ichemistry SOLUTIONS Integrated chemistries to boost mass spectrometry workflows

Similar documents
MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

MultiQuant Software Version 3.0

Made for Routine Food, Environment, and Forensic Testing. The X500R QTOF System

Quantitative mass spec based proteomics

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Pharmacokinetic Analysis of the mab Adalimumab by ELISA and Hybrid LBA/LC/MS: A Comparison Study

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Spectrum Mill MS Proteomics Workbench. Comprehensive tools for MS proteomics

High Levels of Sensitivity and Robustness for Complex and Demanding Matrices SCIEX TRIPLE QUAD 5500 SYSTEM

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Application Note. Authors. Abstract

Understanding life WITH NEXT GENERATION PROTEOMICS SOLUTIONS

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Faster, easier, flexible proteomics solutions

Above and beyond the extraordinary

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

MBios 478: Mass Spectrometry Applications [Dr. Wyrick] Slide #1. Lecture 25: Mass Spectrometry Applications

New Approaches to Quantitative Proteomics Analysis

DISCOVERY AND VALIDATION OF TARGETS AND BIOMARKERS BY MASS SPECTROMETRY-BASED PROTEOMICS. September, 2011

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Thermo Scientific TSQ Quantum Access MAX

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Hongwei Xie, Martin Gilar, and John C. Gebler Waters Corporation, Milford, MA, U.S.A. INTRODUCTION EXPERIMENTAL

Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

PESTICIDE SCREENING APPLICATION SOLUTION

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

TurboMass GC/MS Software

Proteomics. Proteomics is the study of all proteins within organism. Challenges

[ VION IMS QTOF ] BEYOND RESOLUTION

Thermo Scientific Proteomics & Metabolomics Seminar Tour

Protein Valida-on (Sta-s-cal Inference) and Protein Quan-fica-on. Center for Mass Spectrometry and Proteomics Phone (612) (612)

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility

Center for Mass Spectrometry and Proteomics Phone (612) (612)

Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative performance. with unprecedented ease

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Conjugated protein biotherapeutics

Proteomics software at MSI. Pratik Jagtap Minnesota Supercomputing institute

Algorithm for Matching Additional Spectra

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Proteomics: A Challenge for Technology and Information Science. What is proteomics?

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

N- The rank of the specified protein relative to all other proteins in the list of detected proteins.

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

Drug Discovery Research Clinical Screening. Comparison of ELISA and AlphaScreen Assay Technologies for Measurement of Protein Expression Levels

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Thermo Scientific Orbitrap Fusion Lumos Tribrid Mass Spectrometer. Breakthrough Gains for Quantitative Biology. Sensitivity Transformed

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

Biomarker Discovery using Surface Plasmon Resonance Imaging

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS

Data Quality Worth Sharing

Pharmaceutical LC/MS Solutions from Agilent Technologies

The Five Key Elements of a Successful Metabolomics Study

DNA damage - AP site- Assay Kit (Cell-Based)

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Investigation of a Mammalian Cellular Model for Differential Protein Expression Analysis Using 1D PAGE and Cleavable ICAT Reagents

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Accelerate mab Characterization Using Automated Sample Prep

CaptiveSpray nanobooster

MSD Immuno-Dot-Blot Assays. A division of Meso Scale Diagnostics, LLC.

mab Glycopeptide Profiling with V-Tag Adding reliable glycoprofiling to your peptide mapping workflow with ease and simplicity

protein interaction analysis

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

Laboratory Reagents. for life science research.

Cyfra 21-1 IRMA. Product information Information about other products is available at: Userś Manual DE52100

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Overview of Solulink Products. June 2011

Quantitative Analysis of Two Cancer Signaling Pathways Using Multiplex-Immunoprecipitation and Targeted Mass Spectrometry

Immunoassays and Mass Spectrometry: Transitioning Technology

of Host changes to respond the early geography. df]

Liver Mitochondria Proteomics Employing High-Resolution MS Technology

ReproRNA -OKSGM is a non-integrating, self-replicating RNA-based reprogramming vector for generating induced pluripotent stem (ips)

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

special offers from your protein biology resource

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

Identification of Drug Metabolites via Mass Spectrometry

Proteomics and Protein Microarrays

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

Transcription:

ichemistry SOLUTIONS Integrated chemistries to boost mass spectrometry workflows ichemistry SOLUTIONS

ichemistry solutions ichemistry solutions are the world s only reagents and consumables that are customdesigned to boost the performance of your Extend and improve mass spectrometry quantitation All analytical workflows have their limits. ichemistry solutions are designed to boost the performance of workflows beyond conventional limits and enable new applications through advanced chemistries. mass spectrometer and improve sensitivity, productivity, and data precision. But success needs more than just a reagent. Combined with the AB SCIEX mass spectrometry systems and the resources of the ichemistry solutions designed to improve specific applications: Biomarkers and Omics global AB SCIEX service and support network, ichemistry solutions enable you to push the Clinical and Forensic limits of mass spectrometry by improving the quality and performance of your workflows. MS Qualification Food and Environmental

ichemistry for MS qualification solutions ichemistry solutions for biomarker and omics applications Optimize before you analyze Save time, save money, stay compliant and be confident that your mass spectrometer is performing at its best. ichemistry MS Performance Calibrants and Standards ensure your AB SCIEX mass spectrometer is tuned for optimal performance and delivers reproducible results. Avoid risking the integrity of your workflow Save time and resources Troubleshoot your mass spec in minutes Make sure you have the standards you need to qualify your instrument for IQ/OQ/PQ any day, any time ichemistry solutions for Biomarkers and Omics applications enable you to: Reduce sample complexity Analyze multiple samples simultaneously Provide a global internal standard for peptide quantitation Directly detect and quantify proteins and their isoforms Reduce sample complexity Cleavable ICAT reagents: selective fractionation of cysteinecontaining proteins reduces sample complexity Cleavable ICAT reagents are cysteine-specific, affinity-enabled mass tags that provide a powerful mass spectrometry-based method for separating and quantitatively analyzing protein expression differences from complex samples. With cleavable ICAT reagents, you can readily identify and quantify important classes of proteins such as membrane and low-abundance proteins that are often difficult to analyze by traditional methods. Cleavable ICAT reagents and workflows are easily integrated with AB SCIEX instrumentation and application-specific software for rapid, unattended quantitation and identification of biologically significant proteins. Achieve cysteine-specific protein labeling with precise MS quantitation Identify membrane and low-abundance proteins Integrate workflows into analytical platforms and software 1 Sample 1 (light) combine and proteolyze Quantify (MS) light heavy labeled cysteines multi-dimensional separation mass analysis 1 55 56 57 58 m/z NH 2 -EACDPLR-COOH Sample 2 (heavy) Identify (MS/MS) 2 4 6 8 m/z Relative quantitation workflow: Two samples are reduced and labeled in parallel, each with two chemically identical reagents, but differentiated in mass by 9 Da, then combined and digested. The labeled cysteine peptides are isolated via biotin-avidin interaction. The cleaved peptides are analyzed in MS mode to obtain quantitative information and then subjected to MS/MS for identification.

Analyze multiple samples simultaneously A global internal standard for peptide quantitation itraq reagents: the industry standard cited in over 84 peer-reviewed papers The ability to simultaneously analyze multiple samples readily enables important research into dosing, temporal investigations, biomarker elucidation, and absolute quantitation of target proteins. itraq reagents are a multiplexed set of four or eight isobaric By combining itraq reagents with AB SCIEX instrumentation and application-specific software such as ProteinPilot software you ll achieve the meaningful, highly accurate results for confident quantitative protein expression analysis. Peptide quantitation mtraq reagents To get quantitation results you can trust it is always better to use an internal standard. But synthesizing internal standards can take up to 6 weeks, and not all of them will be appropriate for MRM analysis. The mass differential mtraq Reagents are specifically designed for peptide quantitation using MRM and are significantly more economical when larger numbers of peptides need to be monitored. (same mass), amine-specific tags that yield labeled peptides that are easily quantitated using mass spectrometry. Achieve identification and quantitation of multiple samples simultaneously Available as duplex and triplex to radically increase sample throughput The simple peptide-based itraq workflow eliminates many of the restrictions and difficulties presented by other strategies, allowing protein coverage that includes post-translational modifications, affinity pull-downs, and membrane proteins. Maximize protein/proteome coverage Increase statistical confidence and relevance quantitate up to eight samples at a time High selectivity, MRM-based relative quantitation of every protein, peptide, and PTM with a single workflow Up to 1x more cost effective than synthetic internal standards S1 S5 S2 S6 S3 S7 S4 S8 Parallel Denature & Digest 113 114 115 116 117 118 119 121 192 191 19 189 188 187 186 184 Mix MS MS/MS 8 samples identical m/z 1197.61 Global Internal Standard 1 2 3 4 98 99... Parallel Denature & Digest 4 4 4 12 34 9899... itraq Reagents Quantitation 1 9 8 Identification Mix 1:1:1 113 114 115 116 117 118 119 121 116 118 115 121 113 114 % Intensity 7 6 5 4 3 2 1 Pool aliquot for Global Internal Standard (GIS) 8 MRM mtraq reagent 8 mtraq reagent mtraq reagent 8 mtraq reagent 4 117 119 9. 26.4 511.8 763.2 114.8 1266. Mass (m/z) Addresses mass space limitation allows for multiplexing Multiplexed workflow: Up to 8 samples are reduced and alkylated, digested, and labeled in parallel, each with reagents that are chemically identical and isobaric. The peptide pool from all the samples is combined and subjected to LC/MS/MS analysis. Each precursor peak in MS mode represents up to 8 samples. Both quantitation and identification is obtained in MS/MS mode. = protein reactive group. All biological samples are prepared in parallel and digested. An aliquot of each sample is collected and reacted with mtraq reagent 8 to form the Global Internal Standard (GIS). This 8 GIS solution is then mixed with the and 4 labelled samples at a 1:1:1 ratio, and the MRM transitions are monitored for all 3 versions of the peptides.

Direct detection of proteins and their isoforms ichemistry Solutions for food and environmental applications Cytochrome P45 protein assay Immunoassays can be expensive and often lack specificity for proper protein and protein isoform detection. LC/MS/MS is an ideal alternative, allowing direct detection of CYP45 protein The ichemistry CYP45 Protein Assay enables direct measurement of protein expression changes of 4 individual CYP45 isoforms (1A2, 2B6, 3A4, and 3A5) or 7 individual isoforms (1A2, 2B6, Accelerate contaminant analysis Simplified preparation of contaminant standards with idquant standards kits So you can verify and validate the performance of your method faster, improve efficiency, and speed up sample turnaround time. isoforms with high specificity and sensitivity. 2C9, 2C19, 2E1, 3A4, and 3A5) with high specificity, sensitivity, and accuracy for induction studies: New idquant standards kits for contaminant analysis streamline the preparation of contaminant standard solutions, providing Kits contain up to 2 chemical contaminant residues that are commonly found or are of high concern to regulatory agencies Directly measure CYP45 induction at the protein level Eliminate the need for expensive antibodies Get results that are equivalent to traditional mrna or activity assays the ultimate solutions for residue analysis and delivering faster results. The idquant standards kits contain certified reference materials (ISO Guide 34, ISO/IEC 1725 and ISO 91:28) and eliminate the need to source individual chemical contaminants or reagents and to measure each one manually. Solutions are provided as multiple mixes of 1-2 compounds per mix Concentrations are certified for internal calibration or as an external calibration reference material Stability conditions are provided to maintain confidence in reagent integrity Relative Fold CHange Protein Expression 35 3 25 2 15 1 5 1. 1. 1. 1. 28.9 9. 8.3.6.5.5 1.2 1.4 1A2 2B6 3A4 3A5 16.4 5.3 1.2.9 Short and Simple Workflow Amenable to 1s of Samples per Day Starting sample of microsomes or S9 cells Reduce and alkylate sample for 1 hour at 6ºC Digest sample with Trypsin for 4 hours at 37ºC Add isotope-labeled peptides to the digested solution Perform LC-MS/MS analysis Routine workflow WITHOUT idquant Standards Kit 9 steps to analysis 1. Source neat materials of individual compounds 2. Order neat materials of individual compounds 3. File and document Certificates of Analysis 4. Prepare stock solutions of each compound Routine workflow WITH idquant Standards Kit 4 steps to analysis 1. Order IDQuant Standards Kit 2. File and document Certificate of Analysis 3. Prepare working mixes and calibration standards 4. File and document calibration standard preparation records (-) Control 3-MC Treatment PB RIF Protein-level measurement Specificity Sensitivity Quantitation of many isoforms 5. File and document stock solution preparation records 6. Prepare intermediate mixes of compounds Total time to analysis: < 2 Days Control (.1%DMSO) Rif 1 µm PB 1 µm 3MC 2 µm Control (.1%DMSO) Rif 1 µm PB 1 µm 3MC 2µM Control (.1%DMSO) 3MC 2µM PB 1 µm Rif 1 µm mrna techniques Activity studies Western blots 7. File and document intermediate mix solution preparation records 8. Prepare working mixes and calibration standards 7x time savings! CYP 2B6 CYP 3A4 CYP 1A2 CYP45 MRM assays 9. File and document calibration standard preparation records Enzyme activity and expression: A strong correlation between enzyme activity, mrna expression, and protein expression measured by LC-MRM were observed following treatment of human hepatocytes with prototypical CYP inducers. Both the baseline and inducible levels of the CYP isoforms were easily detected by the LC-MRM protein quantitation method. The method requires no antibodies and avoids the drawbacks of Western Blotting, which is semi-quantitative at best. Total time to analysis: > 2 weeks * Total time to analysis includes estimate of time required for delivery of individual materials from suppliers.

ichemistry solutions for clinical research applications Easy compound derivatization for up to 1x boost in intensity ichemistry solutions for amino acid analysis Faster performance. Better accuracy. Pushing the limits in sensitivity Mass spec is a great tool for compound detection and quantitation, but sensitivity can sometimes be negatively impacted by matrix suppression, high background noise levels, poor ionization efficiency, or poor compound fragmentation. Amplifex Reagents are the only derivatizing agents intelligently designed, synthesized, and tested to boost ionization efficiency and improve fragmentation and chromatographic properties. Amplifex Reagents take the complexity out of compound derivatization with a simple (one-step), fast (3 minute, reproducible, and robust) derivatization procedure. Just mix the sample, incubate, and you re ready for analysis. Amplifex reagents are mass tags designed to react universally with a specific functional group. For example: Amplifex -Diene Reagent can be used to derivatize any molecule with a cis-diene system, including compounds such as Vitamin D3 and Vitamin D2 analogs, among others. The result is a signal enhancement of up to 1-fold. Amplifex -Keto Reagent is universal and reacts with keto or aldehyde compounds, including ketosteroids such as Testosterone, among others. Signal enhancements improve mass limits of detection by up to 5-fold. Derivatization is no longer a painful day-long process. The most diverse of the ichemistry solutions, atraq reagent is the ideal solution to quantitate amino acids in samples ranging from protein hydrolysates for omics applications, food and consumer products, and physiological fluids for clinical research and forensic toxicology samples. atraq reagents save time and money with faster, more complete analysis. With atraq, you can quantitate up to 45 amino acids and amines from a wide variety of samples, including physiological fluids, protein hydrolysates, food and beverages, and culture media more than 3 times faster than conventional amino acid analyzers. Get confident identification, superior accuracy, and precision with internal standards for every amino acid Achieve higher throughput with an analysis time of 18 minutes per sample Add custom amines, amino acids and small peptides, and create corresponding internal standards Amplifex Diene Signal Enhancement Amplifex Keto Signal Enhancement 1,25-Dihydroxyvitamin D3 2.3e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 x165 4 pg DHVD3 1.6e4 1.e4 9. 8. 7. 6. 5. 4. 4-Cholesten-3-one 1 pg 4-Cholesten-3-one x58 Amino acid sample atraq 121 28 NHS 113 28 NH PSer 113 28 NH ASn MRM AA MW 113 AA MW 121 atraq - sample atraq - standard 6.e4 4.e4 2.e4 4 pg DHVD3...5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 3. 2. 1.. 3 pg 4-Cholesten-3-one 3.5 4. 4.5 5. 5.5 6. 6.5 Internal standards 113 28 NH Ala 113 28 NH Pro... 113 28 NH Leu PSer ASn Pro Ala... Leu 3.2e6 3.e6 2.5e6 2.e6 1.5e6 1.e6 5.e5 Ergosterol x136 2.6 ng Ergosterol 1131 1 8 6 4 2. 3.2 3.4 3.6 3.8 4. 4.2 4.4 4.6 Cannot see compound without Amplifex 2.6 ng Ergosteral 1.5 2. 2.5 3. 3.5 4. 2 18 16 14 12 1 8 6 4 2 Testosterone 1 pg Testosterone x45 1 pg Testosterone 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 6 min Amino acid analysis using atraq reagents and an LC/MS/MS workflow: Samples for amino acid analysis are combined with atraq reagent, an internal standard consisting of a panel of isotopically-labelled amino acids of known concentration. The sample mixture is analyzed by LC/MS/MS in MRM mode, and the concentration of amino acids in the unknown sample can be directly determined by the peak ratio of the unknown sample relative to the internal standard (with correction for the amino acid concentration in the internal standard). 18 min

You invest in our technology. We invest in your success. As the world leader in mass spectrometry, AB SCIEX creates solutions that are backed by the industry s most extensive service and support organization. As part of AB SCIEX, SCIEX ichemistry solutions receive that same level of support. With a network of service professionals, experienced compliance specialists, and over 15 PhD application scientists worldwide, we are dedicated to supporting your technical needs and helping you get the most out of your mass spectrometry systems. Our customer support network is available to provide expert assistance in the use and application of SCIEX ichemistry solutions through a comprehensive range of services, including application support, technical service, and training. Whether you access our service and support team by phone, email or on-site visits, you can be confident that our organization will be there for you. For more information, visit www.sciex.com For Research Use Only. Not for use in diagnostic procedures. 212 AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. ICAT is a registered trademark of the University of Washington and is exclusively licensed to AB Sciex Pte. Ltd. 458212-1 5/212 Headquarters 5 Old Connecticut Path Framingham, MA 171 USA Phone 58-383-77 www.absciex.com International Sales For our office locations please call the division headquarters or refer to our website at www.absciex.com/offices