AccuSEQ Real-Time PCR Detection Software

Similar documents
Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Perform an HRM Methylation Study

AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software

Applied Biosystems 7500 Fast Real-Time PCR System

User Bulletin. ABI PRISM 7000 Sequence Detection System DRAFT. SUBJECT: Software Upgrade from Version 1.0 to 1.1. Version 1.

SUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Real-Time PCR ABI Prism 7500 (PSC 563, NSC 338) Real-Time PCR StepOne (PSC 563)

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Procedure for DNA Quantitation with Quantifiler Duo

Applied Biosystems TaqMan Array Microfluidic Cards

Georgia Bureau of Investigation - Division of Forensic Sciences DNA Procedures Manual DNA QUANTIFICATION USING QUANTIFILER HUMAN / Y HUMAN MALE KIT

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

Custom dye calibration for StepOne and StepOnePlus Real-Time PCR Systems

ReadMe Software v2.0.1 For Applied Biosystems 7500 and 7500 Fast Real-Time PCR Systems

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Plexor HY System for the Applied Biosystems 7500 and 7500 FAST Real-Time PCR Systems

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Troubleshooting Chemistry and Assay Runs

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

VERSANT kpcr Molecular System

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Quantitative Real time PCR. Only for teaching purposes - not for reproduction or sale

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

ViiA 7 Real-Time PCR System

Multiplex RT for TaqMan Array Human MicroRNA Panel

PROTOCOL. ViralSEQ Mouse Minute Virus (MMV) Real-Time PCR Detection Kit

Module1TheBasicsofRealTimePCR Monday, March 19, 2007

PowerPlex Matrix Standards, 3100/3130

Relative Quantification Applied Biosystems 7300/7500/7500 Fast Real-Time PCR System

For in vitro Veterinary Diagnostics only. Real-Time PCR Detection Kit for detection of Histomonas meleagridis.

PowerPlex 5-Dye Matrix Standards, 310

QIAGEN Supplementary Protocol

PowerPlex 5C Matrix Standards, 310

Setting Up a Multiplex (two probe) Real Time 5 Nuclease Reaction on the ABI PRISM 7700 Sequence Detection System

Guide to using the Bio Rad CFX96 Real Time PCR Machine

TaqMan Pseudomonas aeruginosa Detection Kit

TaqMan Cytokine Gene Expression Plate I Protocol

Relative Quantification Getting Started Guide

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

PowerPlex 4C Matrix Standard

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Procedure for GeneMapper ID-X for Casework

Brilliant II SYBR Green QPCR Master Mix

PowerPlex 5-Dye Matrix Standards, 3100/3130

Shift Swapping Quick-Guide

BigDye Direct Cycle Sequencing Kit

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

TECHNICAL MANUAL. ProNex DNA QC Assay. for Use on the Bio-Rad CFX96 Touch Real-Time. PCR Detection System

Software manual. Thermo Scientific PathoProof Norden Lab Studio Instructions for use

MyiQ Single-Color Real-Time PCR Detection System

Relative Quantification Getting Started Guide

How to get started with HDPOSsmart? HDPOS smart Tutorials

foodproof Magnetic Preparation Kit I

Technical Review. Real time PCR

About SMART Practice Aids - Field Work

Or, from the View and Manage RFx(s) page, click the Create RFx button. Create New RFx - Use this button to create an RFQ from scratch.

Data Quality Worth Sharing

Evolution Payroll. User Guide (Basic Version) 2017 Payroll Solutions, Inc &

The Seed Health Toolbox II. Molecular Seed Testing Methods and Processes: What are the sources of variability?

Table of contents. Reports...15 Printing reports Resources...30 Accessing help...30 Technical support numbers...31

Administrator Quick Reference Virtual TimeClock 15 Network Edition

HUMAN EMBRYONIC STEM CELL (hesc) ASSESSMENT BY REAL-TIME POLYMERASE CHAIN REACTION (PCR)

Applied Biosystems QuantStudio 12K Flex Real- Time PCR System: OpenArray Plate

Completing an Internal Audit User Guide For the Reliance Assessment Database

SECTION 15 CARTON REQUIREMENTS

Brilliant SYBR Green QPCR Master Mix

SYBR Green Realtime PCR Master Mix

TECHNICAL MANUAL. GenePrint 24 System. Instructions for Use of Product B1870 6/16 TM465

C.albicans/C.glabrata/C.krusei Real-TM Handbook

Managing a FedEx Shipping Label within SoftPro 360

M. tuberculosis_mpb64/is61 10 genesig Standard Kit

RealLine Food Kit Turkey Detect

Microsoft Dynamics GP. Purchase Order Processing

Agilent 6500 Series Q-TOF LC/MS System

FemINDICAtor qpcr Plant Gender Detection Kit on the BIO-RAD CFX96 Touch Real- Time PCR Detection System Page 1 of 11

QIAGEN GeneRead QIAact Panel Cleanup Kit Handbook

Microsoft Office Project 2010 Basic Course 01: Getting Started

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

CHAPTER 10 ACQUISITION AND PAYMENTS

Relative Fluorescent Quantitation on Capillary Electrophoresis Systems:

Instructions for Use. RealStar Lassa Virus RT-PCR Kit /2017 EN

User Manual. VisiBlue qpcr mix colorant. Version 1.3 September 2012 For use in quantitative real-time PCR

AmoyDx TM JAK2 V617F Mutation Detection Kit

Neisseria gonorrhoeae Real-TM

TaqMan PreAmp Master Mix Kit. Protocol

quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

Same TaqMan Assay quality, new format

Axiom TM 2.0 Automated Target Prep Protocol

DNA Genotyping from Human FFPE Samples Reliable and Reproducible

Octet RED384 Getting Started. Sample Preparation Guidelines. Recommended concentration ranges

KAPA PROBE FAST qpcr Master Mix (2X) Kit

User Bulletin #2. ABI PRISM 7700 Sequence Detection System. Introduction. Contents. December 11, 1997

Solar Eclipse Product Serial Numbers. Release 9.0.1

Power SYBR Green RNA-to-C T 1-Step Kit. Protocol

University of Massachusetts Amherst * Boston * Dartmouth * Lowell * President s Office * Worcester

Purchase Order, Requisitions, Inventory Hands On. Workshop: Purchase Order, Requisitions, Inventory Hands On

Oracle Fusion Applications

AmpFlSTR NGM SElect PCR Amplification Kit. User Guide

Transcription:

Quick Reference Card AccuSEQ Real-Time PCR Detection Software Mycoplasma SEQ Experiments Note: For safety and biohazard guidelines, refer to the Safety section in the AccuSEQ Real-Time PCR Detection Software Mycoplasma Experiments Getting Started Guide (PN 4425587). For every chemical, read the MSDS and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. Overview About the AccuSEQ Software Applied Biosystems AccuSEQ Software is detection and analysis software used with Real-Time PCR (polymerase chain reaction) assays for impurity and contaminant analysis in pharmaceutical quality control and process development environments. This quick reference card provides abbreviated procedures for creating, analyzing, viewing, and interpreting Mycoplasma SEQ experiments using the AccuSEQ software. Related documents AccuSEQ Software v1.0 Help Access the Help system by pressing F1, by clicking in the toolbar of the AccuSEQ Software window, or by selecting HelpContents and Index. Documents shipped with the software: AccuSEQ Real-Time PCR Detection Software Mycoplasma Experiments Getting Started Guide AccuSEQ Real-Time PCR Detection Software Custom Experiments Quick Reference Card MicroSEQ Mycoplasma Real-Time PCR Detection Kit Protocol About Mycoplasma SEQ experiments The SEQ Experiment workflow calculates reagent volumes, determines optimum plate setup, guides you through experiment set up, uses optimized thermal cycling conditions, and performs data analysis. The Mycoplasma SEQ experiment workflow is designed to set up, run, and analyze samples prepared with the MicroSEQ Mycoplasma Real-Time PCR Detection Kit. Perform a Mycoplasma SEQ experiment to detect the presence of mycoplasma species nucleic acid sequence in a sample. Mycoplasma SEQ experiment workflow The following flowchart summarizes the steps for performing a typical Mycoplasma SEQ experiment workflow using the AccuSEQ software. Step 1: Set up the experiment (page 2) Create a new experiment. Define the experiment properties. Set up the samples and controls. Review the reaction setup. Finish the experiment setup. Step 2: Prepare the reactions (page 3) Step 3: Run the experiment (page 3) Prepare for the run. Start the run. (Optional) Monitor the run. Unload the instrument. Step 4: Review the Results Summary (page 3) Step 5: (Optional) Review the results (page 4) Review the Quality Summary. Review the amplification plot. Review the melt curve. Review the table data. Step 6: (Optional) Investigate the results (page 5) Review multiple plots. Review the analysis settings. Omit wells from the analysis. Step 7: (Optional) Export and print the data (page 5) Export data. Print a report. Print SAE reports. IMPORTANT! The Mycoplasma SEQ experiment performs a presence/absence assay and analyzes melt curve data. The SEQ presence/absence assay and the melt curve algorithm are customized for detection of specific organisms and species and may yield different results than a custom presence/ absence experiment or a custom melt curve experiment.

Step 1: Set up the experiment Create a new experiment 1. In the desktop, double click (AccuSEQ Software) to start the software. 2. Log in to the software. See your system administrator for username and password. Note: If you have Administrator privileges, you can enable or disable the Security, Audit, and E-Sig (SAE) settings for experiments. For more information, see the AccuSEQ Software Help. 3. In the Home screen, click Create SEQ Experiment to open the SEQ Experiment workflow. 4. In the SEQ assay selection dialog, verify that Mycoplasma Assay Software Module v1.0 is selected from the presence/absence assay group, then click Next. Define the experiment properties Experiment, reagents, run method, and target(s) are defined by the software based on the SEQ assay selected when you created the experiment. In the Experiment Properties screen: 1. Enter an experiment name that is descriptive and easy to remember. 2. (Optional) Enter a barcode to identify the barcode on the reaction plate. 3. (Optional) Enter comments to describe the experiment. 4. Verify the SEQ experiment type and assay to use, then click Next. Set up the samples and controls In the Sample Setup screen: 1. Specify the number of samples and replicates: Field Minimum Entry Samples 1 Sample replicates 1 Inhibition control replicates for each sample 1 Positive control replicates 1 Negative control replicates 1 Use at least one negative and one positive control per run, and at least one inhibition control per sample. 2. Set the Sample volume per reaction (2-10 µl). Note: Applied Biosystems recommends a sample volume per reaction of 10 µl for Mycoplasma SEQ experiments. The 7500 Fast system supports total reaction volumes from 10 to 30 µl. 3. Enter sample names. 4. (Optional) Set plot colors. 5. Click Next. Review the reaction setup The AccuSEQ software uses the sample information that you enter in the Sample Setup screen to fill the wells in the plate layout (see below) and to calculate the required reaction component volumes for each sample type, based on the Mycoplasma Real-Time PCR Detection Kit Protocol guidelines. View the plate layout The Plate Layout tab displays information about each well in the reaction plate in an illustration. Review and adjust the plate layout (click-drag or Swap wells) as needed, then click Next. IMPORTANT! If you want to modify the default plate layout, refer to the Mycoplasma Real-Time PCR Detection Kit Protocol for plate layout suggestions. Print the experiment setup Print the experiment setup for use in reaction preparation. 1. In the Print Experiment Setup screen, select the elements to include in the report: Experiment Summary Detailed Instructions Plate Layout 2. Click Preview, Save As PDF (or HTML), or Print. Finish the experiment setup Click Save & Finish in the open experiment screen, specify a name and location for the.eds file, then click OK. Specify a reason for change, if For more information, see the AccuSEQ Software Help. IMPORTANT! Do not manipulate the experiment files stored on the hard drive of the computer. If you do so, you will corrupt the experiment file and you will not be able to open it in the AccuSEQ software. Page 2

GR2477 7300/7500 barcode on plate AccuSEQ Real-Time PCR Detection Software Mycoplasma Experiments Quick Reference Card Step 2: Prepare the reactions For a Mycoplasma SEQ experiment, you prepare PCR reactions that contain primers designed to amplify the mycoplasma targets and a reagent to detect amplification of the targets. 1. Prepare the PCR reactions as described in the printed reaction setup worksheet. 2. Pipette samples into the plate according to the printed plate layout. For details on plate sealing, see the Mycoplasma Real- Time PCR Detection Kit Protocol. Step 3: Run the experiment Prepare for the run Open the experiment 1. Select File Open from the toolbar to open the experiment you saved when you set up the experiment. 2. In the dialog box that opens, select the experiment, then click Open. (Optional) Enable the notification settings If you want the system to send email notifications about the instrument run: 1. In the navigation pane, select Run Notification Settings. 2. Select Yes to enable notifications, then define the notification settings. See the AccuSEQ Software Help for more information. Start the run Load the instrument 1. Push the tray door to open it. 2. Load the plate into the plate holder in the instrument with the notched A1 position at the top-left of the tray. Ensure that the plate is properly aligned in the holder. 3. Push the tray door to close it. Apply pressure to the right side of the tray door at an angle. Start the run 1. In the navigation pane, select Run. 2. Click Start Run (green button at the top of every run screen). Specify a reason for change, if (Optional) Monitor the run 1. In the navigation pane, select Run. 2. Select a run screen from the navigation pane to monitor the progress: Amplification Plot - View the change in normalized reporter signal (ΔRn) for each cycle. Melt Curve - View the normalized reporter signal (Rn) plotted against temperature ( C). Temperature Plot - View the change in sample and block temperature ( C) throughout the run. Run Method - View the default run method. At the top of every run screen, you can view the run status. Note: During a Mycoplasma SEQ experiment run, progress bars reflect run status. During the third stage of a Mycoplasma SEQ experiment, there is a delay between melting and completion of the stage while the system analyzes the data. Unload the instrument When your 7500 Fast system displays the Run Complete message, unload the reaction plate from the instrument. 1. Push the tray door to open it. 2. Remove the reaction plate. 3. Push the tray door to close it. Step 4: Review the Results Summary Use the Call Summary, Plate Layout and Table views in the Results Summary screen to review the experiment results. 1. From the navigation pane, select Results Results Summary. 2. Review the Call Summary for results: GR2471 Sample Type Call Description GR2477 GR2471 7500 tray top view Push Positive Control, Inhibition Control Expected Unexpected Target detected No target detected (target should be detected) 1 2 3 Negative Control Expected Unexpected No target detected Target detected (no target should be detected) Page 3

Sample Type Call As needed: To review any unexpected or inconclusive results, review the Quality Summary (see below) Export and print the data (see page 5) Sign the results Step 5: (Optional) Review the results Review the Quality Summary Description Unknown Present Target signal is present and is within the temperature range, derivative range, and C T range for the assay. Absent Target signal is not present within the temperature range, derivative range, and C T range for the assay. Inconclusive The AccuSEQ software is unable to determine a result. Use the Quality Summary to review the call assessments applied to wells of the reaction plate and view troubleshooting information. This summary includes the call assessment frequency and location for the open experiment. 1. Click Results in the navigation pane, then click Quality Summary. 2. In the Quality Summary table, look in the Frequency and Wells columns to determine which call assessments appear in the experiment. For Mycoplasma SEQ experiments, the call assessments listed below may be triggered by the experiment data. Unknown DNA in negative control No expected DNA in positive and/or inhibition control Presumptive positive Presumptive negative Unexpected result in inhibition control Sample inhibits amplification High background signal Baseline algorithm failed Thresholding algorithm failed Bad passive reference signal Fluorescence is offscale All positive controls failed All negative controls failed No inhibition control found Unable to determine the SYBR dye call No signal in well C T algorithm failed Exponential algorithm failed 3. (Optional) Click a call assessment in the table to display more information about the assessment and highlight the associated well(s) in the plate layout or table view. As needed: To further investigate any unexpected or inconclusive results, review the following: Amplification Plot (see below) Melt Curve (see page 4) Table data (see page 5) Export and print the data (see page 5) Sign the results Review the amplification plot The amplification plot displays the data collected during the cycling stage of PCR amplification. It can be viewed as: Baseline-corrected normalized reporter (ΔRn) vs. cycle Normalized reporter (Rn) vs. cycle Threshold cycle (C T ) vs. well To review the Amplification Plot: 1. Click Plot Analysis in the navigation pane, then click Amplification Plot. 2. Display all 96 wells in the amplification plot by clicking the upper left corner of the plate layout in the Plate Layout tab. 3. Use the Plot Settings tab to review the amplification plot for: C T values Irregular amplification Outliers Review the melt curve The Melt Curve plot displays the fluorescence peak data collected at each well position during the melt curve stage of an instrument run. For Mycoplasma SEQ experiments, the AccuSEQ software determines the melting temperature (T m ) and reporter signal (T m height) for each peak. To review the Melt Curve: 1. Click Plot Analysis in the navigation pane, then click Melt Curve. IMPORTANT! The T m values displayed below the melt curve correspond to the largest peak in the target range. To determine the target T m, review the table data (see below). The T m values displayed below the plot may not exactly match the values displayed in the table view because of rounding and/or interpolation. 2. Select wells in the plate layout to view in the melt curve plot. Page 4

Review the table data The Table View displays results data for each well in the reaction plate, including: The well number, sample name, sample type, assay, call, call assessment, and cycle 1 fluorescence (FSU) The calculated values: C T, target T m, target T m height, notarget T m, no-target T m height, and ΔRn Note: The cycle 1 fluorescence and ΔRn values are only available for display in the Table View when it is accessed from the Plot Analysis screens. To review the table data: 1. In the navigation pane, select Results or Plot Analysis, then select the Table View tab. 2. Select well(s) in the Table View to display in the corresponding plot(s). 3. Review the following values for wells with inconclusive or unexpected results: Target T m and Target T m height No-target T m and No-target T m height C T Step 6: (Optional) Investigate the results Review multiple plots 1. Click Plot Analysis in the navigation pane, then click Multiple Plots View. 2. Select Multicomponent Plot and Raw Data Plot. 3. Click a sample in the plate layout or the table view to display the corresponding plots. Review the analysis settings Note: You must have administrator or scientist privileges to access this function. The Analysis Settings dialog box displays the pre-defined threshold cycle (C T ) analysis settings for Mycoplasma SEQ experiments, optimized in the AccuSEQ software for use with the MicroSEQ Mycoplasma Real-Time PCR Detection Kit. If the pre-defined analysis settings are not suitable for your experiment, you can change the C T settings in the Analysis Settings dialog box, then reanalyze your experiment. 1. Open an analyzed Mycoplasma SEQ experiment. 2. Select Analysis Analysis Settings from the toolbar menu. 3. Define the C T settings to use for the Mycoplasma target in the table. See the AccuSEQ Software Help for more information. 4. Click Apply Analysis Settings. 5. Click Analyze to reanalyze the data with the new C T settings. Omit wells from the analysis Note: You must have administrator or scientist privileges to access this function. You may omit wells from analysis if you do not want to consider data generated by the well. 1. In the navigation pane, select Plot Analysis. 2. Using the plate layout or table view, select one or more wells to omit from analysis. 3. Right-click the well(s), then select Omit. Results for the selected well(s) are removed. 4. Click Analyze to reanalyze the data without the omitted well(s). Step 7: (Optional) Export and print the data Export data Note: You must have administrator or scientist privileges to access this function. 1. In the toolbar of an analyzed Mycoplasma SEQ experiment, click Export. 2. Complete the tasks on the Export Properties tab: a. Select the Mycoplasma SEQ data to export: Sample Setup Results Raw Data Amplification Data Multicomponent Data b. Select to export all data in one file or in separate files for each data type. c. Enter export file properties, then click Start Export. 3. Click to close the Export Data dialog box. Page 5

Print a report 1. In the toolbar of an analyzed Mycoplasma SEQ experiment, click Print Report. 2. Select the Mycoplasma SEQ data to include in the report: Experiment Summary Results Summary Plate Layout Amplification Plot (ΔRn vs. Cycle, Rn vs. Cycle, C T vs. Well) Melt Curve (Derivative Reporter, Normalized Reporter) Quality Summary 3. Click Preview, Save As PDF (or HTML), or Print. 4. Click to close the Print Report dialog box. Print SAE reports You can print SAE reports for the current experiment in the Experiment screen: Audit Report or E-Sig Report. For more information, see the AccuSEQ Software Help. For Research Use Only. Not for use in diagnostic procedures. NOTICE TO PURCHASER: PLEASE REFER TO THE ACCUSEQ REAL-TIME PCR DETECTION SOFTWARE MYCOPLASMA SEQ EXPERIMENTS GETTING STARTED GUIDE FOR LIMITED LABEL LICENSE OR DISCLAIMER INFORMATION. Trademarks of Applied Biosystems and its affiliated companies include: Applied Biosystems, AB (Design), AccuSEQ, and MicroSEQ. SYBR is a registered trademark of Molecular Probes, Inc. All other trademarks are the sole property of their respective owners. Copyright 2009, Applied Biosystems. All rights reserved. Part Number 4425586 Rev. A 08/2009 Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.345.5224 www.appliedbiosystems.com International Sales For our office locations please call the division headquarters or refer to our Web site at www.appliedbiosystems.com/about/offices.cfm