Public Notice New BC Building Code Requirements

Similar documents
Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

2010 National Building Code Adoption and Associated Process Changes

Feature Zone IECC 2009 IECC

IRC 2012 Key Changes

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Boulder City NV Prepared by (Print Name) Signature Date

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Michigan Energy Code Training and Implementation Program

Plan Check & Field Inspection Guide

Construction Report NYSERDA Residential Performance Challenge

Hardin County Planning and Development Commission

Chapter 2: Foundation

ASHRAE 62.2: What s New in 2016

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Questar ThermWise Duct Technical Specifications

1) For the purpose of this Section, the term common space shall mean all spaces required to

2012 IECC Residential with State Adopted Changes

Advanced Ventilation for Residential applications FBC Res 2010.

Compliance Certificate

Energy Efficiency Programs

BUILDING PERMIT APPLICATION

New Hampshire Residential Energy Code

Montana Homebuilder Brief: Residential Energy Code 1

Training Certification Categories

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

National Building Code Part 9 Energy Efficiency: Focus Paper to Assist in the Review of Proposed Changes

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

IECC Commercial Significant Changes Summary Tier I

Radon Vent Pipe System. Labeling Performance Indicators

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

BC BUILDING CODE ERRATA

Chapter 1: Compliance

Home Energy Assessment Rebate Guide

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Inspection of New One- and Two- Family Dwellings

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Oregon High Performance Home Requirements

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

Administrative Changes

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Michigan Energy Code Training and Implementation Program

Homes. Plan Review Input Form. Office Use: P l an Rev iew Contro l Nu mb er

One and Two Family Additions

Basement Renovation Guide For Residential Dwellings

Module number 6 provides an on-line, self-paced training seminar on energy efficiency and energy conservation for residential buildings.

Connecticut 2011 Baseline Study of Single-Family Residential New Construction. Final Report

Low-Income Energy Savings Program. Program Guidelines

RESIDENTIAL ENERGY EFFICIENCY

Vermont Residential Building Energy Code. Handbook. A Guide to Complying with Vermont s Residential Building Energy Standards (30 V.S.A.

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

NCAT. Energy Code Evolution

ALASKA ENERGY BUILDING STANDARD EFFICIENCY

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

The Inspection Process. Waxhaw N.C.

HOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL

INTERIOR ENVIRONMENT

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

2012 CLEAResult All rights reserved. Residential Energy Efficiency

BUILDING ENERGY CODES UNIVERSITY

Building & Fire Appeals Board

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Ontario s Building Code

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Table of Contents. Page Title

If you are choosing a limited glazing area prescriptive option, completing the Glazing Schedule will be the first task.

ENERGY STAR for New Homes: Technical Specification - Ontario January 2011, revised September 2011

CHECKLIST Inspecting a Garage

Crawl Space Moisture Control

HPW Protocol Reference Manual

California HERO Program Residential Eligible Product List All Products

Radon Control Methods for Existing and New Residential Structures

Personal: Residential Grant Table for ecoenergy Retrofit

Core Building Advances: Introduction to Sustainable Building & Building Science

Florida HERO Program Residential Eligible Product List All Products

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

This page has been left blank intentionally.

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

2012 Fiscal Impact International Mechanical Code

Building Enclosure & Energy Performance of Log & Timber Homes

Vermont Residential Building Energy Code. Handbook

RESIDENTIAL BUILDING PLAN REQUIREMENTS

2006 INTERNATIONAL ENERGY CONSERVATION CODE

fort collins building & zoning

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

Home Energy Savings Program. Utah Participating Weatherization Trade Ally Program Manual

Transcription:

Public Notice New BC Building Code Requirements November 27, 2014 The City of Revelstoke Chief Building Official advises that as of December 19, 2014 a number of new BC Building Code requirements will take effect. A Provincial Informa on Bulle n outlining the five groups of changes is a ached for reference. Please note, any Building Permit Applica on received a er December 18, 2014 must comply with the new BC Building Code requirements. Within the Building Code changes are changes to 9.36 and 9.32. The Building Officials Associa on of Bri sh Columbia (BOABC) delivered an educa on seminar on these changes November 14, 2014 in Kelowna. Following this session the Zone Director (City of Kelowna Building Official) provided addi onal interpreta on guidance on the changes. A ached is also a copy of the City of Kelowna interpreta on for reference. Please note Kelowna is Zone 5, we in Revelstoke are Zone 6. The City of Revelstoke Chief Building Official con nues to work with Building Officials Associa on of BC on the interpreta on of the changes. As addi onal informa on becomes available supplemental no ces will be provided. If you have any ques ons or concerns please contact the Development Services Department at 250 837 3637 or development@revelstoke.ca. City of Revelstoke PO Box 170 Revelstoke, BC V0E 2S0 revelstoke.ca

Information Bulletin Building and Safety Standards Branch PO Box 9844 Stn Prov Govt Victoria BC V8W 9T2 Email: building.safety@gov.bc.ca Website: www.housing.gov.bc.ca/building No. B14-02 September 17, 2014 What s New? Updates to the BC Building Code Effective December 19, 2014 In July and September 2014, two Minister s Orders were signed updating the 2012 BC Building Code. These updates consist primarily of revisions already adopted by the model National Building Code that need to be adopted into the 2012 BC Building Code. In addition, several B.C. variations are included. Bulletins B14-03 through B14-07 provide some background for each of the B.C. specific changes. Some background is also provided for significant changes to the National Building Code that are being adopted into the BC Building Code. The first bulletin (B14-03) outlines miscellaneous changes and explains adjustments to selected National Building Code revisions. The other four bulletins each outline changes related to specific topics: daycare facilities, ventilation, rainscreen assemblies and radon. On December 19, 2014 these new requirements for the BC Building Code will come into effect. Below is a brief description of each bulletin. B14-03: Miscellaneous Changes This bulletin outlines miscellaneous code changes, lists errata and clarifies the intent of some requirements. B14-04: Daycare Facilities The requirements for infant daycares in the 2012 BC Building Code was unclear, which led to inconsistent interpretation amongst local governments. This bulletin explains changes to achieve consistent and acceptable levels of building safety for infant daycare facilities. The new code clarifies small wood-frame buildings (A2) as an acceptable building type for daycares and that those requirements will apply regardless of the age of the children. In addition, there are further requirements where 1 or more infants are accommodated (an infant is any child under the age of 30 months). All other applicable requirements of the BC Building Code must still be followed. The changes allow for more building options for daycare providers while maintaining an acceptable level of safety. B14-05: 9.32. Ventilation This bulletin introduces new requirements for the ventilation of residential dwelling units, such as: houses, apartments and secondary suites. Instead of relying solely on uncontrolled air infiltration to supply fresh air, these new requirements are designed to ensure adequate ventilation by helping to improve airflow in dwelling units. By requiring an exhaust fan as well as ducted supply air, fresh air will be continuously distributed to every bedroom and exhausted continuously from a principle exhaust fan. The contents of this Bulletin are not intended to be provided as legal advice and should not be relied upon as legal advice. For further information contact the Building & Safety Standards Branch. 1

Information Bulletin Building and Safety Standards Branch PO Box 9844 Stn Prov Govt Victoria BC V8W 9T2 Email: building.safety@gov.bc.ca Website: www.housing.gov.bc.ca/building B14-06: Calculating the Effective Thermal Resistance of Rainscreen Wall Assemblies This bulletin clarifies how to calculate the thermal performance of rainscreen assemblies. The appendix to Section 9.36. Energy Efficiency does not provide sufficient information to calculate the performance of these common assemblies, and this bulletin provides code users with the required information to apply Section 9.36. to these assemblies. The Homeowner Protection Office has also created educational, illustrated guides to help explain the new energy efficiency requirements for houses in BC. The guides can be found here: http://www.hpo.bc.ca/energy-efficiencyrequirements. B14-07: New Radon Rough-in Requirements Radon gas is an odourless, colourless and tasteless, naturally occurring radioactive substance produced by the decay of uranium in soil and rocks. Previously, British Columbians living in areas with a known elevated risk of radon were required to install a capped rough-in in preparation for the future installation of a radon mitigation system. The Province is now changing the roughin requirements for future radon mitigation to include a radon vent pipe that extends to the outside (through the roof or wall of the home) in areas known to have elevated indoor concentrations of radon. All changes to the BC Building Code are adopted by Ministerial Order and can be found here: http://www.housing.gov.bc.ca/building/code/revisions.htm. The online version of the code will be updated on December 19, 2014 to reflect all the changes in the Minister s Orders. Registered purchasers of paper codes will receive email notification containing replacement pages which may be printed and inserted into existing code binders. The contents of this Bulletin are not intended to be provided as legal advice and should not be relied upon as legal advice. For further information contact the Building & Safety Standards Branch. 2

2014 British Columbia Building Code Changes A City of Kelowna interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most notable revisions and staff interpretations. This package is for information purposes only and does not constitute a formal or legal document. The actual British Columbia Building Code (BCBC) 2012 should be reviewed in its entirety for any design / construction applications. 1 Page Prepared by the Development Services Department

The following information has been obtained from the HPO Illustrated Guide, Energy Efficiency Requirements for Houses in British Columbia, BCBC 9.36 & 9.32, Building Officials Association of British Columbia and The Canadian Wood Council. 2 P age

Before December 19, 2014 The above cross section indicates the typical framing with insulation being constructed prior to December 19, 2014 where the nominal insulation thickness determined the required R-value. 3 P age

After December 19, 2014 9.36.2.4 now takes into account all of the assembly components including, cladding, sheathing framing, insulation and interior finish materials. This is known as Effective Insulation / Effective Thermal Resistance taking the whole wall assembly into consideration. 4 P age

A wall effective thermal resistance design calculator is available at http://cwc.ca/wtd, a list of assembly s and their effective insulation values is available from the Canadian Wood Council site at the address listed. Energy & Thermal Performance This wall is subject to some thermal bridging due to exposure of framing elements to outside temperature conditions. The framing factor for this wall at 16 o.c. is 23% (i.e. 23% of the wall is wood only and 77% is insulated) As an example for calculation purposes, the wall assembly above was taken from the Canadian Wood Council s Thermal Design Calculator and to meet the minimum RSI value for the wall assembly of 2.97 or R-value of 16.86 an HRV must be incorporated into this design. 5 P age

Kelowna is located in Zone 5 Prescriptive reductions for insulation values will apply for the walls, ceilings below attics and skylight shafts when an HRV is introduced into the home. 6 Page

Energy & Thermal Performance This wall is subject to some thermal bridging due to exposure of framing elements to outside temperature conditions. The framing factor for this wall at 24 o.c. is 20% (i.e. 20% of the wall is wood only and 80% is insulated) As an example for calculation purposes, the wall assembly above was taken from the Canadian Wood Council s Thermal Design Calculator and meets the minimum RSI value of 3.08 or R-value of 17.48 for a wall assembly not incorporating an HRV The RSI (R-value Systeme International) can be multiplied by 5.678 to obtain the R-Value. Kelowna is located in Zone 5, 3000 3999 Heating Degree Days, the above table indicates the required RSI values of the solid building assembly. 7 P age

Example The illustration incorporates R-40 Blown Cellulose insulation in Zone 5, with an installed HRV is compliant, without an HRV will require R-50 Conditioned Interior Space Attached garages are treated as unconditioned space, even if the garage is insulated and intended to be heated. 1) Wall between house and garage built to RSI of the above ground wall assembly Attached garages are treated as unconditioned space with no allowances for heat. The assembly (walls & ceilings) separating the garage from the conditioned space must be insulated and air tight. 8 P age

Mechanical, electrical and plumbing components placed within an exterior wall must be insulated behind to the effective thermal resistance required for the above or below grade wall assembly. Exposed foam plastics to be protected as per BCBC 9.25.2 Thermal bridging of repetitive structural members (ie; joist box ends, header spaces) must be included when calculating the thermal resistance of the exterior above grade wall assembly. 9 P age

In the attic at the perimeter wall, the insulation value must maintain a minimum RSI value as the wall assembly for a maximum of 4. ( In some designs the introduction of a high heeled truss may be warranted ) Round Styrofoam backer rod and caulking, air space without insulation meets the minimum U value of adjacent door / window The space between the framing member and window / door frame may have the same effective U-value as the adjoining window / door. 10 P age

The detailed illustration above indicates the Nominal Insulation values required in a home constructed in Zone 5 & 6 not incorporating an HRV. 11 P age

12 P age

Illustrations below indicate insulation placement for unheated and heated slabs on grade above the frost line Thermal Break 50% of the required insulation thickness Insulation placement of unheated slabs Radiant Infloor Thermal Break 50% of the required insulation thickness Insulation placement of heated slabs Insulation separated by the foundation wall at the floor slab is not required to be continuous, provided the exterior insulation extends down to the footing. 13 P age

Exposed foam plastics to be protected as per BCBC 9.25.2 When insulation is separated by the building envelope as indicated above, the interior insulation side must extend down the wall 4 times the thickness of the wall. Junctions between the floor and rim joist and rim joist to foundation must be sealed Illustrations above indicate where potential leakage conditions occur and where sealing is required between all joints and junctions between the structural components, and/or covering the structural components with an air barrier material and sealing it to the adjacent air barrier material. 14 P age

15 P age

Poly hats are required on exterior walls and ceilings for electrical boxes and pot lights and must be sealed to the air / vapor barrier The attic hatches and all electrical penetrations into the attic space along any gaps, spaces, penetrations, irregularities that could inhibit leakage must be sealed Section 9.36 of the BCBC details all areas requiring attention to air leakage, the illustrations are a few of the most common areas of concern. 16 P age

Section 9.36.2.7 of the BCBC requires garage vehicular doors to have an R Value of 6.245 or RSI 1.1 when conditioned. Example Window Label showing U-value The U-factor is a rating given to a window based on how much heat loss it allows. U-factors generally range from 0.2 (very little heat loss) to 1.2 (high heat loss). The U-factor is the inverse of the R-value of a window, which measures a window s insulating value. Thus, a high R-value is the same as a low U- factor, and means that a window does not allow much heat to escape. 17 P age

Heating Efficiencies Ducts must be insulated to the same level as required for walls if they are outside of the heated space and carrying conditioned air. Bathroom, dryer and kitchen exhaust are exempt from this requirement though are required to be directed directly outdoors, insulated to RSI 0.75 and have a vapor barrier Transverse and longitudinal joints in duct work must be sealed using an approved tape and sealant when outside the heated space. 18 P age

Heating Efficiencies Fabric tape is not approved in the BCBC for this application In general, ducts are required to be equipped with a damper. The damper may be gravity operated, motorized or spring loaded. Where motorized dampers are used, they must remain in an open position if damper operation fails, such as during power outages. 19 P age

Heating Efficiencies Exterior Roof Top Heat / Cool Unit Interior Residential Gas Furnace HVAC equipment must be located inside the heated space. Only HVAC equipment designed strictly for outdoor installation can be located outside the Heated space. Attached garages, even if heated, are considered unconditioned space. 20 P age

Heating Efficiencies Minimum Efficiency 92% Gas Fired Tankless 21 P age

Heating Efficiencies Gas Fired Boiler Minimum Efficiency 90% Air Conditioners now have a 14.5 SEER rating (Seasonal Energy Efficiency Rating) Heat Pumps now must have an 11.5 Energy Efficiency Rating The efficiency ratings for gas furnaces, boilers and hot water tanks both storage and instantaneous have been adjusted in the new requirements. Air conditioners and heat pumps also have increased efficiency ratings. 22 P age

Heating Efficiencies Gas Fired Tankless Instantaneous Gas Fired Storage HWT Electric Storage HWT The efficiency ratings for hot water tanks both storage and instantaneous have been adjusted in the new requirements. 23 P age

Service Water Heating Piping Pipe insulation is required for the first 2 m (6.5 ft) of the storage tank inlet and outlet. The insulation must be at least 12 mm (0.5 ) thick. In cases where piping is located outside the building enclosure or within unconditioned space, the insulation must be installed to a thermal resistance not less than the effective resistance requirements of the exterior above grade wall. First 2m of piping on the water storage tanks requires at least 12mm (1/2 ) of insulation. Piping located in unconditioned space must be insulated to the same value as the above grade wall. In homes with recirculating hot water systems, all piping must be insulated. Heat recovery ventilation is not a requirement of Section 9.36. Where heat recovery ventilators are used, equipment must conform to the requirements of 9.36.3.9., including having a minimum sensible heat recovery efficiency of 60%. 24 P age

9.32 Ventilation Pre December 19, 2014 the exhaust only systems were used where a fan (bathroom) was used to create a negative pressure within the space and ventilation air was achieved through air leakage from loose building construction. Post December 19, 2014 and with the introduction of a principal exhaust fan in 2006, the sizing was based on the number of bedrooms, the table above now indicates the number of bedrooms as well as floor area to determine the principal ventilation fan sizing. 25 P age

The primary ventilation system is required to run continuously, this can be achieved by the use of an HRV or a dedicated Lo-Sone fan not exceeding 1.0 sones. ( noise level ) 26 P age

With 4 options to deliver ventilation air, utilizing the forced air system interlocked to the primary ventilation fan is cost effective in a majority of applications. The fresh air piping to the forced air return duct has also been reduced in length to the furnace cabinet and must not be located upstream of a return air grill. A 2 nd option is to incorporate a passive HRV as the primary ventilation fan, the furnace blower would be required to run continuously 24/7 27 P age

The 3rd option is to incorporate an HRV as the primary ventilation system. This system is installed separately from the forced air system or as a standalone ventilation system when forced air is not being installed. The 4 th option is also installed separately from the forced air or as a system when forced air is not being installed. A primary ventilation fan is installed and interlocked with a distribution fan sized 2-3 times the primary ventilation fans capacity. The air discharge grill should be installed no closer than 2m from the floor ensuring that the cooler air is mixed with tempered air maintaining a suitable comfort level. 28 P age

Should the calculations provided on the Mechanical Ventilation Check list provided by the HVAC installer indicate the collective exhaust appliances exceed the ½ air change per hour, make up air sized accordingly to the excess exhaust must be provided to the dwelling. As Kelowna is in Radon Area 1 this clause applies. Exhaust from bath fans, primary ventilation fans and range exhaust ducts must be vented directly out doors, insulated with an RSI of 0.75 (R-4) and have a continuous vapor barrier. 29 P age

RADON CHANGES The BC Building Code does not require installation of a fan during initial construction, although designers should consider the future installation of a fan (which will require access and electrical supply) somewhere along the radon vent pipe. The BC Building Code refers to material that creates the space allowing the movement of soil gases between the air barrier system and the ground as a gas permeable layer The gas permeable layer allows for effective depressurization of that space, and functions as the drainage layer required in Article 9.16.2.1. A typical solution is to install coarse clean granular material below the floor on the ground. This allows compliance with 9.16.2.1.(1) The Radon rough in must be piped directly outdoors, an in-line fan is not required by code to complete a mitigation system. Changes have also occurred to the granular materials component and now are referred to as approved materials within the code. Alternate piping configurations may be considered by the Authority Having Jurisdiction. 30 P age