Corrosion in biomass-fired installations

Similar documents
1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

GCE Environmental Technology. Energy from Biomass. For first teaching from September 2013 For first award in Summer 2014

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER

Recovery Boiler Corrosion Chemistry

Finding the Root Cause is Critical

Iron filings (Fe) 56g IRON + SULPHUR IRON SULPHIDE

Electricity and Chemistry

Combinations of alloys and environments subject to dealloying and elements preferentially removed

Suggest one reason why spoons are electroplated. ... Why is hydrogen produced at the negative electrode and not sodium?

Design and Operation of Biomass Circulating Fluidized Bed Boiler with High Steam Parameter

Manufacturing of Fe-Cr-Al weld overlay coatings for high temperature applications

High Temperature Corrosion Behavior of DS GTD-111 in Oxidizing and Sulfidizing Environments

Intergranular Corrosion (IGC)

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

When temperature is small, about 500oC or 930oF, nitrogen diffusion is nominal.

Introduction: Thermal treatment

Cladding Solutions for the Waste to Energy Industry

Emissions from wood-fuelled equipment. Senior research scientist Heikki Oravainen Technical Research Centre of Finland

Biomass co-firing. Technology, barriers and experiences in EU. Prof.dr.ir. Gerrit Brem. TNO Science and Industry

Could biomass boilers be operated at higher steam efficiencies (higher temps.)?

Draw a ring around the correct word in the box to complete the sentence.

High Temperature Oxidation Behaviour of Low Carbon Steel and Austenitic Stainless Steel

Condensate System Troubleshooting andoptimization

PPS Outshines Stainless Steel in Chemically-Hostile Valve Applications

Heat Treatment of Tubes for Condenser, Feedwater Heater, and Shell & Tube Heat Exchangers

Properties A Metal B Non- metal Electronic configuration?? Nature of oxides?? Oxidizing or reducing action?? Conduction of heat and electricity??

Gasification of Biomass and SulfurContaining Carbonaceous Fuels. Majid Charmchi

High Temperature Corrosion in Gasifiers

Science Class 8 Topic: Elements And Compounds Reinforcement Worksheet

REACHED DEVELOPMENTS OF BIOMASS COMBUSTION TECHNOLOGIES AND FUTURE OUTLOOK

Solutions. for Severe Corrosion

Influence of hydrogen in weld joints

Table of Contents. Preface...

Steam Cycle Chemistry in Air-Cooled Condensers. NV Energy ACC User s Group * November 12-13, 2009 Andrew Howell * Xcel Energy

Prevention Strategies Design and Coatings

Laser measurement of KCl vapor in 4 MW CFB boiler during straw combustion and ferric sulfate injection

Alkali and zinc chlorides in waterwall tube corrosion:

SAMPLE PAGES PAGES. Extraction of metals from metal oxides. mixture of iron sand and coal are heated as they move down kiln, by force of gravity

CRHS Academic Chemistry Unit 1 Matter and Change HOMEWORK. Due Date Assignment On-Time (100) Late (70)

Heat Treating Basics-Steels

Fireside Corrosion in Oxy Fuel Combustion of Coal/Biomass

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Molten Carbonate Fuel Cells - Kouichi Takizawa

CHAPTER 9. The Uses of Sulphuric Acid

Smart CHP from Biomass and Waste

Two-stage Gasification of Untreated and Torrefied Wood

ICSE-Science 2 (Chemistry) 2004

2.3 Chemical Changes corrosion Kinds of Corrosion

Q1. The data in the table below show the melting points of oxides of some Period 3 elements. O 10 O P (Extra space) (2)......

High Power Generation from Recovery Boilers - What Are the Limits?

RECOVERY BOILER SUPERHEATER CORROSION SOLUBILITY OF METAL OXIDES IN MOLTEN SALT

The Biomass Option. Types of Biomass. Pellets market and products. Summary and Conclusions

Clean energy, natural solutions. Understanding rice husk as a biomass fuel

SUPERCRITICAL COAL FIRED POWER PLANT

Efficiency Improvement and Biomass. Robin Irons

Extracting and using metals. ores. native. Only the most unreactive metals such as gold and platinum are found as native metals.

Year 7 Chemistry HW Questions

INTRODUCTION. Think HSS

Plant construction and waste heat systems for the chemical industry

A STUDY OF CASTING CHARACTERISTICS FOR DIE-CAST ALUMINUM ALLOY

Development and optimization of a two-stage gasifier for heat and power production

Methods of Corrosion Control. Corrosion Control or Corrosion Management?

Investigators: R. E. Mitchell, Associate Professor, Mechanical Engineering Department; P. A. Campbell and L. Ma, Graduate Researchers

Iron oxide and cobalt oxide have been added to the glazes on pottery for hundreds of years.

AMETAL AMETAL AMETAL APPLICATIONS GENERAL

WeldingAL-6XN. General Welding Recommendations

The Need For Protecting The Weld And Rationale

GENARAL INTRODUCTION TO METALLURGY :Std: XI-CHEMISTRY

Materials technology for thermal energy processes

Gasification of Municipal Solid Waste

Boiler Tube Deposition - Full scale performance trials have shown that the high

Passivity Definitions and Influencing Parameters

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

Adhesion Strength of Biomass Ash Deposits

INTRODUCTION TO THE HIGH-TEMPERATURE OXIDATION OF METALS

About Praxair. Air Separation. Applications. our purpose. 1 Where your talent makes an impact


CO forms CO 2. forms. (a) The coke reacts with the oxygen in the air to form carbon dioxide. C + O 2

Corrosion and Corrosion Protection

Microstructure and Strength Properties of Austenitic and Ferritic Stainless Steels When Brazed with Ni-Cr-P Amorphous Brazing Foils

View from the Penthouse

MINISTRY OF EDUCATION AND HUMAN RESOURCES, TERTIARY EDUCATION AND SCIENTIFIC RESEARCH MAURITIUS EXAMINATIONS SYNDICATE. CHEMISTRY OCTOBER hour

STRESS CORROSION CRACKING OF STAINLESS STEELS IN HIGH PRESSURE ALKALINE ELECTROLYSERS

Solidification and Crystallisation 5. Formation of and control of granular structure

Mikko Hupa Åbo Akademi Turku, Finland

Metals I. Anne Mertens

MR. D HR UV AS HE R I.C.S.E. BOA RD PAP ER ICSE

APPLICATIONS OF Fe-C PHASE DIAGRAM

Boiler panel protection technology. The best solutions and service with WA Integra

Analysis of Tube Failure in Water Tube boiler

Failure Analysis of Coating Adhesion: Peeling of Internal Oxidation Layer over Electrical Steel after Stress Relief Annealing

Pyrolysis and Gasification

Co-combustion in fluidised bed influence of K, Cl and S

calcium oxide removes acidic oxides basic oxides acidic oxides basic oxides Iron obtained from the blast furnace is contaminated with

Packed Bed Combustion: An Overview. William Hallett Dept. of Mechanical Engineering Université d Ottawa - University of Ottawa

Corrosion Control and Cathodic Protection Data Sheet

Advanced Analytical Chemistry Lecture 10. Chem 4631

Coal Quality & Boiler Efficiency

Poultry Litter as a Renewable Resource. Fibrominn Biomass Power Plant

Flexible Water Hose Failures: A Case Study and General Design Considerations

The ANDRITZ GROUP Overview

Transcription:

Corrosion in biomass-fired installations By Trine Nybo Lomholt, specialist & Søren Klinggaard, project manager Straw and wood chips are attractive fuels, but firing with biomass rather than fossil fuels presents greater challenges in terms of corrosion. Firing with biomass presents considerably greater corrosion-related challenges than firing with fossil fuels. This is due in part to the different chemical composition of biomass, especially its higher content of potassium and chlorine. The following is an introduction to the most common corrosion mechanisms. Corrosion zones in biomass- and waste-fired boilers Purely in terms of corrosion, biomass- and waste-fired boilers can be divided up into three zones: The fuel feed zone (funnels etc.) The high-temperature zone (combustion chamber, superheater etc.) The low-temperature zone (convection and economiser section etc.) Figure 1: Corrosion zones in biomass-fired boilers

The fuel feed zone In the fuel feed zone, partial gasification of the fuel can potentially result in the release of volatile hydrocarbon compounds and organic acids. These may be carried into the actual combustion zone, where they can reevaporate, thus avoiding any increased corrosion risk. If, however, the gasified components diffuse back into the system and then come into contact with materials at low temperature, such as water-cooled walls, the situation is more critical. In this case, the organic acids will condense out, giving rise to gradual corrosive attack, which ultimately could cause the boiler to leak. For instance, acetic acid and formic acid can begin to condense out at temperatures of just 110 C. Corrosion damage caused by aggressive components condensing out of the combustion air can be mitigated/eliminated by cladding highly critical elements. This raises the surface temperature of these elements, preventing condensing out. Grate corrosion Corrosion is generally not observed in the area around the grate as often as in the hotter parts of the installation. However, there are two issues that can cause grate corrosion. The first is abrasion from biomass containing sand and soil. The second is uneven oxygen distribution across the grate, especially along the sides, where it can be difficult to maintain an oxygen surplus, rendering the atmosphere reductive. As a result, the metal surface cannot form a protective oxide layer. An oxygen deficit will also mean a greater proportion of uncombusted particles and deposits in the flue gas, which will burn out on the metal surfaces and react with them. This can result in the oxide layer being partially dissolved and becoming porous, thus making it easier for aggressive substances to access the metal surface, potentially inducing increased corrosion. Corrosion in the high-temperature zone Most corrosion occurs in the high-temperature zone of the installation, including the superheaters. Superheaters are often made of alloy steel containing chromium, which forms a protective chromium oxide layer on the surface. If chlorine and potassium are present in the flue gas, reactions can occur between the flue gas and the metal surfaces, as a result of which the protective oxide layer is broken down and the surface protection is lost. Three main corrosion mechanisms are common in the high-temperature zone: Chlorine corrosion Alkali corrosion Molten salt corrosion.

Chlorine corrosion The mechanism behind chlorine corrosion is described in detail in the literature, so here a summary will suffice. Chlorine in the flue gas is able to pass through small cracks and defects in the protective chromium oxide layer of the steel surface. The chlorine gas then comes into contact with the underlying metal surface and the subsequent reaction produces metal chlorides. At the high prevailing temperatures, the metal chlorides evaporate and pass back out through the oxide layer. When the metal chlorides come into contact with the oxygen on the surface, they are converted into oxides, releasing more chlorine gas. This chlorine gas is free to penetrate the oxide layer, and the cycle begins again. This mechanism is illustrated in Figure 2, where iron (Fe) is used as an example. Figure 2: Illustration of chlorine corrosion, based on Asteman [1]. This type of corrosion effectively dissolves the metal beneath the oxide layer, inhibiting the growth of the protective chromium oxide layer. As a result of the chlorine corrosion, the oxide layer also becomes porous and peels off. Alkali corrosion In the past, chlorine was regarded as the biggest cause of corrosion in biomass-fired power stations. In recent years, however, there has been greater focus on the fact that alkali metals, chiefly potassium, also play a crucial role in the breakdown mechanism. When potassium is present in the flue gas, it will react with chromium oxide, forming potassium chromate. This means that chromium in the oxide layer is consumed, leaving behind an iron-rich oxide layer. Iron oxide is not as protective as chromium oxide in the atmosphere in question, which means the rate of corrosion is increased. This also leads to accelerated chlorine corrosion. In some cases, sulphur can reduce alkali corrosion through the formation of potassium sulphate rather than potassium chromate with potassium sulphate having a less corrosive effect on chromium oxide. It depends, however, on the specifics of the reaction, as it triggers the formation of chlorine gas. If potassium chloride is

converted to potassium sulphate in the flue gas, the chlorine gas will probably escape with the flue gas and not present any real risk. But if chlorine gas is formed beneath the coatings, it will cause chlorine corrosion. Molten salt corrosion In the case of chlorine corrosion, metal chlorides are formed, as described above. Many metal chlorides melt at the temperatures prevailing in the combustion chamber. Furthermore, many of the salts contained in the deposits from the fuel also melt at those temperatures. The metal chlorides and salts can also react and form so-called eutectic compounds, which melt at even lower temperatures. Molten chlorides, salts and eutectic compounds are extremely corrosive, dissolving the protective oxide layer of the metal surface. This mechanism is called molten salt corrosion. Experiences from installations The following general experiences have been acquired in the course of FORCE Technology s work as a consultant and through studies of damage observed in biomass-fired installations. Temperature and flue gas flow The steam temperature is not the only factor influencing corrosion in biomass-fired installations; the metal temperature, flue gas flow and heat flux also need to be taken into consideration. The metal temperature is dependent on the steam temperature, flue gas flow and heat flux. It is important to optimise the interaction of these factors in order to reduce the rate of corrosion. Likewise, it is essential to avoid reductive gases in the installation, which can be done by ensuring that particles are burnt out before they come into contact with the metals. Fuel type Firing with straw causes the highest corrosion rates within biomass, primarily due to the relatively high contents of potassium and chlorine. However, although wood pellets and wood chips have a considerably lower content of these elements, they can still induce corrosion rates equivalent to those seen in straw-fired boilers, due to the lower content of other elements (aluminium, silicon, sulphur) with which the alkali metals normally react. Consequently, potassium chloride can be found in the gas phase after combustion, and this will condense on the surfaces and lead to the same type (and rate) of corrosion as with straw firing. It should also be mentioned that it is essential to be extremely watchful with waste wood, as its chemical composition is different to that of untreated wood, and this has a major impact on corrosion. Waste wood may contain lead or similar chemical compounds, inducing the corrosion mechanisms evident in waste combustion.

Alloy type and chromium content In coal-fired power stations, it is well known that a high content of chromium in the alloys gives low corrosion rates. But this is not necessarily the case in biomass-fired power stations, where the effect of the chromium content on the corrosion rate also depends on the type of alloy and the temperature. The typical alloys used in superheaters can be divided into three categories: Ferritic/martensitic steel (Cr <12 wt%) Austenitic steel (Cr 15-18 wt%) High-alloy austenitic steel and nickel-based alloys (Cr 20-30 wt%). Ferritic/martensitic steel alloys generally have an even outer-corrosion layer with no considerable grain boundary attack. Material loss is caused by peeling of the outer-corrosion layer. The corrosion rate decreases with an increase in chromium content. In austenitic steel, the corrosion layer is typically divided into a thin outer oxide layer and an underlying zone with grain boundary corrosion, which indicates the effect of chlorine. Austenitic steels can tolerate higher temperatures than ferritic/martensitic steels, so this modified appearance occurs mainly at higher temperatures. The corrosion is exacerbated by higher temperatures and a higher chromium content in the steel. In high-alloy austenitic steels and nickel-based alloys, a similar two-part corrosion layer is seen, but the internal zone suffers attacks inside the grains as well as at the boundaries. The depth of the internal corrosion zone increases with increased chromium content as an effect of chlorine corrosion. Monitoring of corrosion conditions in biowaste-fired installations As is evident from the above, there are many factors influencing corrosion conditions in the burning of biofuel. Some of these conditions make it difficult to predict the extent of corrosion in the boiler. FORCE Technology is making a targeted effort to build up expertise in improving the predictability of corrosion conditions, and an important tool to this end is corrosion measuring performed with a newly developed corrosion probe. This probe is shown in Figure 3. It is air-cooled and designed so that the surface temperature can be precisely regulated, making it possible to test the effect of the flue gas at various temperatures. The corrosion probe has been used at the Danish Test Centre for Bioenergy to measure corrosion conditions in the burning of wood pellets. A number of other tests are being developed, which we hope to be able to present here at a later date.

Figure 3: Corrosion probe Figure 4: Close-up of the corrosion probe after approx. 1 month s exposure in a biomass-fired installation References [1] H. Asteman and M. Spiegel, Corrosion Science, 49 (2007) 3626 3637