ST 19 T Aluminium Thermostatically Controlled Electric Model

Similar documents
ST 19 Aluminium Manually Controlled Electric Model

ST XX28 Stainless Steel Thermostatically Controlled Electric Model

Industrial flue gas probes. Instruction manual

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

Operating Instructions

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

Operations Manual. For Research Use Only. PH: EM: WEB:

MODELS PH PH PH

Instructions for Continued Airworthiness Talon LC Keeperless Cargo Hook Kit For the AS350 Series. System Part Number STC SR00886SE

TECHNICAL DATA SHEET DS 060

Z5033 E3 Ball joint adapter Mounting instructions

Bateau, Crucible and Timpani Vessels Installation and User Guide

MALTE Outdoor. the compact and versatile posterior-walker. Instructions for use

FILTRATION & UV SYSTEM

Protective Capony RTC-16

Instruments. multipointelite USER AND MAINTENANCE MANUAL. By MAST Group Ltd. V0.1-01/11/03

DESIGN, FABRICATION AND PERFORMANCE EVALUATION OF CONTINUOUS OPERATING AUTOCLAVE

MEDICAL TRADING knows the meaning of sterilization very well: it can be

INSTALLATION INSTRUCTION (U.S.A) FOR LUMI-O DRY NICHE INGROUND LIGHT.

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

Instruction Manual HT 24 BM-D2400 Homogenizer

INSTALLATION INSTRUCTIONS

ecosphere water purifier 3in1 USER MANUAL

TAKING YOU TO NEW HEIGHTS IN SAFETY... kwikstage

BOILER INSTALLATION INSTRUCTIONS FOR RU 1S / BRU 1 RU 2S / BRU 2 RU 3S

WE01A GMA (MIG) Plug Weld

Thank you for purchasing our product. *Please read these instructions and follow them step by step.

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

OPERATION MANUAL. Beam Clamp with Shackle

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

These instructions must be left with the user

Pressure Relief Valves. 1900/P Series. Consolidated Safety Relief Valve

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

OVERSHOT GATE TECHNICAL DATA SHEET

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

Instruction Manual HK285. Note: The Owner/Operator must read carefully and understand all the information presented here before operation.

BoSS Climalite Camera and lighting tower

Leap Walk In Enclosure

Model # 922-S4. 12/18/2013 Page 1 of 8

TA Instruments Packing the DHR Instrument

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Z5043 MAX Horizontal bracket Mounting instructions

Model BF 720 Incubators Avantgarde.Line with forced convection

1600 Currency counting machines

Operating Manual. MELAquick 12+

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model # 158-P4. 12/12/2013 Page 1 of 11

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

Modular Coldroom Installation Manual

HRO-50 Water Purifier

2 ADAPTER MOUNTING & APPLICATION

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

USER MANUAL BR LED Headlight Rev /05/2016

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. 120V Permanent Magnet Drill STARTING SERIAL NUMBER.

Adjustable Fused Power Supply

Effective Use of Autoclaves

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

RTM ACCESSORIES. MOLD SEALS ( Packing : 25LM Rolls ) Standard Dynamic Seal White. Medium Dynamic Seal Blue. Primary seal for Hollow Dynamic Seal

INTERNATIONAL STANDARD

Valance Installation. For Units with Beam Style Coils

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

ACO Building Drainage

Sby SR Instruments, Inc.

INSTRUCTION MANUAL FOR USE AND MAINTENANCE

BESTMOVE STANDING TRANSFER AID

Model # 358H-PR. 4/8/2011 Page 1 of 12

Shackles. Applications. Range. Design. CAD drawings. Finish

NAVSEA STANDARD ITEM. 2.1 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

Operator s Manual for Morse CE-Marked Hydra-Lift Drum Rollers 456-CE Series

801-MORD Mordred FIXING: Ground. ORDER No: CUSTOMER: Complied by Date AB 30/06/15 ISSUE ECN DATE SIGN /07/15 AB

ZENITH bioreactor Model BIOFERM-01-03

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

HDI 2200 Choke Position Indicator

BESTMOVE STANDING TRANSFER AID

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Conergy SolarFamulus II

BUILD A SHOWER CUBICLE

Type 56 Butterfly Valve

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

CALIBRATION TABLE OF CONTENTS. 9.1 Calibration

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 338S-OP. 9/30/2011 Page 1 of 13

WE11S GMA (MIG) Fillet Weld

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

BESTMOVE STANDING TRANSFER AID

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

Model FDL 115 Safety drying chambers for limited quantities of solvent

PRODUCTS AIR CHAMP. User Manual. Diaphragm Brake. 4", 8" and 12" Hinge Top Diaphragm Brake FORM NO. L M-0914 FORM NO.

INSTALLATION MANUAL MULTI DECK HOT MERCHANDISERS MD Versions. Solid back 3 level Pass through 3 level

Transcription:

ST 19 T Aluminium Thermostatically Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the studs before every use. DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com Warning - All external body and lid surfaces are hot during and immediately after sterilisation. Lift or move the autoclave by the top handle only.

7. Illustration A Draw-off Cock F Collared Wing Nut (2) B Aircock G Plain Wing Nut (6) C Pressure Gauge H Drop Bolt (8) D Safety Valve J Switch E Thermometer

Notes Foreword Before using this Dixons Portable Autoclave please read this booklet carefully. Please ensure that all persons likely to use this product are correctly trained in its use in accordance with these instructions. Your Dixons Portable Autoclave, operated in accordance with the manufacturers instructions, will give years of trouble free service without the need for any major servicing. Every Dixons Portable Autoclave has been manufactured to the highest quality standards by a company complying with BS EN ISO 9000 and is fully tested and ready for immediate use. Dixons Portable Autoclaves are suitable for sterilisation of: Laboratory equipment (glass and metal) Culture media Pharmaceutical preparations in sealed containers Surgical and Veterinary instruments Dressings and drapes For the sterilisation of dressings and drapes it is recommended that a Dressing Drum or Wire Mesh Basket be used. These are available as a part of the range of accessories. All Dixons Portable Autoclaves are particularly suitable for destructive sterilisation, as the operator is not restricted to a set cycle time. This can be adjusted to suit the application. This users manual consists of seven sections: 1. Installation Procedure 2. Operation 3. Sterilising Periods 4. Maintenance 5. Specification 6. Record of Inspection 7. Illustration

1. Installation Procedure 1.1 On receiving the autoclave remove all the cardboard protective covers. Unscrew the six Wing Nuts, which are holding the lid on, and remove the lid. Remove all other packaging materials from inside the autoclave. If the inspection revealed defects in the autoclave, specify below the necessary repairs or modifications which may be required: Inspection Completed Date Action Required Sign Date Sign 1.2 Ensure that the following parts are included: Autoclave body and lid complete with all fittings as per the illustration in section 7. Inner liner. Pair of liner Carrying Handles. White silicone gasket in lid. Operators manual. Test certificate. Pack of TST indicator strips. Power lead with IEC connector. 1.3 Ensure that no damage has occurred to any of the fittings paying special attention to the Pressure Gauge and Thermometer. 1.4 The autoclave is now ready for use.

6. Record Of Inspection An annual safety check will normally be sufficient unless the autoclave is in very regular use. The date of the next examination should be clearly marked on the autoclave once the examination is completed. The purpose of this form is to provide a written record of inspection. It is merely a guide as to what to look for. It does not remove the need to routinely inspect and maintain the autoclave as described in section 4. Model Type: ST 19 T Serial No: Date of Examination Is the autoclave free from all signs of physical damage and distortion? Are the internal surfaces free from major 'pitting' (up to 1.5mm is acceptable)? Is the Silicone Gasket flexible, unperished and undamaged? Is the Pressure Gauge undamaged and does it read zero at atmospheric pressure? Is the Safety Valve undamaged, free moving and in working order? Are all the Wing Nuts and Drop Bolts undamaged and in working order? Are the Aircock and Draw-off Cock undamaged and in working order? Is a written set of instructions available for reference by users of the autoclave? Inspectors Signature Insert or as applicable 2. Operation Please read these operating instructions before using the autoclave to avoid any chance of misuse. The autoclave is factory set to run at 121ºC. This is the maximum setting, which is suitable for most purposes. A lower setting can be used if required. Many materials can be autoclaved at 121ºC. These include most metals, glass, silicone rubber and many plastics. If in doubt, consult the manufacturer of the instrument or equipment concerned as the manufacturer of the autoclave does not accept liability for damage of this nature. 2.1 Remove the Inner Liner. Fill the chamber of the autoclave with water up to the height of the studs. 2.2 Articles to be sterilised should be placed into the Inner Liner, a Wire Mesh Basket or a Bottle Rack. To sterilise porous loads (i.e. dressings and drapes) it is recommended that a Dressing Drum be used. The container should not be packed tightly, especially when dressings are being sterilised. It is important that steam can circulate freely. Place the Inner Liner / Wire Mesh Basket / Bottle Rack / Dressing Drum inside the autoclave. 2.3 Locate the two Drop Bolts without Wing Nuts and move these to the upright position. Check that the Lid Gasket is correctly seated in its groove on the underside of the lid. Place the lid on the autoclave so that the 2 Collared Wing Nuts are over the upright Drop Bolts. Lightly tighten down the 2 Collared Wing Nuts as a pair - one with each hand - until the slack is taken up in them. Swing up the remaining 6 Drop Bolts into position. The remaining 6 Plain Wing Nuts should now be lightly tightened in opposite pairs. This should be done as with the Collared Wing Nuts - one in each hand - until the slack is taken up. Now tighten up all the Wing Nuts in opposite pairs - Collared Wing Nuts first. Normal finger tightness is adequate. 2.4 Close the Draw-off Cock and open the Aircock approximately 6 turns.

2.5 Plug the power lead into the autoclave. Plug the lead into the mains (the green light will show connection to the mains). Turn on the red Switch (the red light will show power on). 2.6 When the water begins to boil, steam will start to emit from the Aircock. It will splutter at first. Close the Aircock once it has stopped spluttering and a clean jet of steam is visible. It is imperative that a clean jet of steam is visible before closing the Aircock as this ensures all the air in the autoclave is expelled. Air pockets in the autoclave will cause sterilisation to be incomplete. It is advisable to use some form of sterilisation test e.g. the TST indicator strips supplied. 2.7 The temperature will now continue to rise until it reaches the preset level. 2.8 It is at this time that the sterilisation period begins. Section 3 deals with sterilisation periods. 2.9 When the sterilisation period is complete, turn off the red Switch. Depending on the materials being sterilised, see section 2.10 or 2.11. 2.10 Bottles or other sealed vessels containing liquid - do not, under any circumstances, open the Draw-off Cock or the Aircock or release pressure from the autoclave in any manner. To release pressure from the autoclave at this point could cause the containers to explode. Allow the autoclave to cool until the Thermometer shows 80ºC or less. 5. Specifications Model Type: Capacity: Internal Diameter: Internal Height: Overall Width: Overall Depth: Overall Height: Net Weight: Chamber Material: Heat Source: Design Pressure: H T Pressure: S W Pressure: Complies With: ST 19 T 14 litres 280mm 230mm 420mm 400mm 410mm 15.0Kg Die Cast Aluminium LM25 Internal Electric Element 230V - AC 50Hz - 2.0kW Electronic Thermostatic Control 1.3 bar (18 psi) 2.0 bar (30 psi) 1.3 bar (18 psi) H&SE PM73 (Lid Locking) BS3456 : Part 101 : 1987 (Electrical Safety) PED - 97/23/EC EMC - 89/336/EEC

Slotted Adjuster and the top of the Safety Valve body. Set the Safety Valve to the desired setting using a test rig. 4.6 Electrical Maintenance (by a qualified Electrician only) - One element is internally fitted - 2.0kW - requiring a minimum 10A fuse. Check that the terminals on the elements are tight and that the elements are securely mounted in the base. Check the Switch and light for damage. Replace if necessary. See that the IEC connector fits firmly in the socket. 4.7 Overheat Cutout - To avoid damage to the element, should the autoclave boil dry, it is fitted with an automatic overheat cutout. This is clamped to the base of the chamber. If the device should cutout it must be manually reset. Before doing this switch off the mains to the autoclave and remove the plug. Allow the autoclave to cool down. To reset the cutout turn the autoclave upside down and remove the perforated protection plate from the bottom. The cutout will now be visible. It is a round black unit approximately 15mm in diameter with a red button protruding from the middle. To reset the cutout press this red button. You should hear an audible 'click' as the cutout is reset. Refit the protection plate and turn the autoclave the right way up. The autoclave will now work as before. 4.8 Thermostat Adjustment - The autoclave is controlled by an electronic thermostat mounted in the base. The working temperature is adjusted using a potentiometer mounted on the skirting band. Remove the protective cap to the left of the rating plate to access the potentiometer adjuster. The adjuster is a blue fluted shaft. Bring the autoclave up to working temperature. To increase the working temperature turn the adjuster clockwise and to the decrease the set temperature turn the adjuster anti-clockwise. A turn of 30º equates to approximately 5ºC. The autoclave should be left to settle for about 2 minutes after each adjustment. When the desired setting is reached replace the protective cap. The maximum setting allowed is 121ºC. 2.11 Dressings, instruments and apparatus - (providing the apparatus does not have sealed glass containers holding liquid). Warning - The water and steam that is released from the autoclave at this stage is extremely hot. Wear suitable protective equipment at this stage. Place a suitable receptacle beneath the Draw-off Cock and open the Draw-off Cock to release water and steam under pressure from the autoclave. When steam ceases to emit, close the Draw-off Cock and allow the autoclave to cool until the Thermometer shows 80ºC or less. During the cooling period a partial vacuum will form inside the autoclave. This will help in drying the contents. 2.12 When the autoclave is cooled, the Aircock should be opened approximately 6 turns. Check that the Pressure Gauge is reading zero. Unscrew the 6 Plain Wing Nuts in opposite pairs - one in each hand - 2 full turns. Now unscrew the 2 Collared Wing Nuts as a pair - one in each hand - 2 full turns. This will allow the lid to rise to a safe position, where it is still held captive, but has enough clearance to release any residual pressure still in the autoclave. Unscrew the 6 Plain Wing Nuts fully in opposite pairs - one in each hand - and swing down the Drop Bolts. Unscrew the 2 Collared Wing Nuts completely as a pair - one in each hand - and remove the lid. Do not attempt to remove the lid until all the Wing Nuts are released. 2.13 Remove the sterilised contents.

3. Sterilising Periods The following times apply to a loosely packed load. Dressings in particular should not be packed tightly as steam will not penetrate. Wire Mesh Baskets or Dressing Drums are recommended for this application. When large packs of dressings or large volumes of liquid are being sterilised, it is advisable to allow a further 10 minutes sterilisation time. This ensures adequate penetration of the materials by steam and heat. Use these times as a general guide only - always use a sterilisation test e.g. the TST indicator strips supplied. Instruments and Equipment Dressings and Drapes Liquid in Sealed Containers (0ml - 50ml) Liquid in Sealed Containers (50ml - 100ml) Liquid in Sealed Containers (100ml - 200ml) Culture Media (up to 1 litre) Notes on sterilisation of Culture Media: 1. Always follow the manufacturer's instructions. 2. Use volumes up to 1 litre. 3. Use similar volumes in the same load. 4. After cycle test for sterility. 5. Check microbiological performance before use. 121ºC 15 minutes 121ºC 30 minutes 121ºC 20 minutes 121ºC 20 minutes 121ºC 20 minutes 121ºC 15 minutes 4. Maintenance UK users - this autoclave comes within the scope of 'The Pressure Systems and Transportable Gas Containers Regulations 1989' and should be inspected and maintained accordingly. General maintenance should be carried out by a competent person only, as and when deemed necessary. 4.1 Lid Gasket - Check the white silicone Lid Gasket for distortion or wear and tear. The Lid Gasket is located in the groove on the underside of the lid. Check that it has not become brittle. Replace the Lid Gasket with a new one if necessary. 4.2 Body Rim - Check the rim of the body where the Lid Gasket seats for damage to the metal casting which would cause the lid seal to leak. If the damage is only minor, then the rim can be repaired by filing and smoothing with emery cloth. Major damage should be referred to the manufacturer or a qualified service engineer. 4.3 Draw-off Cock - Check the Draw-off Cock for signs of leaking around the seals and from the valve. Replace the seals or complete Draw-off Cock with a new one if necessary. 4.4 Cleaning - The use of alkalis (e.g. sodium bicarbonate) may cause corrosion of the pot and lid and should therefore be avoided. Use normal household detergent to clean the interior of the autoclave. 4.5 Safety Valve Adjustment and Maintenance - The Safety Valve is factory set using a test rig to release pressure at 1.3 bar (18 psi). Adjustment - The safety valve should be adjusted using a test rig. The maximum working pressure is 1.3 bar (18 psi). Maintenance - Remove the top cap, undo the locking grub screw and unscrew the Slotted Adjuster. Remove the spring and spindle to expose the Silicone Seal. Clean all parts and check the Silicone Seal for wear. Replace if necessary. Reassemble using a small smear of Autoclave Grease on the spindle and threads. Set a gap of about 4mm between the