Roof e Flat r xhaust trap oof ventilators 4 models for FLAT ROOF

Similar documents
AIR INTAKE VENTS. Special air intake Models for

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

SECTION TURBINE VENTILATORS

CS-100 Guide Specifications

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

SECTION ROOF ACCESSORIES

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers

DICTATOR Lift Shaft System

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

SECTION ROOF SPECIALTIES

B U I L T F O R L I F E

Series - 1

Residential Garage Doors Miami-Dade Hurricane Ready. Miami-Dade Hurricane Ready Residential Garage Doors

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

Littlies. Willplay s Littlies range offers floor. Cool activities for little kids!

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

MILLENNIUM METALS, INC TEST REPORT

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Decks/Liners. structural steel decks and liner trays.

ROOF DRAINS TABLE OF CONTENTS

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Effective Date: Jan. 1, 2016 DURAFLO SECTION ROOF VENTS WE KNOW VENTILATION

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION GUTTERS AND DOWNSPOUTS

Thermacore COLLECTION

External Coating Chart

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

PREFA Aluminiumprodukte GmbH Page 1 of 21

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

Can be installed. sloped roofs. on all. toutes les toitures. S adapte à 18 / 12 56º. 2/12 to 18/12. from

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

SHEET METAL ROOF TEST REPORT

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

Sapphire Metal Tile Roofing System

Three Great Steel Panels

Worldwide Competence in Plastics. Development by professionals. The long-lasting roof system

The under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION

MASTERFORMAT SPECIFICATION

STERLING. Construction & Development Corporation MODULAR BUILD. Cost Competitive System

PREFA Aluminiumprodukte GmbH Page 1 of 25

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SECTION SECTIONAL OVERHEAD DOORS

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

WESTECK WINDOWS and DOORS

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Sub-construction for Wall-mounted Longlight

CANAL COMPACT & CANAL PLUS. powerful warmth, perfectly integrated

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Installation Instructions

Siding and Soffit Installation Guidelines

ThermalShell Modular Insulated Pre-Cast Panels

Utility Cabinet System (UCS)

Corrosion Considerations PP C

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs


SECTION HVAC GRAVITY VENTILATORS

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

Corium Brick Rainscreen System Specifications

Trims for flat roofing. GRP Trims for flat roofing

ARCHITECTURAL SPECIFICATION: PLAYGROUNDS EPDM Rubber (Poured-in-Place)

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

Pioneer Forced Draft Cooling Tower Specifications

Installation Guide Wall Panels

Weatherproofing & Sealing Systems

TPO and PVC Roof Flashings and Accessories

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION G RELIEF VENTS A-0

CASSETTE BS Specification book

ALUMINUM SIDING SOFFITS, MOULDINGS AND ACCESSORIES

INTERIOR ENVIRONMENT

SL150 Guide Specification

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

SED-501. Sightproof Louver Drainable Blade. Application and Design

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

GENERAL SHALE NATURAL THIN ROCK VENEER Installation Guide. GeneralShale.com

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

The Uncloggable Roof Drain Dome LIT-058

Transcription:

models for FLAT ROOF Model VMAX-02-2 Deflector : Base : degree cant. Height : 23 / in. NFA : 9 in. 2 Ventilation Area : 00 to 0 ft. 2 Colours : Black, brown, grey and white CSA : Approved Model VMAX-02-2-MB Deflector : Base : insulated interior Height : / in. NFA : 9 in. 2 Ventilation Area : 00 to 0 ft. 2 Colours : Black, brown, grey and white CSA : Approved Model VMAX-0-2 Deflectors : Base : degree cant. Height : /2 in. NFA : in. 2 Ventilation Area : to 00 ft. 2 NB : For net air space between insulation & underside of roof deck of in. and more Colours : Black, brown, grey and white CSA : Approved Model VMAX-20-2-MB Deflectors : Base ; insulated interior NFA : 2 in. 2 Height : /2 in. Ventilation Area : to 0 ft. 2 NB : For net air space between insulation & underside of roof deck of in. and more Colours: Black, brown, grey and white CSA : Approved Features Steel : Structural galvanized steel ZF7 Gauge : & 2 Storm proof : Unique precision engineered deflector system Rodent proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection. Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion.

Flat roof ventilators MODEL VMAX-02-2 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one () ventilator model VMAX-02-2 has been calculated based on a 0 in. x 0 in. opening or (hole) of curb and roof deck. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. Model : VMAX-02-2 Deflector : Net Free Evacuation : 9 in. 2 Suggested Ventilation Area : 00 to 0 ft. 2 Tested Extraction Rate: 3 CFM Base Flashing : degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-27 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. A CODE# DIMENSIONS A B C D THE NET VENTILATION EVACUATION FOR MODEL 02-2 NUMBER OF DEFLECTOR STEEL GAUGE USED 02-2 9. 2.00 9 9 IN. 2 2 METRIC (mm) 9 30 27 83 0.02 M. 2 2 02-.0 2. 0 IN. 2 C 09 3 0.097 M. 2 02-2.0 2. 208 IN. 2 B 0 0 0.3 M. 2 02-8 28 8.0 2. 2 IN. 2 7 7 0.72 M. 2 D 02-20 32 20 9. 20 32 IN. 2 83 08 08 0.227 M. 2 02-22 3 22 9.0 20 08 IN. 2 8 9 08 0.23 M. 2 02-3 9.0 20 8 IN. 2 9 0 08 0.3 M. 2 The models #02- to #02- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

Roof exhaust trap Flat roof ventilators MODEL VMAX-0-2 Description VENTILATION CHART FOR MODEL VMAX-0-2 Net Ventilation air space between underside of roof deck & insulation in. to in. 7 in. to 2 in. 3 in. to in. Roof Area that one Ventilation 0 (2 x 2 ) can ventilate 0 is not recommended Use Model 02-200 ft. 2 20-300 ft. 2 Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one () ventilator model VMAX-0-2 has been calculated based on a 0 in. x 0 in. opening or (hole) of curb and roof deck. 2 in. and more 30-00 ft. 2 Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimensions that are available by special order. Model : VMAX-0-2 Deflectors : Net Free Evacuation : in 2. Tested Extraction Rate : 8 CFM Suggested Ventilation Area : to 00 ft 2. (Refer to chart) Base Flashing : degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-27 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED B 0-2 2 9.0 2.2 IN. 2 &2 METRIC (mm) 30 9 279 3 0.0929 M. 2 0-2.2 20.0 9 IN. 2 &2 3 9 279 2 0.2 M. 2 C 0-23.2 3.2 20.0 2 IN. 2 0 00 337 2 0. M. 2 0-8 8 2.2 3.2 20.0 3 IN. 2 7 337 2 0.209 M. 2 A D 0-20 0-22 20 27.2.7 20.0 08 702 00 2 22 29.2.7 20.0 00 IN. 2 0.28 M. 2 8 IN. 2 9 72 00 2 0.32 M. 2 0-3.2 8.2 20.0 7 IN. 2 7 0 803 2 0.372 M. 2 The models #0- to #0- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

Roof exhaust trap Flat roof ventilators MODEL VMAX-02-2-MB Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. All in one, no need of a wood curb, this model has been designed to allow you to install the roofing membrane onto the base flashing the same way you would a wood curb. We have made an allowance for the membrane so that the neck of the ventilator will go over both the flashing and the membrane. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow. Model : VMAX-02-2-MB Deflector : Net Free Evacuation : 9 in 2. Tested Extraction Rate : 3 CFM Suggested Ventilation Area : 00 to 0 ft 2. Base Flashing : Flat base, insulated interior flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey and white Compliances : CSA, CAN-3-A930M82, ASTM-27 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. A CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTOR STEEL GAUGE USED 02-2-MB 9.7 2 9 IN. 2 2 METRIC (mm) 02 30 27 38 0.02 M. 2 2 02--MB.0 7. IN. 2 C 0 3 0.093 M. 2 02--MB 2.0 7. 9 IN. 2 B 0 0 0.27 M. 2 02-8-MB 28 8.0 7. 2 IN. 2 7 7 0. M. 2 D 02-20-MB 32 20 9.0 3 IN. 2 83 08 0 0.209 M. 2 02-22-MB 3 22 9.0 00 IN. 2 8 9 0 0.28 M. 2 02--MB 3 9.0 8 IN. 2 9 0 0 0.32 M. 2 The models #02--MB to #02--MB are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

Roof exhaust trap Flat roof ventilators MODEL VMAX-20-2-MB Description VENTILATION CHART FOR MODEL VMAX-20-2-MB Net Ventilation Area between roof deck & insulation Roof Area that one Ventilation 20-2-MB (2 x 2 ) can ventilate Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. All in one, no need of a wood curb, this model has been designed to allow you to install the roofing membrane onto our base flashing the same way you would a wood curb. An allowance has been made for the membrane so that the neck of the ventilator will overlap both the flashing and the membrane. in. to in. 20-2-MB is not recommended Use Model 02-MB 7 in. to 2 in. to 20 ft. 2 3 in. to in. 2 in. and more 2 to 30 ft. 2 3 to 0 ft. 2 Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimensions that are available by special order. The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow. Model : VMAX-20-2-MB Deflectors : Net Free Evacuation : 2 in 2. Tested Extraction Rate : 3 CFM Suggested Ventilation Area : to 0 ft 2. (Refer to chart above) Base Flashing : Flat base with insulated interior Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-27 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87

DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. B CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED 20-2-MB 3 9.0 3.7 2 IN 2 &2 METRIC (mm) 330 9 279 39 0.078 M. 2 &2 20--MB 2.2.2 9 IN. 2 C 20--MB 38 9 279 3 7 23.2 3.2.2 0.09 M. 2 22 IN. 2 32 00 337 3 0. M. 2 20-8-MB 9 2.2 3.2.2 289 IN. 2 83 337 3 0.8 M. 2 A 20-20-MB 2 27.2.7.2 3 IN. 2 D 33 702 00 3 0.233 M. 2 20-22-MB 23 29.2.7.2 IN. 2 8 72 00 3 0.28 M. 2 20--MB 2 3.2 8.2.2 29 IN. 2 7 3 803 3 0.3 M. 2 7 The models #20--MB to #20--MB are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. 9229 Pierre Bonne, Montreal HE 7J Tel.: -8-80 Fax : -8-929 Watts: (Canada) -800--87