ISO INTERNATIONAL STANDARD. Determination of the viscosity of polymers in dilute solution using capillary viscometers

Similar documents
ISO INTERNATIONAL STANDARD

ISO 4575 INTERNATIONAL STANDARD. Plastics Poly(vinyl chloride) pastes Determination of apparent viscosity using the Severs rheometer

EAST AFRICAN STANDARD

ISO 642 INTERNATIONAL STANDARD. Steel Hardenability test by end quenching (Jominy test) Acier Essai de trempabilité par trempe en bout (essai Jominy)

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Hydraulic fluid power On-line automatic particle-counting systems for liquids Methods of calibration and validation

ISO INTERNATIONAL STANDARD

ISO 1409 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 648 INTERNATIONAL STANDARD. Laboratory glassware Single-volume pipettes. Verrerie de laboratoire Pipettes à un volume. Second edition

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality management systems Guidelines for configuration management

ISO INTERNATIONAL STANDARD

Provläsningsexemplar / Preview. First edition

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 604 INTERNATIONAL STANDARD. Plastics Determination of compressive properties. Plastiques Détermination des propriétés en compression

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

ISO INTERNATIONAL STANDARD

ISO 180 INTERNATIONAL STANDARD. Plastics Determination of Izod impact strength. Plastiques Détermination de la résistance au choc Izod

Information technology Security techniques Information security management systems Requirements

INTERNATIONAL STANDARD

This document is a preview generated by EVS

ISO 638 INTERNATIONAL STANDARD. Paper, board and pulps Determination of dry matter content Oven-drying method

ISO INTERNATIONAL STANDARD. Petroleum, petrochemical and natural gas industries Hairpin-type heat exchangers

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO 9161 INTERNATIONAL STANDARD. Uranium dioxide powder Determination of apparent density and tap density

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

Information technology Security techniques Information security management systems Requirements

ISO 6496 INTERNATIONAL STANDARD. Animal feeding stuffs Determination of moisture and other volatile matter content

ISO INTERNATIONAL STANDARD. Rubber compounding ingredients Process oils Determination of glass transition temperature by DSC

ISO 9897 INTERNATIONAL STANDARD. Freight containers Container equipment data exchange (CEDEX) General communication codes

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 3: Test methods

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Extenders for paints Specifications and methods of test Part 5: Natural crystalline calcium carbonate

ISO INTERNATIONAL STANDARD. Water quality Detection and enumeration of Pseudomonas aeruginosa Method by membrane filtration

This document is a preview generated by EVS

ISO 1171 INTERNATIONAL STANDARD. Solid mineral fuels Determination of ash. Combustibles minéraux solides Détermination des cendres

ISO 2085 INTERNATIONAL STANDARD. Anodizing of aluminium and its alloys Check for continuity of thin anodic oxidation coatings Copper sulfate test

ISO INTERNATIONAL STANDARD. Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature

ISO INTERNATIONAL STANDARD. Implants for surgery Ceramic materials Part 1: Ceramic materials based on high purity alumina

ISO INTERNATIONAL STANDARD. Plastics Determination of Charpy impact properties Part 1: Non-instrumented impact test

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

This document is a preview generated by EVS

ISO 8339 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties (Extension to break)

ISO 4898 INTERNATIONAL STANDARD. Rigid cellular plastics Thermal insulation products for buildings Specifications

ISO INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry

ISO INTERNATIONAL STANDARD. Cutting tools Designation of high-speed steel groups. Outils coupants Désignation des groupes d'aciers rapides

ISO 6734 IDF 15 INTERNATIONAL STANDARD. Sweetened condensed milk Determination of total solids content (Reference method)

ISO INTERNATIONAL STANDARD. Calculation of load capacity of spur and helical gears Part 6: Calculation of service life under variable load

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 5: Chemical loads

ISO INTERNATIONAL STANDARD. Hot-rolled stainless steel plates Tolerances on dimensions and shape

INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method

This document is a preview generated by EVS

ISO 6878 INTERNATIONAL STANDARD. Water quality Determination of phosphorus Ammonium molybdate spectrometric method

ISO INTERNATIONAL STANDARD. Plain end steel tubes, welded and seamless - General tables of dimensions and masses per unit length

ISO 3779 INTERNATIONAL STANDARD. Road vehicles Vehicle identification number (VIN) Content and structure

ISO 8872 INTERNATIONAL STANDARD. Aluminium caps for transfusion, infusion and injection bottles General requirements and test methods

ISO INTERNATIONAL STANDARD

IS INTERNATIONAL STANDARD

ISO Information and documentation Management systems for records Fundamentals and vocabulary

ISO INTERNATIONAL STANDARD

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD. Building construction Jointing products Specifications for test substrates

ISO INTERNATIONAL STANDARD. Mechanical vibration and shock Evaluation of human exposure to wholebody

ISO INTERNATIONAL STANDARD. Water quality Determination of the chemical oxygen demand index (ST-COD) Small-scale sealed-tube method

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Cutting tools Designation of high-speed steel groups. Outils coupants Désignation des groupes d'aciers rapides

ISO INTERNATIONAL STANDARD. Buildings and constructed assets Service-life planning Part 8: Reference service life and service-life estimation

ISO INTERNATIONAL STANDARD

ISO 185 INTERNATIONAL STANDARD. Grey cast irons Classification. Fontes à graphite lamellaire Classification. Second edition

ISO INTERNATIONAL STANDARD. Energy management systems Requirements with guidance for use


ISO INTERNATIONAL STANDARD. Quality requirements for fusion welding of metallic materials Part 4: Elementary quality requirements

ISO INTERNATIONAL STANDARD. Fasteners Preloading test for the detection of hydrogen embrittlement Parallel bearing surface method

ISO INTERNATIONAL STANDARD. Equipment for crop protection Induction hoppers Part 2: General requirements and performance limits

ISO INTERNATIONAL STANDARD. Glass in building Explosion-resistant security glazing Test and classification by shock-tube loading

ISO 8022 INTERNATIONAL STANDARD. Surface active agents - Determination of wetting power by immersion. Second edition

ISO 7401 INTERNATIONAL STANDARD. Road vehicles Lateral transient response test methods Open-loop test methods

ISO INTERNATIONAL STANDARD. Space systems Launch-vehicle-tospacecraft

ISO INTERNATIONAL STANDARD. Earth-moving machinery Operator enclosure environment Part 2: Air filter element test method

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Metallic materials Tensile testing Part 2: Method of test at elevated temperature

ISO INTERNATIONAL STANDARD. Specification for security management systems for the supply chain

ISO INTERNATIONAL STANDARD. Water quality Determination of sulfates Method by continuous flow analysis (CFA)

ISO INTERNATIONAL STANDARD. Plastics laboratory ware Single-use Petri dishes for microbiological procedures

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

IS I INTERNATIONAL STANDARD. Mobile equipment for continuous handling of bulk materials - Part 1: Rules for the design of steel structures

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Pallets for materials handling Quality of assembly of new wooden pallets

Transcription:

INTERNATIONAL STANDARD ISO 1628-2 Second edition 1998-12-01 Determination of the viscosity of polymers in dilute solution using capillary viscometers Part 2: Poly(vinyl chloride) resins Plastiques Détermination de la viscosité des polymères en solution diluée à l aide de viscosimètres à capillaires Partie 2: Résines de poly(chlorure de vinyle) A Reference number ISO 1628-2:1998(E)

ISO 1628-2:1998(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and nongovernmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. International Standard ISO 1628-2 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee 9, Thermoplastic materials. This second edition cancels and replaces the first edition (ISO 1628-2:1988) which has been modified to include: the determination of the K-value; a limit on the volatile-matter content of resins that can be tested using this part of ISO 1628; revised viscometer specifications; a reference viscometer; a precision statement. ISO 1628 consists of the following parts, under the general title Plastics Determination of the viscosity of polymers in dilute solution using capillary viscometers: Part 1: General principles This document is a preview generated by EVS ISO 1998 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Organization for Standardization Case postale 56 CH-1211 Genève 20 Switzerland Internet iso@iso.ch Printed in Switzerland ii

ISO ISO 1628-2:1998(E) Part 2: Poly(vinyl chloride) resins Part 3: Polyethylenes and polypropylenes Part 4: Polycarbonate (PC) moulding and extrusion materials Part 5: Thermoplastic polyester (TP) homopolymers and copolymers Part 6: Methyl methacrylate polymers This document is a preview generated by EVS ii

This document is a preview generated by EVS

INTERNATIONAL STANDARD ISO ISO 1628-2:1998(E) Determination of the viscosity of polymers in dilute solution using capillary viscometers Part 2: 1

ISO 1628-2:1998(E) ISO ISO 1269:1980, Plastics Homopolymer and copolymer resins of vinyl chloride Determination of volatile matter (including water). ISO 1628-1:1998, Plastics Determination of the viscosity of polymers in dilute solution using capillary viscometers Part 1: General principles. ISO 3105:1994, Glass capillary kinematic viscometers Specifications and operating instructions. 3 Definitions is Th The terms used in this part of ISO 1628 are defined in ISO 1628-1:1998, clause 3, and, in particular, definitions 3.3. (reduced viscosity) and 3.3.6 (K-value). cu do 4 Principle me A test portion is dissolved in a solvent. The reduced viscosity and the K-value are calculated from the efflux times for the solvent and the solution in a capillary tube viscometer. is nt 5 Materials re ap 5.1 Cyclohexanone, having a viscosity/density ratio (kinematic viscosity) between 2,06 10 6 m2 s 1 and 2,33 10 6 m2 s 1 (2,06 mm2 s 1 and 2,33 mm2 s 1) at 25 C. The specified boiling point shall be 155 C. Store the solvent in the dark in a dark-coloured bottle fitted with a ground-glass stopper. Check the kinematic viscosity before use. vie 6 Apparatus w ne ge The apparatus required to carry out viscosity measurements on polymers in dilute solution is described in ISO 1628-1:1998, clause 5. In addition, the following particular items are required for the procedures described in this part of ISO 1628: b ted ra 6.1 Viscometer: From the viscometers described in subclause 5.1 of ISO 1628-1:1998, model 1C, with a capillary diameter of 0,77 mm ± 2 %, from table B.4 of ISO 3105:1994, shall be used as the reference viscometer. Other viscometers described in ISO 1628-1 may be used provided the correlation between the chosen viscometer and the reference viscometer has been established over the range of reduced viscosities and K-values to be measured, and the results are corrected accordingly. VS ye 6.2 Graduated flask (one-mark volumetric flask), class A, as specified in ISO 1042, with a volume of 50 ml. NOTE use of a flask calibrated at a temperature of 20 C as specified in ISO 1042 causes a systematic error which can, however, be neglected. 6.3 Filter funnel, with fritted-glass filter disc of medium porosity (pore size 40 µm to 50 µm), or glass funnel with paper filter. 6.4 Mechanical agitator, equipped with a heating device to keep the flask (6.2) and its contents at a temperature between 80 C and 85 C. As an alternative, a rotary agitator or shaker may be placed in an oven at a temperature between 80 C and 85 C. 6.5 Analytical balance, accurate to 0,1 mg. 2