Life-Cycle Assessment of LEED vs. Conventionally Constructed Residential Units

Similar documents
AIR FORCE INSTITUTE OF TECHNOLOGY

Energy Analysis and Savings Opportunities For Habitat for Humanity 3 Bedroom Ranch House

A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION

Least Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates)

Energy Analysis of a Straw Bale House

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

This page has been left blank intentionally.

IV. Energy Use Strategies

Making Super-Efficiency Affordable: A Story of a Near-Zero Net Energy Multifamily Development

Energy Savers: Air-Source Heat Pumps

LIFE-CYCLE ASSESSMENT (LCA) FOR SPRAY POLYURETHANE FOAMS

Convective Loss in Loose-Fill Attic Insulation

Methods, Impacts, and Opportunities in the Concrete Building Life Cycle

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Green Building Consulting and Verification. Energy Efficiency Optimization For LEED, Savings by Design, GreenPoint Rating, New Solar Homes Partnership

Uncertainty in LCA from Economic Input Output Models. Chris Hendrickson Francis McMichael Carnegie Mellon

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Heat Pumps (Air Source, Split System)

Bullitt Center s Energy Performance

A Building LCA Case Study Using Autodesk Ecotect and BIM Model

ASHRAE 90.1, Energy Analyses and Construction Drawings: A Brief Insight Into Energy Challenges

Life cycle assessment tool for building assemblies

Assessment of embodied energy analysis methods for the Australian construction industry

One That is Already Built.

LEED V4 FACT SHEET FOR STEEL PRODUCTS USED IN CONSTRUCTION APPLICATIONS

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

LEED with COLD FORMED STEEL

Sample Energy Benchmarking Report

Green Star Design & As Built v1.2. Minor wording corrections have been implemented throughout the Submission Guidelines to improve clarity.

Water System Sustainability Symposium

Technical Brief. Precast wall systems and the evolution of sustainability. altusgroup

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Life Cycle Building Energy:

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Residential Cool Roof/ Roof Insulation Measures Stakeholder Meeting #2

LEED Analysis of the Knight Management Center. Energy & Atmosphere. Materials & Resources

Penn State AE Senior Thesis 2009

Energy and Climate. Energy and Climate. Summary of Activities and Performance

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Comparison of Cradle-to-Grave GHG Emissions among Spray Foam Expansion Agents

affects the credibility of the analysis results. Construction site data is mainly collected from the records of specific case and directly influenced

ENVIRONMENTAL FOOTPRINT 2O16

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

A Case Study in Energy Modeling of an Energy Efficient Building with Gas Driven Absorption Heat Pump System in equest

DPR Phoenix Regional Office Net Zero Certification

The Centre for Interactive Research on Sustainability, UBC: Creating Net Positive Benefits at Multiple Scales

PAVEMENT PRESERVATION A SOLUTION FOR SUSTAINABILITY

ENERGY STAR Multifamily High-Rise (MFHR)

Conservation & Demand Management Plan

Performance of Energy Management Systems

Environmental sustainability assessment methodologies for steel and timber structures

Reducing Costs with Energy Efficiency

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition

EER & SEER AS PREDICTORS OF SEASONAL COOLING PERFORMANCE

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

Guide Specification for Concrete for LEED v4 Projects

Homes. Plan Review Input Form. Office Use: P l an Rev iew Contro l Nu mb er

2012 CLEAResult All rights reserved. Residential Energy Efficiency

Instant discount of 33% off improvement cost, up to $1,250 Plus, potential savings bonus of up to $250 (**)

DoD Sustainability Strategy The Latest. Mr. Dave Asiello DUSD(I&E)/CMRM

ROCKWOOL Blanket (and Batt) Insulation Section Master Guide Specification Page 1 Jan 2017

PRODUCT DISCLOSURES FOR SUSTAINABLE BUILDING PROGRAMS

Seminar 29. Urban Scale Building Energy Modeling, Part 5

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

Measured and Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction

Roadmap to Carbon Neutrality. October 30, 2008

SUPPORTING CARBON NEUTRALITY IN URBAN ENVIRONMENTS USING POSITIVE ENERGY BUILDINGS

The Future of Green Buildings in the Region. Faridah Shafii Institute Sultan Iskandar Universiti Teknologi Malaysia

Research Analysis: Building Envelope and LEED Credits Introduction

Home Built to LEED- H Silver Standards Monmouth County, NJ

Energy and Environmental Analysis of Propane Energy Pod Homes

LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction

Environmental Implications of Increasing Wood Use in Building Construction. Dr. Jim Bowyer Dovetail Partners Minneapolis, MN

Construction Report NYSERDA Residential Performance Challenge

Green Building. Metrics. May 7, Mark Frankel

Energy Study. Commercial Custom Design Program Retrofit Projects. November 2014

ROXUL Blanket (and Batt) Insulation Section Master Guide Specification (AFB) Page 1 April 2015

Learning Objectives (Part 1+2)

PROJECT DESIGN EVALUATION AND APPROVAL PROCESS DESIGN AND CONSTRUCTION STANDARD

Low-E Storm Windows: A Coming of Age

SUSTAINABILITY An Energy & Emissions Case Study

NREL Commercial Buildings Research

Michigan Energy Code Training and Implementation Program

Energy Saving Analysis of High Performance Commercial Buildings in India

BUILDING OTTAWA S ENERGY REVOLUTION. How the City of Ottawa Can Encourage Greener Building Practices

City Council Staff Report

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Sustainable Building Operations & Upgrades

Life Cycle Assessment performance comparison of small solar thermal cooling systems with conventional plants assisted with photovoltaics

R-Value. Effective. Energy efficiency of masonry s thermal mass is recognized by code 9" 2" R21 + R18 THERMAL MASS +13 R13 R18

Comparison of the Life Cycle Assessments of an Insulating Concrete Form House and a Wood Frame House

500 WEST PUTNAM AVENUE GREENWICH, CT

The City of Toronto s ZERO EMISSIONS BUILDING FRAMEWORK, TGS V3.0 Lisa King, City Planning Division CaGBC Chapter breakfast June 13, 2017

Residential New Construction. Baseline Study of Building Characteristics. Homes Built After 2001 Codes

Green Building. Certificate. Green building design, construction, materials, and economics to design a LEED Certified building.

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

BUILDING ENERGY NEEDS with particular attention paid to THERMAL INSULATION

Energy codes for Mediterranean Climates: comparing the energy efficiency of High and Low Mass residential buildings in California and Cyprus.

Transcription:

Proceedings of the 2013 Industrial and Systems Engineering Research Conference A. Krishnamurthy and W.K.V. Chan, eds. Life-Cycle Assessment of LEED vs. Conventionally Constructed Residential Units Abstract Woo-suk Chun, Peter P. Feng, Alfred E. Thal., Jr., and Adedeji B. Badiru Air Force Institute of Technology 2950 Hobson Way, Wright-Patterson Air Force Base, Ohio 45433-7765, USA The United States Air Force constructed 1,028 LEED for Homes Silver and/or ENERGY STAR certified energy efficient homes in Biloxi, Mississippi. To analyze and compare these energy efficient homes to conventionally constructed homes, this study employed a hybrid LCA and energy simulation. Compared to conventional homes, the energy efficient homes were found to have a 16% less environmental impact, consume 15% less energy, and save 2% in total life cycle cost while incurring a 1% cost increase in project construction. The simple payback period for the 1% construction cost increase was 10 years. The most effective energy efficient measure implemented was increasing the air conditioning seasonal energy efficiency rating (SEER) while the least effective measure was increasing the roof insulation R-value. Lastly, energy simulation results from the schematic design phase were statistically different compared to energy simulation results from the detailed design phase. By comparing the results of energy simulations from both design phases, simulation results from the detailed design phase were more accurate. The recommendation for a design team is to delay performing energy simulation until determining which energy efficiency measures to implement as permitted by the project timeline, cost, and other factors influencing the project. Keywords LEED; EIO-LCA; Hybrid LCA; Residential buildings; Energy simulation 1. Introduction 1.1. Background The United States government is the world s largest volume-buyer of energy related products [1]. Figure 1 shows that the Department of Defense (DoD) consumes 91% of all federal energy consumption; of the four services, the United States Air Force (USAF) consumes 64% while 12% is attributed to facility operations [1]. In an effort to reduce energy consumption for facility operations, the USAF requires all vertical military construction (MILCON) be certifiable in Leadership in Energy and Environmental Design (LEED) Silver [2]. The LEED rating system measures overall performance of a building in five areas: sustainable site development, water savings, energy efficiency, material selection, and indoor environmental quality [3]. According to the U.S. Government Services Administration (GSA), 12 LEED GSA buildings consumed 26% less energy and emitted 33% fewer greenhouse gases (GHGs) compared to the average performance of U.S. commercial buildings [4]. Newsham et al. (2009) reported that LEED buildings used 18-39% less energy per floor area than their conventional counterparts. However, 28 35% of LEED buildings used more energy than their conventional counterparts [5]. Given these contradictory results, the use of energy simulation and life-cycle assessment (LCA) in the early stages of design will help capture the reduction of environmental impact and energy consumption. 1177

U.S. Federal Government Fuel Consumption (percent of total petroleum consumption in billions of BTUs) 9% DoD Other Government 91% Figure 1. U.S. Government Energy Snapshot [1] 1.2. Energy Simulation Energy simulation is a method to provide whole building performance analysis [6]. By using an energy simulation method, a design team can predict the building performance and evaluate design options to reduce energy consumption. Energy simulation results also serve as a baseline to determine whether the building is operating as designed. This research utilized two energy simulation tools: ESim and equest [7, 8]. ESim employs computational algorithms which are based on fundamental thermodynamic, psychrometric and heattransfer calculations. However, data input requirements are the minimum necessary to model the major energy flows, control systems, and equipment [8]. Due to limited data input requirements, ESim cannot model nonconditioned zones in a building and ESim automatically assumes that a building is a box shape, so information available during the schematic design phase is sufficient. Raffio et al. (2006) used ESim to simulate energy consumption of an energy efficient house at the University of Dayton and found that the house consumed 52% to 58% less energy compared to a conventionally constructed house [9]. equest combines a wizard for building model creation and energy efficiency measure analysis with a detailed interface which links to the DOE-2.2 simulation engine [7]. The wizard of equest enables users to input detailed design information and define a floor layout. Zhu et al. (2009) employed equest to simulate energy consumption of a zero-energy house and a conventional house in Las Vegas, NV [10]. The data showed that a radiant barrier and a water-cooled air conditioner are major contributors to the energy savings while an insulated floor slab and thermal mass walls are not effective for energy conservation [10]. 1178

1.3. Life-Cycle Assessment (LCA) LCA analyzes the environmental impact of a product or process throughout its entire life-cycle [11]. A typical LCA involves three main objectives: (1) inventory analysis which estimates negative environmental impacts, (2) impact analysis which estimates the stress caused by these burdens on humans and nature, and (3) improvement analysis which identifies areas where improvements are possible [11]. To achieve these objectives, an LCA methodology usually consists of four steps[12]. 1. Goal, project scope, and boundary definitions 2. Inventory analysis to estimate environmental burdens 3. Impact assessment 4. Interpretation of the results subjected to sensitivity analysis and prepared for communication There are three common types of LCA available: process-based LCA, economic input-output LCA (EIO-LCA), and hybrid LCA. Process-based LCAs can produce detailed results where a specific product or process can be compared; however, they can be restricted and incomplete due to data availability, time, and associated cost [11]. A process-based LCA includes direct suppliers, but seldom includes the complete hierarchy of suppliers that is, all the suppliers of suppliers (indirect) [11]. The EIO-LCA model uses economic input-output matrices and industry sector level environmental and resource consumption data to assess the economy-wide environmental impacts of products and processes [13]. This facilitates the analysis and comparison of data at a systems level. The EIO-LCA can be repeated because it uses publicly available data; however, the results of the analysis represent the impacts from a change in demand for an industry sector. Additionally, the EIO-LCA models are incomplete in as much as a limited number of environmental effects are included. Lastly, the data used to produce the EIO-LCA can be outdated and incomplete [14, 15]. Due to the complex nature of construction, the process-based LCA and the EIO- LCA methods are somewhat complex and computationally intensive. Therefore, this research utilized a hybrid LCA model which incorporates the advantages of both the process-based and EIO methodologies. 1.4. Project History In 2006, the USAF awarded a $290 million contract to construct 1,028 residential homes at Keesler Air Force Base, MS. The objective was to replace 1,820 military family homes, which were damaged or destroyed during Hurricane Katrina, using conventional construction. During construction, the USAF increased the project scope by $2 million to pursue ENERGY STAR certifications for all 1,028 homes and Leadership in Energy and Environmental Design (LEED) for Homes Silver certifications for 736 residential units. Eleven types of single family dwelling units and 17 types of duplex units using a variety of 14 different floor plans exist, with the size of the units ranging from 1,705 ft 2 (158m 2 ) to 4,200 ft 2 (390 m 2 ). 1.5. Objectives We used information obtained from energy simulations with construction data (i.e., design, total project cost) for the homes to perform a hybrid LCA and address the following research objectives. i. Quantify the environmental impact and energy consumption differences between energy efficient and conventionally constructed homes. ii. Analyze individual energy efficiency measures to quantify the energy reduction contribution. iii. Compare energy simulation results from schematic design and detailed design. 2. Methods 2.1. LCA Using results from energy simulations and data extracted from USAF facility maintenance instructions and construction documents, a hybrid LCA was used to quantify and compare the environmental impact of energy efficient homes constructed at Keesler AFB to conventionally constructed homes. The hybrid LCA consisted of four steps[16]. 1. Derive an input-output LCA model 2. Extract the most important pathways for the construction sectors 3. Derive case-specific LCA data for the building and its components 4. Substitute the case specific LCA data into the input-output model 1179

The life-cycle of this project was divided into three phases similar to the EIO-LCA conducted for U.S. residential buildings by Ochoa et al. [17]: (1) construction, (2) use, and (3) disposal. The construction phase included raw material acquisition, material manufacturing, and construction of the homes. The use phase included remodeling, home improvement, heating, cooling, lighting, daily electrical consumption other than lighting, and hot and cold water consumption. Lastly, the disposal phase included demolition, recycling, and disposal of construction debris [17]. Table 1 summarizes the LCA types conducted for each phase. Phase Construction Use Disposal Table. 1. LCA Types LCA Types EIO-LCA Case specific LCA based on energy Operations simulation results Maintenance & Repair EIO-LCA EIO-LCA We calculated the total environmental impact and energy consumption using the original contract cost for the construction phase of conventional homes. For the construction phase of energy efficiency homes, we used the modified contract cost to determine the total environmental impact and energy consumption. The use phase was divided into two components: operations and maintenance/repair. To calculate the operations cost, we used equest to simulate energy consumption (both electricity and natural gas) assuming a life of 60 years. The electricity and natural gas costs of Biloxi, Mississippi, in 2002 were 7.28 cents per kwh and $7.76 per 1,000cfm, respectively [18, 19]. The annual maintenance and repair cost of these homes was determined to be 1% of the total construction cost in accordance with USAF facility maintenance instructions for both conventional and energy efficient homes. Lastly, the disposal cost was calculated to be 1% of total lifetime cost of the project based on past studies for both conventional and energy efficient homes [20]. The EIO-LCA tool used in this study is based on the U.S. economy annual input-output from 2002. All monetary values were brought back to 2002 by using 3% annual inflation rate following the EIO-LCA conducted for U.S. residential buildings by Ochoa et al. [17]. 2.2. Sensitivity Analysis Since any facility can be considered a system of systems, various components of a home interact closely with each other to influence the total energy consumption during operations. Using equest s energy efficiency measure analysis tool, we conducted a sensitivity analysis on the major energy efficiency measures implemented to make Keesler homes energy efficient and quantified the individual effect of the measures on the facility. Table 2 outlines the most prominent energy efficiency measures adopted and analyzed for this study. Table 2. Housing Characteristics Characteristics Conventional KEESLER AFB Housing Profile LEED for Homes/ENERGY STAR Structural Framing 2 x4 @ 16" (0.05m x 0.10m @ 0.41m) 2 x6 @ 16" (0.05m x 0.15m @ 0.41m) on center (O.C.) wood frame O.C. wood frame Wall Insulation R-value: 11 h ft 2 ºF/Btu (1.94 K m 2 /W) R-value: 19 h ft 2 ºF/Btu (3.35 K m 2 /W) Unfaced Batt Insulation Unfaced Batt Insulation Roof Insulation R-value: 21 h ft 2 ºF/Btu R-value: 30 h ft 2 ºF/Btu (3.70 K m 2 /W) (5.28 K m 2 /W) Roof Color Dark Light Infiltration (ACH*) 0.68 0.35 Cooling (SEER**) 10 Btu/W hr 16 Btu/W hr Heating (HSPF***) 6.8 Btu/W hr 9.2 Btu/W hr * ACH: Air changes per hour ** SEER: Seasonal energy efficiency rating *** HSPF: Heating seasonal performance factor 1180

2.3. Schematic Design vs. Detailed Design LEED recommends that project teams pursuing LEED certification adopt energy simulation early in the design phase. The question is how early? Does energy simulation conducted in the schematic design phase provide a similar energy profile to energy simulation in the detailed design phase of construction? Using equest, energy simulations at different phases of design were statistically analyzed. 3. Results and Discussions 3.1. LCA To quantitatively analyze and compare the environmental impacts of Keesler s energy efficient homes to conventionally constructed homes, we utilized a hybrid LCA approach using simulated energy data and costs obtained from construction documents and Air Force facility operation instructions. For energy simulation, the accuracy of a building s energy consumption behavior (energy consumption profile) depends on the accuracy of the building characteristic inputs. Additionally, the building occupant behaviors must be taken into consideration. Therefore, collecting historical energy consumption data is crucial to accurately simulate the energy consumption profile while taking into account occupant energy consumption behaviors. Regretfully, Keesler AFB did not collect energy consumption data. Therefore, one quick way to validate the energy simulation model was to compare the average end use intensity (EUI) of conventional homes. From the energy simulation, the average EUI of conventional homes is 7.2 kwh/ft 2 yr (280 MJ/m 2 yr) with a standard deviation of 0.25 kwh/ft 2 yr (10 MJ/m 2 yr). This is comparable to the 7.6 kwh/ft 2 yr (294 MJ/m 2 yr), value reported by RWL Analytics (2007) as the average EUI of newly constructed homes using electrical heating system in 2006 [21]. Figure 2 shows that the construction phase economic activity represents 65% of the total life-cycle cost for conventional homes with support infrastructure. The global warming potential (GWP) and energy consumption during the construction phase are 20% and 22%, respectively. The economic activity of the use phase (operations, maintenance, and repair) is relatively small at 34% compared to the construction phase, but the GWP and energy consumption of the use phase, 79% and 78%, respectively, represent a major portion of the total GWP and energy consumption. Lastly, the economic activity, GWP, and energy consumption in the disposal phase are negligible. Figure 2 also shows that energy efficient homes with support infrastructure follow a similar trend. The construction phase economic activity represents 67% of the total life-cycle economic activity. The GWP and energy consumption during the construction phase are 24% and 27%, respectively. For the use phase, the economic activity is 32%, while GWP is 75% and energy consumption is 73%. Lastly, the economic activity, GWP, and energy consumption are negligible in the disposal phase. Note that the use phase constitutes a large portion of GWP and energy consumption; therefore, any economically feasible steps taken to reduce energy consumption and GWP during the use phase can have great impacts. Ochoa et al. [17] conducted an EIO-LCA of the U.S. residential sector for 1997 and found that within the three phases, the use phase (54% of economic activity) is the largest consumer of energy (93%) and has the largest GWP (92%). A process-based LCA conducted by Scheuer et al. [22] reported similar results where the use phase energy consumption accounted for 94% of life-cycle primary energy consumption. The results from past studies are slightly different from this study s findings, with the primary difference being the project scope. Unlike the previous two studies, this study included support infrastructures like access roads and utility mains. Adjusting the construction costs, by excluding the support infrastructure costs, reduces the differences significantly. During the construction phase, Figure 2 shows that conventional homes represent 49% of the economic activity, while the GWP and energy consumption are 12% and 13%, respectively. For the use phase, the economic activity is 50%, while GWP is 88% and energy consumption is 87%. The disposal phase still plays a minor role. For energy efficient homes without support infrastructure, the construction phase economic activity represents 52% of the total life-cycle economic activity, while the GWP and energy consumption are 14% and 16%, respectively. For the use phase, the economic activity is 47%, while GWP and energy consumption are 85% and 84%, respectively. The economic activity, GWP, and energy consumption are negligible during the disposal phase. The results for energy efficient homes are similar to results reported by Blanchard and Reppe [23], who found that the construction phase represents 16% of the total life-cycle energy of an energy efficient home where the use phase represents 83%. 1181

EIO-LCA Results: Economic Activity 400 Cost ($M) 350 300 250 200 150 100 50 0 16% 17% 18% 15% 24% 25% 26% 22% 65% 67% 49% 52% Conventional LEED Conventional LEED Demolition Maintenance Operation Construction w/ Infrastructure w/o Infrastructure EIO-LCA Results: Global Warming Potential GWP (metric tons of CO2) 800 700 600 500 400 300 200 100 0 5% 6% 6% 7% 74% 69% 82% 78% 20% 24% 12% 14% Conventional LEED Conventional LEED Demolition Maintenance Operation Construction w/ Infrastructure w/o Infrastructure EIO-LCA Results: Energy Consumption Energy Consumption (TJ) 10000 8750 7500 6250 5000 3750 2500 1250 0 6% 7% 7% 8% 71% 66% 80% 76% 22% 27% 13% 16% Conventional LEED Conventional LEED Demolition Maintenance Operation Construction w/ Infrastructure w/o Infrastructure Figure 2. LCA Results (with and without support infrastructure) Overall, a 1% increase in construction cost resulted in a 2% reduction of the overall total life-cycle cost, a 16% GWP reduction, and a 15% reduction in total energy consumed. The GWP and energy consumption fall short of the 33% GHG reduction and 18-39% energy reduction reported in previous studies [4]. These differences may be due to different LEED certification approaches the USAF took compared to LEED certified buildings. Additionally, the simple payback period of for the initial $2 million dollar investment to build energy efficient homes was 10 years. 1182

3.2. Effectiveness of Energy Efficiency Measures Construction budgets are limited and design teams often face decisions regarding which energy efficient measures to implement. By analyzing the effect of readily adopted energy efficient measures, design teams can prioritize the measures available to minimize the energy consumption. Figure 3 shows the individual effects of several major energy efficiency measures implemented during the construction phase and the effect of adjusting cooling and heating temperature set-points. The measure with the greatest impact is cooling temperature set-points. Changing cooling set-points from 68 F (20 C) to 80 F (27 C) reduced the EUI by 10%. However, the occupants cooperation to adjust cooling set-points higher cannot be guaranteed. The measure implemented during the construction phase with the greatest impact is increasing cooling system efficiency. Changing an air conditioning unit with SEER 10 to an air conditioning unit with SEER 23 resulted in an 8% EUI reduction. The least effective measure implemented during the construction phase is increasing the thermal resistivity (R-value) of a roof. This measure, with an increase in R-value from 21 h ft 2 ºF/Btu (3.7 K m 2 /W) to 60 h ft 2 ºF/Btu (11 K m 2 /W) only reduced EUI by 2%. Affected by warm weather year-around, increased efficiency of a heating system and decreasing heating temperature set-points from 80 F (27 C) to 68 F (20 C) do not have as great of an impact on energy consumption reduction as cooling system changes. However, these measures still result in 6% and 3% reduction of EUI, respectively. Energy Efficiency Measure Effectiveness 10% 9% 8% 7% 6% 5% 4% 3% 2% 1% Cooling 0% SEER 10 SEER 16 SEER 19 SEER 23 Infiltration (ACH) ACH 0.9 ACH 0.65 ACH 0.5 ACH 0.35 Wall (R-value) Roof (R-value) Heating Set Pt (Cooling) Set Pt (Heating) R-11 R-21 HSPF 6.8 80 F R-19 R-30 HSPF 8 76 F 72 F R-23 R-45 HSPF 9 72 F 76 F R-41 R-60 HSPF 11 68 F 80 F Figure 3. Effectiveness of Energy Efficiency Measures Implemented 3.3. Energy Simulation Using Schematic Design vs. Detailed Design Two key assumptions were made to differentiate the design stages: (1) the floor layout was not clearly defined and (2) the building s exterior shape was not clearly defined during the schematic design phase. Following these assumptions, ESim can simulate energy consumption in the early design stage. However, equest requires more 1183

information available in the later design stage where the floor layout is clearly identified and the building s exterior shape has been defined. Using ESim, the average EUI is 6.3 kwh/ft 2 yr (250 MJ/m 2 yr) with a standard deviation of 0.29 kwh/ft 2 yr (11 MJ/m 2 yr). Using equest, the average EUI was 6.0 kwh/ft 2 yr (230 MJ/m 2 yr) with a standard deviation of 0.27 kwh/ft 2 yr (10 MJ/m 2 yr). Before comparing the EUIs, we used the Shapiro-Wilk test to assess the normality of the data. The Shapiro-Wilk test indicated that the EUIs calculated using schematic design and detailed design were bimodally distributed instead of normally distributed. Additionally, we used Levene s test to assess the homogeneity of variances assumption. The Levene s test indicated that the EUIs do not have equal variance. Since the EUIs calculated are not normally distributed and do not show homogeneity of variances, we employed the Wilcoxon signed rank test to compare the median EUIs instead of the mean EUIs. The resulting p-value from the Wilcoxon signed rank test was less than 0.0001, which indicates that the median EUI from the schematic design is statistically different from the median EUI calculated using detailed design. The main reason for the bimodal distribution in EUIs is the two types of prototypical facilities used for the design. The first type assume homes designed in generally square shapes, while the second type relied on rectangular shapes with long exterior side walls and shorter front and back exterior walls. This difference in shape resulted in the bimodal distribution of EUIs where square-shaped homes generally had lower EUIs. LEED recommends design teams simulate energy consumption in the early design phase, but the timing of conducting energy simulations must be adjusted based on the objectives of simulating energy consumption. The statistical difference suggests that the design team delay energy simulations until the design is at the final stage if the intent is to quantify energy savings and develop a building s energy performance baseline. However, the design teams should simulate energy consumption in the early design phase as LEED recommends if the intent is to modify designs based on energy simulation results. This is consistent with work by Feng et al. (2008) demonstrating how rework timing affects the entire project by delaying the final plan and work in order to resolve unknowns; therefore, the overall time required for negative rework decreases [24]. 3.4. Limitations and Future Research Topics Historical energy consumption data can help calibrate the energy simulation to create a more realistic energy consumption profile. A lack of historical energy data for the Keesler homes limited the strength of the energy simulation used in this study. We were able to compare the EUI with published data, but it is highly recommended that energy consumption data of Keesler homes be collected to further strengthen the energy simulation. Additionally, the weather data used in this study was limited to Biloxi, MS; therefore, the LCA and sensitivity analysis results only represent Biloxi, MS. Selecting different cities around the U.S. to study the effect of different weather patterns on the LCA and sensitivity analysis will be appropriate. Lastly, many different approaches exist for LEED certification. It is appropriate to analyze different LEED certification approaches and their effect on the total life-cycle cost, environmental impact, and total energy consumption. 4. Conclusions The decision to build LEED and/or ENERGY STAR homes at Keesler AFB resulted in a 16% environmental impact reduction, 15% energy consumption reduction, and 2% total life-cycle cost reduction. The environmental impact and energy consumption reductions fall short of results reported in previous studies; however, this study reinforces a claim that LEED certified homes save energy and reduce the environmental impact while reducing the total lifecycle cost. The most effective energy efficient measure implemented in Mississippi was increasing the air conditioning SEER value while the least effective measure was increasing the roof insulation R-value. Prioritizing the impact of energy efficiency measures provides guidance to the maintenance team at Keesler AFB to offer additional attention to more effective measures. Additionally, the prioritized list allows design teams to maximize energy efficiency efforts by adopting measures with the greatest impact. However, the most effective measure of all is to educate occupants to adjust cooling set-points to a higher temperature. Lastly, energy simulation results from the schematic design phase were statistically different when compared to energy simulation results from the detailed design phase. The recommendation to a design team is to delay performing energy simulation until the design is nearing the final stage. 1184

References 1. Assistant Secretary of the Air Force Installtions, Environment, and Logistics,2009, "Air Force Energy Plan 2010", Washinton, DC, 2009. 2. Eulberg, D., 2007, " Air Force Sustainable Design and Development Policy," Washington, DC. 3. USGBC,2009, "Intro - What LEED Is," 2009. 4. GSA, 2008, "Assessing Green Building Performance: A Post Occupancy Evaluation of 12 GSA Buildings," GSA Public Buildings Service, Office of Applied Science, Washinton, DC. 5. Newsham, G.R., Mancini, S., and Birt, B.J., 2009, "Do LEED-certified building save energy? Yes, but..." Energy and Buildings, 897-905. 6. Hirsch, J.J., 2010, equest Introductory Tutorial, version 3.64. 7. Hirsch, J.J., "equest; the Quick Energy Simulation Tool," DOE2.com. 8 Kissock, K., 1997, ESim, University of Dayton, Dayton, OH. 9. Raffio, G., Mertz, G., and Kissock, J.K., 2006, "Cost-benefit Analysis of Net Zero Energy Campus Residence," ASME International Solar Energy Conference, ASME, Denver, 1-9. 10. Zhu, L., Hurt, R., Correa, D., and Boehm, R., 2009, "Comprehensive energy and economic analyses on a zero energy house versus a convetional house," Energy, 34, 1043-1053. 11. Horvath, A., and Hendrickson, C., 1998, "Comparison of Environmental Implications of Asphalt and Steel- Reinforced Concrete Pavements," Transportation Research Record: Journal of the Transportation Research Board, 1626, 105-113. 12. Chester, M.V., 2008, "Life-cycle Environmental Inventory of Passenger Transportation in the United States," Ph. D disseratatin, University of California, Berkeley. 13. Hendrickson, C., Horvath, A., Satish, J., Klausner, M., Lave, L., and McMichael, F., 1997, "Comparing Two Life Cycle Assessment Approaches: A Process Model vs. Economic Input-Output Based Assessment," IEEE International Symposium on Electronics and the Environment, San Francisco, CA, 176-181. 14. Economic Input-Outpt Life Cycle Assessment, Carnegie Mellon University. 15. Hendrickson, C.T., Lave, L., and Matthews, H.S., 2006, "Environmental Life Cycle Assessment of Goods and Services: An Input-Output Approach," Resources for the Future Press. 16. Treloar, G.J., Love, P.E.D., Faniran, O.O., and Iyer-Raniga, U., 2000, "A Hybrid Life Cycle Assessment Method for Construction," Construction Management and Economics, 5-9. 17. Ochoa, L., Hendrickson, C., and Matthews, H.S., 2003, "Economic Input-Output Life-cycle Assessment of U.S. Residential Buildings," Journal of Infrastructure Systems, 8 (4), 132-138. 18. EIA, 2010, "Mississippi Electricity Profile," U.S. Department of Energy. 19. EIA, 2010, "Natural Gas Prices, in, U.S." Department of Energy. 20. Kannan, R., Leong, K.C., Osman, R., and Ho, H.K., 2007, "Life cycle energy, emissions and cost inventory of power generation technologies in Singapore," Renewable and Sustainable Energy Reviews, 11 (4), 702-715. 21. RLW Analytics, 2007, Residential New Construction (Single and Multi-Family) Billing Analysis,Portland, OR. 22. Scheuer, C., Keoleian, G.A., and. Reppe, P., 2003, "Life Cycle Energy and Environmental Performance of a New University Building: Modeling Challenges and Design Implications," Energy and Buildings, 35 1049-1064. 23. Blanchard, S., and Reppe, P., 1998, "Life Cycle Analysis of a Residential Home in Michigan," M. S. Thesis, School of Natural Resources and Environment, University of Michigan. 24. Feng, P., Tommelein, I.D., and Booth, L., 2008, "Modeling the Effect of Rework Timing: Case Study of a Mechanical Contractor," 6th Annual Conference of the International Group for Lean Construction, Manchester, UK.. 1185