Element Condition Values

Similar documents
MICHIGAN DEPARTMENT OF TRANSPORTATION

BRIDGE INSPECTION REPORT

BRIDGE INSPECTION REPORT

HistoricBridges.org - National Bridge Inventory Data Sheet

Ontario Structure Inspection Manual Inspection Form Structure Number: 12

AGENDA AGENDA. Route 15/29 SBL Bridge Superstructure Replacement & Widening. NOVA District. Bridge Views SCOPE. Existing Structure.

Chapter 4 Bridge Program Drawings

LRFD Bridge Design Manual Changes

Bridge Replacement Study (Phase 1)

JULY 2016 LRFD BRIDGE DESIGN 11-1

Alberta Transportation Bridge Inspection & Maintenance System (Web 2005) N-1 Bridge. Bridge Inspection Form Type Lot No. 2

Guidelines for Checking Final Design Bridge Plans

Minnesota Department of Transportation (MnDOT) Local Historic Bridge Report

ODOT District Bridge General Notes B405: OBJECT MARKERS AND STRUCTURE/CULVERT IDENTIFICATION SIGNS

!"#$ % 1( =4+0(1*0)4 A)*.(.)44)4 8(: 4 0, 2(3*05. Page 1A of 10 11

BRIDGE PREVENTIVE MAINTENANCE STRATEGY FOR ERIE-NIAGARA LOCAL BRIDGE OWNERS

BRIDGE CONSTRUCTION USING SELF-PROPELLED MODULAR TRANSPORTERS (SPMT)

Alberta Bridge Inventory STANDARD BRIDGE & CULVERT COMPONENTS. Standard Bridges. Typical Bridge Components. In Alberta there are about 13,300 bridges.

Structural - Engineering Review Checklist

Parapet/railing terminal walls shall be located on the superstructure.

Table of Contents. July

Session 2: Basic Load Rating Calculations

CHAPTER 12 MICHIGAN DESIGN MANUAL BRIDGE DESIGN REHABILITATION PROJECTS REHABILITATION PROJECTS SCOPE OF REHABILITATION PROJECTS

US 278 East Bound and West Bound. MacKay Creek and Skull Creek. Cursory Above Water and Underwater Investigation Of. Over

JANUARY 4, 2017 AT 2:00 P.M. (EASTERN. (Estimated Cost: $4,600,000) Bids J D WILLIAMSON CONSTRUCTION CO INC $3,799,476.25

FRACTURE CRITICAL BRIDGE INSPECTION

MANUAL OF THE STRUCTURE AND BRIDGE DIVISION

Well Road Project Accelerated Bridge Construction Using Self-Propelled Modular Transporters (SPMT s) By: Mark Bucci, P.E.

ODOT Manual of Bridge Inspection 2014 v8. Element Level (Condition States) Field Manual (Chapters 7 & 9)

Critical Structures Construction Issues

PENNDOT e-notification

MIDAS Training Series

BRIDGE INSPECTION REPORTS 101. Protecting Your Bridge Inventory for the Future Jason Kelly, PE

NORFOLK SOUTHERN CORPORATION UNDERPASS GRADE SEPARATION DESIGN CRITERIA

BRADD Software Executive Summary

In Service Replacement of Box Girder Bottom Slab

AUGUST 2016 LRFD BRIDGE DESIGN 3-1

LRFD BRIDGE MANUAL PART II: STANDARD DETAILS CONVENTIONAL CONSTRUCTION DRAWING NUMBER, DESCRIPTION, DATE OF ISSUE

BRIDGE DESIGN MANUAL UPDATES. Jamie F. Farris, P.E.

Design and Rating of Steel Bridges

Bids JANUARY 25, 2017 AT 2:00 P.M. (EASTERN TIME) (Estimated Cost: $3,600,000)

Alder Drive / Blair Road Bridge Replacement Projects

Inventory Inspection and Load Rating of a Complex Segmental Concrete Bridge. Presented by Matthew J. Lengyel, PE, SE

Alligator Cracking. Light. Medium. High

Barriers, Parapets, and Railings

Title Page: Modeling & Load Rating of Two Bridges Designed with AASHTO and Florida I-Beam Girders

Implementing Asset Management: WSDOT s Experience

Designing Bridges for Inspectability

1/26/2015 DETAILS CIP DETAIL EXAMPLES WHY SIMPLIFY DETAILS? CIP DETAIL EXAMPLES DETAILING FOR SIMPLICITY

Bridges. Chapter 6: chapter contents

JULY 2014 LRFD BRIDGE DESIGN 5-1

Designer Supplement: AS-2-15 Approach Slab Installation January 16, 2015

Bijan Khaleghi, Ph, D. P.E., S.E.

Introduction to Decks and Deck Systems

Design and Construction of Concrete Overlays. By: James K. Cable, P.E. Cable Concrete Consultation

Superstructure Guidelines

National Bridge Inspection Program Risk-based, Data-driven FHWA Oversight

A Case Study of a Computer Aided Structural Design of a System Interchange Bridge

Design and Construction of the SH58 Ramp A Flyover Bridge over IH70. Gregg A. Reese, PE, CE, Summit Engineering Group, Inc.

Procedure No: (SP) Effective: August 28, 2002 Responsible Office: Division of Finance and Forecasting INFRASTRUCTURE CAPITALIZATION PROCEDURE

STRUCTURE AND BRIDGE DIVISION

A STRUCTURAL ASSESSMENT STUDY ON THE SUSTAINABILITY OF SULTAN ISKANDAR BRIDGE KUALA KANGSAR PERAK MALAYSIA

AASHTOWare BrR 6.8 Steel Tutorial Steel Plate Girder Using LRFR Engine

Continuous for Live Load: A Texas Historical Perspective

ODOT Design & Construction Requirements for MSE Walls

Bridge Development Update

SMS. Structure Management System. Structure Inventory Coding Guide STRUCTURE MANAGEMENT SYSTEM (SMS) ORC , ,

Proposed Modifications to the LRFD Design of U-Beam Bearings

SIBLEY POND DESIGN-BUILD BRIDGE REPLACEMENT PROJECT ROUTE 2, CANAAN/PITTSFIELD, MAINE

Deck Joints and Bearings

DECEMBER 2017 LRFD BRIDGE DESIGN 2-1

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO. 55J11 TWP 197 (70 TH AVE NW) OVER A STREAM DISTRICT 6 OLMSTED COUNTY

MAINE TURNPIKE AUTHORITY ADDENDUM NO. 1 CONTRACT EXIT 103 SOUTHBOUND UNDERPASS BRIDGE REHABILITATION MILE 103.0

MICHIGAN DESIGN MANUAL BRIDGE DESIGN - CHAPTER 7: LRFD CHAPTER 7 - LRFD DESIGN CRITERIA - NEW AND RECONSTRUCTION PROJECTS

Prestressed Concrete Structure Tutorial

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Appendix D.2. Redundancy Analysis of Prestressed Box Girder Superstructures under Vertical Loads

Slab Bridge Designer 2.1 Help: Example Analysis

Bonner Bridge Replacement Update:

BrD Superstructure Tutorial

MICHIGAN DEPARTMENT OF TRANSPORTATION BRIDGE DESIGN GUIDES. Engineering Manual Preamble

EXISTING ROADWAY CONDITION ASSESSMENT REPORT (ERCAR) SAMPLE OUTLINE

CONTINUOUSLY REINFORCED CONCRETE AND UNPAVED ROADS CONDITION SURVEY FIELD MANUAL PUBLICATION 343 APRIL 2017 PUB 343 (4-17)

2008 Bridge Load Rating Class 101

SHRP2 SOLUTONS. Innovative Bridge Designs for Rapid Renewal. Peer-to-Peer Exchange Workshop Atlanta, GA November 2015

Ironton Russell Bridge Project

The Chief Estimator Software. Item Cost Summary Bridge & Overpass Projects

Preserva on Assessment

ROADSIDE SAFETY BARRIER ELEMENTS Module 3

AASHTOWare Bridge Rating/DesignTraining. STL9 Curved Steel 3D Example (BrR/BrD 6.5)

I-35W Retaining Wall Design Exhibit A - Draft Scope of Work

CHAPTER 4 GRADE SEPARATIONS AND INTERCHANGES

I-74 Corridor in the Quad Cities A State of the Art Design

ESTIMATE OF QUANTITIES

MASTER AGREEMENT FOR BRIDGE DESIGN SERVICES SCOPE OF WORK

Scott Neubauer. Bridge Maintenance and Inspection Engineer Office of Bridges and Structures Iowa DOT

General Information for Joints

GEOMETRIC DESIGN CRITERIA for Non-freeway Resurfacing, Restoration, and Rehabilitation Projects

Sponsored by the Iowa Department of Transportation and the Iowa Highway Research Board Iowa DOT Project HR-393 JUNE 1998 CTRE

Transcription:

Element Condition Values Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV Inspection Date Elem/Env Element Description Quantity UOM Qty1 Qty2 Qty3 Qty4 012- / 2 Reinforced Concrete Deck/Slab 44892 sq ft 0 0 44892 38 With the exception of Bays 10 and 16, the underside of the deck is not visible due to steel stay in place forms. - Deck exhibits longitudinal, transverse, and pattern cracking to 1/32" wide throughout spaced at less than 12" (Photo 5). The cracking appears to be reflective of the top mat of rebar and may indicate corrosion and lack of adequate cover. - Northbound Lane 3 exhibits a 45' L x 3' W patch as well as several smaller patches throughout. Patching may confirm or be indicative of corrosion initiation. - D-cracking and edge spalls exist along construction joints. - Deck overhang soffits and Bays 10 and 16 soffits exhibit transverse cracks to 1/64" wide, most with light efflorescence. - Longitudinal joint between Girders 10 and 11 exhibits signs of leakage. 107 / 2 Steel Open Girder/Beam 6323 ft 6323 Twenty-two girder lines. - Bottom flanges of girders exhibit isolated areas of pigeon guano accumulation. - Various portions of girders have been re-coated. - Bottom flange of Girders 1 through 3 of Span 2, as well as 21 and 22 of Span 3 exhibit minor impact scrapes from high profile vehicles. Minimum clearance measured was 15'-10" at scrapes. 205 / 2 Reinforced Concrete Column/Pile Extension - No significant deficiencies. 27 each 27 215 / 2 Reinforced Concrete Abutment 368 ft 368 - Backwalls exhibit minor vertical cracks to 1/64" wide with light efflorescence at a few girder bearings. - Cold joint at abutment seat exhibits a 1/64" wide crack with efflorescence and water staining between Girders 4 and 5 at Abutment 2. 234 / 2 Reinforced Concrete Pier Cap 553 ft 553 - No significant deficiencies. 300 / 2 Strip Seal Expansion Joint 368 ft 0 368 - Expansion joints exhibit dirt and debris accumulation throughout. - Joint headers exhibit transverse cracking up to 1/64" wide. 310 / 2 Elastomeric Bearing 110 each 109 1 - Bearing anchor bolts at Girder 12, Pier 1 exhibit missing nuts (Photo 6). 321 / 2 Reinforced Concrete Approach Slab 2 each 0 0 2 - Approach slabs exhibit transverse and diagonal cracking to 1/32" wide spaced at less than 12" (Photo 7). - Approach slabs exhibit isolated patched areas, some are starting to spall and crack. 331 / 2 Reinforced Concrete Bridge Railing 1150 ft 1115 35 Quantities include a section of temporary jersey barrier placed in front of bridge rail on east side of northbound. - Parapets exhibit vertical cracks to 1/32" wide and tire scuff marks at random locations. - Repair at northwest corner over Abutment 2 exhibits a 1.5' W x 1' L x 4" D spall and 5' of delamination/incipient

Element Condition Values Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV Inspection Date Elem/Env Element Description Quantity UOM Qty1 Qty2 Qty3 Qty4 - Repair at northwest corner over Abutment 2 exhibits a 1.5' W x 1' L x 4" D spall and 5' of delamination/incipient spalling and associated cracking adjacent to spall (Photo 8). - Temporary jersey barriers along the east shoulder of the northbound deck and approach exhibit impact related misalignment. 515 / 2 Steel Protective Coating 7758 ft 7758 - No significant deficiencies. 516 / 2 Concrete Coating 1 lump sum - No significant deficiencies. 1 646 / 2 Under Deck Lighting System 12 each 10 0 2 - Pier 2 exhibits one light not functioning on the north face, east end. - Pier 3 exhibits one light not functioning on the south face, center. 650 / 2 Utilities 1 each 1 Two 6" conduits bundled and attached to deck soffit in Bay 21. - No significant deficiencies. 660 / 2 Steel Diaphragms 204 each 204 - Diaphragms exhibit minor pigeon guano accumulation throughout. 680 / 2 Reinforced Concrete Retaining Walls 100 ft 100 - Retaining walls exhibit isolated vertical cracks up to 1/62" wide. 685 / 2 Concrete Abutment Slope Paving 2 each 0 2 - The panel below Girders 21-22 exhibits a 12" high x full width section adjacent to Abutment 1 that has broken off and settled 1" (Photo 9). - Slope paving adjacent to northeast wingwall exhibits 2" settlement and undermining. 690 / 2 Substructure Scour and Erosion 5 each 5 694 / 2 Debris on Seats 5 each 0 5 - Minor pigeon guano accumulating on pier caps (Photo 10). 761 / 2 Reinforced Concrete Approach Barrier Rail 6 each 6 - Approach rail exhibits random hairline vertical cracks. 770 / 2 Cement Concrete Approach Pavement 1 lump sum 0 1 - North approach pavement exhibits cracks up to 1/32" wide. - South approach pavement exhibits isolated longitudinal and transverse cracks to 1/64" wide. 771 / 2 Asphalt Concrete Approach Pavement 1 lump sum 1

Element Condition Values Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV Inspection Date Elem/Env Element Description Quantity UOM Qty1 Qty2 Qty3 Qty4 -Asphalt approach pavement exhibits transverse cracks to 1/4" wide. Cracks are probably reflective of overlaid concrete panels. 775 / 2 Approach Roadway Embankment 1 lump sum - No significant deficiencies. 1

State of Nevada Department of Transportation Photo 1: East elevation Photo 2: South approach, northbound

State of Nevada Department of Transportation Photo 3: South approach, southbound Photo 4: South general

State of Nevada Department of Transportation Photo 5: Cracking in the deck surface Photo 6: Missing nuts at Bearing 12, Pier 1

State of Nevada Department of Transportation Photo 7: Cracking in the approach slabs Photo 8: Spalled patch in outboard fascia of the west bridge rail over Abutment 2

State of Nevada Department of Transportation Photo 9: Cracked and settled slope paving at southwest adjacent to Abutment 1 breastwall Photo 10: Bird guano and debris on bearings at piers

Signs and Utilities Report Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV Inspection Date Sign Number & Location on Bridge Anchor Bolts/ Attachment Displacement Sign Frame Deficient Yes* No Yes* No Sign Frame Assembly Deficient Yes* No Catwalk Deficient Yes* No Luminaire Deficient Yes* No Utility Number & Location on Bridge 1 Two 6" conduits bundled and attached to deck soffit in Bay 21 Anchorage Utility Displacement Deficient Yes* No Yes* No Utility Supports Deficient Yes* No X X X Note: Please refer to Element Level Inspection for commentary

Maintenance Inspection Work Items and Costs Report Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV 2 - Perform action with next 1 year Timing Criticality Item Code Description Units 2 Inspection Date Std.Unit Cost Quantity Unit Cost Total Cost Repair/Maintain 1 - Minor D36 LS -- 1 0 0 Utility/Utility Supports 2 Repair inoperable under deck lights at Piers 2 and 3. 1 - Minor D9 Clean Expansion Joints EACH 250 2 250 500 - Clean expansion joints. 3 - Perform action within next 2 years Timing Criticality Item Code Description Units 3 Std.Unit Cost Quantity Unit Cost Total Cost Seal Deck/Slab Cracks 1 - Minor D10 SQFT 1 51000 1 51000 (Pourable Sealant) 3 3 - Seal cracks in deck and approach slabs. Seal Crack in Approach 1 - Minor R18 SQFT 1 6000 1 6000 Slab (Pourable Sealant) - Seal cracks in approach slabs. Patch Spalls in Concrete 1 - Minor D34 SQFT 75 9 75 675 Bridge Railing - Remove and repair failing patch along exterior of northwest bridge rail. 4 - Perform action when time and money permit Timing Criticality Item Code Description Units 4 Std.Unit Cost Quantity Unit Cost Total Cost Clean Debris from 1 - Minor Sub20 LS -- 1 0 0 Abutment/Pier Seat 4 - Clean bird guano on abutment seats, pier caps, and the bottom flange of girders to mitigate deterioration of protective coating. Install Portable Concrete 1 - Minor R30 LINFT 50 50 50 2500 Barrier Rail - Properly align pinned-together temporary jersey barriers along northbound east shoulder.

Maintenance Inspection Work Items and Costs Report Bridge Number I 837 Bridge Location I 15 Over SR589 SAHARA AV Inspection Date 4 4 1 - Minor Super5 Replace/Tighten Anchor Bolt Nuts in Bearing Assemblies EACH 10 2 10 20 - Replace missing Pier 1 bearing anchor nuts for Girder 12 at Pier 1. 1 - Minor Sub5 Repair Spalled Concrete Slope Paving SQFT 38 20 38 760 - Repair cracking and settlement of the slope paving at the southeast and northeast.

[REV. 7/01] LOCAL NAME TYPE LENGTH ft-in 290'-10.5" Sahara Avenue Interchange WIDTH ft-in BRIDGE LOAD RATING State of Nevada Department of Transportation Load Rating Report Four span continuous rolled steel 156'-3.25" STRUCTURE NUMBER I-837 YEAR CONSTRUCTED DEPTH ft-in 2001 3'-10" CONTRACT NUMBER(S) 3003 COUNTY ROUTE DISTRICT MILEPOST Clark I 15 ANALYSIS BY: D. Howell / CH2M HILL DATE: 3/17/2007 CHECKED BY: P. Baxter / CH2M HILL DATE: 3/29/2007 1 40.55 Method of Analysis: BRASS (Bridge Rating and Analysis of Structural Systems) version 5 release 9.4 A.) Existing Condition With existing Rating By Load Factor Method 0 inch overlay INVENTORY RATING = HS 45.4 = 74.1 Metric Tons OPERATING RATING = HS 75.8 = 123.8 Metric Tons PERMIT TRUCK COLOR CAPACITY = PPPPP B.) Modified Condition With future Rating By Load Factor Method inch AC Overlay INVENTORY RATING = HS --- = ---- Metric Tons OPERATING RATING = HS --- = ---- Metric Tons PERMIT TRUCK COLOR CAPACITY = CONDITION RATING Date of Inspection: COMMENTS: MIN. VERTICAL CLEARANCE 2/10/2005 15 Feet [Summarized from the Structure Inspection Report] Type: Routine 9 Inches DECK RATING: SUPERSTRUCTURE RATING: 7 8 CHANNEL RATING: ---- SUBSTRUCTURE RATING: 7 EST. REMAINING LIFE [Years]: 47 CULVERT RATING: NA STRUCTURE POSTED? [Yes/No]: No Note: Ratings above are NBI Ratings from inspection report weighted for structural items only Seal and Signature This report was prepared in accordance with AASHTO "Manual for Condition Evaluation of Bridges, 1994 Second Edition" with revisions by Nevada Department of Transportation. Report by: D. Howell / CH2M HILL DATE: 3/17/2007

[REV. 8/05] State of Nevada DATE Department of Transportation 3/17/2007 Load Rating Summary Sheet LOCAL NAME STRUCTURE NUMBER Sahara Avenue Interchange I-837 COUNTY Clark ROUTE I 15 MATERIAL PROPERTIES: BRIDGE DATA Deck/---- Girders/ ---- Original Bridge: Concrete F'c (psi)= 4000 --- Four span continuous rolled steel Reinforcing Steel Fy (psi)= 60000 --- Structural Steel Fy (psi)= --- 50000 Widenings: Prestressing Steel F's (psi) --- --- None --- --- ANALYSIS CRITERIA: - Rating performed using LFD - Analyzed structure under "existing" conditions - Alternate analysis not using X-bracing schedule - NDOT load rating criteria, rail, and applicable median and luminaire DL distributed to 2 outside girders - Bridge is supported on bearings at each bent - Misc. DL=10%(girder DL) to include connections, stiffeners, x-frames - CA permit trucks modeled w/ 26k front axle & 48k axles @ 18' - F'c=4000psi & Fy=60 ksi for concrete deck, Fy=50 ksi for girder steel - Skew effects were not taken into account in rating ANALYSIS METHOD & RESULTS: Rating Method Loads Deck Analysis by: D. Howell / CH2M HILL 3/17/2007 Checked by: P. Baxter / CH2M HILL 3/29/2007 Girders BRASS (Bridge Rating and Analysis of Structural Systems) version 5 release 9.4 Special Items - NA HS20 = AASHTO HS20-44 Truck Load or Lane Load whichever is greatest P5/P9/P13 = Caltrans permit trucks P5, P9, and P13 applied separately with same wheel lines per girder as for HS20 INVENTORY RATING = HS 45.4 = 74.1 Metric Tons OPERATING RATING = HS 75.8 = 123.8 Metric Tons Rating Factors for P5 / P7/ P9/ P11/ P13 = 2.47/2.21/1.94/1.91/1.87 Rating for P7 and P11 interpolated LOAD RATING- Existing Condition Overlays- 0 inch overlay Standard Rating Items Controlling Girder Action Special Rating Items INVENTORY RATING: Deck Girders Analysis Point Critical Action Rating Item/ Action RATING FACTOR for HS20 = 2.27 G12 205 Flexure NA NA OPERATING RATING: RATING FACTOR for HS20 = 3.79 G12 205 Flexure NA NA RATING FACTOR for P5 = 2.47 G12 205 Flexure NA NA RATING FACTOR for P9 = 1.94 G12 205 Flexure NA NA RATING FACTOR for P13 = 1.87 G12 200 Serviceability NA NA LOAD RATING- w/ Modified Condition Overlays- Standard Rating Items Controlling Girder Action Special Rating Items INVENTORY RATING: Deck Girders Analysis Point Critical Action Rating Item/ Action RATING FACTOR for HS20 = OPERATING RATING: RATING FACTOR for HS20 = RATING FACTOR for P5 = RATING FACTOR for P9 = RATING FACTOR for P13 = INVENTORY RATING = HS --- = --- Metric Tons OPERATING RATING = HS --- = --- Metric Tons Rating Factors for P5 / P7/ P9/ P11/ P13 = -.-- / -.-- /-.-- /-.-- /-.--

Last Modified: 05/12/2014 Structure Inventory and Appraisal 1. State Code 329 (Nevada) 2. District 01 (District 01) 3. County 003 (Clark) 4. Place Code 40000 (Las Vegas) 5. Inventory Route 111000150 6. Feature Intersected SR589 SAHARA AV 7. Facility Carried I 15 8. Structure No. I 837 9. Location LAS VEGAS 10. Min Vertical Clearance 99.99 ft. 11. Milepoint 40.551 12. Base Hwy Network 1 (Inventory Route is on the Base Network) 13A. LRS Inv Route 0000000015 13B. Subroute No. 16. Latitude 17. Longitude 19. Detour Length 36 8 ' 38.7 " 115 10 ' 15.77 " 20. Toll 3 (On Free Road) 21. Maintenance Resp 01 (State Highway Agency) 22. Owner 01 (State Highway Agency) 32. Appr. Roadway Width 33. Median 00 26. Functional Class 11 (Urban) 27. Year Built 2001 28A. Lanes On 9 28B. Lanes Under 10 29. Avg Daily Traffic 260000 30. Year of ADT 2012 31. Design Load 6 (MS 18+Mod / HS 20+Mod) 3 (Closed median with non-mountable barriers) 34. Skew 32 degrees 35. Structure Flared 0 36A. Bridge Railings 1 (Meets acceptable standards) 36B. Transitions 1 (Meets acceptable standards) 36C. Approach Guardrail 1 (Meets acceptable standards) 36D. Approach GuardRail Term 1 (Meets acceptable standards) 0.6 150.9 ft. 37. Historical Significance 5 (Not eligible) 38. Navigation Control N (Not applicable, no waterway) 39. Vertical Clearance 0.0 ft. 40. Horiz. Clearance 0.0 ft. 41. Posting Status A (Open) 42A. Type of Service On 1 (Highway) 42B. Type of Service Under 1 (Highway, with or w/out pedestrian) 43A. Main Span Material 4 (Steel continuous) 43B. Main Span Design 02 (Stringer/Multi-beam or Girder) 44A. Appr. Span Material 0 (Other) 44B. Appr. Span Design 00 (Other) 45. No. of Spans Main Unit 4 46. No. of Appr. Spans 0 47. Horiz. Clearance 81.3 ft. 48. Length Max Span 95.8 ft. 49. Structure Length 287.4 ft. 50. Curb/Sdwk Width LT 0.00 ft. RT 0.00 ft. 51. Width Curb to Curb 150.9 ft. 52. Deck Width Out to Out 156.2 ft. 53. Min. Vert. Clearance Over 328 ft. 54A. Min. Vert. Underclear H (Highway beneath structure) 54B. Min. Vert. Underclear 15.8 ft. 55A. Min. Lat. Underclear Right H (Highway beneath structure) 55B. Min. Lat. Underclear Right 5.9 ft. 56. Min. Lat. Underclear Left 3.9 ft. 58. Deck 5 (Fair Condition (minor section loss)) 59. Superstructure 7 (Good Condition (some minor problems)) 60. Substructure 7 (Good Condition (some minor problems)) 63. Rating Method 1 (Load Factor (LF)) 64. Operating Rating 99.8 65. Rating Method 1 (Load Factor (LF)) 66. Inventory Rating 81.7 67. Struc Eval 7 (Better than present minimum criteria) 68. Deck Geometry 9 (Superior to present desirable criteria) 69. Underclearance, 4 (Meets minimum tolerable limits) Vert & Horiz 70. Posting 5 (Equal to or above legal loads) 71. Waterway Adequacy N (Not Applicable) 72. Approach Alignment 8 (Equal to present desirable criteria) 75A. Type Of Work 75B. Work Done By 76. Len of Struc Impr 0.0000 ft. 90. Inspection Date 91. Frequency 24 92A. FC Frequency 92B. UW Frequebcy 92C. SI Frequency 92A-1. FC Required N 92B-1. UW Required N 92C-1. SI Required N 93A. FC Inspection Date 93B. UW Inspection Date 93C. SI Date 94. Bridge Impr Cost $ 0 95. Rdwy Impr Cost $ 0 96. Total Proj Cost $ 0 97. Year of Impr Cost 98A. Border Bridge Code (Not Applicable) 98B. % Responsibility 99. Border Bridge No. 100. STRAHNET 1 (Is on an Interstate STRAHNET route) 101. Parallel Structure N (No parallel structure) 102. Direction of Traffic 2 (2-way traffic) 103. Temp Structure 104. Hwy Sys Inv Route 1 (Structure/Route is on NHS) 105. Fed Lands Hwys 0 (Not Applicable) 106. Year Reconstructed 107. Deck Type 1 (Concrete Cast-in-Place) 108A. Wearing Surface 1 (Monolithic Concrete (concurrently placed with structural deck)) 108B. Deck Membrane 0 (None) 108C. Deck Protection 0 (None) 109. Truck ADT 7 % 110. Desig National Net 1 (Inventory route on National Truck Network) 111. Pier Protection 112. Bridge Length Y 113. Scour Critical Bridges N (Not over waterway) 114. Future ADT 230000 115. Year Future ADT 2031 116. Min Nav Vert Clear 0 ft. 201. Contract Number 202. Seismic Risk 203. Structure Name 204. Culvert Barrel Height 205. Culvert Barrel Width 206. Culvert Barrel Length 207. Total Deck Area 44892 sq ft. 208. Last Access Required Inspection Date 209. Access Required 48 Inspection Frequency 210. Date of Next Access 02/10/2019 Required 211. Bridge Inventory South to North Direction 61. Channel/Channel Prot N (Not Applicable) 62. Culvert N (Not Applicable) Sufficiency Rating: 82.40 FO: N SD: N