3 the height of the condenser Cool down Addition of the content from the absorption vessel via the condenser Both the absorptions vessel and the condenser were rinsed with doubled deionised water. The digest was transferred to a volumetric flask and filled up to 100ml with deionised water. Before measurement the sample was allowed to settle down. A.1.2 Closed Microwave digestion with Aqua regia: Digestions performed at NUA: The procedure of method B of the horizontal draft standard was followed. Mass of test portion: about 0,5g of sample

Added reagents: 2ml HNO3, Suprapur, VWR art.:1.00318 6ml HCL, Suprapur, VWR art.:1.00441 Quartz vessels were used and cleaned by cooking with aqua regia Programme for a batch of 6 samples: Table 1.1 Programme for closed microwave oven Time (min) Power(W) 2 250 2 0 5 250 5 400 5 500 After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled to 50ml with doubled deionised water. Before measurement the sample was allowed to settle down. Recording of temperature and pressure was done during digestion. Measurement: Instrument: ICP-OES. Optima 3000XL, Perkin Elmer Sample Preparation: sample dilution with aqua regia in following Steps 10,100, 1000 Internal Standardisation with Ytterbium Calibration in aqua regia matrix Apparatus for digestion: Anton Paar, Multiwave Location: NUA-Umweltanalytik GMBH Südstadtzentrum 4 2344 Maria Enzerdorf Figure A 1.2 Apparatus for closed microwave digestion

Digestions performed at Eurofins: The procedure of method B of the horizontal draft standard was followed. Mass of test portion: about 0,25g 0,4 g of sample Added reagents: 2ml HNO3, 6ml HCL, Programme for a batch of 6 samples: Table A.2 Programme for closed microwave oven Time (min) Power(W) 2 250 2 0 5 250 5 400 5 500 After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled up. Apparatus for digestion: Location: Eurofins, Denmark

Digestions performed at LHL in Kassel: Mass of test portion: about 0,4g of sample for soil samples, about 0,2 g for sludge and compost samples Added reagents: 1 ml HNO3, p.a: 3 ml HCL, Suprapur, Teflon vessels were used and cleaned by rinsing the vessels three times with diluted nitric acid Microwave oven used: MLS 1200 Programme for a batch of 6 samples: Table A 1.3 Programme for closed microwave oven at LHL Kassel Time (min) Power(W) 4 250 2 0 1,3 250 2 450 5 850 1 250 After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled to 25ml with doubled deionised water. Before measurement the sample was allowed to settle down. Digestions performed at UBA Wien: Procedure 1: The procedure of method B of the horizontal draft standard was followed. Mass of test portion: about 0,3 respectively 0,5g of sample Added reagents: 2ml HNO3, Suprapur, 6ml HCL, Suprapur, Quartz vessels were used and cleaned by cooking with aqua regia Programme for a batch of 6 samples: Table A 1.4 Programme for closed microwave oven Time (min) Power(W) 2 250 2 0 5 250 5 400 5 500 After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled to 50ml with doubled deionised water. Then the samples were filtrated through a folded filter (Macherey-Nagel MN280 ¼, 150 mm diameter).

Measurement: Instrument: ICP-OES. Optima 3000DV, Perkin Elmer Calibration in aqua regia matrix Analysis of quality control solutions after calibration and at the end Analysis of samples, spiked with known amounts of Al, B, Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn standards ICP-OES according to ON EN 11885 (modified) Apparatus for digestion: Anton Paar, Multiwave Location: Umweltbundesamt Wien Figure A 1.3 Temperature and Power Programme closed microwave UBA Wien for procedure 1 with mass of test portion of 0,3 g

Figure A 1.4 Temperature and Power Programme closed microwave UBA Wien for procedure 1 with mass of test portion of 0,5 g UBA Procedure 2: Mass of test portion: about 0,3 respectively 0,5g of sample Added reagents: 2ml HNO3,p.A, subboiled 6ml HCL, p.a, subboiled Quartz vessels were used and cleaned by cooking with aqua regia Programme for a batch of 6 samples: Table A 1.5 Programme for closed microwave oven Time (min) Power(W) 5 200 25 900 15 0

After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled to 50ml with doubled deionised water. Then the samples were filtrated through a folded filter (Macherey-Nagel MN280 ¼, 150 mm diameter). Measurement: Instrument: ICP-OES. Optima 3000DV, Perkin Elmer Calibration in aqua regia matrix Analysis of quality control solutions after calibration and at the end Analysis of samples, spiked with known amounts of Al, B, Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn standards ICP-OES according to ON EN 11885 (modified) Apparatus for digestion: Anton Paar, Multiwave Location: Umweltbundesamt Wien Figure A 1.5 Temperature and Power Programme closed microwave UBA Procedure 2 - High Temperature Power programme, mass of test portion of 0,3 g

Figure A 1.6 Temperature and Power Programme closed microwave UBA Procedure 2 - High Temperature Power programme, mass of test portion of 0,3 g

A.1.3 Open Microwave digestion with Aqua regia: The method C described in the first version (2004) of the horizontal draft standard was followed. Mass of test portion: about. 0,5g of sample 6ml HNO3, Suprapur, VWR art.:1.00318 18ml HCL, Suprapur, VWR art.:1.00441 Instrument: CEM Star System Location: Fernwärme Wien Simmeringer Haide 11. Haidequerstrasse 6 1110 Wien Figure A 1.7 Apparatus for open microwave digestion Programme for a batch of 2 samples: Table A 1.6 Programme for open microwave digestion Time (min) Temperature( C) 3 103 12 103 3 103 12 103 After digestion the vessels were allowed to cool down, transferred quantitatively to a volumetric flask and filled to 50ml with doubled deionised water. Before measurement the sample was allowed to settle down.