City of High Point Airport Overlay District Noise Level Reduction Design Standards

Similar documents
3.1 Noise Overlay District

Boulder City NV Prepared by (Print Name) Signature Date

2010 National Building Code Adoption and Associated Process Changes

Feature Zone IECC 2009 IECC

Administrative Changes

Plan Check & Field Inspection Guide

2003 International Residential Building Code

2006 INTERNATIONAL ENERGY CONSERVATION CODE

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

One and Two Family Additions

Advanced Ventilation for Residential applications FBC Res 2010.

Inspection of New One- and Two- Family Dwellings

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Sound Insulation and Thermal Performance Modifications: Case Study for Three Dwellings Near BWI Airport

Hardin County Planning and Development Commission

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

INTERIOR ENVIRONMENT

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

INTERIOR ENVIRONMENT

RESIDENTIAL BUILDING REQUIREMENTS

Building Guide. Colorado Chapter of the International Code Council

Michigan Energy Code Training and Implementation Program

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

General Residential Code Requirements

IRC 2012 Key Changes

Typical Finished Basement Details

Acoustic Design Criteria

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

2018 WEATHERIZATION SPECIFICATIONS MANUAL

2012 IECC Residential with State Adopted Changes

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Residential Building Inspections

New Hampshire Residential Energy Code

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

Chapter 1: Compliance

Basement Renovation Guide For Residential Dwellings

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Each proposed project will be reviewed for compliance with the following codes as applicable.

RESIDENTIAL ENERGY EFFICIENCY

Fairfax County, Virginia

Questar ThermWise Duct Technical Specifications

Residential Accessory Structures & Room Additions

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Single Family Residence Building Permits

Knauf Makes It Easy to Insulate

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

TYPICAL BEARING WALL FRAMING

Installation Instructions

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

SECTION NON-STRUCTURAL METAL FRAMING

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

fort collins building & zoning

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

CONSTRUCTION CODE PERMIT INFORMATION

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Construction Report NYSERDA Residential Performance Challenge

R Code and Commentary for 2012 NC Residential Code final 03/06/13

1) For the purpose of this Section, the term common space shall mean all spaces required to

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

R vertical and horizontal.

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

ALASKA ENERGY BUILDING STANDARD EFFICIENCY

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Vermont Residential Building Energy Code. Handbook. A Guide to Complying with Vermont s Residential Building Energy Standards (30 V.S.A.

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

BC BUILDING CODE ERRATA

Formulating a Korea Industrial Standard for light-frame wood construction

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

The ATP that follows is recommended to be used for all phases of the FLL RSIP beginning June 1, The ATP describes the following:

Vermont Residential Building Energy Code. Handbook

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

The Inspection Process. Waxhaw N.C.

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

This page was. intentionally. left blank

CHECKLIST Inspecting a Garage

Transcription:

City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High Point s Airport Overlay District, contained within the city s Development Ordinance, requires that all new residential uses developed within Zone 3 of the district be designed to achieve an outside to inside noise reduction level of at least 30 decibels (db). This noise reduction requirement may be achieved by any suitable combination of building design, building materials and construction standards so as to reduce the interior noise levels from overhead aircraft flights. The Zone 3 NLR requirement applies only to new residential construction and not to the expansion of existing residential uses or to structure additions. II. NLR COMPLIANCE. The following noise level reduction design standards are taken from the Wyle Laboratories Report: New Construction Acoustical Design Guide (WR 03-10) prepared for the City of High Point and dated April 2003. These design standards are applicable to plans and specifications for any proposed residential use and building constructed to comply with the Airport Overlay District s minimum 30 db NLR requirement for Zone 3. The Airport Overlay District requires that prior to the issuance of a building permit for a residential use in Zone 3, a qualified acoustical professional must certify that the design standards, construction methods and materials used to construct the residential use will achieve at least a 30 db noise level reduction. The plans and specifications for a building permit may either (1) indicate compliance with these NLR design standards herein or (2) provide written certification from a qualified acoustical consultant confirming that the construction of the building as indicated in the plans and specifications will result in a minimum 30 db NLR. When using these NLR design standards, please refer to the Wyle Laboratories Report: New Construction Acoustical Design Guide (WR 03-10) for details and reference information. III. GENERAL NLR DESIGN STANDARDS. A. The NLR standards should be applied to all occupied rooms having one or more exterior walls or ceiling. The Sound Transmission Class (STC) ratings required for exterior walls, windows, doors, and ceilings are presented in Table 4-1 of the New Construction Acoustical Design Guide. B. Sound Transmission Class (STC) ratings for windows and doors are valid only if they are determined by laboratory tests performed by an independent laboratory for the product manufacturer. A rating estimated for glass alone is not an acceptable substitute for STC tests of windows. Likewise, ratings estimated for door leafs alone are not an acceptable substitute for STC ratings of doors. The installed products must have the same accessories such as storm panels, glazing thickness, glazing size, gaskets, bottom door seals, thresholds, etc., as the tested assembly. 1

C. In order to achieve the STC ratings specified below, special measures are necessary to install doors and windows. These include the use of non-hardening (acoustical) caulk at all hidden surfaces, flexible caulk at all exposed surfaces, and solid continuous blocking to fill all voids over 1/4 around windows and doors. IV. MINIMUM 30 db NLR BUILDING STANDARDS. A. Exterior walls 1. Exterior walls, other than as described below, shall have a laboratory sound transmission class rating of at least STC-43. This rating can be achieved as follows. The gypsum board or plaster shall be fastened rigidly to the studs if the exterior is brick veneer. If the exterior is siding, then the interior gypsum board or plaster must be fastened to the studs using resilient channels. Resilient channels must be installed horizontally along the studs, and screws connecting the gypsum board or plaster to the channels must not contact the studs. Oriented Strand Board (OSB) at least 7/16 inches thick shall cover the exterior side of the wall studs. 2. Rooms that have one exterior wall and a total exterior wall area below 170 square feet need not meet the requirements of the paragraph above. 3. The interior surface of the exterior walls shall be of gypsum board or plaster at least 1/2 inch thick. 4. Fiberglass batt or blanket insulation shall be installed continuously and completely throughout the stud cavity. Batts or blankets should be held firmly in place between studs, with fasteners if necessary, to prevent sagging; however, packing the insulation such that it is compressed may slightly reduce its acoustical (and thermal) performance. B. Windows 1. Windows, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-33. 2. Windows in rooms with 2 exterior walls and a total exterior wall area greater than 300 square feet must have a laboratory sound transmission class rating of at least STC-40. C. Doors 1. Exterior doors, or door/storm composite assemblies, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-26. A typical door in combination with a typical storm door will achieve a rating of at least STC 26. Therefore, either a door tested to achieve an STC 26 rating may be used, or else a storm door can be added to an untested door. If a storm door is not used, then all glass in the door shall be at least 3/16 thick. 2. Doors in rooms with 2 exterior walls and a total exterior wall area greater than 300 square feet must have a laboratory sound transmission class rating of at least STC-33. This rating may be achieved either by using a door tested to achieve an STC 33 rating, or a typical door in combination with a secondary/storm door tested to achieve an STC 29 rating, or a typical door in combination with a full-view 2

secondary/storm door utilizing 1/4 thick laminated glass. If a storm door is not used, then all glass in the door shall be at least 1/4 thick laminated glass. 3. Interior doors between occupied spaces and attached garages or unfinished attic spaces shall be solid-core wood or 20-gauge insulated metal at least 1-3/4 inches thick and shall be fully weather-stripped. 4. If a storm/secondary door is used, then the airspace between the surfaces of the two doors shall be maximized. D. Roof-Ceiling Assemblies 1. The standard roof construction is assumed to be shingles, 7/16" minimum OSB deck, and wood trusses or rafters spaced 16" or more O.C. forming an attic space over occupied rooms. 2. Roof-ceiling assemblies in top-floor rooms with 2 exterior walls and a total exterior wall area greater than 300 square feet must have a laboratory sound transmission class rating of at least STC-56. The required construction consists of resilient channels mounted perpendicular to the ceiling joists, on the bottom of the joists, with one layer of ½ gypsum-board attached to the channels. Resilient channels must be installed horizontally along the studs, and screws connecting the gypsum board or plaster to the channels must not contact the studs. 3. The use of cathedral ceilings is not allowed. A mock-cathedral ceiling with a small attic space above is acceptable. 4. Skylights can be used if a secondary panel of 1/4-inch-thick safety glass or insulated thermopane glass is used at the bottom of the skylight well. Alternatively, skylights with an STC 38 rating can be used. 5. Gypsum board or plaster ceilings at least 1/2 inch thick shall be provided. Ceilings shall be substantially airtight with a minimum number of penetrations. E. Floors, Foundations and Basements 1. The floor of the lowest occupied rooms shall be slab on fill, below grade, or over a fully enclosed basement or crawlspace. If the basement is used as a habitable living area (as a recreation area, study, or additional sleeping area, for example), then the doors and windows shall conform to the requirements stated in herein. 2. Concrete slabs require no treatment. 3. Crawl spaces with masonry walls must have noise control louvers at the under-floor vents (see Appendix B). If crawl spaces do not have masonry walls, then a massive barrier panel must be used as a skirt connecting the bottom of the walls to the ground (see Section 3.7). 4. Dryer vents and other basement vents should be constructed of sheet metal to limit the amount of noise that will enter through them and then pass through the duct wall to the surrounding room. 3

F. Ventilation and Wall Penetrations 1. In-window, through-wall, or through-floor air-conditioning, ventilating, or heating units shall not be used. 2. Through-the-wall/door mailboxes or mail slots shall not be used. 3. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms, as specified in the North Carolina State Building Code, without the need to open any windows, doors, or other openings to the exterior. 4. Gravity vent openings in attics shall not exceed the building code minimum in number and size. 5. If an attic fan is used for forced ventilation, then the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20 gauge steel at least 5 feet long with at least one 90 bend. 6. All vent ducts connecting the interior space to the outdoors, excepting domestic range exhaust and bathroom exhaust ducts, shall be at least 10 feet long and shall contain at least two 90 bends. It is recommended that in-line sound attenuators (silencers) be installed in fresh-air intake ducts larger than 3 in diameter. 7. Unvented range exhaust fans should be used, if allowed by the building code. If unvented range exhaust fans are not used, then the range exhaust ducts connecting the interior space to the outdoors shall be at least 20 gauge steel and shall contain at least two 90 bends. 8. Fireplaces shall be provided with glass doors and well-fitted dampers. Wood stoves shall not be used. Fireplaces in bedrooms are not allowed. 4

Part B. Residential Design Standards for Zone 4 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 4. The City of High Point s Airport Overlay District, contained within the city s Development Ordinance, requires that all new residential uses developed within Zone 4 of the district be designed with a central heating and air conditioning system to enable the closure of windows within the structure during all climate conditions. The Zone 4 NLR requirement applies only to new residential construction and not to the expansion of existing residential uses or to structure additions. II. NLR COMPLIANCE. The Airport Overlay District requires that prior to the issuance of a building permit for a residential use in Zone 4, the permit applicant must certify that the residential use will be constructed in accordance with approved construction plans that meet this NLR requirement. A central air conditioning and heating system that is installed to cool and heat all occupied parts of the structure will meet this NLR requirement. The air conditioning and heating system installed must meet all requirements of the N.C. Mechanical Code. 5